Have a look at the manual Vodavi Starplus 2448ex Hybrid Key Telephone System Installation Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 60 Vodavi manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Hybrid Key Telephone System %ARPLUSw 2446EX Data Base Printout Description ANNOUNCEMENTTABLE TYPE INDEX TIME i PPI ### t:: SMDR TYPE PRNT BAUD ACCT N LD 80 4800 N DIAL PULSE RATIO SPEED 6040 1OPPS vM ALT LEv Rr sTNc 690 # 691 P P 692 P # 693 t # 694 # P 695 # # 696 t # 697 # # VOICE MAIL OUT TABLE IDX PREFIX SUFFIX 0 VOICE MAIL CO DISCONNECT SIGNAL exiting admin... WI- Voice Mail Group ALT= Alternate Voice Mail Groups LEV= tiave” Outpulsing Table Index RET= yletrieve” Outpulsing Table Index STN#= VM Station numbers Figure 67&l DB Printout of System Parameters (Con’t) 670-4 Issue 3, August 1991
System Data Ease Printouts (Cont’d) 670.3 CO LINE AlTRIBUTES Programming Steps Description If the system is in the programming mode, continue using program codes. If starting to program here enter the programming mode first (referto paragraph 600.3). If a printout of the CO Line Attributes is desired: 1. Press FLASH and dial [82]. The following mes- sage wilt be shown on the display of a display phone: With a printer connected to the RS232C port, of the CCU, the currently stored customer data base can be printed or “uploaded” into a file. This command allows either a range of CO Lines or the entire CO . Line data base to be “dumped” as a permanent record which can serve as a hard copy of the CO Line attribute data base. The system Baud rate must match that of the printer or receiving device. Refer to section 610.20 for instructions on viewing or changing the baud rate in the 2448EX system. When printing the CO Line attributes the following data is printed: 2. Enter a four (4) digit number for the range of lines a printout is desired. To print a single CO Line enterthat line numbertwice (i.e. 0101). To print out data for all CO Lines enter [0124]. the following display will be shown on the display phone; When the system has finished sending the re- quested information to the printer, confirmation tone will be heard. l All CO Line parameters l CO Line ringing assignments Refer to the following Figure for an example of the CO Line attribute data base print out. Issue 3, August 1991 670-5
Hybrid Key Telephone System STARPLUS@ 2448EX Data Base Printout Description 7A MONITOR Eng. Ver. l.lf DATE: 07/24/91 TIME: 14:13:38 ENTER PASSWORD: adm>, ENTER PROGRAM NO adrc-82 PRINT CO LINES ENTER RANGE PRESS HOLD adm adroOl CO LINE ATTRIBUTES co 1 -- SIGNAL TYPE UNA SUPV DTMF CO Y N DISA FLTM GRP COS UCD N 10 1 1 ### co 2 -- SIGNAL TYPE UNA SUPV DTMF CO Y N DISA FLIM GRP COS UCD N 10 1 1 ### co 3 -- SIGNAL TYPE UNA SUPV DTMF CO Y N DISA FLlM GRP COS UCD N 10 1 1 ### . . . . . . . . . . . . ..,... CO 24 -- SIGNAL TYPE UNA SUPV DTMF CO Y N DISA FLIM GRP COS UCD N 10 1 1 ##ii admm exiting admin... SIGNAL- DTtvlF/Dial Pulse TYPE= CO/PBX UNA= Universal Night Answer SUPV= Loop Supervision DISA= Direct Inward System Access FLTM= Flash Timer GRP= CO Line Group COS= CO Line Class of Service irCD=UCD Ringing to UCD Group Figure 670-2 DB Printout of CO Line Attributes 6704 Issue 3e Auaust 1991
sTARPLUS@ 2448EX Hybrid Key Telephone System System Data Base Printouts (Cont’d) 670.4 STATION ATTRIBUTES Proqramming Steps If the system is in the programming mode, continue using program codes. If starting to program here enter the programming mode first (refer to paragraph 600.3). If a printout of the Station Attributes is desired: 1. Press FLASH and dial 163). The following mes- sage will be shown on the display of a display phone: 2. Enter a four (4) digit number for the range of stations a printout is desired. To print a single stations data enter that station extension num- ber twice (i.e. 1010). To print out data for all stations enter [I 057. the following display will be shown on the display phone: When the system has finished sending the re- quested information to the printer, confirmation tone will be heard. Description With a printer connected to the RS232C port, of the CCU, the currently stored customer data base can be printed or “uploaded” into a file. This command allows either a range of station data or all stations data information to be “dumped” as a permanent record which can serve as a hard copy of the station attribute data base. The system Baud rate must match that of the printer or receiving device. Refer to section 610.20 for instructions on viewing or changing the baud rate in the 2446EX system. When printing the Station attributes the following data is printed; l AJI current station parameters l Current Flex Button assignments Refer to the following Figure for an example of a Station attribute data base print out. Issue 3, August 1991 670-7
Hybrid Key Telephone System sTARPLUS@ 2448EX Data Base Printout Description 7A MONITOR Eng. Ver. l.lf DATE: 07/24/91 TIME: 14:14:53 ENTER PASSWORD: admz-, ENTER PROGRAM NO adm>83 PRINT STATIONS ENTER RANGE PRESS HOLD admz-1057 STATION ATTRIBUTES STA 10 PAGE DND SPD QUE PLA CSLT YYYYN N LCOS LCR FWD SID AID COS SPK 0 N Y 0 1 0 PICKUP 1 PAGE 1 PREFWD CO ACCESS 1 SLT RING BUTTONS OlDlO 02Dll 03D12 04D13 05D14 06D15 07D16 08D17 0901B 1002B 1103B 1204B 1305B 1406B 15PLl 16LP . . . . . . . . . . . . . . . . . . STA 57 - PAGE DND SPD QUE PLA CSLT YYYYN N LCOS LCR FWD SID AID COS SPK 0 N Y 0 1 0 PICKUP 1 PAGE 1 PREFWD CO ACCESS 1 SLT RING BUTTONS OOPL7 adm>m exiting admin... PAGE= Paging Access DND= Do Not Disturb SPD= System Speed Dial Access QUE= Line Queue Access PLA= Preferred Line Answer CSLT=SLT Add-On Conference LCOS- LCR Class of Service LCR= Forced LCR MID= Station Call Forward Access SID= Station ID AID= Associated ID (DSS/DLS Console) COS=Class of Service SPK= Speakerphone Option PICKUP= Pickup Groups PAGE= Paging Groups PREFWD= Preset Forward Assignment CO ACCESS= CO Line Access BUTTONS= Refer to Table 630-I Figure 670-3 DB Printout of Station Attributes 670-8 Issue 3. Auaust 1991
sTARPLUS@ 2448EX Hybrid Key Telephone System System Data Base Printouts (Cont’d) 670.5 EXCEPTION TABLES Programming Steps If the system is in the programming mode, continue using program codes. If starting to program here enter the programming mode first (refer to paragraph 600.3). If a printout of the Exception tables are desired: 1. Press FLASH and dial [&I]. The following mes- sage will be shown on the display of a display phone: 2. Press a flexible button to correspond to the exception table a print out is desired. Then press HOLD. When the system has finished sending the re- quested information to the printer, confirmation tone will be heard. Description With a printer connected to the RS232C port, of the CCU, the currently stored customer data base can be printed or “uploaded” into a file. This command allows each exception table to be printed individually to serve as a permanent record which can be saved as a hard copy of the exception table data base. The system Saud rate must match that of the printer or receiving device. Refer to section 610.20 for instructions on viewing or changing the baud rate in the 2446EX system. When printing information from the exception tables the flex buttons are mapped as follows: Refer to the following Figure for an example of the Exception Tables data base print out. Issue 3, August 1991 670-9
Hybrid Key Telephone System sTARPLUS@ 2448EX 7A MONITOR Eng. Ver. l.lf DATE: 07/24/91 TIME: 14:17:09 ENTER PASSWORD: a&, ENTER PROGRAM NO adm>84 PRINT EX TABLES ENTERBUTIUNNUMBER a-q PRINT ALLOW TABLE A PRESS HOLD adm EXCEPTION TAELES adm>r PRINT DENY TABLE B PRESS HOLD adm EXCEPTION TABLES Deny Table B ii E- :34 08 09 05 10 Allow Table A -- 01 11 adm-w PRINT DENY TABLE A PRESS HOLD adm EXCEPTION TABLES Deny Table A it it- 03 08 04 05 E adm>e PRINT ALLOW TABLE B PRESS HOLD adm EXCEPTION TABLES Allow Table B ~- 01 11 07 08 Yo PRINT SPECIAL TABLE 1 PRESS HOLD adm EXCEPTION TABLES SPECIAL TABLE 1 AREA CODE ALLOWED OFFICE CODES adrns PRINT SPECIAL TABLE 2 PRESS HOLD adm EXCEPTION TABLES SPECIAL TABLE 2 AREA CODE ALLOWED OFFICE CODES admd PRINT SPECIAL TABLE 3 PRESS HOLD adm EXCEPTION TABLES SPECIAL TABLE 3 AREA CODE ALLOWED OFFICE CODES admf PRINT SPECIAL TABLE 4 PRESS HOLD adm EXCEPTION TABLES SPECIAL TABLE 4 HOME AREA CODE ALLOWED OFFICE CODES admxn exiting admin... Figure 670-4 DB Printout of Exception Tables 670-l 0 Issue 3, August 1991
Hybrid Key Telephone System sTARPLUS@ 2448EX 7A MONITOR Eng. Ver. l.lf DATE: 07/24/91 TIME: 14:19:02 ENTER PASSWORD: ab, ENTER PROGRAM NO adm>85 PRINT SYS SPEED NO ENTER RANGE PRESS HOLD adn-02083 SYSTEM SPEED NUMBERS 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 %21 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 adm>m exiting admin... Figure 670-5 DB Printout of System Speed Numbers 670-l 2 Issue 3, August 1991