Have a look at the manual Vodavi Starplus 2448ex Hybrid Key Telephone System Installation Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 60 Vodavi manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
STARPLUS@ 2446EX Hybrid Key Telephone System APPENDIX B STARPLUS 2448EX PART NUMBERS Appendix B-l Starplus 2448W Component LSst . . PescnDtw Pati No, 2448EX Basic Key Service Unit (KSU) Direct Station/Line Selector (DSs/DLS) 2448EX Central Processor Board (CCU) Central Office Interface Board (COI) Key Station Interface Board (KSB) Single Line Telephone Interface Board (SIB) Single Line DTMFRS Unit (SLU) Applications Board (APB) Power Failure Transfer Unit (PFT) RS232C Module (RSM) 2448EX Desc, Install, and Cper Manual 2448EX Station Users Guide 2448EX Attendant Users Guide 2448EX SLT Users Guide 2448EX DSSJDLS Numbered Designation Tabs External Power Supply Housing (EPH) Power Supply Unit (PS) Battery Charging Card (BC) Single tine Ring Generator (RG) DC/DC Converter (DC/DC) Bypass Board for External Power Housing Basic Key Telephone Enhanced Key Telephone Executive Key Telephone Phone Box (Ash) SP Wall Mount Kit SP Replacement Handset SP Button Caps SP Blank Designation Tabs SP Replacement 12 ft Handset Cord SP Directory Window for Basic Key SP Replacement 25 ft Handset Cord Where XX= SP2400-00 SP241 O-XX SP2430-00 SP2431-00 SP2432-00 SP2433-00 SP2434-00 SP2435-00 SP2436-00 SP2437-00 SP2450-00 SP2452-00 SP2453-00 SP2454-00 SP2462-00 SP2470-00 SP2471-00 SP2472-00 SP2473-00 SP2474-00 SP2475-00 SP61610-xx SP61612-00 SP61614XX SP61616-44 SP61640-xx SP61660-XX SP61662-00 SP61664-00 SP61666-xx SP61668-00 P14108-XX OO= Black &Ash 54= Gray 60= Burgundy , Issue 3, August 1991 Appendix B-1
sTARPLlt!Sbb 2446EX Hybrid Key Telephone System APPENDIX C AEC The Messengerm 212 Plus Description AEC’s The Messenger 212 Plus, Dual-Line An- nouncer can be used to provide the Recorded Announcement feature of the 2446EX and the 96EX Uniform Call Distribution feature (UCD) that provides unanswered incoming CO Calls or calls in queue with a recorded message while waiting for an available UCD station. The 2446EX and 96EX systems provide a program- mable option that allows the use of unused CO line positions, SLT ports as the specified RAN output port(s) or the APL RAN port (96EX only). Each UCD group may be programmed to connect a waiting caller to either the first or second RAN port for the initial message, then select the other RAN --I port, if connected, for the second and subsequent messages. Installation The Messenger 212 Plus can be connected to the 2446EXorthe96EXinthefollowingconfigurations. - One or Two SLT ports. - One or Two CO line ports. - The APL RAN port (96EX only) and if needed one CO line port. The connection of each type of port requires dif- ferent installation practices and will be described For connection of the Messenger to either the APL RAN Port (96EX only) or to a CO line Port the separately. Messenger 212 Plus must be configured as follows. SLT Ports To install the 212 Plus using one or two SLT ports the following equipment is required and must be installed for proper operation. - An SLT Board (SP2433-00) or SIB board (SP4933-90) with available ports. - One APB Board (SP243500) or APL Board (SP4935-00). - One RG/MW power supply (SP2473-00) - One or two modular jacks (4 or 6 pin). When connecting the Messenger 212 Plus using one or two SLT ports the following options on the 212 Plus unit must be set; 1. Set the switches on the back of the unit as follows; Sl - off s2 - off s3 - off s4 - off 2. The internal jumper plug of the Messenger 212 Plus should be in its defautl line type setting of CO/PBX. This will match the SLT port(s) of the system and provide ring trip for the start of the message. NOTE: When the jumper plug of the Mes- senger 212 Plus is set to CO/PBX for the line type then both lines of the Messenger must be connected to SLT ports of the system. 3. Connect the Voice Tip and Voice Ring from the “J” connector of the SLT port being used to a modular jack. Using the line cords provided plug in to the modular jack and one of the tine jacks in the back of the Mes- senger 212 Plus unit. (See figure 1) APL RAN and CO Line Ports 1. Set the switches on the back of the Messenger 212 Plus unit as follows; Sl -off s2 - off s3 - off S4 - on . Issue 3, August 1991 Appendlx C-l
STARPLUS@%@EX Hybrid Key Telephone System SIB AEC The Messenger 212 Plus Figure C-1 SLT to AEC Connections 2. The internal jumper plug of the Messenger 212 Plus unit should be set to the first alternative setting for a 600 ohm transformer coupled audio output. Check the Messenger 212 Plus Owners Manual for procedures on changing the internal jumper plug. position on the back of the Messenger 212 Plus unit. If an ACT 6 position to 6 position cord is not available use the wiring diagram in figure 2 as a guide to connect the Messenger 212 Plus unit to NOTE: Using the 600 ohm setting of the Messenger 212 Plus both lines of the Mes- senger must be connected to any combina- tion of the APL RAN output port (96EX only) or one or two CO line port(s). When installing the Messenger 212 Plus unit onto the 96EX System, both the APL RAN output port and a CO tine port can be used simultaneously. However connection of the Messenger to these ports is different. For this reason each type of installation will be described separately. APL RAN Port (96EX only) When the Messenger 212 Plus unit is installed using the APL RAN port the following equipment will be required. - An APL Board (SP4035-00) - An ACT 8 position to 6 position modular line cord. (98ACT462) 1. To connect the Messenger 212 Plus to the APL RAN jack plug the 6 position end of the ACT modular line cord into the APL RAN Port (APL MOD 3 jack) then plug the 8 position end of the line cord into the line 1 or line 2 the APL RAN port. CO Line as a RAN Port To Install the Messenger 212 Plus using a CO Line port as the RAN output port the following equipment is necessary for a proper installation. - Unused CO line ports on a COI, COB or ~ COA Board. (SP2431-00 or SP4031-00 or SP4031-10) - Power Fail Transfer unit (SP2436-00) wifh Loud Bell Control for each CO port to be used. - 24 volt DC power supply to provide a fil- tered talk path (less than 1 amp is re- quired). - Two (2) 300 ohm l/4 watt resistors for each circuit. - One or two 8 conductor modular jacks and 8 conductor line cords. Appendix C-2 Issue 3, August 1991
STARPLUS@ 2448EX Hybtid Key Telephone System APL Tin? STOP 1 START 2 D VOICE 3 VOICE 4 START 5 I B STOP 6 212 Plus %I%+ STOP STOP VOICE VOICE GROUND START Figure C-2 ACT 8 Cond. to 6 Cond. RAN Line Cord To install the Messenger 212 Plus using a CO circuit as the interface connect as described below. -. (see figure 3) 1. Conned the 300 ohm resistor in series with the - (negative) lead of the 24 volt DC power supply and the CO tip on the “P” connector. 2. Next connect the second 300 ohm resistor in series to the + (positive) lead of the power supply and the 8 position modular connector pin 5 (Tii / green). 3. Then wire the ring lead from the “P” connector of the CO port being used to pin 4 of the 8 pin modular jack (Ring / red). 4. Connect both of the LSC contact leads of the Power Fail Transfer unit to the START and GROUND leads of the 8 pin modular jack (pins 7 and 8). Connection of the Messenger 212 Plus to the sys- tem is now complete. Proceed with applying power and recording your message(s) as described in the Messenger 212 Plus Owners manual. ,- . Programming It will be necessary to update the data base of the 2448EX or 96EX system to include the RAN op tions. Depending on the application the following program codes will need to be updated. a Universal Call Distriiution (FLASH 19) lt is necessary to specify which RAN table(s) will be used for each UCD group assigned. This is done by pressing button 12 while in UCD programming. b UCD Timers (FLASH 33) The Ring timer (button 1) determines how long an incoming CO call will ring into the UCD group before being answered and presented to the first message. The Message Interval Timer (MlT)(button 2) determines the duration of time the caller will be in queue and on hold between messages The OVeRflow timer (button 3) determines the total time, starting from when the call was answered, a caller will be kept in queue before being routed to the overflow station. c Announcement Tables, (FLASH 34) This deter- mines the type, index (port) number and length for the two available Recorded announcements (RAW When defining SLT port(s) or CO tine port(s) as the RAN output port it is most important to set the TIME parameter (length of the mes- sage) in the Announcement Table so that it is approximately one second longer than the ac- tual message. Issue 3, August 1991 Appendix C-3
STARPLUS@ 2448EX Hybrid Key Telephone System d When a CO line has been used it will be neces- sary to program an L5C contact to that par- ticular line. This is accomplished in Loud Bell Control assignments (FLASH 16). Assign the CO port to be used for the RAN operation to one of the LBC contacts. Refer to the Starplus 2446EX or 96EX Description, Installation and Operation manual for further in- structions on how to enter the program mode and additional information on the above listed program options. Also reference The Messenger Owner’s Manual for recording, battery operation and troubleshooting information. ‘p’ Blodr (66 Type) ) LBC I ---.--- I TerminaJs II - A Figure C-3 COB to AEC Connections Appendix C-4 Issue 3, August 1991
TM kxl \/0i=1/4\/1 TECHNICAL FACT NOTICE TFN-024 hiarch 6,1992 CORRECTION TO STARPLUS 2448EX MANUAL, ISSUE 3, AUGUST 1991 The following pages of the Starplus 2446EX Manual, Issue 3,August 1991, have been changed and should be replaced: Table of Contents, Page(s): iv, Issue Control Page. Section300 Page(s):30013,300-7,300-11,300-17 Section 310 Page(s):3105 Section 400 Page(s): 400-1, 400-4, 400-9. Section 500 Page(s):500-1, 500-7,500-21. Section 600 Page(s): 600-1, 600-7. Section 620 Page(s): 620-1, 620-3. Section 630 Page(s): 630-1, 630-7, 630-9, 630-11,630-12. Appendix A Page(s): A-9 Page 1 of 1 Vodavi Communications Systems 8300 E. Raintree Drive Sconsdale,Az 85260 (802)443-6000