Have a look at the manual Panasonic Kx-Td308 Digital Super Hybrid System Installation Maintenence Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
220Installation of the Main Unit2.2.1 Unpacking Unpack the box and check the items below: Main Unitone AC Cordone Templateone Screws (Wall Mounting)three Screw (Extension Connector)one Pager Connectorone Music Source Connectorone 2.2.2Location of Interfaces Outside Line Modular Jack Ground Terminal Doorphone Connector External Music Jack Serial Interface Connector (RS-232C) 2-4Installation
2.2.3 Wall Mounting This set is designed for wall mounting only. The wall where the main unit is to be mounted must be able to support the weight of the main unit. If screws other than the ones supplied are used, use screws with the same diameter as the ones enclosed.Mounting on Wooden WallMounting on Concrete or Mortar Wall1. Place the template (included) on the wall 1. Place the template (included) on the wall to mark the screw positions. to mark the screw positions. 2. Install the screws (included) into the wall. 3. Hook the main unit on the screw heads.2. Drill holes and drive the anchor plugs (user-supplied) with a hammer, flush to the wall. 3. Install the screws (included) into the anchor plugs. To the wall surface Anchor Plue I4. Hook the main unit on the screw heads. Installation 2-5
2.2.4 Opening Front Cover1. Loosen the screw.2. Slide the front cover toward the right while pressing the m mark. NoteThe screw cannot be removed from the system.2-6Installation
2.2.5 Frame Ground Connection2.2.5Frame Ground Connection IMPORTANT!!! Connect the frame of the main unit to ground. 1. Loosen the screw. 2. Insert the grounding wire. 3. Tighten the screw. 4. Connect the grounding wire to ground. To ground In most of North America, the ground provided by the “Third wire ground” at the commercial power outlet will be satisfactory.However, in a small percentage of cases this ground may be installed incorrectly. Therefore, the following test procedure should be performed. Test Procedure i. 2. 3. 4. 5. I Obtain a suitable voltmeter and set it for a possible reading of up to 250 VAC. Connect the meter probes between the two main AC voltage points on the wall outlet. The reading obtained should be 108-132 VAC. Move one of the meter probes to the 3rd prong terminal (GND). Either the same reading or a reading of 0 volt should be obtained. If a reading of 0 volt at one terminal and a reading of 108- 132 VAC at the other terminal is not obtained, the outlet is not properly grounded. This condition should be corrected by a qualified electrician (per article 250 of the National Electrical Code). If a reading of 0 volt at one terminal and a reading of 108- 132 VAC at the other terminal is obtained, then set the. meter to the “OHMS/RXl” scale, place one probe at the GND Terminal and the other probe at the terminal which gave a reading of 0 volt. A reading of less than 1 ohm should be obtained. If the reading is not obtained the outlet is not adequately grounded, see a qualified electrician. Installation 2-7
23lConnection2.3.1System Connection Diagram &=L,2(Lightning Protectors) 3 Outside Linesto outside lines 1 through 3 P DoorphoneDoor KX-T30865Opener AmplifierSpeakerPrinter or II8 Extensions (One ‘T(t$o pair) A KX-T7020KX-T7220 /7 r, (two Kx-no50 Cordless Phone Telephone Answering Machine with Facsimile 3 Voice Processing SystemKx-no55 KX-T7130KX-no30(two pair) KX-T7235 KX-T7240 KX-T7040 Notel It is recommended that extension of jack 1 is a display proprietary telephone. l Parallel connection of telephones is possible. Refer to Section 2.3.4 “Paralleled Telephone Connection”. 2-8Installation
2.3.2 Outside Line ConnectionConnection1.Insert the modular plugs of the telephone line cords (6- conductor wiring) into the modular jacks on the system. 2. Connect the line cord to the outside line jack and the terminal board or the Central Office jack. $T1I-- -.l-u-Outside Line I To Terminal Board or Modular Jacks from the Central Office Installation2-9
2.3.2 Outside Line ConnectionInstalling Lightning Protectors A lightning protector is a device to be installed on an outside line to prevent a dangerous surge from entering the building and damaging equipment. A dangerous surge can occur if a telephone line comes in contact with a power line. Trouble due to lightning surges has been showing a steady increase with the development of electronic equipment. In many countries, there are regulations requiring the installation of a lightning protector. A lightning strike to a telephone cable which is 10 m (33 feet) above ground can be as high as 200,ooO volts. This system should be installed with lightning protectors. In addition, grounding (connection to earth ground) is very important for the protection of the system.Recommended lightning protectors l TELESPIKE BLOK MODEL TSB (TRIPPE MPG. CO.) l SPIKE BLOK MODEL SK6-0 (TRIPPE MPG. CO.) l Super MAXTM (PANAMAX) l MPl (ITW LINK) Installation co coco _ Lightning FrotectorsSystem Terminal BoardEXTN Ground - Terminal Frame Ground G&d co:Central Office (Outside line) EXTN: Extension lineTEL: Telephone 2-10Installation
2.3.2 Outside Line ConnectionInstallation of an Earth Rodco Lightning Protectors Grounding Wire I System (Underground) Rod1) Installation location of the earth rod.............Neartheprotector 2) Check obstructions........................................None 3)Composition of the earth rodMetal ........................ 4)Depth of the earth rod...................................More than50 cm (20 inches) 5) Size of the grounding wire............................Thicknessis more than 16 AWG Notel The above figures are recommendations only. l Tbe length of earth rod and the required depth depend on tbe composition of tbe soil.Installation 2-11
2.3.3 Extension ConnectionTelephone WiringExtension jacks 1 through 4 are for all kinds of telephones. Extension jacks 5 through 8 are only for digital proprietary telephones. To make extension jacks 5 through 8 usable for all kinds of telephones, a 4-SLT Extension Expansion Card (KX-TD30870) must be installed. The maximum length of the extension line cord (twisted cable) which connects the system and the extension is as follows: Diameter of the lineMax. length Standard Telephone 22AWG1798m (5900 feet) 24AWG 1128m (3700 feet) 26AWG698m (2290 feet) Proprietary Telephone 22AWG 360m (1180 feet) 24AWG229m (750 feet) 26AWG 140m (460 feet)2 or 4-conductor wiring is required for each extension as listed below. There are four pins for possible connection: “T”, “I?‘, “Dl” and “D2”. T: TipDl: Low R: RingD2: High TelephoneWiring Standard telephones1 pair wire (T, R) Digital proprietary telephone (e.g., KX-T7230, KX-T7235) 1 pair wire (Di, D2) or 2 pair wire (DI, D2, T, R) for extra Device Port Analog proprietary telephone (e.g.,KX-T7030,KX-l7130)2 pair wire (Di, D2, T, R) Notel If a KX-TD30870 is installed Note the jack numbers for the facsimile and standard telephone which have Caller ID service. l If a telephone or answering machine with an A-Al relay is connected to the system, set the A-Al relay switch of the telephone or answering machine to the OFF position. 2-12Installation
2.3.3 Extension ConnectionConnection1. Insert the 50-pin connector to the Extension Jack as shown. 2. Connect the wire cords to the appropriate connector pins and the terminal equipment. Refer to the Telephone Wiring and Pin Number Chart (page 2- 14). I50-pin(Amphenol 57JE series or the equivalent) To the terminal equipment Notel To fix the Amphenol 57JE type (screw-attach type 50-pin connector) to the Extension Jack. To attach the Amphenol 57JE type (plug) to the connector, drive the accessory screw into the upper part. Fasten the Amphenol cable with the cord faster.3, Accessory screw YY II u-Amphenol 57JE typeInstallation 2-13