Have a look at the manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation For Adjuncts And Peripherals Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 Data Modules and Asynchronous Data Units 39 Connect Data Modules 4 Setting interface options on 7400A DCE 1. To ac c ess the menus, p ress the NEXT/NO b utton. 2. When the SET OPTIONS? p romp t ap p ears on the LCD. Press the NEXT/ NO b utton. 3. The VIEW OPTIONS? prompt appears. Press the NEXT/NO b utton. You will return to the op tions menus in a minute. But first you must selec t a c ommand interfac e for the d ata mod ule. 4. The SET INTERFACE? prompt appears. Press the ENTER/YES button. A series of INT = InterfaceType? prompts appears. 00—0 0 0 —— DATANEXT/NO BACK ENTER/YES l mmÜ l Push the b utton ind ic ated b y the arrow (Ü ) SET OPTIONS? DATANEXT/NO BACK ENTER/YES lÜ l m m Push the b utton ind ic ated b y the arrow (Ü ) VIEW OPTIONS? DATANEXT/NO BACK ENTER/YES lÜ l m m Push the b utton ind ic ated b y the arrow (Ü ) SET INTERFACE? DATANEXT/NO BACK ENTER/YES l mmÜ l Push the b utton ind ic ated b y the arrow (Ü )
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 Data Modules and Asynchronous Data Units 40 Connect Data Modules 4 5. For each prompt, if you want to select the interface, press the ENTER/YES b utton or, if you want a d ifferent interfac e, p ress the NEXT/NO b utton. a. Enab le the answer-only interfac e if the d ata mod ule must op erate without any kind of external c ontrol: b . Enab le the AT-c ommand interfac e if users need to c ontrol the d ata mod ule remotely, using a d ial-up c onnec tion and Hayes- compatible modem commands: c . Enab le the keyboard -d ial interfac e if users need to c ontrol the d ata mod ule interac tively, from a terminal: After you selec t an interfac e, the d ata mod ule runs a self-test and returns to the HOME sc reen. INT=ANS ONLY? DATANEXT/NO BACK ENTER/YES l mm m Se le c t a n o p t i o n ( N EXT/ N O o r EN TER/ YES) INT = AT COM? DATANEXT/NO BACK ENTER/YES l mm m Se le c t a n o p t i o n ( N EXT/ N O o r EN TER/ YES) INT = KYBD DIAL? DATANEXT/NO BACK ENTER/YES l mm m Se le c t a n o p t i o n ( N EXT/ N O o r EN TER/ YES) D T RD S RR ID C DR T SC T ST DR D HOME POWER TEST00—0 0 0 —— DATANEXT/NO BACK ENTER/YES Y7400A Data ModuleY mm m
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 Data Modules and Asynchronous Data Units 41 Connect Data Modules 4 Setting speed options on 7400A DCE 1. Press the NEXT/NO b utton to c ontinue with the setup p roc ed ure. 2. The SET OPTIONS? p rompt ap p ears on the LCD. Press the ENTER/YES b utton. A series of SET number SPEED? prompts appears. 3. Press the NEXT/NO b utton until you see the SET 9600 SPEED? p romp t. Then press the ENTER/YES b utton. Most DEFINITY c onnec tions op erate at the 9600 sp eed . 4. The 9600 = ON? prompt appears. Press the ENTER/YES button. 5. The CONTINUE? prompt appears. Press the ENTER/YES b utton. 00—0 0 0 —— DATANEXT/NO BACK ENTER/YES lÜ l m m Push the b utton ind ic ated b y the arrow (Ü ) SET OPTIONS? DATANEXT/NO BACK ENTER/YES l mmÜ l Push the b utton ind ic ated b y the arrow (Ü ) SET 9600 SPEED? DATANEXT/NO BACK ENTER/YES l mmÜ l Push the b utton ind ic ated b y the arrow (Ü ) 9600=ON? DATANEXT/NO BACK ENTER/YES l mmÜ l Push the b utton ind ic ated b y the arrow (Ü ) CONTINUE? DATANEXT/NO BACK ENTER/YES l mmÜ l Push the b utton ind ic ated b y the arrow (Ü )
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 Data Modules and Asynchronous Data Units 42 Connect Data Modules 4 6. The SET 19200 SPEED? p romp t ap p ears. Press the NEXT/NO b utton. 7. If you selec ted the AT-c ommand interfac e in the sec tion ‘‘Setting interfac e op tions on 7400A DCE’’ (ab ove), you are finished c onfiguring the 7400A data module. Setting the automatic-answer feature on 7400A DCE You c an set up the 7400A d ata mod ule to automatic ally answer c alls or you c an have it ig nore c alls until an op erator answers manually. Set up the d ata mod ule for automatic answering unless sp ec ific ally d irec ted to otherwise. 1. When the SET ANSWER? p romp t app ears, press the ENTER/YES b utton. 2. When the ANS = AUTO? p romp t ap p ears, if you want to enab le automatic answering , p ress the ENTER/YES b utton. Otherwise, p ress the NEXT/NO b utton. 3. If you pressed NEXT/NO in the p rec ed ing step , the ANS —> MANUAL? p rompt ap p ears. If you want to d isab le automatic answering , p ress the ENTER/YES b utton. Otherwise, p ress the NEXT/NO b utton. SET 19200 SPEED? DATANEXT/NO BACK ENTER/YES lÜ l m m Push the b utton ind ic ated b y the arrow (Ü ) SET ANSWER? DATANEXT/NO BACK ENTER/YES l mmÜ l Push the b utton ind ic ated b y the arrow (Ü ) ANS = AUTO? DATANEXT/NO BACK ENTER/YES l mm m Se le c t a n o p t i o n ( N EXT/ N O o r EN TER/ YES) ANS —> MANUAL? DATANEXT/NO BACK ENTER/YES l mm m Se le c t a n o p t i o n ( N EXT/ N O o r EN TER/ YES)
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 Data Modules and Asynchronous Data Units 43 Connect Data Modules 4 4. The CONTINUE? prompt appears. Press the ENTER/YES b utton. Setting the break-disconnect option on 7400A DCE This setting sp ec ifies the leng th of the BREAK sig nal, a string of 10 or more sp ac es that tells the host that the user need s to interrup t op erations. There are three options: TRIPLE, LONG (the d efault), and NONE. Ac c ep t the d efault values, unless otherwise instruc ted . 1. When the SET BREAK DISC? prompt appears, press the NEXT/NO b utton to keep the d efault. Configuring the RS-232 interface on 7400A DCE You c an set eac h pin of the RS-232 c ab le to meet the need s of sp ec ific ap p lic ations or c onnec ted eq uip ment. however, in most c ases, you c an use the d efaults. To set the EIA lead s, p roc eed as follows: 1. When the SET LeadName LEAD? p romp t ap p ears, press the NEXT/NO b utton to keep the d efault or the ENTER/YES b utton to make a c hang e. CONTINUE? DATANEXT/NO BACK ENTER/YES l mmÜ l Push the b utton ind ic ated b y the arrow (Ü ) SET BREAK DISC? DATANEXT/NO BACK ENTER/YES lÜ l m m Push the b utton ind ic ated b y the arrow (Ü ) SET LeadName LEAD? DATANEXT/NO BACK ENTER/YES lÜ l m m Push the b utton ind ic ated b y the arrow (Ü )
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 Data Modules and Asynchronous Data Units 44 Connect Data Modules 4 2. If you pressed the ENTER/YES b utton at the SET LeadName LEAD? prompt, the LeadName -> ON? p rompt ap p ears. Press the ENTER/YES b utton. 3. Rep eat until all lead s have b een set. Setting parity on 7400A DCE Next you need to id entify the type of p arity c od ing that the d ata mod ule should exp ec t. Parity is an error-d etec tion sc heme that is b ased on the value of a p arity b it in eac h unit of information. Four c od ing sc hemes are used : ODD , EVEN , MARK , and SPACE . In odd -p arity c od ing , the p arity b it is set to 0 if the numb er of 1s in the information is od d , 1 if it is even. In even-p arity c od ing , the p arity b it is set to 0 if the numb er of 1s in the information is even, 1 if it is od d . Mark-p arity c od ing always sets the p arity b it to 1. Sp ac e-p arity c od ing always sets the p arity b it to 0. 1. Ac c ep t the d efault value, unless otherwise instruc ted . When the SET PARITY? p romp t ap p ears, press the NEXT/NO b utton to keep the default, SPACE . Enabling remote loopback testing on 7400A DCE You c an set the remote loop b ac k option to GRANT or DENY . 1. Ac c ep t the d efault value, unless otherwise instruc ted . When the SET REMOTE LOOP? p romp t app ears, p ress the NEXT/NO b utton to keep the d efault, GRANT . LeadName -> ON? DATANEXT/NO BACK ENTER/YES l m m Ü l Push the b utton ind ic ated b y the arrow (Ü ) SET PARITY? DATANEXT/NO BACK ENTER/YES lÜ l m m Push the b utton ind ic ated b y the arrow (Ü ) SET REMOTE LOOP? DATANEXT/NO BACK ENTER/YES lÜ l m m Push the b utton ind ic ated b y the arrow (Ü )
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 Data Modules and Asynchronous Data Units 45 Connect Data Modules 4 Configuring the ring indicator on 7400A DCE The ring -ind ic ator (p in 22) setting c an have either of two values: CYCLE or ON (the d efault). 1. Ac c ep t the d efault values, unless otherwise instruc ted . When the SET RI LEAD? promp t ap p ears, p ress the NEXT/NO b utton to keep the d efault, ON. Enabling remote loopback on 7400A DCE The remote-loop b ac k setting (p in 21) c an have either of two values: ON or OFF (the d efault). 1. Ac c ep t the d efault values, unless otherwise instruc ted . When the SET RL LEAD? promp t ap p ears, p ress the NEXT/NO b utton to keep the d efault, ON . Setting the signals-disconnect (SIGLS DISC) option on 7400A DCE The setting s c an have either of two values: ON (the d efault) or OFF . Ac c ep t the d efault values, unless otherwise instruc ted . 1. When the SET SIGLS DISC? prompt appears, press the NEXT/NO b utton to keep the d efault, ON . SET RI LEAD? DATANEXT/NO BACK ENTER/YES lÜ l m m Push the b utton ind ic ated b y the arrow (Ü ) SET RL LEAD? DATANEXT/NO BACK ENTER/YES lÜ l m m Push the b utton ind ic ated b y the arrow (Ü ) SET SIGLS DISC? DATANEXT/NO BACK ENTER/YES lÜ l m m Push the b utton ind ic ated b y the arrow (Ü )
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 Data Modules and Asynchronous Data Units 46 Connect Data Modules 4 Enabling test mode on 7400A DCE The test-mode (p in 25) setting c an have either of two values: ON or OFF (the d efault). 1. Ac c ep t the d efault values, unless otherwise instruc ted . When the SET TM LEAD? promp t ap p ears, p ress the NEXT/NO b utton to keep the d efault, ON . Exiting menus and saving changes on 7400A DCE 1. When the DONE? promp t ap p ears, p ress the ENTER/YES b utton. 2. When the SAVE CHANGES? p romp t ap p ears, p ress the ENTER/YES b utton. Your c hang es are saved . SET TM LEAD? DATANEXT/NO BACK ENTER/YES lÜ l m m Push the b utton ind ic ated b y the arrow (Ü ) DONE? DATANEXT/NO BACK ENTER/YES l m m Ü l Push the b utton ind ic ated b y the arrow (Ü ) SAVE CHANGES? DATANEXT/NO BACK ENTER/YES l m m Ü l Push the b utton ind ic ated b y the arrow (Ü ) CHANGES SAVED DATANEXT/NO BACK ENTER/YES l m m Ü l Push the b utton ind ic ated b y the arrow (Ü )
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 Data Modules and Asynchronous Data Units 47 Connect Data Modules 4 You return HOME. Checking DEFINITY administration on 7400A DCE Chec k that the DEFINITY is ad ministered to sup p ort the 7400A d ata mod ule in the DCE ap p lic ation as follows: 1. If nec essary, return to the HOME d isp lay on the 7400A b y p ressing the NEXT/NO and BACK buttons at the same time. 2. From the HOME d isp lay, p ress NEXT/NO until ANS/ORIG CALL? is d isp layed , then p ress the ENTER/YES b utton. 3. If you see the messag e WAITING ... DISCONNECTED , the switc h has not b een ad ministered c orrec tly. 4. If you see the messag e DIAL TONE followed b y DISCONNECT CALL? , the DEFINITY is c orrec tly ad ministered for the 7400A data mod ule. Press the ENTER/YES b utton to return to the menu. The 7400A rep lies WAITING ... DISCONNECTED and returns to the ANS/ ORIG CALL? menu. 5. Return to the HOME d isp lay b y p ressing the NEXT/NO and BACK b uttons at the same time. Configuring the 7400A for modem pooling (DTE) applications From the HOME sc reen, p roc eed as follows. Setting speed options on 7400A DTE 1. To ac c ess the menus, p ress the NEXT/NO b utton. D T RD S RR ID C DR T SC T ST DR D HOME POWER TEST———0 ———— DATA NEXT/NO BACK ENTER/YES l7400A Data Modulel mm m
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 Data Modules and Asynchronous Data Units 48 Connect Data Modules 4 2. When the SET OPTIONS? p romp t ap p ears on the LCD, p ress the ENTER/ YES button. A series of SET number SPEED? prompts appears. 3. Press the NEXT/NO b utton until you see the SET 9600 SPEED? p romp t. Then press the ENTER/YES b utton. Most DEFINITY c onnec tions op erate at the 9600 sp eed . 4. The 9600 = OFF? prompt appears. Press the NEXT/NO b utton. 5. The 9600 —> ON? p romp t ap pears. Press the ENTER/YES b utton. D T RD S RR ID C DR T SC T ST DR D HOME POWER TESTSET OPTIONS? DATANEXT/NO BACK ENTER/YES l7400A Data Modulel Ü l m m Push the b utton indic ated b y the arrow (Ü ) SET 9600 SPEED? DATA NEXT/NO BACK ENTER/YES l mmÜ l Push the b utton ind ic ated b y the arrow (Ü ) 9600=OFF? DATANEXT/NO BACK ENTER/YES lÜ l m m Push the b utton ind ic ated b y the arrow (Ü ) 9600 —> ON? DATANEXT/NO BACK ENTER/YES lmmÜ l Push the b utton ind ic ated b y the arrow (Ü )