    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation For Adjuncts And Peripherals Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							DEFINITY ECS Release 8.2
    Installation for Adjuncts and Peripherals  555-233-116  Issue 1
    April 2000
    Multimedia Communications Products: MMCX, MMCH, ESM 
    189 Multimedia Call Handling (MMCH) 
    18
    7. Set the Signaling Mode:
     field  to isdn-pri
    8. Set the Connect:
     field  to pbx
    9. Set the Interface:
     field to network
    10. Set the Country Protocol:field
     to 1
    11. Set the Protocol Version:
    field  to a
    12. Set the CRC?:
    field to y
    13. The Id le Cod e d efault is 11111111.
    14. The DCP/Analog  Bearer Cap ab ility d efault is 3.1 kHz.
    15. Set the MMI Cabling Board: 
    field  to xxxxx 
    (where xxxxx is the 
    loc ation of the TN787F/H/J/K MMI c irc uit p ac k rec ord ed  in step  2). This 
    must b e the slot for p ort B of the Y-c ab le.
    16.The MMI Interface: field ESM 
    ap p ears.
    17. Enter add signaling-group next
     and the signaling-group form appears.
    18. Chang e Associated Signaling
    : field  to y.
    19. Chang e Primary D-Channel Port
    : field  to xxxx17
     (where xxxx is the 
    ad d ress of the TN2207 PRI c irc uit p ac k, for examp le: 1B0517).
    20. The Max Number of NCA TSC
    : d efault is 0.
    21. The Max Number of GA TSC
    : d efault is 0.
    22.Trunk Group for NCA TSC
    :  ____ ( l e a v e  b l a n k )
    23.Trunk Group for Channel Selection
    :____ (leave b lank)
    24. Log off the terminal and  then log  b ac k on the terminal to view your 
    changes.
    Place Test Call
    Plac e multimed ia data-c onferenc e c all to an end p oint with known vid eo 
    c ap ability to test the esm func tion.
    Troubleshooting
    To d etermine ESM link status enter the following  c ommand s from the system 
    ad ministration terminal:
    1. Status esm
    2. Status signaling-group
    3. List MMI 
    						
    							DEFINITY ECS Release 8.2
    Installation for Adjuncts and Peripherals  555-233-116  Issue 1
    April 2000
    Multimedia Communications Products: MMCX, MMCH, ESM 
    190 Multimedia Call Handling (MMCH) 
    18
    NOTE:
    When you move ESM circuit p ac ks, you MUST remove the DS1 and  
    sig naling  g roup  translations. You c annot use the change circuit pack 
    c ommand .
    Refer to ‘‘Setup  and  Test the MMCH Installation’’ on p ag e 180
     for further 
    information. 
    						
    							Property Management System 
    191 Connecting the Property Management System 
    19
    DEFINITY ECS Release 8.2
    Installation for Adjuncts and Peripherals  555-233-116  Issue 1
    April 2000
    19
    Property Management System
    This c hapter p rovid es information on c onnec ting  the prop erty manag ement 
    system and  a terminal, journal p rinter, or both.
    Connecting the Property 
    Management System 
    A d ata mod ule and  an async hronous d ata unit form the interfac e between the 
    DEFINITY and the prop erty manag ement system (PMS).  See Fi g u re  6 6
     and 
    Chapter 4, ‘‘Data Mod ules and  Async hronous Data Units’’
    , for c onnec tion and  
    c onfig uration information. 
    						
    							DEFINITY ECS Release 8.2
    Installation for Adjuncts and Peripherals  555-233-116  Issue 1
    April 2000
    Property Management System 
    192 Connecting a Terminal and/or Journal Printer 
    19
    Figure 66. Connections to Asynchronous Data Unit
    Connecting a Terminal and/or Journal 
    Printer
    You c an c onnec t c ustomer d ata terminals, host c omp uters, and /or an op tional 
    journal p rinter in either of two ways.
    Using Data Modules 
    1. Config ure p rinter or terminal in ac c ord anc e with the rec ommend ations in 
    the vend or’s d oc umentation. 
    2. Config ure the d ata mod ule for the p rinter or terminal, using  the instruc tions 
    in Chap ter 4, ‘‘Data Modules and  Async hronous Data Units’’
    . 1. Z3A1 or Z3A2 ADU
    2. 4-pair line cord
    3. 103A or modular wall jac k
    4. Analog  telep hone
    5. Satellite site or ad ap ter loc ation
    6. Station side blue or white field
    7. System sid e
    8. Data mod ule
    9. TXT10. TXR
    11. PXT
    12. PXR
    13. Tip
    14. Ring  
    15. To analog  line c irc uit p ac k
    16. To d ata line c irc uit p ac k 
    17. 25-p in RS-232-D c onnec tor (male)
    18. Main d istrib ution frame 
    2
    2
    3
    9101011111212
    6
    8
    1415
    LINEV. 3 5POWER RS-366/RS-232
    6
    9
    137
    0002_1 RBP 062596
    1 
    						
    							DEFINITY ECS Release 8.2
    Installation for Adjuncts and Peripherals  555-233-116  Issue 1
    April 2000
    Property Management System 
    193 Connecting a Terminal and/or Journal Printer 
    19
    3. Id entify the p ort assoc iated  with the d ata unit or d ata mod ule using  the 
    Data Mod ule Form (see ‘‘Ad minister the DEFINITY ECS for Data Mod ules’’ 
    on pag e 73).
    4. Estab lish a p hysic al c onnec tion from the d ata p ort on the c irc uit p ac k, 
    throug h the MDF, to the wall jac k where the d ata unit is installed .
    5. Connec t the d ata mod ules to the eq uipment.
    Using an Asynchronous Data Unit (ADU) and a 
    Data Line Circuit Pack
    You c onnec t an async hronous d ata terminal throug h an ADU to a d ata line c irc uit 
    p ac k. Normally, the c onnec ted  d ata terminal  powers the d ata unit. The d ata unit 
    c an also b e remotely or loc ally powered  using a 2012D transformer with a 248B 
    ad ap ter. Data units c onnec ted  to rec eive-only p rinters req uire external p ower. 
    1. Config ure p rinter or terminal in ac c ord anc e with the rec ommend ations in 
    the vend or’s d oc umentation. 
    2. Id entify the p ort assoc iated  with the d ata unit or d ata mod ule using  the 
    Data Mod ule Form (see ‘‘Ad minister the DEFINITY ECS for Data Mod ules’’ 
    on pag e 73).
    3. Estab lish a p hysic al c onnec tion from the d ata p ort on the c irc uit p ac k, 
    throug h the MDF, to the wall jac k where the d ata unit is installed .
    4. Connec t the information outlet to the ADU.
    5. Connec t the RS-232 p lug  on the ADU or data mod ule to the d ata terminal.
    6. Connec t the p rinter to the ADU via a mod em or d ata mod ule, using  the 
    instruc tions in Chapter 4, ‘‘Data Mod ules and  Async hronous Data Units’’
    , 
    and  Chap ter 5, ‘‘External Mod ems’’
    . 
    						
    							DEFINITY ECS Release 8.2
    Installation for Adjuncts and Peripherals  555-233-116  Issue 1
    April 2000
    Property Management System 
    194 Connecting a Terminal and/or Journal Printer 
    19 
    						
    							Connector and Cable Pinout Charts 
    195  
    A
    DEFINITY ECS Release 8.2
    Installation for Adjuncts and Peripherals  555-233-116  Issue 1
    April 2000
    A
    Connector and Cable Pinout Charts
    Table 31. Lead and Color Designations
    Cross-Connect Pin  ColorAmphenol 
    Pin Backplane Pin
    1W-BL27102
    2 BL-W 01 002
    3 W-O 27 103
    4 O-W 02 003
    5 W-G 28 104
    7 G-W 03 004
    7W-BR29105
    8BR-W04005
    9W-SL30107
    10 SL-W 05 007
    11 R-BL 31 107
    12 BL-R 07 007
    13 R-O 32 108
    14 O-R 07 008
    15 R-G 33 109
    17 G-R 08 009
    Continued on next page 
    						
    							DEFINITY ECS Release 8.2
    Installation for Adjuncts and Peripherals  555-233-116  Issue 1
    April 2000
    Connector and Cable Pinout Charts 
    196  
    A
    17 R-BR 34 110
    18 BR-R 09 010
    19 R-SL 35 111
    20 SL-R 10 011
    21 BK-BL 37 112
    22 BL-BK 11 012
    23 BK-O 37 113
    24 O-BK 12 013
    25 BK-G 38 302
    27 G-BK 13 202
    27 BK-BR 39 303
    28 BR-BK 14 203
    29 BK-SL 40 304
    30 SL-BK 15 204
    31 Y-BL 41 305
    32 BL-Y 17 205
    33 Y-O 42 307
    34 O-Y 17 207
    35 Y-G 43 307
    37 G-Y 18 207
    37 Y-BR 44 308
    38 BR-Y 19 208
    3 9 Y- SL 4 5 3 0 9
    40 SL-Y 20 209
    41 V-BL 47 310
    42 BL-V 21 210
    43 V-O 47 311
    44 O-V 22 211
    45 V-G 48 312
    Table 31. Lead and Color Designations
    Cross-Connect Pin  ColorAmphenol 
    Pin Backplane Pin
    Continued on next page 
    						
    							DEFINITY ECS Release 8.2
    Installation for Adjuncts and Peripherals  555-233-116  Issue 1
    April 2000
    Connector and Cable Pinout Charts 
    197  
    A
    47 G-V 23 212
    47 V-BR 49 313
    48 BR-V 24 213
    4 9 V- SL 5 0 3 0 0
    50 SL-V 25 200
    Table 32. DS1 Interface cable H600-348
    50-Pin 15-Pin
    Pin Color Designation Pin Color Designation
    Plug 04
    38 W-BL LI (Hig h) 11 W-BL LI (Hig h)
    13 BL-W LI 03 BL-W LI
    39 W-O LO 09 W-O LO
    14 O-W LO (Hig h) 01 O-W LO (Hig h)
    Plug 03
    41 W-G LI (Hig h) 11 W-G LI (Hig h)
    17 G-W LI 03 G-W LI
    42 W-BR LO 09 W-BR LO
    17 BR-W LO (Hig h) 01 BR-W LO (Hig h)
    Plug 02
    44 W-SL LI (Hig h) 11 W-SL LI (Hig h)
    19 SL-W LI 03 SL-W LI
    45 R-BL LO 09 R-BL LO
    20 BL-R LO (Hig h) 01 BL-R LO (Hig h)
    Plug 01
    47 R-O LI (Hig h) 11 R-O LI (Hig h)
    Continued on next page
    Table 31. Lead and Color Designations
    Cross-Connect Pin  ColorAmphenol 
    Pin Backplane Pin
    Continued on next page 
    						
    							DEFINITY ECS Release 8.2
    Installation for Adjuncts and Peripherals  555-233-116  Issue 1
    April 2000
    Connector and Cable Pinout Charts 
    198  
    A
    22 O-R LI
    03 O-R LI
    48 R-G LO 09 R-G LO
    23 G-R LO (Hig h) 01 G-R LO (Hig h)
    Table 33. DS1 Interface Cable H600-307
    50-Pin 15-Pin
    Pin Color Designation Pin Color Designation
    02 W-BL
    03 BL-W
    47 W-G LI (Hig h) 11 W-G LI (Hig h)
    22 G-W LI 03 G-W LI
    48 W-BR LO 09 W-BR LO
    23 BR-W LO (Hig h) 01 BR LO (Hig h)
    49 W-SL LOOP2 07 W-SL LOOP2
    24 SL-W LOOP1 05 SL-W LOOP1
    All other p ins empty.
    Table 34. TN2185B ISDN-BRI — 4-Wire S Interface Pinout
    Port Signal Cross-Connect Pin  ColorAmpheno
    l Pin  Backplane Pin
    1 TXT.1 1 W-BL 27 102
    TXR.1 2 BL-W 01 002
    PXT. 1 3 W- O 2 7 1 0 3
    PXR. 1 4 O -W 0 2 0 0 3
    Continued on next page
    Table 32. DS1 Interface cable H600-348
    50-Pin 15-Pin
    Pin Color Designation Pin Color Designation
    Continued on next page 
    						
    All Lucent Technologies manuals Comments (0)