    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 5, CallVisor, ASAI Protocol Reference Instructions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 600
    							Event Reports
    Issue 6  June 1997
    5-17
    Call Redirected Event Report
    Byte Description Byte Value Comments
    Protocol Discriminator 0x08 BRI
    CRV Length 0x01 or 0x02
    First CRV Byte 0x?
    Second CRV Byte0x?
    Message Type 0x62 FACility
    Locking Shift to Code Set 6 0x96
    Facility IE 0x1c
    Length of Facility IE 0x?? computed length
    Q.932 Supplementary Service 0x91
    component type tag 0xa1 INVOKE component
    component length 0x?? computed length
    component length0x?? long form (length > 127)
    invoke identifier tag 0x02
    invoke identifier length 0x01
    invoke identifier 0x?? even value
    operation value tag 0x02
    operation value length 0x01
    Operation Value = Event Report 0x95
    Q.931 IEs tag 0x40
    Q.931 IEs length 0x?? computed length
    Q.931 IEs length0x?? long form (length > 127)
    Call Identity IE 0x10
    Length of Call Identity 0x02 computed value
    * Call identifier (2 bytes) 0x?? switch-assigned value
    Locking Shift to Code Set 6 0x96
    The Specific Event IE 0x47
    The length of the Specific Event IE 0x01
    Event value = Redirected  0x99 
    						
    							Byte Level Messages
    5-18Issue 6  June 1997 
    Call Transferred Event Report
    (Continued on next page) Byte Description Byte Value Comments
    Protocol Discriminator 0x08 BRI
    CRV Length 0x01 or 0x02
    First CRV Byte 0x?
    Second CRV Byte0x?
    Message Type 0x62 FACility
    Locking Shift to Code Set 6 0x96
    Facility IE 0x1c
    Length of Facility IE 0x?? computed length
    Q.932 Supplementary Service 0x91
    component type tag 0xa1 INVOKE component
    component length 0x?? computed length
    component length0x?? long form (length > 127)
    invoke identifier tag 0x02
    invoke identifier length 0x01
    invoke identifier 0x?? even value
    operation value tag 0x02
    operation value length 0x01
    Operation Value = Event Report 0x95
    Q.931 IEs tag 0x40
    Q.931 IEs length 0x?? computed length
    Q.931 IEs length0x?? long form (length > 127)
    * The Connected Number IE 0x0c
    * Length of IE  0x?
    * Ext bit | Type | Numbering plan 0x80
    * * Address digits 0x??  0x30 thru 0x39, 0x23(#), 0x2a(*)
    Call Identity IE 0x10“other” call ID before transfer
    Length of Call Identity 0x02 computed value
    * Call identifier (2 bytes) 0x?? switch-assigned value
    Call Identity IE 0x10 “resulting” call ID after transfer
    Length of Call Identity 0x02 computed value
    * Call identifier (2 bytes) 0x?? switch-assigned value 
    						
    							Event Reports
    Issue 6  June 1997
    5-19
    NOTES:
    The Call Identity IE containing the “other” call ID before the transfer operation 
    must precede the Call Identity IE that contains the “resulting” call ID after the transfer 
    operation.
    There must be the same number of Party ID IEs, Old Party ID IEs, and Connected 
    Number IEs.
    The Nth Party ID IE and the Nth Old Party ID IE correspond to the Nth Connected 
    Number IE (and thereby associate an extension with that party).
    To preserve a 1:1 correspondence, if the type/address for a party is unknown, a 
    Connected Number IE is present for that party, but the length byte is coded as zero 
    (and no bytes follow).Call Transferred Event Report — (continued)
    Byte Description Byte Value Comments
    Calling Party Number 0x6c
    Length of Calling Party IE 0x? computed length
    Address Type & numbering Plan Id 0x?? 0x80, 0x90, 0x81, 0x91, 0xa0, or 
    0xa1
    * Address digits 0x??  0x30 thru 0x39, 0x23(#), 0x2a(*)
    Called Party Number IE 0x70
    Length of Called Party Number 0x? computed length
    Address Type & Numbering Plan 0x?? 0x80, 0x90, 0x81, 0x91, 0xa0, or 
    0xa1
    * Address digits 0x??  0x30 thru 0x39, 0x23(#), 0x2a(*)
    Locking Shift to Code Set 6 0x96
    * Old Party Identifier IE 0x17 Up to six old party IDs
    * Length of the IE  0x02 or 0x03
    * From Call 0x?? 0x80 or 0xc0
    * Ext bit | Party ID 0x??
    * Ext bit | Party ID (second byte)0x??
    * The Party Identifier IE 0x44 Up to six party IDs
    * Length of the IE  0x01or 0x02
    * Ext bit | Party ID 0x?? 
    * Ext bit | Party ID (second byte)0x??
    The Specific Event IE 0x47
    The length of the Specific Event IE 0x01
    Event value = Transferred 0x93 
    						
    							Byte Level Messages
    5-20Issue 6  June 1997 
    Charging Event Report
    (Continued on next page) Byte Description Byte Value Comments
    Protocol Discriminator 0x08 BRI
    CRV Length 0x01 or 0x02
    First CRV Octet 0x?
    Second CRV Octet 0x?
    Message Type 0x62 FACility
    Locking Shift to Code Set 6 0x96
    Facility IE 0x1c
    Length of Facility IE 0x?? computed length
    Q.932 Supplementary Service 0x91
    component type tag 0xa1 INVOKE component
    component length 0x?? computed length
    component length 0x?? long form (length > 127)
    invoke identifier tag 0x02
    invoke identifier length 0x01
    invoke identifier 0x?? even value
    operation value tag 0x02
    operation value length 0x01
    Operation Value = Event Report 0x95
    Q.931 IEs tag 0x40
    Q.931 IEs length 0x?? computed length
    Q.931 IEs length 0x?? long form (length > 127)
    Cause IE 0x08
    length of Cause IE 0x? computed length
    Ext bit | coding standard | 
    location0xe1 or 0x81 CCITT or ASAI specific, private
    Cause Value 0x?? cause-dependent
    Call Identity IE 0x10
    length of Call Identity IE 0x02
    *Call Identifier (2 octets) 0x?? switch-assigned value
    Calling Party Number IE 0x6c Charging Number
    length of Calling Party Number 
    IE0x?? computed length
    Address type & numbering plan 0x?? 0x80
    * Address digits 0x?? 0x30 through 0x39, 0x23 (#), 
    0x2a (*) 
    						
    							Event Reports
    Issue 6  June 1997
    5-21
    Charging Event Report — (continued)
    Byte Description Byte Value Comments
    Called Party Number IE 0x70
    length of Called Party Number IE 0x?? computed length
    Address type & numbering plan 0x?? 0x80
    * Address digits 0x?? 0x30 through 0x39, 0x23 (#), 0x2a (*)
    Locking Shift to Code 6 0x96
    Trunk Identification IE 0x0a Outgoing trunk
    length of IE 0x?? computed length
    Direction 0x80 No direction
    * Trunk Group Number 0x?? binary-encoded value
    * Trunk Group Member Number 0x?? binary-encoded value
    Party Identifier IE 0x44 party id of outgoing trunk 
    Length of Party Identifier IE  0x01 or 0x02
    Ext bit | Party ID 0x??
    Ext bit | Party ID (second octet) 0x??
     Specific Event IE 0x47
     Length of Specific Event IE 0x01
    Event Value 0x1E Charging Event
    Data Item IE 0x52 Charge Information
    Length of Data Item IE 0x?? computed length
    Data Item type 0x?? type of charge=0x81(intermediate),
    0x82 (final), or 0x83 (split)
    * Data Item value  0x?? Charge value binary-encoded 
    (0-536,870,880). Can be multiple bytes. 
    Ext bit is set on last byte. 
    						
    							Byte Level Messages
    5-22Issue 6  June 1997 
    Connected Event Report
    (Continued on next page) Byte Description Byte Value Comments
    Protocol Discriminator 0x08 BRI
    CRV Length 0x01 or 0x02
    First CRV Byte 0x?
    Second CRV Byte0x?
    Message Type 0x62 FACility
    Locking Shift to Code Set 6 0x96
    Facility IE 0x1c
    Length of Facility IE 0x?? computed length
    Q.932 Supplementary Service 0x91
    component type tag 0xa1 INVOKE component
    component length 0x?? computed length
    component length0x?? long form (length > 127)
    invoke identifier tag 0x02
    invoke identifier length 0x01
    invoke identifier 0x?? even value
    operation value tag 0x02
    operation value length 0x01
    Operation Value = Event Report 0x95
    Q.931 IEs tag 0x40
    Q.931 IEs length 0x?? computed length
    Q.931 IEs length0x?? long form (length > 127)
    Cause IE 0x08
    Length of Cause IE 0x02
    Ext bit | coding standard | location 0x81 or 0xe1 switch-to-adjunct
    Cause Value 0x??
    The Connected Number IE0x0c
    Length of IE 0x?
    Ext bit | Type | Numbering plan0x?? 0x80, 0x90, 0x81, 0x91, 0xa0, or 
    0xa1
    * Address digits0x??  0x30 thru 0x39, 0x23(#), 0x2a(*)
    Call Identity IE 0x10
    Length of Call Identity 0x02 computed value
    * Call identifier (2 bytes) 0x?? switch-assigned value
    Calling Party Number0x6c
    Length of Calling Party IE0x? computed length 
    						
    							Event Reports
    Issue 6  June 1997
    5-23
    NOTE:
    The Calling Party Number IE and Trunk Identifier IE are mutually exclusive.Connected Event Report — (continued)
    Byte Description Byte Value Comments
    Address Type & numbering Plan Id0x?? 0x80, 0x90, 0x81, 0x91, 0xa0, or 
    0xa1
    *Address digits 0x?? 0x30 through 0x39, 0x23(#), 
    0x2a(*)
    Called Party Number IE 0x70
    Length of Called Party Number 0x? computed length
    Address Type & Numbering Plan 0x?? 0x80, 0x90, 0x81, 0x91, 0xa0, or 
    0xa1
    * Address digits 0x??  0x30 thru 0x39, 0x23 (#), 0x2a (*)
    Locking Shift to Code Set 6 0x96
    Originating Line IE0x01
    Length of OLI0x?? computed length
    *II-Digits0x??
    Trunk Identification IE0x0a
    Length of the IE0x?? computed length
    Direction0x80 no direction
    * Trunk Group Number0x?? binary coded
    * Trunk Group Member Number0x?? binary coded
    The Party Identifier IE 0x44
    Length of the IE  0x01 or 0x02
    Ext bit | Party ID 0x??
    Ext bit | Party ID (second byte)0x??
    The Specific Event IE 0x47
    The length of the Specific Event IE 0x01
    Event value = Connected 0x8b 
    						
    							Byte Level Messages
    5-24Issue 6  June 1997 
    Cut-Through Event Report  
    Byte Description Byte Value Comments
    Protocol Discriminator 0x08 BRI
    CRV Length 0x01 or 0x02
    First CRV Byte 0x?
    Second CRV Byte0x?
    Message Type 0x62 FACility
    Locking Shift to Code Set 6 0x96
    Facility IE 0x1c
    Length of Facility IE 0x?? computed length
    Q.932 Supplementary Service 0x91
    component type tag 0xa1 INVOKE component
    component length 0x?? computed length
    component length0x?? long form (length > 127)
    invoke identifier tag 0x02
    invoke identifier length 0x01
    invoke identifier 0x?? even value
    operation value tag 0x02
    operation value length 0x01
    Operation Value = Event Report 0x95
    Q.931 IEs tag 0x40
    Q.931 IEs length 0x?? computed length
    Q.931 IEs length0x?? long form (length > 127)
    Call Identity IE 0x10
    Length of Call Identity 0x02 computed value
    * Call identifier (2 bytes) 0x?? switch-assigned value
    Progress Indicator 0x1e
    Length of Progress Indicator IE 0x02
    Coding Standard and Location 0x?? 0x80 | data from PRI network
    Progress description 0x?? 0x80 | data from PRI network
    Locking Shift to Code Set 6 0x96
    The Party Identifier IE 0x44
    Length of the IE  0x01 or 0x02
    Ext bit | Party ID 0x?? 
    Ext bit | Party ID (second byte)0x??
    The Specific Event IE 0x47
    The length of the Specific Event IE 0x01
    Event value = Cut Thru  0x82 
    						
    							Event Reports
    Issue 6  June 1997
    5-25
    Disconnect/Drop Event Report
    (Continued on next page) Byte Description Byte Value Comments
    Protocol Discriminator 0x08 BRI
    CRV Length 0x01 or 0x02
    First CRV Byte 0x?
    Second CRV Byte0x?
    Message Type 0x62 FACility
    Locking Shift to Code Set 6 0x96
    Facility IE 0x1c
    Length of Facility IE 0x?? computed length
    Q.932 Supplementary Service 0x91
    component type tag 0xa1 INVOKE component
    component length 0x?? computed length
    component length0x?? long form (length > 127)
    invoke identifier tag 0x02
    invoke identifier length 0x01
    invoke identifier 0x?? even value
    operation value tag 0x02
    operation value length 0x01
    Operation Value = Event Report 0x95
    Q.931 IEs tag 0x40
    Q.931 IEs length 0x?? computed length
    Q.931 IEs length0x?? long form (length > 127)
    Cause IE0x08
    length of Cause IE0x02 computed length
    Ext bit | coding standard | 
    location0x81 or 0xe1 switch-to-adjunct
    Cause Value0x?? cause-dependent
    The Connected Number IE0x0c party dropped from call
    Length of IE 0x?
    Ext bit | Type | Numbering plan0x80
    * Address digits0x??, 0x30 thru 0x39, 0x23(#), 0x2a(*)
    Call Identity IE 0x10
    Length of Call Identity 0x02 computed value
    * Call identifier (2 bytes) 0x?? switch-assigned value
    User-User IE0x7e User-to-user information
    length of user-user0x?? computed length
    protocol discriminator0x??
    *user information0x?? 
    						
    							Byte Level Messages
    5-26Issue 6  June 1997 
    Disconnect/Drop Event Report — (continued)
    Byte Description Byte Value Comments
    Locking Shift to Code Set 6 0x96
    The Party Identifier IE 0x44
    Length of the IE  0x01 or 0x02
    Ext bit | Party ID 0x??
    Ext bit | Party ID (second byte)0x??
    The Specific Event IE 0x47
    The length of the Specific Event IE 0x01
    Event value = Drop  0x84 
    						