Home > Lucent Technologies > Communications System > Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation For Adjuncts And Peripherals Manual

Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation For Adjuncts And Peripherals Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation For Adjuncts And Peripherals Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							DEFINITY LAN Gateway System 
    99 Installing  DEFINITY LAN Gateway in a Single-Carrier Cabinet 
    7
    DEFINITY ECS Release 8.2
    Installation for Adjuncts and Peripherals  555-233-116  Issue 1
    April 2000
    7
    DEFINITY LAN Gateway System
    The DEFINITY LAN Gateway lets DEFINITY exc hang e messag es with LAN 
    c ommunic ations software. The DEFINITY LAN Gateway system is used  in display 
    set mod e only, not in c ontrol link. Use it with the R8r, R8si, or R8c si. Refer to the 
    DEFINITY Communic ations System Generic  3 Installation, Ad ministration and  
    Maintenanc e of CallVisor ASAI over the DEFINITY LAN Gateway for c omplete 
    installation p roc ed ures.
    Use the add subscribers
     command during administration, to prevent a no port 
    available 
    error. When ad ministration is c omp lete, enter reset system reboot
     to 
    c lear all alarms.
    Installing  DEFINITY LAN Gateway in
    a Single-Carrier Cabinet 
    The DEFINITY LAN Gateway system installs in five ad jac ent slots, p referab ly the 
    five rig htmost slots in a Sing le-Carrier Cab inet. See Fi g u re  2 5
    . 
    !CAUTION:
    Do not p ower up  the DEFINITY LAN Gateway System until instruc ted  to d o 
    so. Refer to the DEFINITY Communic ations System Generic  3 Installation, 
    Ad ministration and  Maintenanc e of CallVisor ASAI over the DEFINITY LAN 
    Gateway.
    It is not nec essary to p ower d own a system b efore installing  a DEFINITY LAN 
    Gateway. 
    						
    							DEFINITY ECS Release 8.2
    Installation for Adjuncts and Peripherals  555-233-116  Issue 1
    April 2000
    DEFINITY LAN Gateway System 
    100 Installing  DEFINITY LAN Gateway in a Single-Carrier Cabinet 
    7
    !CAUTION:
    When the assembly is inserted , it will automatic ally p ower up  (inc lud ing  the 
    d isk), run d iag nostic s, and  b oot. Therefore, to avoid a d isk c rash, never 
    remove the assemb ly and  never p ower d own the DEFINITY System without 
    first shutting  down the unit and  allowing  the d isk to c omp letely sp in d own.
    NOTE:
    The system treats a DEFINITY LAN Gateway like a d ig ital line c irc uit p ac k 
    c onnec ting  8 or 17 p orts. These emulated  stations (serving  as ports) are 
    assig ned  as memb ers of a hunt g roup  that reside in a c overag e p ath. This 
    c overag e p ath is used  by every station that c overs an LAN Gateway 
    system.
    Figure 25. Typical DEFINITY LAN Gateway Installation1. System c abinet
    2. Five adjacent slots in c abinet
    3. Multi-func tion c irc uit p ac k4. Alarm c irc uit pac k
    5. DEFINITY LAN g ateway
    evdxgate RPY 090397
    1
    2
    3
    4
    5 
    						
    							DEFINITY ECS Release 8.2
    Installation for Adjuncts and Peripherals  555-233-116  Issue 1
    April 2000
    DEFINITY LAN Gateway System 
    101 Installing DEFINITY LAN Gateway in a Multicarrier Cabinet 
    7
    Installing DEFINITY LAN Gateway in
    a Multicarrier Cabinet 
    It is not nec essary to p ower d own a system b efore installing  a DEFINITY LAN 
    Gateway
    !CAUTION:
    Never loc ate a DEFINITY LAN Gateway in p ort c arrier C of a multic arrier 
    c ab inet. Never loc ate a DEFINITY LAN Gateway either in p ort slots 01 to 03 
    of an exp ansion c ontrol c ab inet or in slots 01 to 04 of a p ort c ab inet.
    !CAUTION:
    When the DEFINITY LAN Gateway assemb ly is inserted , it will automatic ally 
    p ower up  (inc lud ing  the d isk), run d iag nostic s, and b oot. Therefore, to 
    avoid a d isk c rash, never remove the assemb ly and  never p ower d own the 
    DEFINITY System without first shutting  d own the unit and  allowing  the d isk 
    to c omp letely sp in d own.
    1. If nec essary, to p rovid e five ad jac ent p ort slots in a d esirab le loc ation, 
    reloc ate and  retranslate p ort c irc uit p ac ks. See Fi g u re  2 6
    .
    The system treats a DEFINITY LAN Gateway like a TN754B/C Dig ital Line 
    c irc uit pac k c onnec ting  8 or 17 p orts. These emulated  stations (serving  as 
    p orts) are assigned  as memb ers of a hunt g roup  that resid e in a c overag e 
    p ath. This c overag e p ath is used  b y every station that c overs an LAN 
    Gateway system.
    !CAUTION:
    Do not p ower up  the DEFINITY LAN Gateway System until the 
    installation and cabling is completed. 
    						
    							DEFINITY ECS Release 8.2
    Installation for Adjuncts and Peripherals  555-233-116  Issue 1
    April 2000
    DEFINITY LAN Gateway System 
    102 Installing DEFINITY LAN Gateway in a Multicarrier Cabinet 
    7
    Figure 26. Typical DEFINITY LAN Gateway Installation1. System c abinet
    2. Five ad jac ent slots in c arrier
    3. Multi-func tion c irc uit p ac k4. Alarm c irc uit p ac k
    5. DEFINITY LAN g ateway
    cydfadr3 RPY 090397 
    						
    							DEFINITY ECS Release 8.2
    Installation for Adjuncts and Peripherals  555-233-116  Issue 1
    April 2000
    DEFINITY LAN Gateway System 
    103 Connecting the Alarm Origination Cable 
    7
    Connecting the Alarm Origination 
    Cable
    The alarm c ab le c onnec ts to the MDF and  c ross-c onnec ts to the c ustomer-
    sup p lied  alarm eq uip ment. See Fi g u re  2 7
     and Tab le 16.
    Figure 27. Connecting the Alarm Origination Cable
    1. Connec t the alarm Y-c ab le to the first c onnec tor assoc iated  with the alarm 
    c irc uit p ac k on the LAN gateway system on the rear of the system c abinet.
    2. Attac h the male Amp henol c onnec tor on a B25A c ab le to the female 
    Amp henol c onnec tor labeled ALARM
     on the alarm Y-c ab le.
    3. Connec t the op p osite end  of the B25A c able to the MDF.
    NOTE:
    Do not c onnec t the RS-232 c onnec tor on the alarm Y-c ab le. The 
    standard alarm origination circuit uses an on-board modem that is 
    internally wired  to the c onnec tor on the alarm Y-c ab le. 1. Customer-supplied alarm equipment
    2. Cross-c onnec tions to alarm eq uip ment
    3. Main d istribution frame (MDF)
    4. B25A 25-pair c able
    5. Female ALARM
     Connec tor on alarm Y-c able
    6. Unused  RS-232 c onnec tor on alarm Y-c ab le7. Alarm Y-c ab le
    8. System c ab inet 
    9. Multi-func tion c irc uit p ac k (p art of 
    LAN gateway)
    10. Alarm c irc uit p ac k (p art of LAN 
    gateway)
    cydfalm RPY 091197 
    						
    							DEFINITY ECS Release 8.2
    Installation for Adjuncts and Peripherals  555-233-116  Issue 1
    April 2000
    DEFINITY LAN Gateway System 
    104 Connecting a PC 
    7
    4. Perform the c ross-c onnec ts for the alarm orig ination c onnec tion as 
    described on the service order. Also see Ta b l e  1 6
    .
    Connecting a PC
    You need a PC to ad minister the DEFINITY LAN Gateway system. You must have 
    a loc al administration PC and  a loc al maintenanc e PC as well. 
     There are four ways to c onnec t a loc al ad ministration terminal:
    n
    Direc t c onnec tion
    n
    Mod em c onnec tion
    n
    Async hronous Data Unit (ADU) 
    n
    One 7400A d ata mod ule and one 7400B d ata mod ule (rec ommend ed ) or 
    two 7400A d ata mod ules 
    Loc al maintenanc e PCs are always c onnec ted  d irec tly.
    Directly Connecting a Terminal
    Fi g u re  2 8 shows typ ic al c onnec tions for a loc al maintenanc e PC. 
    Fi g u re  2 9
     shows typ ic al c onnec tions for a loc al ad ministration PC. 
    Table 16. Alarm Origination Pinouts (ALB Y-cable)
    Pin Number Definition
    27 Tip (white/b lue)
    1 Ring  (b lue/white)
    44 Minor RTN (return) (yellow/b rown)
    19 Minor (b rown/yellow)
    47 Major RTN (return) (violet/orang e)
    22 Major (orange/violet) 
    						
    							DEFINITY ECS Release 8.2
    Installation for Adjuncts and Peripherals  555-233-116  Issue 1
    April 2000
    DEFINITY LAN Gateway System 
    105 Connecting a PC 
    7
    Figure 28. Typical Local Maintenance PC Connections
    Figure 29. Typical Local Administration PC Connections1. Ad ministration PC
    2. RS-232 c ab le
    3. 117A isolator (DC powered  systems 
    only)
    4. Port A c onnec tor on MFB Y-c ab le
    5. Port B c onnec tor on MFB Y-c ab le6. Multifunc tion Y-c ab le (MFB)
    7. System c abinet
    8. Alarm c irc uit p ac k (p art of LAN g ateway)
    9. Multifunc tion c irc uit p ac k (p art of LAN 
    gateway)
    1. Ad ministration PC
    2. RS-232 c ab le
    3. 117A Isolator (DC-p owered  systems only)
    4. Port B c onnec tor on MFB Y-c ab le
    5. Unused  RS-232 c onnec tor on MFB Y-c ab le6. 25-p air c onnec tor on multi-func tion 
    Y- c a b le  ( M FB )
    7. System c ab inet
    8. Alarm c irc uit p ac k (p art of LAN 
    gateway)
    9. Multifunc tion c irc uit p ac k (p art of 
    LAN gateway)
    cydf001 KLC 030100
    1
    24
    5
    7
    8
    9
    3
    6
    cydf001 KLC 030100
    1
    24
    5
    7
    8
    9
    3
    6 
    						
    							DEFINITY ECS Release 8.2
    Installation for Adjuncts and Peripherals  555-233-116  Issue 1
    April 2000
    DEFINITY LAN Gateway System 
    106 Connecting a PC 
    7
    Testing a direct connection
    1. Plug  the p ower c ord  on the terminal into a wall outlet.
    2. Power on the terminal.
    3. If you are installing  a p rinter, set the p rinter op tions as d esc ribed  in the 
    p rinter manual. Then set the c orresp ond ing  op tions on the terminal to 
    matc h. 
    If the terminal is installed  c orrec tly and  if the DEFINITY LAN Gateway is in 
    the ADX
    , OAM
    , OS
     or AINIT
     state, the sc reen d isp lays the login 
    prompt.
    4. If you are not installing  a p rinter, set the terminal op tions ac c ording  to the 
    instruc tions in the terminal doc umentation.
    If the terminal is installed  c orrec tly and  if the DEFINITY LAN Gateway is in 
    the ADX
    , OAM
    , OS
     or AINIT
     state, the sc reen d isp lays the login 
    prompt.
    5. If the terminal d oes not d isp lay the login 
    p romp t, write d own the state 
    d isp layed , then see the troub leshooting  proc edures for terminal 
    c onnec tions in CallVisor ASAI/DEFINITY LAN Gateway d oc umentation.
    Connecting an administration PC via modems
    Connec t as shown in Fi g u re  3 0.
    Figure 30. Typical Administration Terminal Connections via Modems1. Printer (op tional)
    2. Administration PC
    3. RS-232 cable
    4. Modem
    5. 103A or modular wall jack
    6. Main d istrib ution frame (MDF)
    7. Pub lic  switc hed  telep hone network
    8. 117A Isolator (DC-p owered Port-A c onnec tor 
    on MFB Y-c ab le systems only)9. Port B c onnec tor on MFB Y-c ab le
    10. Port A c onnec tor on MFB Y-c ab le
    11. Multifunc tion Y-c ab le (MFB)
    12. System c abinet
    13. Alarm c irc uit p ac k (p art of LAN 
    gateway)
    14. Multifunc tion c irc uit pac k (p art of 
    LAN g ateway)
    cydfxta1 KLC 022900
    15
    1
    2
    3
    3
    4
    4
    5
    5
    66
    7
    8
    9
    10
    11
    12
    13
    14 
    						
    							DEFINITY ECS Release 8.2
    Installation for Adjuncts and Peripherals  555-233-116  Issue 1
    April 2000
    DEFINITY LAN Gateway System 
    107 Connecting a PC 
    7
    1. Attac h the c onnec tor on one end  of a mod ular c ord  to the mod em. Attac h 
    the other c onnec tor to the mod ular wall jac k (information outlet).
    2. Connec t the sec ond mod em to the wall jac k at the remote terminal site.
    3. If you are installing  a p rinter, c onnec t the p rinter to the terminal, and  set 
    the p rinter op tions as d esc rib ed  in the p rinter manual. Then set the 
    c orresp ond ing op tions on the terminal to matc h. 
    4. If you are not installing  a p rinter, set the terminal op tions ac c ording  to the 
    instruc tions in the terminal doc umentation.
    5. At the terminal, enter AT
    .
    6. If the mod em is installed  c orrec tly, it resp ond s with OK 
    (on the terminal 
    sc reen).
    7. Enter AT D T
     and the telephone number of the modem connected to Port B
     
    (listed on the Installing  the Terminals worksheet).
    If the terminal is installed  c orrec tly and  if the DEFINITY LAN Gateway is in 
    the ADX
    , OAM
    , OS
     or AINIT
     state, the sc reen d isp lays the login 
    prompt.
    8. If the terminal d oes not d isp lay the login 
    p romp t, write d own the state 
    d isp layed , then see the troub leshooting  proc edures for terminal 
    c onnec tions in CallVisor ASAI/DEFINITY LAN Gateway d oc umentation.
    Connecting an administration PC via 
    Asynchronous Data Units
    Connec t as shown in Fi g u re  3 1. 
    						
    							DEFINITY ECS Release 8.2
    Installation for Adjuncts and Peripherals  555-233-116  Issue 1
    April 2000
    DEFINITY LAN Gateway System 
    108 Connecting a PC 
    7
    Figure 31. Typical Administration PC Connections through ADUs 
    If the terminal is installed  c orrec tly and  if the DEFINITY LAN Gateway is in 
    the ADX
    , OAM
    , OS
     or AINIT
     state, the sc reen d isp lays the login 
    prompt.
    9. If the terminal d oes not d isp lay the login 
    p romp t, write d own the state 
    d isp layed , then see the troub leshooting  proc edures for terminal 
    c onnec tions in CallVisor ASAI/DEFINITY LAN Gateway d oc umentation.
    Connect the Administration PC via Data Modules
    Two d ata mod ules c an be used in this c onfig uration. The DEFINITY LAN g ateway 
    sid e of the c onfig uration requires the 7400A. A sec ond  7400A c an b e used  and  
    is c onnec ted  the same as a 7400B. Set the options as d esc rib ed  in Chap ter 4, 
    ‘‘Data Mod ules and  Async hronous Data Units’’.
    1. Make sure the EIA c onnec tor b oard  (loc ated  insid e the d ata mod ule) is set 
    to DCE (fac tory d efault). If not, unplug  the c ard  and  turn it around  to the 
    DCE setting  (see “ Mod e Selec tion”  on p ag e 5-84 for d etails).
    2. Connec t as shown in Fi g u re  3 2
    .
    3. If you are installing  a p rinter, set the p rinter op tions as d esc ribed  in the 
    p rinter manual. Then set the c orresp ond ing  op tions on the terminal to 
    matc h.  1. Administration PC
    2. 25-Pin EIA-232-D c onnec tor on Z3A1 
    ADU
    3. D8AM c rossover c ord
    4. 103A or modular wall jac k
    5. Main d istrib ution frame (MDF) 
    6. D8W c ord
    7. Power supply
    8. D7AP cord9. 400B2 adap ter
    10. Z3A2 ADU
    11. Port A c onnec tor on MFB Y-c ab le
    12. Port B c onnec tor on MFB-Y-c ab le
    13. Multifunction Y-c able (MFB)
    14. System c ab inet
    15. Multifunc tion c irc uit p ac k (p art of LAN 
    gateway)
    cydftadu RPY 091197
    1
    23
    445
    6
    7
    8
    9
    11
    12
    13
    15
    14
    10 
    						
    All Lucent Technologies manuals Comments (0)