    Have a look at the manual Vodavi Starplus 2448ex Hybrid Key Telephone System Installation Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 60 Vodavi manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							~ARPLUS 2448EX Hybrid Key Telephone System 
    F. 
    G. 
    H. and Random Access Memory (RAM) for cus- 
    tomer data base programming. A lithium bat- 
    tery is included for protection of the RAM 
    memory. An RS232C connector for data base 
    printout and SMDR is included. Feature Pack- 
    age software is installed on this board at the 
    factory. One (1) CCU is required per system. 
    Central Office Interface Board (COI) 
    Provides the interface for eight central offi 
    (DTMF or Dial Pulse) loop start lines. The 
    board can be removed or inserted with KSU 
    power ON, however, the ‘Normal/Service” 
    switch should be in the ‘Service” mode before 
    removing or inserting the board into the system. 
    An in-use LED for each circuit and a switch to 
    take the board out of service are provided. 
    The CO circuits are equipped with programma- 
    ble current sensing circuitry that identifies dis- 
    tant end disconnect loop supervision, if 
    provided by the Central Office. 
    Key Station Interface Board (KSB) 
    Provides interface circuitry for eight Key Tele- 
    phones. The KSB will support any Starplus 
    Basic, Enhanced or Executive Key Telephone 
    set. The KSB board can be inserted or re- 
    moved with the KSU power ON, however, the 
    “Normal/Service” switch should be in the “Serv- 
    ice” mode before removing or inserting the 
    board into the system. An in-use LED and a 
    switch to take the card out of service are pro- 
    vided. A DSS/DLS or Phone Box can also be 
    assigned to any one of the circuits. The KSB 
    circuits are protected from mis-wiring and over- 
    current. 
    Single Line Telephone Interface Board 
    WT) 
    The Single LineTelephone Interface Board pro- 
    vides interface for eight (8) -24 vdc single line 
    (2500 type) telephones. Single Line Telephone 
    Interface Boards (SLT) and Key Station Inter- 
    face Boards (KSB’s) are inter-changeable with- 
    in the system. Both standard DTMF and 
    message waiting (9OV) DTMF single line tele- 
    phones may be used. A Single Line Board is 
    required when connecting to a Voice Mail Sys- 
    tem and In-Band integration is desired. An Ap- 
    plication Board (APB) and a Ring Generator 
    (RG) are required when installing Single Line 
    Boards. 
    480.3 OPTIONAL COMPONENTS 
    -l 
    A. Application Board (APB) 
    The Application Board provides the matrix and 
    controlling circuitry for DISA, unsupervised B. 
    C. 
    D. 
    E. 
    F. conference and one external page zone as well 
    as the circuitry for two DTMF receivers and two 
    DTMF senders to support a small number of 
    single line telephones. The APB has provisions 
    for the addition of a Single Line DTMFRS Unit 
    (SLU), used to support larger quantities of sin- 
    gle-line telephones, and an RS232C Module 
    (RSM) to add an additional RS232C port for 
    outputing SMDR information only. This port 
    cannot be used for programming iocally or rt3 
    motely via a terminal. The APB also has a 
    connection for Recorded Announcement 
    (RAN) input and its control contacts. 
    RS232C Module (RSM) 
    This RS232C Module (RSM) mounts on the 
    Application Board (APB) and provides a second 
    RS232C connector. This connector may be 
    used to output SMDR data while the standard 
    RS232C (located on the CCU) is used for sys- 
    tem printout or Remote Administration. 
    Single Line DTMF Receiver/Sender Unit 
    (SW 
    Used to expand the DTMF receivers and send- 
    ers in the System to support single line telepho- 
    nes. The module is added to the APB board 
    and contains four DTMF receivers and one 
    DTM F sender. 
    Power Failure Transfer Unit (Pt7) 
    There can be two Power Failure Transfer Units 
    installed in the Basic KSU, each providing auto- 
    matic direct cut-through connection of six 
    CO/PBX lines to six single line telephones in 
    case of commercial power failure or system 
    processor failure. The single line telephones 
    may or may not be intercom stations. For each 
    PFT installed, there is one set of Loud Bell 
    Control contacts provided. This unit can be 
    removed or inserted with power on the KSU. 
    There is a manual switch that activates the PFT 
    for testing purposes. 
    Battery Charging Unit (BC) 
    The Battery Charging Unit (BC) installs into the 
    External Power Supply Housing (EPH) and pro- 
    vides the charging circuitry for a 24V dc battery 
    package. The charging rate is 28V & at 0.5 
    ampere for the Basic KSU. 
    Single Line Ring Generator and lWIV 
    Power Supply Unit (RG) 
    Provides the 9OV ac, 20 Hz, ringing supply for 
    supporting single line telephones and OPx’s. 
    Also provides the voltage to light single line 
    telephone M/W lights when Single tine Board 
    cards are installed in the system. This unit 
    plugs into the External Power Supply Housing. 
    Issue 3, August 1991 400-3  
    						
    							Hybrid Key Telephone System STARPLUS 2446EX 
    One (1) unit is required when the system will be 
    equipped with single line telephones. 
    400.4 STATIONS 
    A. Basic Key Telephone 
    The Starplus Basic Electronic Telephone will 
    operate on both Starplus Hybrid Key Telephone 
    Systems. The Starplus Basic keyset is a fully 
    modular instrument that features On-Hook dial- 
    ing and Call Announce, Intercom, two (2) Vol- 
    ume Controls, a Personal Directory, and a 12 
    key “DTMF dial pad. 
    Note: Full speakerphone operation or Call An- 
    nounce with handsfree reply on intercom are not 
    provided with the Basic Key Telephone. 
    On the 2448EX Hybrid Key Telephone the Ba- 
    sic keyset offers compatibility by providing a 
    loop button as one of the fixed 14 feature func- 
    tion buttons. This allows the Basic keyset to 
    both place and receive transferred CO line 
    calls. 
    Note: Direct Incoming calls cannot be directed to the 
    Basic keyset on the 2448EX. 
    8. Enhanced Key Telephone 
    The Starplus Enhanced Electronic Telephone 
    (Fig 400-2) is a fully modular instrument with 14 
    fixed feature/function buttons and 16 flexibly 
    assigned buttons or 8 fixed feature/function 
    buttons. This telephone also features an inte 
    grated speakerphone, call announce with 
    handsfree intercom, two (2) Volume Controls, 
    Intercom select switch, and long life LED’s. 
    C. Executive Electronic Telephone 
    The Starplus Executive Key Telephone is a fully 
    modular instrument with 14 fixed feature/func- 
    tion and 16 flexible buttons that can be flexibly 
    assigned as either CO/PBX/Centrex lines, Sta- 
    tion DSS, or feature/function buttons for the 
    2448EX. This set also features an integrated 
    48 character LCD display, and integrated 
    speakerphone, call announce with handsfree 
    intercom, two (2) volume controls, an intercom 
    mode select switch, and long life LED%. 
    D. DSSIDLS Consoles 
    The station port used for a DSS/ DLS Console 
    can be assigned as a Direct Station Select or 
    Direct Line Select depending on customer 
    need. The bottom two rows of buttons on the 
    DS!S/DLS Console (Refer to Figure 400-2) con- 
    tain 6-8 flexible buttons (depending on MAP 
    chosen) which can be assigned by the station 
    user in the same manner and functions as the 
    flexible buttons on the keyset. E. Phone Box 
    The Phone Box (Refer to Figure 400-2) allows 
    Handsfree conversations for locations that do 
    not need dialing privileges. Phone Boxes may 
    be substituted for Key Telephones on a one-for- 
    one basis. 
    400.5 SYSTEM CAPACITY 
    The Basic KSU is housed in a wall-mountable cabi- 
    net that contains the backplane, two prewired con- 
    nectors for Power Failure Transfer units, station and 
    CO line boards, DC/DC Converter and an Applica- 
    tions board. This Basic KSU has a capacity of 24 
    CO lines and 48 Key Telephones and/ or Phone 
    Boxes. DSS/DLS’s can be installed in place of any 
    Key Telephone. Standard single line telephones 
    (2500 type) can be installed by exchanging key 
    station interface boards. Eight single line tele- 
    phones can replace eight Key Telephones for each 
    board exchanged. An ON/OFF switch is located on 
    the left side of the Basic KSU. 
    400.6 SYSTEM SPECIFICATIONS 
    System capacity, electrical specifications, environ- 
    mental specifications, and Loop limits are listed in 
    Tables 400-1, 400-2, and 400-3 and 400-4. Dialing 
    specifications are listed in Table 400-5. Dimensions 
    and weight are listed in Table 400-7. Key telephone 
    and Single tine telephone Audible Indications are 
    listed in Tables 400-9, and 400-13. Key Telephone 
    Visual Indications are listed in Tables 400-10, 400- 
    1 1, and 400-l 2. 
    400-4 Issue 3, August 1991  
    						
    							STARPLUS 2448EX 
    Hybrid Key Telephone System 
    Basic Model 
    Executive Model Enhanced Model 
    Phone Box 
    DSSID LS Console 
    Figure 4OG2 
    STARPLUS@ Station Instruments 
    Issue 3, August 1991 
    400-5  
    						
    							I- - 
    , Hybrid Key Tele(lhone System STARPLUS 2448EX 
    Table 40&l System Capacity 
    Ports: 
    COIPBWCentrex 
    Stations 
    Single Line Telephones 
    Attendants: 
    DSS/DLS Consoles: 
    24 max. 
    48max. 
    40 max. 
    Up to 3 stations can be designated as attendant(s). 
    32 max up to 3 DSS/DLS units can be programmed to function with 
    each station. (Each DSS/DLS unit reduces station capacity by 1) 
    Phone Boxes: 
    UCD Groups: 
    Groups: 
    Members: 
    RAN Announcements: 
    Calls in Queue: 
    Voice Mail Groups: 
    Groups: 
    Ports: 
    Integration Method: 
    VM Message Wait: 
    VM Disconnect Signal: 47 max (replaces key station port(s) on a 1 for 1 basis) 
    8 Groups 
    48 Members (up to 8 stations per group) 
    2 max per system 
    all 24 CO Lines may be in queue onto a UCD group(s) 
    8 Groups 
    up to 64 (8 per group) 
    In-Band Signaling 
    Yes [60] Turn on; [61] Turn off 
    CO Lines - Programmable 12 digit (DTMF) string. If no digits are pre- 
    programmed, 15 seconds of silence followed by busy tone. 
    Stations - 15 Seconds of silence followed by busy tone. 
    SMDR Ports: 
    1 port (either located on the CCU or on the optional RS-232C Module 
    (RSM) mounted on the APB Board) 
    Station Cards: 
    Key Telephone Board 
    Each Key Telephone Board supports eight (8) electronic telephones, 
    phone boxes or DSS/DLS units. 
    Single Line Board 
    SO Cards: 
    COI Each Single Line Board supports eight (8) 2500-type (DTMF) 
    telephones. 
    Each COI Board can support up to eight (8) Loop Start CO/PBX 
    Centrex lines. 
    3Ttvl F Receivers: 
    3TM F Senders: 6 max - two (2) on the APB Board. Four (4) additional provided on 
    the optional SLU board. 
    3 max - two (2) on the APB Board. One (1) additional provided on the 
    optional SLU board. 
    ‘age Zones: 
    Internal: 
    External: 
    4 Zones 
    1 Zone (Requires APB Board) 
    400-6 
    Issue 3, August 1991  
    						
    							~ARF’LUS 2448EX 
    Hybrid Key Telephone System 
    ‘1 
    , 
    -> 
    Table 400-2 Electrical Specifications 
    AC Input to Power Supply 
    Power Consumption 
    Power Supply Fuse - AC input 
    Longitudinal Balance: 
    Idle Channel Noise: 1 IN ac + IO%, 60 Hz single phase 
    720 VA 
    720 watts (maximum) 
    5Al25VAC 
    60 db from 200 Hz to 1,000 Hz 
    40 db from 1,000 Hz to 4,000 Hz 
    Less than 15 dbmco for all connections 
    Cross Talk Attenuation: 
    Single Frequency Distortion: 
    (300 Hz - 3,400 Hz) 
    Ringing Sensitivity: 
    Ringer Equivalence Number: (REN) 
    CO tine Signaling - DTMF: 
    Input Level Range: 
    Music Source (input) 
    Contact Rating 
    External Page Control 
    Loud Bell Control 
    RAN Port Control 
    External Page Port 
    output Impedance 
    Output Power 
    UL File Number: Greater than 75 dbm Station to CO and Station to 
    Station 
    Station to CO tine and Station to Station: 
    Better than 2.0% or 34 db 
    Output level -30 dbm to 0 dbm 
    16 Hz to 30 Hz at 40 VRMS minimum 
    30 Hz to 67 Hz at 50 VRMS minimum 
    0.56 
    Frequency pair at -5 dbm +I .O dbm 
    Frequency tolerance fl .5% 
    +I 0 db maximum 
    2mWmax.atOdBm 
    2K ohms input impedance 
    1 .OA, 24V dc 
    1 .OA, 24V dc 
    1 .OA, 24V dc 
    600 ohms @ 0 dBm 
    1 mW Maximum 
    El 09461 
    Table 400-3 Environmental Specifications 
    , 
    I 
    Operating Temperature 
    Recommended Operating Temperature 
    Storage Temperature 
    Relative Humidity 
    Heat Dissipation (BTU’s) 32°to1040F 
    70’ to 76’ F 
    -40’ to 140’ F 
    5% to 90% noncondensing 
    1350 BTU’s Maximum 
    Issue 3, August 1991 400-7  
    						
    							Hybrid Key Telephone System STARPLUS 2448EX 
    Table 400-4 Loop Limits 
    Electronic Telephone: 
    (including Single Line Telephone, Phone Box, and 
    DSS/DLS) 500 feet of 26 AWG Cable 
    1000 feet of 24 AWG Cable 
    1500 feet of 22 AWG Cable 
    Table 400-5 Dialing Specifications 
    DTMF Dialing 
    Frequency Deviation 
    Rise Time 
    Duration of DTMF Signal 
    Interdigit Time 
    PULSE Dialing 
    Pulse Dialing Rate 
    Pulse Break/Make Duration 
    Dialing Memory 
    System Speed Dialing 
    Station Speed Dialing 
    Save Number F&dial 
    Last Number Redial 
    CO Type +I% 
    3 msec. 
    100 msec. minimum 
    100 msec. minimum 
    10 or 20 pps. 
    60140 or 66l33 
    80 numbers (24 digits) 
    20 numbers (24 digits) 
    1 number (32 digits) 
    1 number (32 digits) 
    Loop Stan 
    Table 400-6 FCC Registration Numbers 
    For Systems configured as a key system (button 
    appearance) use: 
    For Systems configured as a hybrid system (dial 
    access codes) use: DLP82V-17567-KF-E 
    DLP82V17568-MF-E 
    400-8 Issue 3, August 1991  
    						
    							STARPLUS 2448EX 
    Hybrid Key Telephone System 
    Table 400-7 Dimensions and Weight 
    BASIC KEY SERVICE UNIT 
    Height 16” 
    Width 23” 
    Depth 13” 
    Weight 
    66 Ibs. (unloaded) 
    EXTERNAL POWER SUPPLY HOUSING 
    Height 12” 
    Width 12” 
    Depth 13” 
    Weight 36 Ibs. 
    POWER SUPPLY 
    Height 4.75” 
    W& 4” 
    Depth 
    9” 
    Weight 5 tbs. DSS/DLS CONSOLE 
    Height 
    Width &” 
    Depth 9:i 25” 
    Weight 2 tbs. 
    PHONE BOX 
    Height I .75” 
    Width 5.s 
    Depth 4” 
    Weight 1 lb. 
    KEY TELEPHONE 
    Height 3.5” 
    Width 8” 
    9.125”  Depth 
    Weight 3 lbs. 
    Table 400-8 Miscellaneous Specifications 
    Memory: 
    Random Access Memory (RAM) 
    Programmable Read-Only-Memory (PROM) 
    Telephone Transmitter: 
    Talk Paths: 
    CO/PBX/Centrex paths: 
    Intercom Paths: 
    Music Channels: 
    Account Codes: 
    Number of digits per code: 
    Number of Account Codes: 
    Speed Dialing Capacity: 
    System Speed 
    Station Speed 96K expandable to 128K 
    384 expandable to 512K 
    Electret mic compatible. 
    24 CO/PBXCentrex talk paths (non-blocking) 
    12 talk paths (only 10 available for SLTs) 
    1 channel provides music for m&con-hold and 
    background music 
    up to 12 unverified digits 
    unlimited 
    1360 total bins in system 
    80 bins per system 
    1280 bins per system  
    						
    							Hybrid Key Telephone System STARPLUS 2448EX 
    Table 400-9 Key Telephone Audible Signals 
    TYPE OF SIGNAL 
    . 
    )
    						
    							Table 400-l 1 CO Line Button Visual lpdicators 
    -- 
    ~ARPLUS 2448Ex Hybrid Key Telephone System . 
    TYPE OF SIGNAL INDICATOR FLASH RATES 
    Incoming CO Ring 
    Transferred CO Ring 
    RaGill 
    Queued tine 
    Exclusive Hold 
    System Hold 
    I-Hold (only when hold preference is system) 
    In Use 30 ipm flash 
    120 ipm flash 
    480 ipm flutter 
    460 ipm flutter 
    120 ipm flash 
    60 ipm wink 
    30 ipm double flash 
    Steady 
    Table 40042 Function Button Visual Indicators 
    TYPE OF SIGNAL INDICATOR FLASH RATES 
    Call Forward (active) 
    Message Waiting (active) 
    Camp-on (active) 
    Call Back (active-initiator) 
    CO Line Queue (active) 
    Do Not Disturb (DND active) 
    Mute (microphone off, handset xmit off) 
    ON/OFF (speakerphone on/on-hook dialing 
    Conference (active) 
    Hold (Camp-on) 
    Hold (all intercom channells busy) 
    Speed (momentarily ON until bin address dialed) 
    Personalized Messages 
    Intercom Call (Hold Button) 
    Pool 
    Transfer 
    flash 
    Pickup 30 ipm flash 
    15 ipm flash 
    60 ipm flash 
    120 ipm flash 
    Steady 
    60 ipm flash 
    Steady 
    Steady 
    Steady 
    120 ipm flash 
    Steady 
    Steady 
    15 ipm flash 
    15 ipm flash 
    Same as CO Line 
    buttons 
    Same as CO Line buttons 
    Steady until transfer complete 
    Steady during dialing 
    Momentary ON 
    Issue 3, August 1991 400-l 1  
    						
    							Hybrid Key Telephone System WARPLUS 2448u( 
    Table 40&13 Single Line Telephone Audible Signals 
    TYPE OF SIGNAL FREQUENCY SIGNAL DURATION 
    incoming CO tine 
    Intercom Tone Ringing 
    Transferred CO Line 
    CO Line Recall 
    CO Queue Call Back 20 Hz, 50-90V AC 20s orv4.os off 
    20 Hz, 50-9OV AC 1 .Os 017/0.2s off/O.8s on/4.Os off 
    20 Hz, 50-9OV AC 2.0s onlrl.os off 
    20 Hz, SO-9OV AC 2.0s on/4.os off 
    20 Hz, SO-90V AC 2.0s orv4.os off 
    . 
    ce Tona 
    Intercom Ringback 
    Call Announce 
    Busy Tone 
    Error Tone 
    Intercom Dial Tone 
    DND Tone 1 .Os oti3.Os off; repeated 
    0.2s on/O.2s off (3 bursts) 
    0.5s onIO.5~ off: repeated 
    0.5s orVO.5s off; repeated 
    Continuous 
    0.2s on/O.2s off, repeat 3x’s, pause, 0.5s; 
    repeated 
    Paging Timeout 
    Call FWD Warning Tone 
    Camp-on Tone 
    Conference Warning Tone 
    Confirmation Tone 
    DND Warning Tone 0.5s orVO.5~ off; repeated 
    0.2s on/O.2s off (six times) 
    0.2s burst (1 time) 
    1 set burst (1 time) 
    1.4 set burst (1 time) 
    0.2s 011/0.2s off (6 bursts) 
    Table 40&14 Ring GeMMessage Wait (RG) Specifications 
    Ring Generator Input: 
    Ring Generator Output: 
    Message Waiting Output: 
    Ring Generator Capacity: 
    Simultaneous Ringing (same cadence): 
    Ring Cycles: 
    Maximum Number of Simultaneous SLTs ring 
    ing:(cycled) 24 Vdc 
    20 Hz, 50-90 VAC 
    90 V dc, unregulated 
    5 Single Line Telephones 
    5 
    25 
    . 
    400-l 2 Issue 3, August 1991  
    						