Have a look at the manual Vodavi Starplus 2448ex Hybrid Key Telephone System Installation Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 60 Vodavi manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Hybrid Key Telephone System STARPLUS@%WEX PROGRAM CODE BEN FEATURE DEFAULT VALUE (after initializina) FLASH 21 1 SMDR NO (disabled) FLASH 26 FLASH 27 FLASH 26 FLASH 29 FLASH 30 FLASH 31 FLASH 32 FLASH 33 1 2 1 3 FLASH 34 FLASH 35 Dedicated Attendant Intercom Path Background Music Settincr Date and Time ISLT Hookswitch Timer ~ SLT Hookswitch Bounce Timer Yes Yes M/D:1 2 HR 10 (1 sec.) 010 msec. Voice Mail Outpulsing Tables l-7 Voice Mail Disconnect Table 6 Disconnect Table is empty by 660-2 Issue 3, August 1991
sThAPLUS??4l8EX Hybrid Key Telephone System --. Initialize Data Base Parameters (Cont’d) 660.2 INITIALIZE CO LINE AlTRIBUTES Pfugramming Steps If the system is in the programming mode, continue using the program codes. lf starting to program here, enter&e programming mode. (Refer to Sec. 600.3). If CO Line Attributes need to be initialized: 1. Press FLASH and dial [71]. The following mes- sage will be shown on the display phone: Description The CO Line parameters may be initialized setting all data fields to their original, defautt values. Th8 following data fields are returned to their default value upon initializing the CO tine parameters: 2 To initialize the CO tine Attributes, press the HOLD button. Confirmation tone will be heard. ? PROGRAM CODE
Hybrid Key Telephone System Initialize Data Base Parameters (Cont’d) 660.3 INITIALRE STATION AlTRIBUTES Programming Steps If the system is in the programming mode, continue using the program codes. If starting to program here, enter the programming mode. (Refer to Sec. 600.3). If Station Attributes need to be initialized: 1. Press flASH and dial [72]. The following mes- sage will be shown on the display phone: Description The Station parameters may be initialized setting all data fields to their original, default values. The fol- lowing data fields are returned to their default value upon initializing the Station parameters: , 2. To initialize the Station Attributes, press the HOLD button. Confirmation tone will be heard. PROGRAMCODE FLASH 50, Paoe A FLEX FEATURE DEFAULT VALUE BUTTON (after initializing) A/l Pasing Access Allowed (enabled) A/2 Do Not Disturb Allowed (enabled) A/3 Svstem Speed Access Allowed (enabled) A14 Queuing Access Allowed (disabled) At5 Preferred Line Answer Dis-allowed (disabled) AI6 SLT Conference Allowed (enabled) At7 Call Forward Allowed (enabled) A/8 Forced LCR Dis-allowed (disabled) Al9 LCR Class of Service Not required(disabled) All Key Station defauft to Station ID 0 (keyset) B/l Station ID AU Single Line Telephones default to ID 4 (SLT w/o MSG Wait) 8/2 Station Class of Service All Stations assigned COS 1 B/3 Speakerphone Option All Stations assigned option 1 B/4 Group Pick-Up Assionment(s) All Stations assigned into Group 1 B/5 Paging Zone(s) Assignment(s) All Stations assigned into Zone 1 B/6 Preset Forward Destination None assinned B/7 CO Line Group Access All Stations assigned access to I Grnm I FLASH 50, Page B 1 B/8 1 flex Button Assignment 1 See default button assignment 1 666-4 issue 3, August 1991
Hybrid Key Telephone System FLEX 1 FLEX 2 FLEX 5 FLEX 6 FLEX 13 FLEX 14 FLEX 15 FLEX 16 u SPD 3t THIS BUlTON IS MAPPED AS A LOOP BUlTON ON THE BASIC KEYSET Figure 660-l 2448EX Default Button Mapping Issue 3, August 1991 660-6
Hybrid Key Telephone System Initialize Data Base Parameters (Cont’d) 660.4 INITIALQE EXCEPTION TABLES Programming Steps If the system is in the programming mode, continue using the program codes. If starting to program here, enter the programming mode. (Refer to Sec. 600.3). If Exception Tables need to be initialized: I. Press FLASH and dial [73]. The following mes- sage will be shown on the display phone: Description The Exception Table parameters including the Al- tow/Deny Tables and the Special Tables may be initialized setting all tables to their original, default values. The following Tables are cleared returning to their default value upon initializing the Exception Tables parameters; 2. To initialiie the Exception Tables, press the HOLD button. Confirmation tone will be heard. PROGRAM CODE FLEX I PI ITTfihl I FEATURE FLASH 60 1 Allow Table A 2 Deny Table A 3 Allow Table B 4 Deny Table B I 5 1 Special Table 1 I 6 1 Special Table 2 7 Special Table 3 8 Special Table 4 (Home Area Code) Table Cleared (no entries) Table Cleared (no entrfes) Table Cleared (no entries) Table Cleared (no entries allowed, no area code specified) Table Cleared (no entries allowed, no area code specified) Table Cleared (no entries allowed, no area code specified) Table Cleared (no entries allowed) 6696 Issue 3, August 1991
lnitiallre Data Base Parameters (Cont’d) 660.5 lNlllAUZE SYSTEM SPEED Programming Steps Description If the system is in the programming mode, continue using the program codes. If starting to program here, enter the programming mode. (Refer to Sec. 600.3). If System Speed bins need to be initialiied: 1. Press FLASH and dial [74]. The following mes- sage will be shown on the display phone: Numbers entered into the System Speed dial Table may be Waked clearing all bins to their original, default value (empty). All bins 20 through 99 are cleared returning to their default value (empty) upon initial&g the Speed Dial Table. 2. To initialize the System Speed bins, press the HOLD button. Confirmation tone will be heard. 7 Issue 3, August 1991 660-7
. Hybrid Key Telephone System %ARPLUS%448~ Initialize Data Base Parameters (Cont’d) 660.6 INITlALlZE LCR TABLES Programming Steps Description If the system is in the programming mode, continue The LCR Tables may be initialized setting all tables using the program codes. If starting to program here, to their original, default values. The following tables enter the programming mode. (Refer to Sec. 600.3). will be reset to their original default value after initiali- If LCR Tables need to be initialized: zation of the LCR tables: 1. Press RASH and dial [7q. The following mes- 0 sage will be shown on the display phone: 0 2. To initialize the LCR Tables, press the HOLD button. Confirmation tone will be heard. Exception Table s-Digit table 6-Diiit Table Route List Table Daily Start Time Table Weekly Schedule Insert/Delete Table PROGRAM CODE FLEX FEATURE DEFAULT VALUE ( Q) L BUTTON after initializin FLASH 61 1 3-Digit Routing Table Default 2 6-Digit Routing Table None 3 Exception Code Table 4 Route List Table 5 Insert/Delete Table 6 Daily Start Time Table 7 Weekly Schedule Table 660-a issue 3, August 1991
STARPLUS@ 2446EX Hybrid Key Telephone System SECTION 670 SYSTEM DATA BASE PRINTOUTS 670.1 PRINT ENTIRE SYSTEM DATA BASE Programming Steps If the system is in the programming mode, continue using program codes. If starting to program here enter the programming mode first (refer to paragraph 600.3). If a complete printout of the entire data base is desired: 1. Press FLASH and dial [80]. The following mes- sage will be shown on the display of a display phone: 2. To print the entire data base, press the HOLD button. The display will update to indicate what portion of the data base is being printed. When the system has finished sending the entire data base to the printer, confirmation tone will be heard. Description With a printer connected to the RS232C port, of the CCU, the currently stored customer data base can be printed or tploaded” into a file. This command allows the entire data base to be “dumped” as a permanent record which can serve as a hard copy of the data base. The system Baud rate must match that of the printer or receiving device. Refer to section 610.20 for instructions on viewing or changing the baud rate in the 2448EX system. Printing the entire data base takes a while to print. The data base is printed in the following order: - All System Parameters - All CO Line programming (CO tines 01-24) - All Station attributes (Stations 10-n) - Toll Tables (allow, deny and special tables) - System Speed Dial Numbers (bins 20-99) - LCRTables Refer to the following Figures for examples of the data base printouts. Also refer to the following para- graphs for instructions on printing only portions of the data base. Issue 3, August 1991 670-l
A Hybrid Key Telephone System wARPLUS@ 2448EX System Data Base Printouts (Cont’d) 670.2 SYSTEM PARAMETERS Programming Steps If the system is in the programming mode, continue using program codes. If starting to program here enter the programming mode first (refer to paragraph 600.3). If a printout of all System Parameters is desired: 1. Press FLASH and dial [81]. The following mes- sage will be shown on the display of a display phone: 2. To print the system parameter data base, press the HOLD button. The display will update. When the system has finished sending the informa- tion to the printer confirmation tone will be heard. Description With a printer connected to the RS282C port, of the CCU, the currently stored customer data base can be printed or “uploaded” into a file. This command allows the System Parameters data base to be “dumped” as a permanent record which can serve as a hard copy. The system Baud rate must match that of the printer or receiving device. Refer to section 610.20 for instructions on viewing or changing the baud rate in the 2448EX system. When printing the System Parameters the following data is printed; l All System Timers l All System wide options (i.e. external night ringing, Hold preference etc...) l Attendant programming l Other system assignments (i.e. Loud bell, ExecutiveSecretary, SMDR etc...) l UCD group and associated programming l Voice Mail Group and associated program- ming Refer to the following Rgure for an example of the system parameters data base print out. 670-2 Issue 3, August 1991
t 1 ~AAPLUS@ 2448EX Hybrid Key Telephone System I HFT HFD DAC HPR PRI ENR 10 10 100 SYS Y N 1 90R INT BGM LCR PWT Y Y Y N Y i WIENDANT STATIONS 10 ## Pi I ;OUD BELL ASSIGNMENTS ### C## ?BX DIALING CODES I# C# II# #I ## ZECUTIWUSECRETARY PAIRINGS . = ! = z: f i I = : = ii d;: ;;ALT OVRANO STN# I91 192 193 194 ‘95 E E a 8 I 8 8 UN R 96 97 CD TIMERS ING MIT OVER 60 60 60 Data Base Printout Desctiption 7A MONITOR Eng. Ver. l.lf DATE: 07/24/91 TIME: 14:10:43 ENTER PASSWORD: adm-, ENTER PROGRAM NO adm.81 PRINT SYS PARAM PRESS HOLD admz SYSTEM PARAMETERS Eng. Ver. 1.lf SHR EHR XFR PFT PT CPT 60 180 45 10 2 180 CFT MWT PTO COT ART ICM SRT 10 0 15 3 1 20 20 SHR= System Hold Recall Timer H-R= Exclusive Hold Recall Timer XFR= Transfer Recall Timer PFT= Preset Forward Timer PT= Pause Timer CPT= Call Park Timer CFN= Call Forward No-Answer Timer CFT= Conference Timer MWT= Message Wait Reminder Tone PTO= Page Timeout Timer COT= CO Ring Detect Timer ART= Attendant Recall Timer ICM= Phone Box Timer SRT= Single Line Receiver Timer HFT= Hook flash Timer HFD= Hookswiich Bounce Timer DAC- DISA Access Code HPR= Hold Preference ENR= External Night Ringing AOR= Attendant Override INT= Dedicated Attendant Intercom BGM= Background Music LCR= LCR Enable/Disable PWT= Page Warning Tone UCD= Uniform Call Distribution ALT= UCD Alternate UCD Group OVR= UCD Overflow Station ANO- Announcement Tables Index STN#= UCD Station Numbers RING= UCD Ring Timer MIT= UCD Message Interval Timer OVER= UCD Overflow Timer Figure 67&l DB Printout of System Parameters