Have a look at the manual Panasonic Kx-Td308 Digital Super Hybrid System Installation Maintenence Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
3FeaturesS Station Programming DescriptionAllows the proprietary telephone (PT) user to customize the extension to their needs. The following programming items are available: For the PT (RX-T7220; RX-T7230; RX-T7235; RX-T7250; KX- T7 130; RX-T7020; RX-T7030; RX-T7050) Call Waiting Tone Type Assignment Flexible CO Button Assignment Full One-Touch Dialing Assignment Intercom Alert Assignment Preferred Line Assignment - Incoming / Outgoing Station Programming Data Default Set For digital PT (RX-T7220; RX-T7230; RX-T7235; RX-T7250) only, Handset / Headset Selection Live Call Screening Mode Set Ringing Tone Selection for CO Buttons For display PT (RX-T7230; RX-T7235; RX-T7 130; RX-T7030) only, Bilingual Display Selection Initial Display Selection Self-Extension Number Confirmation For digital large display PT (RX-T7235) only, Station Speed Dialing Number / Name Assignment For the operator and manager’s extension PT only, Call Log Lock Control, Incoming Live Call Screening Password Control Remote Station Lock Control Detailed information and programming instructions are described in the User Manual, Station Programming. ConditionsDuring Station Programming, the PT is considered to be in busy status. Programming References StationProgramming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . User Manual Operator / ManagerServiceFeatures . . . . . . . . . . . . . . . . . . . . . . . . . . . . UserManual Call Log Lock Control, Incoming Live Call Screening Password Control Remote Station Lock Control Feature ReferencesNone Operation References Not applicable. Features3-141
S3Features Station Programming Data Default Set DescriptionAllows the proprietary telephone user to return all the following items programmed on the telephone to default setting.Programming Items Bilingual Display Selection Call Waiting Tone Type Assignment Full One-Touch Dialing Assignment Handset / Headset Selection Initial Display Selection Intercom Alert Assignment Live Call Screening Mode Set Preferred Line Assignment - Incoming Preferred Line Assignment - OutgoingDefault English Display Tone 1 On Handset Caller ID Tone Call Hands-free Ringing Line Intercom Line Station Programming is used to set or cancel these items at individual telephones. ConditionsNone Programming References Station Programming. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .User Manual Station Programming Data Default Set Feature ReferencesSection 3, Features Station Programming Operation References Not applicable. 3- 142Features
Features Station Speed Dialing DescriptionAllows an extension user to store frequently dialed numbers in order to place a call with abbreviated dialing. It is performed by dialing the feature number and a speed dial number from 0 through 9. Up to 10 numbers can be stored in each telephone. Conditionsl Station Speed Dialing can be followed by manual dialing to supplement the dialed digits. l You may make a call with One-Touch Dialing button, instead of Station Speed Dialing. l The standard telephone may be replaced with a proprietary telephone (PT) temporarily to store one-touch dialing into memory. The Function Buttons Fl through FlO correspond to speed dial numbers as follows: Fl - 0F6 - 5 F2-1F7-6F3 - 2F8 - 7 F4 - 3F9-8F5 - 4FlO-9 Programming References Section 4, System Programming [lOOI Flexible Numbering, Station speed dialing, Station speed dialing programming Feature ReferencesSection 3, Features One-Touch Dialing Operation ReferencesDPT Features, Standard Telephone Features-User MantidStation Speed Dialing Features3-143
S System Data Default Set 3Features DescriptionThis system permits re-initialization of system-programmed data. If all the programmed data is cleared, the system will restart with the default setting. ConditionsThe default setting for each programming item is listed in Section 5.2, “Default Values”. Programming References Section 4, System Programming [900] System Data Clear Feature ReferencesNone Operation ReferencesSection 2, Installation 2.9 System Data Clear3-144Features
3FeaturesS System Programming with Proprietary Telephone DescriptionThis system can be programmed with a proprietary telephone (PT). Proprietary telephones available for System Programming are: KX-T7235; KX-T7230; KX-T7 130; and a-T7030 (Display Proprietary Telephones). Two extensions are allowed to perform System Programming. The available extensions are: (1) An extension that is connected to jack 1. (2) An extension that is assigned as a manager. For more information and programming instructions, refer to Section 4, “System Programming”. Conditionsl During System Programming the system operates normally. l During System Programming the extension is considered to be busy. l The display on the PT permits interactive programming. l Access to System Programming is allowed only one at a time. l To access system administration, a valid password must be entered. The password is factory-programmed and can be changed. Programming References Section 4, System Programming [006] Operator / Manager Extension Assignment [ 1071 System Password Feature ReferencesNone Operation References Not applicable.Features 3-145
SFeatures., System Speed Dialing DescriptionThis feature supports 100 abbreviated dial numbers that are available to all users. A system speed dial number is dialed out by pressing the AUTO button and a 2-digit code (00 through 99). It is possible to store one hundred 24-digit telephone numbers per system (maximum). Conditions. Overriding Toll Restriction for System Speed Dialing can be activated or deactivated by system programming. @?or proprietary telephone users only] l Speed Dialing, One-Touch Dialing, manual dialing, Last Number Redial and Saved Number Redial can bc used in combinations. For standard telephone users only] l If a stored feature number includes “ * ” or “#“, rotary single line telephones cannot use it. Programming References Section 4, System Programming [OOl] System Speed Dialing Number Set [002] System Speed Dialing Name Set [ 1001 Flexible Numbering, System speed dialing [300] IRS Override for System Speed Dialing Feature ReferencesSection 3, Features Toll Restriction Override for System Speed Dialing Operation ReferencesDPT Features, Standard Telephone Features-User Manual System Speed Dialing3-146 Features
FeaturesS System Working Report DescriptionThe Digital Super Hybrid System automatically records the system’s working status condition. A printer connected to the Serial Interface (RS-232C) port can be used to print the recorded data. The recorded data can be printed out by the operator or manager. Recorded contents are as follows: 1. Date of record l The date and time when cleared l The date and time when printed out 2. Incoming calls l The number of incoming calls l The number of answered incoming calls l The ratio of answered calls to incoming calls Number of answered calls Number of incoming callsx 100 (%) l The average time from receipt of call to answer of the incoming and answered calls l The average talk duration of the answered calls 3. Outgoing calls l The number of requested accesses l The number of successful accesses l The ratio of successful accesses to requested accesses Number of successful accesses Number of requested accessesx loo (%) l The average duration of the dialed calls These records can be deleted by the operator or manager and new data will be recorded thereafter. Conditionsl Connect a printer to the Serial Interface (RS-232C) connector to the main unit. l Referring and deleting the system working report can be done using a serial interface. Connection References Section 2, Installation 2.3.9 Printer and PC Connection Features3-147
SFeatures Programming References Section 4, System Programming [ 1001 Flexible Numbering, System working report [806] Serial Interface (RS-232C) Parameters Feature ReferencesSection 3, Features Station Message Detail Recording (SMDR) Operation ReferencesOperator / Manager Service Features-User Manual System Working Report 3- 148Features
3FeaturesTime-out, VariableT DescriptionProvides timers to control various features or functions. The following timers are programmable:System Timer Items Range Automatic Redial Interval Timenx lOs, n:3 - 120 Automatic Redial Repeated Times1 - 30 times Call Forwarding - No Answer Time-Out1 - 12 rings Call Park Recall Time 3 - 48 rings DISA AA Wait Time1-5s DISA Delayed Answer Time0 - 6 rings Extension-to-Outside Call Duration Time1 - 64 min Hold Recall Time0-240s Intercept Routing Time-Out 3 - 48 rings Message Waiting Ring Interval Time0-64min Outside Line Dial Starting Timenx 100 ms, n:O - 40 Outside-to-Outside Line Call Duration Time1 - 64 min Pickup Dialing Waiting Time1-5s SMDR Duration Count Starting Time0-60s Timed Reminder Alarm Ring Time30-240s Toll Restriction First Digit Time-Out5-120s Toll Restriction Inter-digit Time-Out5-30s Transfer Recall Time0 - 48 ringsOutside Line Group Timer Items Disconnect Time Hookswitch Flash Time 1.5 / 4.0 s Disable/80/96/ 112/ 200/300/400/500/ Pause TimeOutside Line Timer Items CPC Signal Detection Time (Incoming) ms DTMF Digit TimeExtension Timer Items Delayed Ringing Count 600/700/800/900/ lOOO/ llOO/ 1200ms 1.5 / 2.5 13.5 14.5 s Disable / 100 / 200 / 300/400/500/600 80/ 160 ms Disable / Immediate / 1/3/6rings/Noring Features3-149
T3Features ,,,,,Voice Mail Integration Timer Items DTMF Signal Duration DTMF Signal Waiting Time after VPS Answer 80 / 160 ms0.5 / 1.0 / 1.5 / 2.0 s DTMF Signal Waiting Time after VPS calls Extension0.5 / 1.0 / 1.5 / 2.0 s Programming References Section 4, System Programming [200] Hold Recall Time [201] Transfer Recall Time [202] Call Forwarding - No Answer Time [203] Intercept Time [204] Pickup Dial Waiting Time [205] Extension-to-Outside Line Call Duration Time [206] Outside-to-Outside Line Call Duration Time [207] First Digit Time [208] Inter Digit Time [209] Automatic Redial Repeat Times [210] Automatic Redial Interval Time [211] Dial Start Time [212] Call Duration Count Start Time [213] DISA Delayed Answer Time [216] Message Waiting Ring Interval Time. [2 171Timed Reminder Alarm Ring Time [218] DISA AA Wait Time [219] Call Park Recall Time [404] DTMF Time [405] CPC Signal Detection Incoming Set [4 121 Pause Time [413] Flash Time [414] Disconnect Time [603]-[604] DIL 1 :N Extension and Delayed Ringing - Day / Night [990] System Additional Information, Fields (6) through (8) Feature ReferencesNone Operation References Not applicable.3-150Features