Have a look at the manual Lucent Technologies DEFINITY Enterprise Communication Server Release 8.2 Installation For Adjuncts And Peripherals Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
DEFINITY LAN Gateway System 99 Installing DEFINITY LAN Gateway in a Single-Carrier Cabinet 7 DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 7 DEFINITY LAN Gateway System The DEFINITY LAN Gateway lets DEFINITY exc hang e messag es with LAN c ommunic ations software. The DEFINITY LAN Gateway system is used in display set mod e only, not in c ontrol link. Use it with the R8r, R8si, or R8c si. Refer to the DEFINITY Communic ations System Generic 3 Installation, Ad ministration and Maintenanc e of CallVisor ASAI over the DEFINITY LAN Gateway for c omplete installation p roc ed ures. Use the add subscribers command during administration, to prevent a no port available error. When ad ministration is c omp lete, enter reset system reboot to c lear all alarms. Installing DEFINITY LAN Gateway in a Single-Carrier Cabinet The DEFINITY LAN Gateway system installs in five ad jac ent slots, p referab ly the five rig htmost slots in a Sing le-Carrier Cab inet. See Fi g u re 2 5 . !CAUTION: Do not p ower up the DEFINITY LAN Gateway System until instruc ted to d o so. Refer to the DEFINITY Communic ations System Generic 3 Installation, Ad ministration and Maintenanc e of CallVisor ASAI over the DEFINITY LAN Gateway. It is not nec essary to p ower d own a system b efore installing a DEFINITY LAN Gateway.
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 DEFINITY LAN Gateway System 100 Installing DEFINITY LAN Gateway in a Single-Carrier Cabinet 7 !CAUTION: When the assembly is inserted , it will automatic ally p ower up (inc lud ing the d isk), run d iag nostic s, and b oot. Therefore, to avoid a d isk c rash, never remove the assemb ly and never p ower d own the DEFINITY System without first shutting down the unit and allowing the d isk to c omp letely sp in d own. NOTE: The system treats a DEFINITY LAN Gateway like a d ig ital line c irc uit p ac k c onnec ting 8 or 17 p orts. These emulated stations (serving as ports) are assig ned as memb ers of a hunt g roup that reside in a c overag e p ath. This c overag e p ath is used by every station that c overs an LAN Gateway system. Figure 25. Typical DEFINITY LAN Gateway Installation1. System c abinet 2. Five adjacent slots in c abinet 3. Multi-func tion c irc uit p ac k4. Alarm c irc uit pac k 5. DEFINITY LAN g ateway evdxgate RPY 090397 1 2 3 4 5
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 DEFINITY LAN Gateway System 101 Installing DEFINITY LAN Gateway in a Multicarrier Cabinet 7 Installing DEFINITY LAN Gateway in a Multicarrier Cabinet It is not nec essary to p ower d own a system b efore installing a DEFINITY LAN Gateway !CAUTION: Never loc ate a DEFINITY LAN Gateway in p ort c arrier C of a multic arrier c ab inet. Never loc ate a DEFINITY LAN Gateway either in p ort slots 01 to 03 of an exp ansion c ontrol c ab inet or in slots 01 to 04 of a p ort c ab inet. !CAUTION: When the DEFINITY LAN Gateway assemb ly is inserted , it will automatic ally p ower up (inc lud ing the d isk), run d iag nostic s, and b oot. Therefore, to avoid a d isk c rash, never remove the assemb ly and never p ower d own the DEFINITY System without first shutting d own the unit and allowing the d isk to c omp letely sp in d own. 1. If nec essary, to p rovid e five ad jac ent p ort slots in a d esirab le loc ation, reloc ate and retranslate p ort c irc uit p ac ks. See Fi g u re 2 6 . The system treats a DEFINITY LAN Gateway like a TN754B/C Dig ital Line c irc uit pac k c onnec ting 8 or 17 p orts. These emulated stations (serving as p orts) are assigned as memb ers of a hunt g roup that resid e in a c overag e p ath. This c overag e p ath is used b y every station that c overs an LAN Gateway system. !CAUTION: Do not p ower up the DEFINITY LAN Gateway System until the installation and cabling is completed.
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 DEFINITY LAN Gateway System 102 Installing DEFINITY LAN Gateway in a Multicarrier Cabinet 7 Figure 26. Typical DEFINITY LAN Gateway Installation1. System c abinet 2. Five ad jac ent slots in c arrier 3. Multi-func tion c irc uit p ac k4. Alarm c irc uit p ac k 5. DEFINITY LAN g ateway cydfadr3 RPY 090397
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 DEFINITY LAN Gateway System 103 Connecting the Alarm Origination Cable 7 Connecting the Alarm Origination Cable The alarm c ab le c onnec ts to the MDF and c ross-c onnec ts to the c ustomer- sup p lied alarm eq uip ment. See Fi g u re 2 7 and Tab le 16. Figure 27. Connecting the Alarm Origination Cable 1. Connec t the alarm Y-c ab le to the first c onnec tor assoc iated with the alarm c irc uit p ac k on the LAN gateway system on the rear of the system c abinet. 2. Attac h the male Amp henol c onnec tor on a B25A c ab le to the female Amp henol c onnec tor labeled ALARM on the alarm Y-c ab le. 3. Connec t the op p osite end of the B25A c able to the MDF. NOTE: Do not c onnec t the RS-232 c onnec tor on the alarm Y-c ab le. The standard alarm origination circuit uses an on-board modem that is internally wired to the c onnec tor on the alarm Y-c ab le. 1. Customer-supplied alarm equipment 2. Cross-c onnec tions to alarm eq uip ment 3. Main d istribution frame (MDF) 4. B25A 25-pair c able 5. Female ALARM Connec tor on alarm Y-c able 6. Unused RS-232 c onnec tor on alarm Y-c ab le7. Alarm Y-c ab le 8. System c ab inet 9. Multi-func tion c irc uit p ac k (p art of LAN gateway) 10. Alarm c irc uit p ac k (p art of LAN gateway) cydfalm RPY 091197
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 DEFINITY LAN Gateway System 104 Connecting a PC 7 4. Perform the c ross-c onnec ts for the alarm orig ination c onnec tion as described on the service order. Also see Ta b l e 1 6 . Connecting a PC You need a PC to ad minister the DEFINITY LAN Gateway system. You must have a loc al administration PC and a loc al maintenanc e PC as well. There are four ways to c onnec t a loc al ad ministration terminal: n Direc t c onnec tion n Mod em c onnec tion n Async hronous Data Unit (ADU) n One 7400A d ata mod ule and one 7400B d ata mod ule (rec ommend ed ) or two 7400A d ata mod ules Loc al maintenanc e PCs are always c onnec ted d irec tly. Directly Connecting a Terminal Fi g u re 2 8 shows typ ic al c onnec tions for a loc al maintenanc e PC. Fi g u re 2 9 shows typ ic al c onnec tions for a loc al ad ministration PC. Table 16. Alarm Origination Pinouts (ALB Y-cable) Pin Number Definition 27 Tip (white/b lue) 1 Ring (b lue/white) 44 Minor RTN (return) (yellow/b rown) 19 Minor (b rown/yellow) 47 Major RTN (return) (violet/orang e) 22 Major (orange/violet)
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 DEFINITY LAN Gateway System 105 Connecting a PC 7 Figure 28. Typical Local Maintenance PC Connections Figure 29. Typical Local Administration PC Connections1. Ad ministration PC 2. RS-232 c ab le 3. 117A isolator (DC powered systems only) 4. Port A c onnec tor on MFB Y-c ab le 5. Port B c onnec tor on MFB Y-c ab le6. Multifunc tion Y-c ab le (MFB) 7. System c abinet 8. Alarm c irc uit p ac k (p art of LAN g ateway) 9. Multifunc tion c irc uit p ac k (p art of LAN gateway) 1. Ad ministration PC 2. RS-232 c ab le 3. 117A Isolator (DC-p owered systems only) 4. Port B c onnec tor on MFB Y-c ab le 5. Unused RS-232 c onnec tor on MFB Y-c ab le6. 25-p air c onnec tor on multi-func tion Y- c a b le ( M FB ) 7. System c ab inet 8. Alarm c irc uit p ac k (p art of LAN gateway) 9. Multifunc tion c irc uit p ac k (p art of LAN gateway) cydf001 KLC 030100 1 24 5 7 8 9 3 6 cydf001 KLC 030100 1 24 5 7 8 9 3 6
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 DEFINITY LAN Gateway System 106 Connecting a PC 7 Testing a direct connection 1. Plug the p ower c ord on the terminal into a wall outlet. 2. Power on the terminal. 3. If you are installing a p rinter, set the p rinter op tions as d esc ribed in the p rinter manual. Then set the c orresp ond ing op tions on the terminal to matc h. If the terminal is installed c orrec tly and if the DEFINITY LAN Gateway is in the ADX , OAM , OS or AINIT state, the sc reen d isp lays the login prompt. 4. If you are not installing a p rinter, set the terminal op tions ac c ording to the instruc tions in the terminal doc umentation. If the terminal is installed c orrec tly and if the DEFINITY LAN Gateway is in the ADX , OAM , OS or AINIT state, the sc reen d isp lays the login prompt. 5. If the terminal d oes not d isp lay the login p romp t, write d own the state d isp layed , then see the troub leshooting proc edures for terminal c onnec tions in CallVisor ASAI/DEFINITY LAN Gateway d oc umentation. Connecting an administration PC via modems Connec t as shown in Fi g u re 3 0. Figure 30. Typical Administration Terminal Connections via Modems1. Printer (op tional) 2. Administration PC 3. RS-232 cable 4. Modem 5. 103A or modular wall jack 6. Main d istrib ution frame (MDF) 7. Pub lic switc hed telep hone network 8. 117A Isolator (DC-p owered Port-A c onnec tor on MFB Y-c ab le systems only)9. Port B c onnec tor on MFB Y-c ab le 10. Port A c onnec tor on MFB Y-c ab le 11. Multifunc tion Y-c ab le (MFB) 12. System c abinet 13. Alarm c irc uit p ac k (p art of LAN gateway) 14. Multifunc tion c irc uit pac k (p art of LAN g ateway) cydfxta1 KLC 022900 15 1 2 3 3 4 4 5 5 66 7 8 9 10 11 12 13 14
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 DEFINITY LAN Gateway System 107 Connecting a PC 7 1. Attac h the c onnec tor on one end of a mod ular c ord to the mod em. Attac h the other c onnec tor to the mod ular wall jac k (information outlet). 2. Connec t the sec ond mod em to the wall jac k at the remote terminal site. 3. If you are installing a p rinter, c onnec t the p rinter to the terminal, and set the p rinter op tions as d esc rib ed in the p rinter manual. Then set the c orresp ond ing op tions on the terminal to matc h. 4. If you are not installing a p rinter, set the terminal op tions ac c ording to the instruc tions in the terminal doc umentation. 5. At the terminal, enter AT . 6. If the mod em is installed c orrec tly, it resp ond s with OK (on the terminal sc reen). 7. Enter AT D T and the telephone number of the modem connected to Port B (listed on the Installing the Terminals worksheet). If the terminal is installed c orrec tly and if the DEFINITY LAN Gateway is in the ADX , OAM , OS or AINIT state, the sc reen d isp lays the login prompt. 8. If the terminal d oes not d isp lay the login p romp t, write d own the state d isp layed , then see the troub leshooting proc edures for terminal c onnec tions in CallVisor ASAI/DEFINITY LAN Gateway d oc umentation. Connecting an administration PC via Asynchronous Data Units Connec t as shown in Fi g u re 3 1.
DEFINITY ECS Release 8.2 Installation for Adjuncts and Peripherals 555-233-116 Issue 1 April 2000 DEFINITY LAN Gateway System 108 Connecting a PC 7 Figure 31. Typical Administration PC Connections through ADUs If the terminal is installed c orrec tly and if the DEFINITY LAN Gateway is in the ADX , OAM , OS or AINIT state, the sc reen d isp lays the login prompt. 9. If the terminal d oes not d isp lay the login p romp t, write d own the state d isp layed , then see the troub leshooting proc edures for terminal c onnec tions in CallVisor ASAI/DEFINITY LAN Gateway d oc umentation. Connect the Administration PC via Data Modules Two d ata mod ules c an be used in this c onfig uration. The DEFINITY LAN g ateway sid e of the c onfig uration requires the 7400A. A sec ond 7400A c an b e used and is c onnec ted the same as a 7400B. Set the options as d esc rib ed in Chap ter 4, ‘‘Data Mod ules and Async hronous Data Units’’. 1. Make sure the EIA c onnec tor b oard (loc ated insid e the d ata mod ule) is set to DCE (fac tory d efault). If not, unplug the c ard and turn it around to the DCE setting (see “ Mod e Selec tion” on p ag e 5-84 for d etails). 2. Connec t as shown in Fi g u re 3 2 . 3. If you are installing a p rinter, set the p rinter op tions as d esc ribed in the p rinter manual. Then set the c orresp ond ing op tions on the terminal to matc h. 1. Administration PC 2. 25-Pin EIA-232-D c onnec tor on Z3A1 ADU 3. D8AM c rossover c ord 4. 103A or modular wall jac k 5. Main d istrib ution frame (MDF) 6. D8W c ord 7. Power supply 8. D7AP cord9. 400B2 adap ter 10. Z3A2 ADU 11. Port A c onnec tor on MFB Y-c ab le 12. Port B c onnec tor on MFB-Y-c ab le 13. Multifunction Y-c able (MFB) 14. System c ab inet 15. Multifunc tion c irc uit p ac k (p art of LAN gateway) cydftadu RPY 091197 1 23 445 6 7 8 9 11 12 13 15 14 10