Mitel SX-200 DIGITAL Pabx General Description Manual
Have a look at the manual Mitel SX-200 DIGITAL Pabx General Description Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 55 Mitel manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
![](/img/blank.gif)
Features Description Dial-In Tie Recall Point on No Answer -A Dial-In Tie call reaching an extension which does not answer will be routed here. This is based on the destination tenant. Dial-In Tie Routing for All Calls into this Tenant -All Dial-In Tie calls normally routed to extensions will be routed here to allow screening of Dial-In Tie calls. This is based on the destination tenant. Dial-In Tie Intercept for Galls into this Tenant -A Dial-In Tie cali to an illegal number will be routed here. This is based on the Tie trunks tenant. Dial-In Tie Vacant Number Routing for this Tenant -A Dial-In Tie call to a vacant number will be routed here. This is based on the Tie trunk’s tenant. Dial-In Tie Attendant Access Night Points -A Dial-In Tie call to the attendant while this system is in NIGHT service will be routed here. This is based on the Tie trunk’s tenant. Do Not Disturb Intercept Routing for this Tenant -An extension with Do Not Disturb activated will have its incom- ing calls routed here. This is based on the extension’s tenant. Automatic Wake-up Routing for this Tenant -All extensions (not SUPERSET qTM sets) answering a wakeup call will be routed here. Normally this will be a recording group. This is based on the extension’s tenant. UCD Recording Routing for this Tenant -Incoming calls destined for UCD Agents are routed here when all of the Agents are busy. This would normally be a recording group. See UNIFORM CALL DISTRIBUTION. UCD on Hold Time-out Routing for this Tenant -Incoming calls to busy UCD hunt groups which are not an- swered after a pre-determined time-out period are routed here. See UNIFORM CALL DISTRIBUTION. DISA Day Service Routing for this Tenant -Direct Inward System Access (DISA) calls are routed here. This is based on the DISA trunk’s tenant. Station Vacant Number Routing for this Tenant -Any station dialing a vacant number will be routed here. This is based on the extension’s tenant. Station Illegal Number Routing for this Tenant -Any station dialing an illegal number will be routed here. This is based on the extension’s tenant. Page C-2/2
![](/img/blank.gif)
MITEL STANDARD PRACTICESECTION MITL9108-093-150-NAIssue 2, September 1986 SX-200” DIGITAL PRIVATE AUTQMATIC BRANCH EXCHANGE (PABX) ORDERCNG INFORMATION \Copyright of MITEL Corporation 4986 TM - Trademark of MITEL Corporation @Registered Trademark of MITEL Corporation i
![](/img/blank.gif)
Ordering information CONTENTSPAGE1. INTRODUCTION . . . . . . . . . . e . . . . . . . . . . . . . 0 . . 0 . . . . . . . l-l ReasonforReissue. . . . O.e . . . . . . . . . Sun . . . . . . . . . ~.. l-l 2. ORDERING INFORMATION . . m . . . . . . . . . 0 0.. 0 m. e 0 0. s s . . 2-l Warranty . . . ..=...m.V...m.O....a...D s....O.m m O..m 2-1 Spares Level D . . . . . . . . . . . . . . . . . . . . . . m . . . =. . . . . . 0 . . 2-l TABLE TITLEPAGE2-lBasic System Equipment - 336-Port 2-2 2-3 2-4 2-5 2-6 2-7 2-8 2-9 2-102-l 1Configuration D D . . . . m D *. -. . . . . Q -. . . . . . . . . . ~ 2-2 Expansion Kits - 336-Port Configuration . . , . . . , . s , 2-2 Digital Peripheral Cards . . ~ . . a . . . . . . . . s . . . . . . ~ . 2-3 Spares - 336-Port Configuration . . . D . . . . . . , . . . . 0 2-3 Basic System Equipment - 489-Port Configuration . a 2-4 Expansion Kits - 480-Port Configuration . . . . . . . . 0 m 2-5 Upgrade Kit0 . . . m e D . -. . . 0 s 0 m. . =. = . *. . . . . . . . . 2-6 Analog Peripheral Cards n 0 Q m u D . . a m . . . . 0 . . . . . . a . 2-6 Spares - 480-Port Configuration . . a . . . . D . . D a . . . . 2-7 Peripheral Equipment . . ~ ~ ~. . . -. . a r . . . . . . . . ~ ~ . . 2-8 Documentation . m ~ D 0 m ~ m 0 D D 0 D = m e = D m m m D D. . ~ . . ~ ~ 2-9 LIST OF TABLES
![](/img/blank.gif)
0,rdgring Information 1. INTRODUCTION 1 .OlThis Section contains the ordering information for the SX-200@DIGITAL Private Automatic Branch Exchange (PABX). Reason for Reissue 1.02 This document is reissued to provide hardware and software orderable part numbers for the SX-200@ DIGlTAL PABXs, with Generic 1000 and Generic 1001 software. Both the 336-port fully digi- tal configuration and the 480-port configuration are described. Page l-l/l
![](/img/blank.gif)
Ordering Information 2. ORDERING INFQRMATIDN 2.01The ordering information is divided into the following tables: Table 2-l lists the components of the 336-port configuration. Table 2-2 lists expansion kits for the 336-port configuration. Table 2-3 lists all digital cards and modules required to com- plete the customer requirements. Table 2-4 lists spares for the 336-port configuration. Table 2-5 lists the components of the 480-port configuration. Table 2-6 lists expansion kits for the 480-port configuration. Table 2-7 lists the upgrade kit. Table 2-8 lists all analog cards required to complete the cus- L tomer requirements. Table 2-9 lists spares for the 480-port configuration. Table 2-10 lists all peripheral equipment. Table 2-11 lists the system documentation Warranty 2.02 The MITEL SX-ZOO@ DIGITAL communications system is war- ranted against defective material and workmanship. Equipment requiring service or repair during the warranty period must be pack- aged in accordance with Section MITL9108-093-ZOO-NA, Shipping, Re- ceiving, and Installation Information, and returned prepaid to the sup- plier. Repaired or replacement equipment is returned to the customer, post prepaid by MITEL. Spares Level 2.03 MITEL recommends that a minimum spares level of 10% of installed systems, including 10% sparing of the basic system, be maintained. The sparing recommended for the Memory Module is 5%. This means that service personnel can carry a complete spare system on field trips, and therefore, if required, replace a complete system. Page 2-4
![](/img/blank.gif)
Ordering Information TABLE 2-1 BASIC SYSTEM EQUIPMENT - 336-PORT CONFIGURATION BlankRearDoorwithfans 336-Port Software TABLE 2-2 Page 2-2
![](/img/blank.gif)
Ordering Information TABLE 2-3 DIGITAL PERIPHERAL CARDS Marketing Name ONS Line Card (12 Circuit) COV Line Card OPS Line Card LS/GS Trunk Card DID Trunk Universal Card Receiver/Relay Module 9109-016-OOO-NAMusic On Hold/Pager Module Console Module E&M Trunk ModulePart Number 9109-OlO-OOO-NA 9 109-020-OOO-NA 9 109-040-OOO-NA 9109-Oil-OOO-NA 9109-031-OOO-NA 9109-005-OuO-NA 9109-018-OOO-NA 9 109-025-OOO-NA 9109-013-OOO-NAComments for Rotary and DTMF sets 6 COV Circuits per card 6 OPS Circuits per card 6 CO Trunk Interfaces 6 DID Circuits per card supports: - E&M Trunk Module - Music On Hold/Pager Module - Receiver/Reiay Module - Console Module 4 DTMF Receivers 2 General Purpose Relays Music Input Paging Preamp Output Relay to control external amplifier Console Interface E&M Trunk Circuit per Module TABLE 2-4 SPARES - 33%PORT CONFIGURATION Marketing Name Control Shelf AssemblyPart Number 9108-014-OOO-NAComments Spare PCM Cable Peripheral Bay Shelf Assembly 9 109-050-OOO-NA9109-O 15-OOO-NAPeripheral Bay Backplane Assembly 9109-044-OOO-tiA Spare Fan9109-032-OOO-NAReplacement Filter 9 109-037-OOO-NAFloppyDisk Drive Assembly 9109-124-OOO-NASpare Diskettes Gene& 1001 336-Port9109-034-OOO-NA 3 Floppy Diskettes I . Main Control Card Bav ControlCard 9109-003-OOO-NA 9 109-O 17-OOO-NAPower Fail Transfer Card ) 9109-023-OOO-NA 16 Power Fail Transfer CircuitsIPage 2-3
![](/img/blank.gif)
Ordering Information TABLE 2-5 BASIC SYSTEM EQUIPMENT - 480-PORT CONFiGURATIONBasic System (Bay 1 br 2) Blank Rear Door Main Control Card with DX and Memory SX-ZOO@ DIGITAL Cabinet SX-ZOO@ DIGITAL Power Supply Control Shelf Cardfile and Backplane Bay 3 Shelf and Backplane BayPower Supply Main ControlCard Digital Interface Card Peripheral Control Card Scanner Card 1000 Software 100 1480-PortSoftware Page 2-4
![](/img/blank.gif)
Ordering Information TABLE 2-6 EXPANSION KITS - 480-PORT CONFIGURATION Bay 4 Shelf and Backplane Digital Interface Card Peripheral Control Card Scanner Card Bay 2-4 PCM Cable Bay 4 Hardware Kit Interconnect Card with Cables r Card (12 PFT Circuits) and PFT ddress/Data Cables Set cuits)PFT Cables Page 2-5
![](/img/blank.gif)
Ordering Information TABLE 2-7UPGRARE KIT rKit, lessSoftware SX-ZOO@DIGITAL Power Supply Bay Power Supply Floppy Disk Drive interconnect Card and Cables Cutover Card (12 PFT Circuits) Main Control Card with DX and Memory Digital Interface Card Peripheral Control Card Universal Card Console Module Receiver/Relay Module MOH/Paging Module LCD Console TABLE 2-8 PERIPHERAL CARDS DID/TIE Trunk Card Scanner Card (1200 BAUD) 91 -lO-104-OOO-MALine Card (a-station)9110-l IO-OOO-NA CO Trunk Card SUPERSET@ Line Card91 lo-410-OOO-NASUPERSET sTM and SUPERSEP qT’Page 2-6