CP- SINGLE RING OPX (BY2:7) Description Use this option to enable (0) or disable (1) Distinctive Ringing for ports with circuit types 05 and 51 (OPX and ASI extensions). If enabled (0), trunk calls have two short rings (repeated) followed by a pause. Intercom calls have a single one second ring followed by a pause. If disabled (1), Intercom and trunk calls have a single one second ring followed by a pause. In >AUX Y2.1/Base Y5.1, use this option to control the types of calls Voice Mail Personal Answering Machine Emulation answers. If enabled (1), Personal Answering Machine Emulation answers only trunk calls. Intercom calls to the extension go through normally. If disabled (0), Personal Answering Machine Emulation answers all calls (Intercom and trunk). For more information, refer to the Voice Mail Compatibility feature. Conditions None Default Value Distinctive Ringing enabled (0). Feature Reference Distinctive Ringing, Tones and Flash Patterns Instructions To enter data on the PRF: 1. On Table 2 for BY2:7, enter 0 allow Distinctive Ringing at circuit type 05/51 ports. Enter 1 to prevent Distinctive Ringing. OR On Table 2 for BY3:6, enter 0 to have Personal Answering Machine Emulation answer all calls to an extension. Enter 1 to have Personal Answering Machine Emulation answer only trunk calls. To enter data at the programming terminal: 1. Type CP. You see: COS # 00: 00010000 00000-0 00000001 00000000 2. Enter data for each COS you want to program. C- CLASS OF SERVICE CP- SINGLE RING OPX (BY2:7) 324 PROGRAMMING N1870SWG04 Issue 1-0
CP- INHIBIT FLASH FOR SINGLE LINE TELEPHONES (BY2:6) Description Use this option to enable (0) or disable (1) Flash for ESL sets with this COS. If enabled, ESL users can press and release the hookswitch to Flash a trunk. Note: If you are using BY2:6 to assign an ACD supervisor keyset, go to CP- ACD Supervisor Keyset (BY2:6) on the next page. Conditions None Default Value Flash allowed at ESL sets (0). Feature Reference Flash Instructions To enter data on the PRF: 1. On Table 2 for BY2:6, enter 0 allow Flash at ESL sets. Enter 1 to prevent Flash at ESL sets. To enter data at the programming terminal: 1. Type CP. You see: COS # 00: 00010000 00000-0 00000001 00000000 2. Enter data for each COS you want to program. C- CLASS OF SERVICE CP- INHIBIT FLASH FOR SINGLE LINE TELEPHONES (BY2:6) N1870SWG04 Issue 1-0 PROGRAMMING 325
CP- ACD SUPERVISOR KEYSET (BY2:6) Description Use this option to assign extensions with this COS as ACD supervisor keysets. This option only identifies the extension as a supervisor. It does not assign the keyset to an ACD group (see Related Programming below). If enabled (1), extension is an ACD supervisor. If disabled (0), extension is not a supervisor. Conditions None Default Value ACD supervisor not assigned (0). Feature Reference Automatic Call Distribution Instructions To enter data on the PRF: 1. On Table 2 for BY2:6, enter 0 if the keyset is not an ACD group supervisor. Enter 1 if the keyset is an ACD supervisor. To enter data at the programming terminal: 1. Type CP. You see: COS # 00: 00010000 00000-0 00000001 00000000 2. Enter data for each COS you want to program. C- CLASS OF SERVICE CP- ACD SUPERVISOR KEYSET (BY2:6) 326 PROGRAMMING N1870SWG04 Issue 1-0
CP- ALLOW SILENT MONITOR (BY2:5) Description Use this option to allow (1) or prevent (0) Silent with this COS from initiating Silent Monitor. Conditions None Default Value Silent Monitor not allowed (0). Feature Reference Silent Monitor Instructions To enter data on the PRF: 1. On Table 2 for BY2:5, enter 0 to prevent extensions from initiating Silent Monitor. Enter 1 to allow ex- tensions to initiate Silent Monitor. To enter data at the programming terminal: 1. Type CP. You see: COS # 00: 00010000 00000-0 00000001 00000000 2. Enter data for each COS you want to program. C- CLASS OF SERVICE CP- ALLOW SILENT MONITOR (BY2:5) N1870SWG04 Issue 1-0 PROGRAMMING 327
CP- INHIBIT ACCESS TO PAGE ZONE 3 (BY2:4) Description Use this option to allow (0) or prevent (1) extensions with this COS from broadcasting announcements into Paging zone 3. This option also applies to DISA trunks. Conditions None Default Value Access to Page Zone 3 allowed (0). Feature Reference Paging Tenant Service Instructions To enter data on the PRF: 1. On Table 2 for BY2:4, enter 0 to allow extensions Paging into zone 3. Enter 1 to restrict extensions from Paging into zone 3. To enter data at the programming terminal: 1. Type CP. You see: COS # 00: 00010000 00000-0 00000001 00000000 2. Enter data for each COS you want to program. C- CLASS OF SERVICE CP- INHIBIT ACCESS TO PAGE ZONE 3 (BY2:4) 328 PROGRAMMING N1870SWG04 Issue 1-0
CP- INHIBIT ACCESS TO PAGE ZONE 2 (BY2:3) Description Use this option to allow (0) or prevent (1) extensions with this COS from broadcasting announcements into Pag- ing zone 2. This option also applies to DISA trunks. Conditions None Default Value Access to Paging zone 2 allowed. Feature Reference Paging Tenant Service Instructions To enter data on the PRF: 1. On Table 2 for BY2:3, enter 0 to allow extensions Paging into zone 2. Enter 1 to restrict extensions from Paging into zone 2. To enter data at the programming terminal: 1. Type CP. You see: COS # 00: 00010000 00000-0 00000001 00000000 2. Enter data for each COS you want to program. C- CLASS OF SERVICE CP- INHIBIT ACCESS TO PAGE ZONE 2 (BY2:3) N1870SWG04 Issue 1-0 PROGRAMMING 329
CP- INHIBIT ACCESS TO PAGE ZONE 1 (BY2:2) Description Use this option to allow (0) or prevent (1) extensions with this COS from broadcasting announcements into Paging zone 1. This option also applies to DISA trunks. Conditions None Default Value Access to Paging zone 1 allowed. Feature Reference Paging Tenant Service CP- INHIBIT ACCESS TO PAGE ZONE 1 (BY2:2) Instructions To enter data on the PRF: 1. On Table 2 for BY2:2, enter 0 to allow extensions Paging into zone 1. Enter 1 to restrict extensions from Paging into zone 1. To enter data at the programming terminal: 1. Type CP. You see: COS # 00: 00010000 00000-0 00000001 00000000 2. Enter data for each COS you want to program. C- CLASS OF SERVICE CP- INHIBIT ACCESS TO PAGE ZONE 1 (BY2:2) 330 PROGRAMMING N1870SWG04 Issue 1-0
CP- INHIBIT ACCESS TO ALL CALL PAGING (BY2:1) Description Use this option to allow (0) or prevent (1) extensions with this COS from broadcasting All Call Paging an- nouncements. This option also applies to DISA trunks. Conditions None Default Value Access to All Call Paging allowed. Feature Reference Paging Tenant Service Instructions To enter data on the PRF: 1. On Table 2 for BY2:1, enter 0 to allow extensions All Call Paging. Enter 1 to restrict extensions from All Call Paging. To enter data at the programming terminal: 1. Type CP. You see: COS # 00: 00010000 00000-0 00000001 00000000 2. Enter data for each COS you want to program. C- CLASS OF SERVICE CP- INHIBIT ACCESS TO ALL CALL PAGING (BY2:1) N1870SWG04 Issue 1-0 PROGRAMMING 331
CP- DIRECT TRUNK ACCESS AND TRUNK CAMP-ON (BY2:0) Description Use this option to enable (1) or disable (0) Direct Trunk Access for extensions with this COS. If allowed, exten- sions can also use Forced Trunk Disconnect. Additionally, extensions with Direct Trunk Access capability can dial 2 to Camp-On to a busy trunk. This option also allows extensions to program System Speed Dial numbers. Conditions None Default Value •Direct Trunk Access allowed (1) for COS 0. •Direct Trunk Access not allowed (0) for all other COSs. Feature Reference Call Waiting (Camp-On) Direct Trunk Access Forced Trunk Disconnect Instructions To enter data on the PRF: 1. On Table 2 for BY2:0, enter 0 to prevent extensions with this COS from using Direct Trunk Access. En- ter 1 to allow extensions with this COS to use Direct Trunk Access. To enter data at the programming terminal: 1. Type CP. You see: COS # 00: 00010000 00000-0 00000001 00000000 2. Enter data for each COS you want to program. C- CLASS OF SERVICE CP- DIRECT TRUNK ACCESS AND TRUNK CAMP-ON (BY2:0) 332 PROGRAMMING N1870SWG04 Issue 1-0
D- DISPLAY MEMORY Description This program displays the contents of system memory locations. It is a factory diagnostic tool, not intended for field use. Consult your Field Service representative for more information. Conditions None Default Value None Feature Reference System Reports, Diagnostics and Maintenance Utilities Instructions None D- DISPLAY MEMORY N1870SWG04 Issue 1-0 PROGRAMMING 333