Have a look at the manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation For Adjuncts And Peripherals Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 DS1/T1 CPE Loopback Jack 119 Loopback Testing with a Smart Jack 9 5. End the test. Enter test DS1-loop location end cpe-loopback-jack-test 6. Wait ab out 30 sec ond s for the DS1 to reframe on the inc oming sig nal and c lear DS1 fac ility alarms. Condition Solution The value of the Bit-error count field is g reater than 1Rep lac e the ICSU, and retest. The value of the Bit-error count field is still g reater than 1 after you rep lac e the ICSU.Rep lac e the DS1 c irc uit p ac k, and retest. The value of the Bit-error count field is 1 The test p assed . Condition Solution Loop bac k termination fails with an error c od e of 1313. The sp an is still loop ed somewhere, p ossib ly at the loop b ac k jac k, at the ICSU, or somewhere in the network. The red LED on the loop b ac k jac k is on. Rep lac e the ICSU, and re-run the test. Loop bac k termination still fails.Replace the DS1 circ uit pack, and repeat the test The DS1 c annot frame on the inc oming sp an’s sig nal after the loopback jack power down. There is something wrong with the rec eive sig nal into the loop b ac k jac k from the d umb b loc k or the smart jac k. The sp an failed the servic e provider’s loopback test.The p rob lem is in the servic e p rovid er’s network. The servic e p rovider suc c essfully loop tested the sp an, up to the smart jac k.The wiring between the loop b ac k jac k and the smart jac k is susp ec t. Test, and make rep airs, as need ed . You c annot loc ate and rep air the p rob lem in the time availab le and must termnate the test.The test will not terminate normally in the ab senc e of a g ood framing sig nal. You have to reset the c irc uit p ac k. En t e r reset board UUCSS where UU is the c ab inet numb er, C is the c arrier numb er, and SS is the slot numb er of the DS1 b oard . The test terminated normally. Proc eed with ‘‘Restoring DS1 ad ministration’’ , below.
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 DS1/T1 CPE Loopback Jack 120 Loopback Testing with a Smart Jack 9 Restoring DS1 administration 1. At the manag ement terminal, op en the DS1 ad ministration form. Enter change DS1 UUCSS where UU is the c abinet numb er, C is the c arrier number, and SS is the slot number of the DS1 b oard . 2. Chang e to p ag e 2 of the DS1 ad ministration form. 3. Change the value of the TX LBO field to the orig inal value that you wrote d own when you were ‘‘Ad ministering the DS1 for the test’’ on p ag e 116 . 4. Press EN TER to make the c hang es, CANCEL to q uit without c hang es. Releasing the DS1 circuit pack 1. Release the DS1 c irc uit pack. From the management terminal, enter release board UUCSS where UU is the c abinet numb er, C is the c arrier number, and SS is the slot number of the DS1 b oard . 2. Leave the loop b ac k jac k in p lac e. Testing the DS1 Span from the Smart Jack to the Network Interface Termination or Fiber Multiplexer (MUX) 1. Have the servic e p rovid er run a smart-jac k loop b ac k test ag ainst the network interfac e wiring that links the smart jac k to the CO (Sec tion 3 in Fi g u re 3 4 ). 2. If the tests fails, there is a p rob lem on the network sid e. Have the servic e p rovid er c orrec t it. Testing the DS1 Span from the Loopback Jack to the Smart Jack Test the short leng th of c ustomer p remises wiring b etween the loopb ac k jac k and the smart jac k (Sec tion 2 in the following 3 fig ures) using a loop b ac k that overlaps this sec tion of the sp an. n Have the DS1 servic e p rovid er at the CO end run a loc al ICSU line loopback test. n Have the DS1 servic e p rovid er at the CO end run a loc al DS1 p ayload loopback test. n Run a far-end ICSU line loopb ac k, using the proc ed ure below.
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 DS1/T1 CPE Loopback Jack 121 Loopback Testing with a Smart Jack 9 NOTE: This test c annot isolate the p roblem if there are p roblems in the wiring b etween the far-end CO and the far-end ICSU. You must c oord inate this test with the DS1 servic e p rovider. 1. From the manag ement terminal, enter test DS1-loop UUCSS far-csu-loopback-test-begin where UU is the c abinet numb er,C is the carrier number, and SS is the slot numb er of the DS1 board . 2. Examine the b it-eror c ounts, as in ‘‘Testing the integrity of data sent over the loop ’’ on p ag e 117. 3. Terminate the test. Enter test DS1-loop location end-loopback/span-test . 3. If the tests fails and the there were no p rob lems ‘‘Testing the DS1 Span from the ICSU to the Loop b ac k Jac k’’ or ‘‘Testing the DS1 Sp an from the Smart Jac k to the Network Interfac e Termination or Fib er Multip lexer (MUX)’’, there is a p rob lem b etween the loop b ac k jac k to the smart jac k. Work with the servic e p rovider to isolate the fault. Figure 34. Network Interface at Smart Jack1. Span section 1 2. Span section 2 3. Span section 3 4. 120A2 (or later) ICSU 5. RJ-48 to network interfac e (up to 1000 ft [ 305 m] )6. Loop b ac k jac k 7. Network interfac e smart jac k 8. Interfac e termination or fib er multip lexer (MUX) 9. Central offic e
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 DS1/T1 CPE Loopback Jack 122 Loopback Testing with a Smart Jack 9 Figure 35. Network Interface at Extended Demarcation Point (Smart Jack Inaccessible)1. Sp an sec tion 1 2. Sp an sec tion 2 3. Sp an sec tion 3 4. 120A2 (or later) ICSU 5. RJ-48 to network interfac e (up to 1000 ft [305 m] )6. Loop b ac k jac k 7. Dumb b loc k (extend ed d emarc ation) 8. Network interfac e smart jac k 9. Interfac e termination or fib er multip lexer (MUX) 10. Central offic e
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 DS1/T1 CPE Loopback Jack 123 Loopback Testing Without a Smart Jack 9 Figure 36. Network Interface at Extended Demarcation Point (Smart Jack Accessible) Loopback Testing Without a Smart Jack When the loop b ac k jac k is ad ded to a span that d oes not c ontain a smart jac k, the sp an is d ivid ed into 2 sec tions: from the ICSU to the loop b ac k jac k and from the loop b ac k jac k to the c entral offic e (CO). Sec tion 2 inc lud es the short c ab le from the loop b ac k jac k to the d umb b loc k d emarc ation p oint (p art of the loop b ac k jac k). This c ab le is the only p art of Sec tion 2 that is part of c ustomer p remises wiring . It is not c overed in the loop b ac k jac k’s loop b ac k path. See Fi g u re 3 7 and Fi g u re 3 8. 1. Sp an sec tion 1 2. Sp an sec tion 2 3. Sp an sec tion 3 4. 120A2 (or later) ICSU 5. RJ-48 to network interfac e (up to 1000 ft [ 305 m] )6. Loop b ac k jac k 7. Dumb b loc k (extend ed d emarc ation) 8. Network interfac e smart jac k 9. Interfac e termination or fib er multip lexer (MUX) 10. Central offic e 11. Dumb b loc k to smart jac k RJ-48
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 DS1/T1 CPE Loopback Jack 124 Loopback Testing Without a Smart Jack 9 Figure 37. Network Interface at “Dumb” Block1. Sp an sec tion 1 2. Sp an sec tion 2 3. 120A2 (or later) ICSU 4. RJ-48 to network interfac e (up to 1000 ft [ 305 m] )5. Loopback jack 6. Dumb b loc k (d emarc ation p oint) 7. Interfac e termination or fib er multiplexer (MUX) 8. Central office
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 DS1/T1 CPE Loopback Jack 125 Loopback Testing Without a Smart Jack 9 Figure 38. Network Interface at “Dumb” Block with Repeater Line to Fiber MUX You are resp onsib le for find ing and c orrec ting p rob lems in the c ustomer wiring (sec tion 1 and the loop b ac k c ab le p ortion of sec tion 2). The DS1 servic e p rovid er is resp onsib le for find ing and c orrec ting p rob lems in the majority of sec tion 2. Proc eed as follows. 1. Test c ustomer p remises wiring from the ICSU to the loop b ac k jac k, as d esc rib ed in the “ DS1 Sp an Test” sec tion. 2. Test the loop b ac k jac k-to-dumb block and dumb block-to-CO wiring (sec tion 2 in Fi g u re 3 7 ). This c an b e d one using a loop bac k that “ overlap s” the sec tion of the sp an. Any of the following loop b ac ks c an d o this: n The loc al ICSU’s line loop b ac k, whic h the DS1 servic e provid er at the CO end typ ic ally ac tivates, tests, and then d eac tivates. n The local DS1 interface’s payload loopback, which the DS1 service p rovid er at the CO end ac tivates and tests. 1. Sp an sec tion 1 2. Sp an sec tion 2 3. 120A2 (or later) ICSU 4. RJ-48 to network interfac e (up to 1000 ft [305 m]) 5. Loop b ac k jac k6. Dumb b loc k (d emarc ation p oint) 7. Repeater 8. Fiber multip lexer (MUX) 9. Central office
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 DS1/T1 CPE Loopback Jack 126 Loopback Testing Without a Smart Jack 9 n The far-end ICSU’s line loop b ac k. Ac tivate this test at the manag ement terminal b y entering test DS1-loop location far-csu- loopback-test-begin . Terminate this test b y entering test DS1-loop location end-loopback/span-test . Bit error c ounts are examined as desc rib ed in the “ DS1 Sp an Test” sec tion. This test only isolates p rob lems to Sec tion 2 wiring if there are no p rob lems in the wiring b etween the far-end CO and the far-end ICSU. Coord inate this test with the DS1 servic e p rovid er. Failure of any of the ab ove tests (a, b , or c ) ind ic ate a prob lem in Section 2. This could mean bad loopback jack -to-”dumb” block c ab ling, b ut is more likely to ind ic ate a p rob lem somewhere b etween the “ d umb ” b loc k and the CO. This is the resp onsib ility of the DS1 service provider. If the DS1 Sp an Test c onfirms that there are no p rob lems in Sec tion 1, the tec hnic ian should p roc eed as follows to avoid unnec essary dispatch. 1. Id entify and c ontac t the DS1 servic e p rovid er. 2. Inform the DS1 p rovid er that loop b ac k tests of the CPE wiring to the “ d umb” b loc k (sec tion 1) showed no p rob lems. 3. If the far-end ICSU line loop b ac k test failed, inform the DS1 provider. 4. Req uest that the DS1 p rovid er p erform a loopb ac k test of their p ortion of the Sec tion 2 wiring b y send ing someone out to loop Sec tion 2 b ac k to the CO at the “ d umb ” b loc k. If this test fails, the p rob lem is in the servic e p rovid er’s wiring . If the test p asses, the p rob lem is in the c ab le between the loop b ac k jac k and the “ d umb” b loc k. Rep lac e the loop b ac k jac k. Configurations Using Fiber Multiplexers Use the loop b ac k jac k when c ustomer p remises DS1 wiring c onnec ts to an on- site fib er multip lexer (MUX) and allows wiring to the network interfac e p oint on the MUX to b e remotely tested . This req uires that ICSUs b e used on DS1 wiring to the MUX. Fiber MUXs c an take the p lac e of Interfac e termination feed s as shown in Fi g u re 34, Fi g u re 3 5, Fig ure 36, and Fi g u re 3 7. Test these sp ans using the same p roc ed ures as metallic sp ans. Note the following p oints: 1. Fiber MUXs may have loop b ac k c ap ab ilities that c an the servic e p rovid er c an ac tivate from the CO end. These may loop the signal b ac k to the CO or b ac k to the DS1 b oard . If the MUX p rovid es the eq uivalent of a line
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 DS1/T1 CPE Loopback Jack 127 Loopback Testing Without a Smart Jack 9 loop b ac k on the “ p rob lem” DS1 fac ility, ac tivate it after a suc c essful loop b ac k jac k test, and use it to isolate p rob lems to the wiring b etween the loop b ac k jac k and the MUX. 2. Be aware that there are installations that use rep eatered metallic lines b etween the MUX and the “ d umb ” b loc k. These lines req uire DC power for the rep eaters and this DC p ower is p resent at the “ d umb ” b loc k interfac e to the CPE eq uip ment. A loopb ac k jac k is req uired in this c onfig uration to p rop erly isolate and terminate the DC p ower. To c hec k for the p resenc e of DC, make the following 4 measurements at the network interfac e jac k: 1. From transmit tip (T, Pin 5) to rec eive tip (T1, Pin 2) 2. From transmit ring (R, Pin 4) to rec eive ring (R1, Pin 4) 3. From transmit tip (T, Pin 5) to transmit ring (R, Pin 4) 4. From rec eive tip (T1, Pin 2) to rec eive ring (R1, Pin 4) All measurements should read 0 (zero) volts DC. For p in numb ers and p in designations, refer to Integ rated Channel Servic e Unit (ICSU) Installation and Operation. Operating Characteristics If a TN464F or TN767E and a 120A2 were installed in a system running pre- DEFINITY ECS, V3 software and the software is later up g rad ed to DEFINITY ECS, V3 Release 3 or later, remove and re-install the DS1 c irc uit pac k so that the ICSU ad ministration field s will ap p ear on the DS1 ad ministration sc reen.
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 DS1/T1 CPE Loopback Jack 128 Loopback Testing Without a Smart Jack 9