Home > Vodavi > Communications System > Vodavi Starplus 2448ex Hybrid Key Telephone System Installation Manual

Vodavi Starplus 2448ex Hybrid Key Telephone System Installation Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Vodavi Starplus 2448ex Hybrid Key Telephone System Installation Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 60 Vodavi manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							STARPLUS@ 2446EX 
    Hybrid Key Telephone System 
    APPENDIX B 
    STARPLUS 2448EX PART NUMBERS 
    Appendix B-l Starplus 2448W Component LSst 
    . . 
    PescnDtw 
    Pati No, 
    2448EX Basic Key Service Unit (KSU) 
    Direct Station/Line Selector (DSs/DLS) 
    2448EX Central Processor Board (CCU) 
    Central Office Interface Board (COI) 
    Key Station Interface Board (KSB) 
    Single Line Telephone Interface Board (SIB) 
    Single Line DTMFRS Unit (SLU) 
    Applications Board (APB) 
    Power 
    Failure Transfer Unit (PFT) 
    RS232C Module (RSM) 
    2448EX Desc, Install, and Cper Manual 
    2448EX Station Users Guide 
    2448EX Attendant Users Guide 
    2448EX SLT Users Guide 
    2448EX DSSJDLS Numbered Designation Tabs 
    External Power Supply Housing (EPH) 
    Power Supply Unit (PS) 
    Battery Charging Card (BC) 
    Single tine Ring Generator (RG) 
    DC/DC Converter (DC/DC) 
    Bypass Board for External Power Housing 
    Basic Key Telephone 
    Enhanced Key Telephone 
    Executive Key Telephone 
    Phone Box (Ash) 
    SP Wall Mount Kit 
    SP Replacement Handset 
    SP Button Caps 
    SP Blank Designation Tabs 
    SP Replacement 12 ft Handset Cord 
    SP Directory Window for Basic Key 
    SP Replacement 25 ft Handset Cord 
    Where XX= SP2400-00 
    SP241 O-XX 
    SP2430-00 
    SP2431-00 
    SP2432-00 
    SP2433-00 
    SP2434-00 
    SP2435-00 
    SP2436-00 
    SP2437-00 
    SP2450-00 
    SP2452-00 
    SP2453-00 
    SP2454-00 
    SP2462-00 
    SP2470-00 
    SP2471-00 
    SP2472-00 
    SP2473-00 
    SP2474-00 
    SP2475-00 
    SP61610-xx 
    SP61612-00 
    SP61614XX 
    SP61616-44 
    SP61640-xx 
    SP61660-XX 
    SP61662-00 
    SP61664-00 
    SP61666-xx 
    SP61668-00 
    P14108-XX 
    OO= Black 
    &Ash 
    54= Gray 
    60= Burgundy , 
    Issue 3, August 1991 Appendix B-1  
    						
    							sTARPLlt!Sbb 2446EX Hybrid Key Telephone System 
    APPENDIX C 
    AEC The Messengerm 212 Plus 
    Description 
    AEC’s The Messenger 212 Plus, Dual-Line An- 
    nouncer can be used to provide the Recorded 
    Announcement feature of the 2446EX and the 
    96EX Uniform Call Distribution feature (UCD) that 
    provides unanswered incoming CO Calls or calls in 
    queue with a recorded message while waiting for 
    an available UCD station. 
    The 2446EX and 96EX systems provide a program- 
    mable option that allows the use of unused CO line 
    positions, SLT ports as the specified RAN output 
    port(s) or the APL RAN port (96EX only). Each 
    UCD group may be programmed to connect a 
    waiting caller to either the first or second RAN port 
    for the initial message, then select the other RAN 
    --I port, if connected, for the second and subsequent 
    messages. 
    Installation 
    The Messenger 212 Plus can be connected to the 
    2446EXorthe96EXinthefollowingconfigurations. 
    - One or Two SLT ports. 
    - One or Two CO line ports. 
    - The APL RAN port (96EX only) and if 
    needed one CO line port. 
    The connection of each type of port requires dif- 
    ferent installation practices and will be described For connection of the Messenger to either the APL 
    RAN Port (96EX only) or to a CO line Port the 
    separately. 
    Messenger 212 Plus must be configured as follows. 
    SLT Ports 
    To install the 212 Plus using one or two SLT ports 
    the following equipment is required and must be 
    installed for proper operation. 
    - An SLT Board (SP2433-00) or SIB board 
    (SP4933-90) with available ports. 
    - One APB Board (SP243500) or APL 
    Board (SP4935-00). 
    - One RG/MW power supply (SP2473-00) 
    - One or two modular jacks (4 or 6 pin). When connecting the Messenger 212 Plus using 
    one or two SLT ports the following options on the 
    212 Plus unit must be set; 
    1. Set the switches on the back of the unit as 
    follows; 
    Sl - off 
    s2 - off 
    s3 - off 
    s4 - off 
    2. The internal jumper plug of the Messenger 
    212 Plus should be in its defautl line type 
    setting of CO/PBX. This will match the SLT 
    port(s) of the system and provide ring trip for 
    the start of the message. 
    NOTE: When the jumper plug of the Mes- 
    senger 212 Plus is set to CO/PBX for the 
    line type then both lines of the Messenger 
    must be connected to SLT ports of the 
    system. 
    3. Connect the Voice Tip and Voice Ring from 
    the “J” connector of the SLT port being used 
    to a modular jack. Using the line cords 
    provided plug in to the modular jack and one 
    of the tine jacks in the back of the Mes- 
    senger 212 Plus unit. (See figure 1) 
    APL RAN and CO Line Ports 
    1. Set the switches on the back of the Messenger 
    212 Plus unit as follows; 
    Sl -off 
    s2 - off 
    s3 - off 
    S4 - on 
    . 
    Issue 3, August 1991 Appendlx C-l  
    						
    							STARPLUS@%@EX Hybrid Key Telephone System 
    SIB AEC 
    The Messenger 
    212 Plus 
    Figure C-1 SLT to AEC Connections 
    2. The internal jumper plug of the Messenger 212 
    Plus unit should be set to the first alternative 
    setting for a 600 ohm transformer coupled 
    audio output. Check the Messenger 212 Plus 
    Owners Manual for procedures on changing 
    the internal jumper plug. position on the back of the Messenger 212 
    Plus unit. 
    If an ACT 6 position to 6 position cord is not 
    available use the wiring diagram in figure 2 as a 
    guide to connect the Messenger 212 Plus unit to 
    NOTE: Using the 600 ohm setting of the 
    Messenger 212 Plus both lines of the Mes- 
    senger must be connected to any combina- 
    tion of the APL RAN output port (96EX 
    only) or one or two CO line port(s). 
    When installing the Messenger 212 Plus unit onto 
    the 96EX System, both the APL RAN output port 
    and a CO tine port can be used simultaneously. 
    However connection of the Messenger to these 
    ports is different. For this reason each type of 
    installation will be described separately. 
    APL RAN Port (96EX only) 
    When the Messenger 212 Plus unit is installed 
    using the APL RAN port the following equipment 
    will be required. 
    - An APL Board (SP4035-00) 
    - An ACT 8 position to 6 position modular 
    line cord. (98ACT462) 
    1. To connect the Messenger 212 Plus to the 
    APL RAN jack plug the 6 position end of the 
    ACT modular line cord into the APL RAN Port 
    (APL MOD 3 jack) then plug the 8 position 
    end of the line cord into the line 1 or line 2 the APL RAN port. 
    CO Line as a RAN Port 
    To Install the Messenger 212 Plus using a CO Line 
    port as the RAN output port the following equipment 
    is necessary for a proper installation. 
    - Unused CO line ports on a COI, COB or ~ 
    COA Board. (SP2431-00 or SP4031-00 or 
    SP4031-10) 
    - Power Fail Transfer unit (SP2436-00) wifh 
    Loud Bell Control for each CO port to be 
    used. 
    - 24 volt DC power supply to provide a fil- 
    tered talk path (less than 1 amp is re- 
    quired). 
    - Two (2) 300 ohm l/4 watt resistors for 
    each circuit. 
    - One or two 8 conductor modular jacks 
    and 8 conductor line cords. 
    Appendix C-2 
    Issue 3, August 1991  
    						
    							STARPLUS@ 2448EX Hybtid Key Telephone System 
    APL 
    Tin? 
    STOP 1 
    START 2 D 
    VOICE 3 
    VOICE 4 
    START 5 
    I B 
    STOP 6 212 Plus 
    %I%+ 
    STOP 
    STOP 
    VOICE 
    VOICE 
    GROUND 
    START 
    Figure C-2 ACT 8 Cond. to 6 Cond. RAN Line Cord 
    To install the Messenger 212 Plus using a CO 
    circuit as the interface connect as described below. 
    -. (see figure 3) 
    1. Conned the 300 ohm resistor in series with 
    the - (negative) lead of the 24 volt DC power 
    supply and the CO tip on the “P” connector. 
    2. Next connect the second 300 ohm resistor in 
    series to the + (positive) lead of the power 
    supply and the 8 position modular connector 
    pin 5 (Tii / green). 
    3. Then wire the ring lead from the “P” connector 
    of the CO port being used to pin 4 of the 8 pin 
    modular jack (Ring / red). 
    4. Connect both of the LSC contact leads of the 
    Power Fail Transfer unit to the START and 
    GROUND leads of the 8 pin modular jack 
    (pins 7 and 8). 
    Connection 
    of the Messenger 212 Plus to the sys- 
    tem is now complete. Proceed with applying power 
    and recording your message(s) 
    as described in the 
    Messenger 212 Plus Owners manual. 
    ,- . Programming It will be necessary to update the data base of the 
    2448EX or 96EX system to include the RAN op 
    tions. Depending on the application the following 
    program codes will need to be updated. a Universal Call Distriiution (FLASH 19) lt is 
    necessary to specify which RAN table(s) will be 
    used for each UCD group assigned. This is 
    done by pressing button 12 while in UCD 
    programming. 
    b UCD Timers (FLASH 33) The Ring timer (button 
    1) determines how long an incoming CO call will 
    ring into the UCD group before being answered 
    and presented to the first message. 
    The Message Interval Timer (MlT)(button 2) 
    determines the duration of time the caller will 
    be in queue and on hold between messages 
    The OVeRflow timer (button 3) determines the 
    total time, starting from when the call was 
    answered, a caller will be kept in queue before 
    being routed to the overflow station. 
    c Announcement Tables, (FLASH 34) This deter- 
    mines the type, index (port) number and length 
    for the two available Recorded announcements 
    (RAW 
    When defining SLT port(s) or CO tine port(s) 
    as the RAN output port it is most important to 
    set the TIME parameter (length of the mes- 
    sage) in the Announcement Table so that it is 
    approximately one second longer than the ac- 
    tual message. 
    Issue 3, August 1991 Appendix C-3  
    						
    							STARPLUS@ 2448EX Hybrid Key Telephone System 
    d When a CO line has been used it will be neces- 
    sary to program an L5C contact to that par- 
    ticular line. This is accomplished in Loud Bell 
    Control assignments (FLASH 16). Assign the 
    CO port to be used for the RAN operation to 
    one of the LBC contacts. 
    Refer to the Starplus 2446EX or 96EX Description, 
    Installation and Operation manual for further in- 
    structions on how to enter the program mode and 
    additional information on the above listed program 
    options. Also reference The Messenger Owner’s 
    Manual for recording, battery operation and 
    troubleshooting information. 
    ‘p’ Blodr (66 Type) 
    ) LBC 
    I ---.--- I TerminaJs 
    II - A 
    Figure C-3 COB to AEC Connections 
    Appendix C-4 
    Issue 3, August 1991  
    						
    							TM 
    kxl 
    \/0i=1/4\/1 TECHNICAL FACT NOTICE 
    TFN-024 
    hiarch 6,1992 
    CORRECTION TO STARPLUS 2448EX MANUAL, ISSUE 3, AUGUST 1991 
    The following pages of the Starplus 2446EX Manual, Issue 3,August 1991, have been changed and should be 
    replaced: 
    Table of Contents, Page(s): iv, Issue Control Page. 
    Section300 Page(s):30013,300-7,300-11,300-17 
    Section 310 Page(s):3105 
    Section 400 Page(s): 400-1, 400-4, 400-9. 
    Section 500 Page(s):500-1, 500-7,500-21. 
    Section 600 Page(s): 600-1, 600-7. 
    Section 620 Page(s): 620-1, 620-3. 
    Section 630 Page(s): 630-1, 630-7, 630-9, 630-11,630-12. 
    Appendix A Page(s): A-9 
    Page 1 of 1 
    Vodavi Communications Systems 8300 E. Raintree Drive Sconsdale,Az 85260 (802)443-6000  
    						
    All Vodavi manuals Comments (0)