    Have a look at the manual Panasonic Kx-Td308 Digital Super Hybrid System Installation Maintenence Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 399
    							220Installation of the Main Unit2.2.1 Unpacking
    Unpack the box and check the items below:
    Main Unitone
    AC Cordone
    Templateone
    Screws (Wall Mounting)three
    Screw (Extension Connector)one
    Pager Connectorone
    Music Source Connectorone
    2.2.2Location of Interfaces
    Outside Line Modular Jack
    Ground Terminal
    Doorphone Connector
    External Music Jack
    Serial Interface
    Connector (RS-232C)
    2-4Installation 
    						
    							2.2.3 Wall Mounting
    This set is designed for wall mounting only. The wall where the
    main unit is to be mounted must be able to support the weight of
    the main unit. If screws other than the ones supplied are used, use
    screws with the same diameter as the ones enclosed.Mounting on Wooden WallMounting on Concrete or Mortar
    Wall1. Place the template (included) on the wall
    1. Place the template (included) on the wall
    to mark the screw positions.
    to mark the screw positions.
    2. Install the screws (included) into the wall.
    3. Hook the main unit on the screw heads.2. Drill holes and drive the anchor plugs
    (user-supplied) with a hammer, flush to
    the wall.
    3. Install the screws (included) into the
    anchor plugs.
    To the wall surface
    Anchor Plue
    I4. Hook the main unit on the screw heads.
    Installation
    2-5 
    						
    							2.2.4 Opening Front Cover1. Loosen the screw.2. Slide the front cover toward the right while pressing the 
    m mark.
    NoteThe screw cannot be removed from the system.2-6Installation 
    						
    							2.2.5 Frame Ground Connection2.2.5Frame Ground Connection
    IMPORTANT!!!
    Connect the frame of the main unit to ground.
    1. Loosen the screw.
    2. Insert the grounding wire.
    3. Tighten the screw.
    4. Connect the grounding wire to ground.
    To ground
    In most of North America, the ground provided by the “Third wire ground” at the commercial
    power outlet will be satisfactory.However, in a small percentage of cases this ground may be
    installed incorrectly. Therefore, the following test procedure should be performed.
    Test Procedure
    i.
    2.
    3.
    4.
    5.
    I
    Obtain a suitable voltmeter and set it for a possible reading of up to 250 VAC.
    Connect the meter probes between the two main AC voltage points on the wall outlet. The
    reading obtained should be 108-132 VAC.
    Move one of the meter probes to the 3rd prong terminal (GND).
    Either the same reading or a reading of 0 volt should be obtained.
    If a reading of 0 volt at one terminal and a reading of 
    108- 132 VAC at the other terminal is
    not obtained, the outlet is not properly grounded.
    This condition should be corrected by a qualified electrician (per article 250 of the National
    Electrical Code).
    If a reading of 0 volt at one terminal and a reading of 
    108- 132 VAC at the other terminal is
    obtained, then set the. meter to the 
    “OHMS/RXl” scale, place one probe at the GND Terminal
    and the other probe at the terminal which gave a reading of 0 volt.
    A reading of less than 1 ohm should be obtained.
    If the reading is not obtained the outlet is not adequately grounded, see a qualified electrician.
    Installation
    2-7 
    						
    							23lConnection2.3.1System Connection Diagram
    &=L,2(Lightning Protectors)
    3 Outside Linesto outside lines 1 through 3
    P
    DoorphoneDoor
    KX-T30865Opener
    AmplifierSpeakerPrinter or
    II8 Extensions
    (One ‘T(t$o pair) A
    KX-T7020KX-T7220
    /7
    r, (two
    Kx-no50
    Cordless Phone
    Telephone Answering
    Machine with Facsimile
    3
    Voice Processing SystemKx-no55
    KX-T7130KX-no30(two pair)
    KX-T7235
    KX-T7240
    KX-T7040
    Notel It is recommended that extension of jack 1 is a
    display proprietary telephone.
    l Parallel connection of telephones is possible. Refer
    to Section 2.3.4 “Paralleled Telephone Connection”.
    2-8Installation 
    						
    							2.3.2 Outside Line ConnectionConnection1.Insert the modular plugs of the telephone line cords (6-
    conductor wiring) into the modular jacks on the system.
    2. Connect the line cord to the outside line jack and the terminal
    board or the Central Office jack.
    $T1I-- -.l-u-Outside Line I
    To Terminal Board or
    Modular Jacks from
    the Central Office
    Installation2-9 
    						
    							2.3.2 Outside Line ConnectionInstalling Lightning Protectors
    A lightning protector is a device to be installed on an outside line to
    prevent a dangerous surge from entering the building and damaging
    equipment.
    A dangerous surge can occur if a telephone line comes in contact
    with a power line. Trouble due to lightning surges has been
    showing a steady increase with the development of electronic
    equipment.
    In many countries, there are regulations requiring the installation of
    a lightning protector. A lightning strike to a telephone cable which
    is 10 m (33 feet) above ground can be as high as 
    200,ooO volts.
    This system should be installed with lightning protectors. In
    addition, grounding (connection to earth ground) is very important
    for the protection of the system.Recommended lightning protectors
    l TELESPIKE BLOK MODEL TSB (TRIPPE MPG. CO.)
    l SPIKE BLOK MODEL SK6-0 (TRIPPE MPG. CO.)
    l Super MAXTM (PANAMAX)
    l MPl (ITW LINK)
    Installation
    co
    coco
    _ Lightning
    FrotectorsSystem
    Terminal
    BoardEXTN
    Ground
    - Terminal
    Frame Ground
    G&d
    co:Central Office (Outside line)
    EXTN: Extension lineTEL: Telephone
    2-10Installation 
    						
    							2.3.2 Outside Line ConnectionInstallation of an Earth Rodco
    Lightning
    Protectors
    Grounding Wire
    I
    System
    (Underground)
    Rod1) Installation location of the earth rod.............Neartheprotector
    2) Check obstructions........................................None
    3)Composition of the earth rodMetal ........................
    4)Depth of the earth rod...................................More than50 cm
    (20 inches)
    5) Size of the grounding wire............................Thicknessis more
    than 16 AWG
    Notel The above figures are recommendations only.
    l Tbe length of earth rod and the required depth depend on tbe
    composition of tbe soil.Installation
    2-11 
    						
    							2.3.3 Extension ConnectionTelephone WiringExtension jacks 1 through 4 are for all kinds of telephones.
    Extension jacks 5 through 8 are only for digital proprietary
    telephones. To make extension jacks 5 through 8 usable for all
    kinds of telephones, a 4-SLT Extension Expansion Card 
    (KX-TD30870) must be installed.
    The maximum length of the extension line cord (twisted cable)
    which connects the system and the extension is as follows:
    Diameter of the lineMax. length
    Standard Telephone
    22AWG1798m (5900 feet)
    24AWG
    1128m (3700 feet)
    26AWG698m (2290 feet)
    Proprietary Telephone 22AWG
    360m (1180 feet)
    24AWG229m (750 feet)
    26AWG
    140m (460 feet)2 or 4-conductor wiring is required for each extension as listed
    below. There are four pins for possible connection: “T”, 
    “I?‘, “Dl”
    and “D2”.
    T: TipDl: Low
    R: RingD2: High
    TelephoneWiring
    Standard telephones1 pair wire (T, R)
    Digital proprietary telephone
    (e.g., KX-T7230, KX-T7235)
    1 pair wire (Di, D2) or
    2 pair wire (DI, D2, T, R) for extra Device Port
    Analog proprietary telephone
    (e.g.,KX-T7030,KX-l7130)2 pair wire (Di, D2, T, R)
    Notel If a KX-TD30870 is installed
    Note the jack numbers for the facsimile and standard telephone which
    have Caller ID service.
    l If a telephone or answering machine with an A-Al relay is connected to
    the system, set the
    A-Al relay switch of the telephone or answering machine to the OFF
    position.
    2-12Installation 
    						
    							2.3.3 Extension ConnectionConnection1. Insert the 50-pin connector to the Extension Jack as shown.
    2. Connect the wire cords to the appropriate connector pins and the
    terminal equipment. Refer to the Telephone Wiring and Pin
    Number Chart (page 2- 14).
    I50-pin(Amphenol 57JE
    series or the equivalent)
    To the terminal equipment
    Notel To fix the Amphenol 57JE type (screw-attach type 50-pin connector) to
    the Extension Jack. To attach the 
    Amphenol 57JE type (plug) to the
    connector, drive the accessory screw into the upper part. Fasten the
    Amphenol cable with the cord faster.3, Accessory screw
    YY
    II u-Amphenol 57JE typeInstallation
    2-13 
    						