    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 5, CallVisor, ASAI Protocol Reference Instructions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 600
    							8. Call Redirection
    Issue 6 June 1997
    B-63
    REG [CRV=79, FIE(Invoke,
    Inv_id=1, Request Feature,
    feature=Cancel Call
    Forwarding,
    redirecting number=3569)]AP Cancels Call
    Forwarding for
    Station 3569
    REL COMP[CRV=79, FIE(Return
    Result, Inv_id=1)]Call Forwarding
    Cancelled
    Messages Sent by the 
    Adjunct ProcessorMessages Sent
    by the Switch Comments 
    						
    							Message Scenarios
    B-64Issue 6 June 1997 
    Incoming Call to Station Forwards to VDN
    This scenario shows the call flow for a call from station 3001 to station 2345 that 
    has call forwarding active to VDN 405 (see Figure B-25). VDN 405 routes the call, 
    via the Adjunct Routing vector command, to VDN 5678. VDN 5678 routes the call, 
    via the Adjunct Routing vector command, to extension 9800. 
    VDN 405 is not monitored by the adjunct. VDN 5678 has Event Notification active 
    as presented in the initialization scenario.
    Figure B-25. Call Flow for Incoming Call to Station Forwarded to VDN
    DEFINITY ECS
    x9800
    x3001x2345call_id=67
    VDN 405
    VDN 5678Vector E
    1. Adjunct Routing
    2. Wait 4 Seconds
    3. Busy
    4.
    Vector A
    1. Collect Digits
    2. Adjunct Routing
    3. Wait 4 Seconds
    4. Route to 0 
    						
    							8. Call Redirection
    Issue 6 June 1997
    B-65
    Messages Sent by the 
    Adjunct ProcessorMessages Sent
    by the Switch Comments
    REG [CRV=32, FIE(Invoke,
    Inv_id=4, Route,
    call_id=67,
    calling number=3001, 
    called number=2345,
    domain=VDN 405)]Route Request
    FAC [CRV=32, FIE(Invoke,
    Inv_id=3, Route Select,
    called number=5678)]Route to VDN
    5678
    REL COMP [CRV=32, FIE(Invoke,
    Inv_id=6, Route End,
    cause=normal)]Call Routed
    FAC [CRV=98, FIE(Invoke,
    Inv_id=24, Event Report,
    call_id=67,
    event=call offered,
    calling number=3001,
    called number=2345,
    domain=VDN 5678)]Call Offered to
    VDN 5678
    REG [CRV=90, FIE(Invoke,
    Inv_id=2, Route,
    call_id=67,
    calling number=3001, 
    called number=2345,
    domain=VDN 5678,
    user code=1233)]Route Request
    (Continued on next page) 
    						
    							Message Scenarios
    B-66Issue 6 June 1997 
     
    Messages Sent by the 
    Adjunct ProcessorMessages Sent
    by the Switch Comments
    FAC [CRV=90, FIE(Invoke,
    Inv_id=3, Route Select,
    called number=9800)]Route to Station
    9800
    REL COMP [CRV=90, FIE(Invoke,
    Inv_id=4, Route End,
    cause=normal)]Call Routed
    FAC [CRV=98, FIE(Invoke,
    Inv_id=26, Event Report,
    call_id=67, party_id=2,
    event=alerting,
    calling number=3001, 
    called number=2345,
    connected number=9800)]Alerting Event Report
    (Call Alerts Station
    9800)
    FAC [CRV=98, FIE(Invoke,
    Inv_id=28, Event Report,
    call_id=67, party_id=2,
    event=connected,
    calling number=3001, 
    called number=2345,
    connected number=9800)]Connected Event Report
    (Station 9800 Answers)
    FAC [CRV=98, FIE(Invoke,
    Inv_id=9, Stop Call
    Notification, call_id=67)]Stop Event Reports
    for Call over 
    Notification Association
    FAC [CRV=98, FIE(Return
    Result, Inv_id=9)]Event Reporting
    for Call Terminated 
    						
    							8. Call Redirection
    Issue 6 June 1997
    B-67
    Incoming Call to ACD Split Forwards to Hunt 
    Group
    This scenario shows the call flow for an incoming ISDN PRI call to ACD split 3456 
    (see Figure B-26). ACD split 3456 has call forwarding active to hunt group 2000. 
    Member 2005 of the hunt group 2000 receives the call.
    ACD split 3456 has Event Notification active as presented in the initialization 
    scenario. The adjunct processor does not have Event Notification active for Hunt 
    Group 2000. 
    Figure B-26. Call Flow for Incoming Call to ACD Split Forwarded to Another ACD Split
    DEFINITY ECS
    ACD Split
    Hunt Group Incoming Call
    call_id=34
    x6005Agent
    Extension
    Call Forwarding
    Active 3456
    2000 
    						
    							Message Scenarios
    B-68Issue 6 June 1997 
    Messages Sent by the 
    Adjunct ProcessorMessages Sent
    by the Switch Comments
    FAC [CRV=102, FIE(Invoke,
    Inv_id=24, Event Report,
    call_id=34,
    event=call offered,
    calling number=4159703478,
    called number=8095763456,
    domain=ACD Split 3456)]Call Offered to
    ACD Split 3456
    FAC [CRV=102, FIE(Invoke,
    Inv_id=26, Event Report,
    call_id=34, event=queued,
    called number=8095763456,
    calls in queue=1,
    domain=Hunt Group 2000)]Call Queues to
    to Hunt Group 2000
    FAC [CRV=102, FIE(Invoke,
    Inv_id=28, Event Report,
    call_id=34, party_id=2,
    event=alerting,
    calling number=4159703478,
    called number=8095763456,
    connected number=2005,
    domain= Hunt Group 2000)]Alerting Event Report
    (Call Alerts Station
    2005)
    FAC [CRV=102, FIE(Invoke,
    Inv_id=28, Event Report,
    call_id=34, party_id=2,
    event=connected,
    calling number=4159703478,
    called number=8095763456,
    connected number=2005)]Connected Event Report
    (Station 2005 Answers)
    FAC [CRV=102, FIE(Invoke,
    Inv_id+5, Stop Call Notification,
    call_id=34)]  AP Requests to
    Stop Receiving
    Event Reports for the Call
    FAC [CRV=102, FIE(Return
    Result, Inv_id=5)]Event Reporting for
    Call Terminated 
    						
    							8. Call Redirection
    Issue 6 June 1997
    B-69
    Call to Station Goes to Coverage Station
    This scenario shows the call flow for a call from station 6071 to station 3580 (see 
    Figure B-27). After three rings, the call alerts the coverage station (extension 
    3569). The principal station (3580) answers the call (using its simulated bridged 
    appearance) after it has alerted the coverage station.
    Assume that Third Party Domain (Station) Control is active for station 3569 as 
    shown in the Send All Calls scenario above.
    Figure B-27. Call Flow for Incoming Call to Station Redirected to Coverage
    DEFINITY ECS
    x3569
    x6071call_id=16x3580
    Coverage 
    						
    							Message Scenarios
    B-70Issue 6 June 1997 
    Messages Sent by the 
    Adjunct ProcessorMessages Sent
    by the Switch Comments
    REG [CRV=87, FIE(Invoke,
    Inv_id=1, 3P Make Call,
    called number=3580,
    calling number=6071)]AP Requests Make Call
    from Station 6071 to
    Station 3580
    FAC [CRV=87, FIE(Invoke,
    Inv_id=2, Event Report,
    call_id=16, party_id=2,
    event=alerting,
    calling number=6071,
    called number=3580,
    connected number=3580)]Alerting Event Report
    (Call Delivered to
    Station 3580) —
    3P Make Call
    Association
    FAC [CRV=87, FIE(Invoke,
    Inv_id=4, Event Report,
    call_id=16, party_id=3,
    event=alerting,
    calling number=6071,
    called number=3580,
    connected number=3569
    cause=3/28)]
    FAC [CRV=88, FIE(Invoke,
    Inv_id=2, Event Report,
    call_id=16, party_id=3,
    event-alerting,
    calling number=6071,
    called number=3580,
    connected number=3569
    cause=3/28)]
    FAC [CRV-87, FIE(Invoke,
    Inv_id=6, Event Report,
    call_id=16, party_id=2,
    calling number=6071,
    event=connected,
    called number=3580,
    connected number=3580)]
    FAC [CRV=87, FIE(Invoke,
    Inv_id=8, Event Report,
    call_id=16, party_id=3,
    event=drop,
    connected number=3569,
    cause=normal clearing)]Alerting Event Report
    (Call Goes to Coverage,
    Station 3569) —
    3P Make Call
    Association
    Alerting Event Report
    (Call Goes to Coverage,
    Station 3569) —
    x3569 Association
    Connected Event Report
    (Station 3580 Answers
    Call)
    Drop Event Report
    (Coverage 3569 Dropped)—
    3P Make Call
    Association
    (Continued on next page) 
    						
    							8. Call Redirection
    Issue 6 June 1997
    B-71
    Messages Sent by the 
    Adjunct ProcessorMessages Sent
    by the Switch Comments
    FAC [CRV=88, FIE(Invoke,
    Inv_id=4, Event Report,
    call_id=16,
    event=call redirected)]Call Redirected Event
    Report (Principal 3580
    Picked Up the Call) —
    x3569 Association
    FAC [CRV=87, FIE(Invoke,
    Inv_id=3, 3P Selective Drop,
    party_id=2)]AP Requests to
    Drop Station 3580
    from Call
    FAC [CRV=87, FIE(Return
    Result, Inv_id=3)]
    REL COMP [CRV=87, FIE(Invoke,
    Inv_id=10, Call Ended,
    call_id=16, cause = normal)]Station 3580
    Dropped
    Call Terminated 
    						
    							Message Scenarios
    B-72Issue 6 June 1997 
    Incoming Call to Station Sent to Coverage with
    Send All Calls (SAC)
    This scenario shows the call flow for a call from station 3568 to station 3569 (see 
    Figure B-28). After alerting at station 3569, the user at station 3569 activates 
    Send All Calls (SAC) and redirects the call to coverage (station 6056). Station 
    3569 maintains a simulated bridged appearance for the call, but does not connect 
    to the call.
    Stations 3568 and 3569 have Domain (Station) Control active.
    Figure B-28. Incoming Call to Station Sent to Coverage via Send All Calls (SAC)
    DEFINITY ECS
    x6056
    x3568call_id=18x3569
    Coverage Send All Calls
    Activated 
    						