Have a look at the manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation For Adjuncts And Peripherals Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 Multimedia Communications Products: MMCX, MMCH, ESM 189 Multimedia Call Handling (MMCH) 18 7. Set the Signaling Mode: field to isdn-pri 8. Set the Connect: field to pbx 9. Set the Interface: field to network 10. Set the Country Protocol:field to 1 11. Set the Protocol Version: field to a 12. Set the CRC?: field to y 13. The Id le Cod e d efault is 11111111. 14. The DCP/Analog Bearer Cap ab ility d efault is 3.1 kHz. 15. Set the MMI Cabling Board: field to xxxxx (where xxxxx is the loc ation of the TN787F/H/J/K MMI c irc uit p ac k rec ord ed in step 2). This must b e the slot for p ort B of the Y-c ab le. 16.The MMI Interface: field ESM ap p ears. 17. Enter add signaling-group next and the signaling-group form appears. 18. Chang e Associated Signaling : field to y. 19. Chang e Primary D-Channel Port : field to xxxx17 (where xxxx is the ad d ress of the TN2207 PRI c irc uit p ac k, for examp le: 1B0517). 20. The Max Number of NCA TSC : d efault is 0. 21. The Max Number of GA TSC : d efault is 0. 22.Trunk Group for NCA TSC : ____ ( l e a v e b l a n k ) 23.Trunk Group for Channel Selection :____ (leave b lank) 24. Log off the terminal and then log b ac k on the terminal to view your changes. Place Test Call Plac e multimed ia data-c onferenc e c all to an end p oint with known vid eo c ap ability to test the esm func tion. Troubleshooting To d etermine ESM link status enter the following c ommand s from the system ad ministration terminal: 1. Status esm 2. Status signaling-group 3. List MMI
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 Multimedia Communications Products: MMCX, MMCH, ESM 190 Multimedia Call Handling (MMCH) 18 NOTE: When you move ESM circuit p ac ks, you MUST remove the DS1 and sig naling g roup translations. You c annot use the change circuit pack c ommand . Refer to ‘‘Setup and Test the MMCH Installation’’ on p ag e 180 for further information.
Property Management System 191 Connecting the Property Management System 19 DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 19 Property Management System This c hapter p rovid es information on c onnec ting the prop erty manag ement system and a terminal, journal p rinter, or both. Connecting the Property Management System A d ata mod ule and an async hronous d ata unit form the interfac e between the DEFINITY and the prop erty manag ement system (PMS). See Fi g u re 6 6 and Chapter 4, ‘‘Data Mod ules and Async hronous Data Units’’ , for c onnec tion and c onfig uration information.
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 Property Management System 192 Connecting a Terminal and/or Journal Printer 19 Figure 66. Connections to Asynchronous Data Unit Connecting a Terminal and/or Journal Printer You c an c onnec t c ustomer d ata terminals, host c omp uters, and /or an op tional journal p rinter in either of two ways. Using Data Modules 1. Config ure p rinter or terminal in ac c ord anc e with the rec ommend ations in the vend or’s d oc umentation. 2. Config ure the d ata mod ule for the p rinter or terminal, using the instruc tions in Chap ter 4, ‘‘Data Modules and Async hronous Data Units’’ . 1. Z3A1 or Z3A2 ADU 2. 4-pair line cord 3. 103A or modular wall jac k 4. Analog telep hone 5. Satellite site or ad ap ter loc ation 6. Station side blue or white field 7. System sid e 8. Data mod ule 9. TXT10. TXR 11. PXT 12. PXR 13. Tip 14. Ring 15. To analog line c irc uit p ac k 16. To d ata line c irc uit p ac k 17. 25-p in RS-232-D c onnec tor (male) 18. Main d istrib ution frame 2 2 3 9101011111212 6 8 1415 LINEV. 3 5POWER RS-366/RS-232 6 9 137 0002_1 RBP 062596 1
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 Property Management System 193 Connecting a Terminal and/or Journal Printer 19 3. Id entify the p ort assoc iated with the d ata unit or d ata mod ule using the Data Mod ule Form (see ‘‘Ad minister the DEFINITY ECS for Data Mod ules’’ on pag e 73). 4. Estab lish a p hysic al c onnec tion from the d ata p ort on the c irc uit p ac k, throug h the MDF, to the wall jac k where the d ata unit is installed . 5. Connec t the d ata mod ules to the eq uipment. Using an Asynchronous Data Unit (ADU) and a Data Line Circuit Pack You c onnec t an async hronous d ata terminal throug h an ADU to a d ata line c irc uit p ac k. Normally, the c onnec ted d ata terminal powers the d ata unit. The d ata unit c an also b e remotely or loc ally powered using a 2012D transformer with a 248B ad ap ter. Data units c onnec ted to rec eive-only p rinters req uire external p ower. 1. Config ure p rinter or terminal in ac c ord anc e with the rec ommend ations in the vend or’s d oc umentation. 2. Id entify the p ort assoc iated with the d ata unit or d ata mod ule using the Data Mod ule Form (see ‘‘Ad minister the DEFINITY ECS for Data Mod ules’’ on pag e 73). 3. Estab lish a p hysic al c onnec tion from the d ata p ort on the c irc uit p ac k, throug h the MDF, to the wall jac k where the d ata unit is installed . 4. Connec t the information outlet to the ADU. 5. Connec t the RS-232 p lug on the ADU or data mod ule to the d ata terminal. 6. Connec t the p rinter to the ADU via a mod em or d ata mod ule, using the instruc tions in Chapter 4, ‘‘Data Mod ules and Async hronous Data Units’’ , and Chap ter 5, ‘‘External Mod ems’’ .
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 Property Management System 194 Connecting a Terminal and/or Journal Printer 19
Connector and Cable Pinout Charts 195 A DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 A Connector and Cable Pinout Charts Table 31. Lead and Color Designations Cross-Connect Pin ColorAmphenol Pin Backplane Pin 1W-BL27102 2 BL-W 01 002 3 W-O 27 103 4 O-W 02 003 5 W-G 28 104 7 G-W 03 004 7W-BR29105 8BR-W04005 9W-SL30107 10 SL-W 05 007 11 R-BL 31 107 12 BL-R 07 007 13 R-O 32 108 14 O-R 07 008 15 R-G 33 109 17 G-R 08 009 Continued on next page
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 Connector and Cable Pinout Charts 196 A 17 R-BR 34 110 18 BR-R 09 010 19 R-SL 35 111 20 SL-R 10 011 21 BK-BL 37 112 22 BL-BK 11 012 23 BK-O 37 113 24 O-BK 12 013 25 BK-G 38 302 27 G-BK 13 202 27 BK-BR 39 303 28 BR-BK 14 203 29 BK-SL 40 304 30 SL-BK 15 204 31 Y-BL 41 305 32 BL-Y 17 205 33 Y-O 42 307 34 O-Y 17 207 35 Y-G 43 307 37 G-Y 18 207 37 Y-BR 44 308 38 BR-Y 19 208 3 9 Y- SL 4 5 3 0 9 40 SL-Y 20 209 41 V-BL 47 310 42 BL-V 21 210 43 V-O 47 311 44 O-V 22 211 45 V-G 48 312 Table 31. Lead and Color Designations Cross-Connect Pin ColorAmphenol Pin Backplane Pin Continued on next page
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 Connector and Cable Pinout Charts 197 A 47 G-V 23 212 47 V-BR 49 313 48 BR-V 24 213 4 9 V- SL 5 0 3 0 0 50 SL-V 25 200 Table 32. DS1 Interface cable H600-348 50-Pin 15-Pin Pin Color Designation Pin Color Designation Plug 04 38 W-BL LI (Hig h) 11 W-BL LI (Hig h) 13 BL-W LI 03 BL-W LI 39 W-O LO 09 W-O LO 14 O-W LO (Hig h) 01 O-W LO (Hig h) Plug 03 41 W-G LI (Hig h) 11 W-G LI (Hig h) 17 G-W LI 03 G-W LI 42 W-BR LO 09 W-BR LO 17 BR-W LO (Hig h) 01 BR-W LO (Hig h) Plug 02 44 W-SL LI (Hig h) 11 W-SL LI (Hig h) 19 SL-W LI 03 SL-W LI 45 R-BL LO 09 R-BL LO 20 BL-R LO (Hig h) 01 BL-R LO (Hig h) Plug 01 47 R-O LI (Hig h) 11 R-O LI (Hig h) Continued on next page Table 31. Lead and Color Designations Cross-Connect Pin ColorAmphenol Pin Backplane Pin Continued on next page
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 Connector and Cable Pinout Charts 198 A 22 O-R LI 03 O-R LI 48 R-G LO 09 R-G LO 23 G-R LO (Hig h) 01 G-R LO (Hig h) Table 33. DS1 Interface Cable H600-307 50-Pin 15-Pin Pin Color Designation Pin Color Designation 02 W-BL 03 BL-W 47 W-G LI (Hig h) 11 W-G LI (Hig h) 22 G-W LI 03 G-W LI 48 W-BR LO 09 W-BR LO 23 BR-W LO (Hig h) 01 BR LO (Hig h) 49 W-SL LOOP2 07 W-SL LOOP2 24 SL-W LOOP1 05 SL-W LOOP1 All other p ins empty. Table 34. TN2185B ISDN-BRI — 4-Wire S Interface Pinout Port Signal Cross-Connect Pin ColorAmpheno l Pin Backplane Pin 1 TXT.1 1 W-BL 27 102 TXR.1 2 BL-W 01 002 PXT. 1 3 W- O 2 7 1 0 3 PXR. 1 4 O -W 0 2 0 0 3 Continued on next page Table 32. DS1 Interface cable H600-348 50-Pin 15-Pin Pin Color Designation Pin Color Designation Continued on next page