Home > Lucent Technologies > Communications System > Lucent Technologies DEFINITY Enterprise Communications Server Release 5, CallVisor, ASAI Protocol Reference Instructions Manual

Lucent Technologies DEFINITY Enterprise Communications Server Release 5, CallVisor, ASAI Protocol Reference Instructions Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 5, CallVisor, ASAI Protocol Reference Instructions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 600
    							Codeset 6 Information Elements
    Issue 6  June 1997
    4-35
    Data Item IE
    The Data Item IE shown in Figure 4-20 returns information that an adjunct has 
    queried for. The Data Item information element contains one information value. 
    The data item type identifies what value is present in the IE. Presently, the Data 
    Item IE is used in the response to the Integrated Directory Database query and in 
    the reporting of ISDN Charge Advice.
    Figure 4-20. Data Item Information Element
    Data Item Type (octet 3):
    This byte may need to be interpreted differently in future messages. Currently this 
    byte can take on the following values/meanings:ValueThis field is optional and represents the binary count associated 
    with the Counter Type. The ECS currently sends one- or two-byte 
    Value fields. Adjuncts should be prepared to receive two-byte 
    values. 
    NOTE:
    When a two-byte value is present, the high order bits are in 
    byte 4 and the low order bits are in byte 4a, just as they are 
    with two-byte CRVs. Refer to the 
    DEFINITY Enterprise 
    Communications Server Administration and Features 
    Description
    , 555-230-522, for specifics on the ECS running 
    ASAI to determine the maximum values for the parameters 
    encoded in the Value field. This indicates the maximum 
    number of bytes used to encode the information. This 
    number varies from ECS to ECS. Hosts should operate with 
    the maximum values for the largest ECS on which they will 
    be running.
    8  7654321
    Data Items
    0  1010010Octet 1
    Information element identifier
    Length of Data Items contents 2
    1
    Data Item Type 3
    Ext
    1
    Data Item Value            4*?
    Ext 
    						
    							Information Elements
    4-36Issue 6  June 1997 
     Data Item Value
     This value may be either an integer value, or an ASCII string. Charge amounts 
    are encoded as integers and names are encoded as ASCII strings.
    If an integer is encoded, then 7 bits of each octet are used. The high bit is an 
    extension bit, and is set to 0 except in the last octet of the value. The most 
    significant octets are ordered first. For example, 400 (decimal), which is 0x190 
    (hexadecimal) is encoded in two octets: 
    ASCII strings are encoded with the high bit set to 0 for every byte except the last 
    byte.Bits
    7654321
    0000000 Reserved
    0 0 0 0 0 0 1  Intermediate Charge
    0000010 Final Charge
    0000011 Split Charge
    0000100 Name
    0 
    EXT0000011 4a
    1 
    EXT0010000 4b 
    						
    							Codeset 6 Information Elements
    Issue 6  June 1997
    4-37
     Domain
    The Domain IE shown in Figure 4-21 specifies the domain for which an event is 
    reported.
    .
    Figure 4-21. Domain Information Element8  7654321
    Domain Information
    0  1001001Byte1
    Information element identifier
    Length of Domain Information contents 2
    1
    Domain Type 3
    Ext.
    0/1
    Address           4*
    Ext
    Domain TypeBits
    7 6 5 4 3 2 1
    0 0 0 0 0 0 0 Adjunct-Monitored call audit
    0 0 0 0 0 0 1 Group Extension (includes ACD split)
    0 0 0 0 0 1 1 Extension
    0 0 0 0 1 1 0 Work mode
    0 0 0 0 1 1 1 Talk state
    0 0 0 1 0 0 1 Trunk access code
    0 0 0 1 1 0 0 Vector Directory Number
    0 0 0 1 1 1 0 Announcement
    0 0 0 1 1 1 1 Data Extension
    0 0 1 0 0 0 0 ASAI
    0 0 1 0 0 0 1 Station Type
    0 0 1 0 0 1 0 Other
    0 0 1 0 0 1 1 Logical Agent
    0 0 1 0 1 0 1 Integrated Directory Database
    0 0 1 1 0 0 0 Reason Codes 
    						
    							Information Elements
    4-38Issue 6  June 1997 
    nIf the domain type is a group extension, an extension, logical 
    agent, trunk access code, VDN, announcement, or data 
    extension, the address field may contain the extension 
    number (in ASCII).
    1 In an incoming Domain IE the ECS will 
    parse, the only ASCII characters the ECS permits are the 
    digits 0 through 9.
    2 There may be instances of event reports 
    where an address should be included, but an address is not 
    available to the ECS. In such cases, the address is present 
    where ASAI requires it. However, in such a case, the 
    Address field contains default values:
    — ***** is the default value for a local ECS extension 
    (might be an “interphantom” extension);
    — ##### is the default value for an unknown external 
    number.
    Any adjunct interfacing to the ECS should be prepared to 
    receive the address with default values.
    nIf the domain type is “Work Mode,” the address field contains a 
    single-byte coded as follows:
    1. The address (extension number) is not present when the Domain IE is responding to the 
    extension information query, except for an extension information query containing a logical 
    extension of a logged-in agent. In this case, the address contains the physical extension 
    the agent is logged into. The address is present in all other cases.
    2. The 
    Adjunct/Switch Application Interface (ASAI) Specification also permits “*” and “#.”
    Address (byte 4, 
    bits 7 through 1)This optional field has a variable number of bytes 
    and its format depends on the domain type.
    Bits
    7 6 5 4 3 2 1
    0 0 0 0 0 0 0 Reserved
    0 0 0 0 0 0 1 Aux mode
    0 0 0 0 0 1 0 After Call Work Mode
    0 0 0 0 0 1 1 Auto In Mode
    0 0 0 0 1 0 0 Manual In Mode
    0 0 0 0 1 1 1 Logged in
    0 0 0 1 0 0 0 Not Logged in 
    						
    							Codeset 6 Information Elements
    Issue 6  June 1997
    4-39
    nIf the domain type is “Talk State,” the address field contains a single 
    byte coded as follows:
    nIf the domain type is “Station Type,” the address field contains a 
    single byte coded as follows:
    nIf the domain type is “ASAI,” the address field contains a single byte 
    coded as follows:
    nIf the Domain type is Reason Codes, the address field contains a 
    single byte with a binary value between 1-9.
    nFor other domain types, the address field is not used (call classifiers 
    cannot be addressed individually). Bits
    7 6 5 4 3 2 1
    0 0 0 0 0 0 0 Reserved
    0 0 0 0 1 0 1 On Call
    0 0 0 01 1 0 Available/Not on Call
    Bits
    7 6 5 4 3 2 1
    0 0 0 0 0 0 0 Reserved
    0 0 0 0 0 0 1 Analog
    0 0 0 0 0 1 0 Proprietary
    0 0 0 0 0 1 1 Basic Rate ISDN Interface
    Bits
    7 6 5 4 3 2 1
    0 0 0 0 0 0 0 Reserved
    0 0 0 0 0 0 1 No Bearer Channel Capabilities 
    						
    							Information Elements
    4-40Issue 6  June 1997 
    Facility Information Element (FIE)
    The Facility information element (FIE) identifies and contains an ASAI capability 
    request or response. CCITT Recommendation Q.932 uses an X.209 encoding of 
    X.229 Protocol Data Units.
    The FIE only appears once in a message. The maximum length of the BRI 
    message determines the number of bytes that the FIE may occupy; therefore, it 
    imposes an upper bound on the length of an IE.
    Table 4-6 to Table 4-9 show the FIE encoding.
    .
    NOTE:
    The FIE may contain only one component.
    Figure 4-22. Facility Information Element
    Service Discriminator
    The ECS/ASAI recognizes only one service discriminator, Q.932 Supplementary 
    Services, with the value shown: 1 0 0 0 1.
    Components (Bytes 4, etc.)
    A component is a sequence of data elements, each made up of a tag, a length, 
    and contents. The first byte of the FIE component (byte 4) gives the component 
    type. The component types for the Facility information element are:
    nInvoke
    nReturn Result
    nReturn Error
    nReject 8 7654321
    Facility
    0 0011100Byte1
    information element identifier
    Length of facility contents 2
    1
    Ext 0010001 3
    spare Service Discriminator
    Component (Note 1)      4 etc. 
    						
    							Codeset 6 Information Elements
    Issue 6  June 1997
    4-41
    t
    1. The component length is coded to indicate the number of bytes contained in the component (excluding
    the component type tag and the component length bytes).
    2. This ASAI implementation never uses or expects linked identifiers. Refer to the 
    Adjunct/Switch
    Application Interface (ASAI) Specification for a description.
    3. Contains capability parameter(s) for the Invoke component type.
    Table 4-6. Invoke Component
    Invoke component SectionMandatory
    IndicationByte 
    Group
    Component type tag
    Component length
    1Component Type Tag
    “Length of Each Component or Contents” Mandatory4
    5
    Invoke identifier tag
    Invoke identifier length
    Invoke identifierInvoke Identifier Tags
    “Length of Each Component or Contents”
    Invoke IdentifierMandatory6
    7
    8
    Linked identifier tag
    2 
    Linked identifier length
    Linked identifierNot used
    Not used
    Not usedOptional9
    10
    11
    Operation value tag
    Operation value length
    Operation ValueOperation Value Tag
    “Length of Each Component or Contents”
    Operation ValueMandatory12
    13
    14
    Argument
    3  Using Existing Q.931
    Information Elements as ParametersOptional 15, etc. 
    						
    							Information Elements
    4-42Issue 6  June 1997 
    1. The component length is coded to indicate the number of bytes contained in the component (excluding
    the component type tag and the component length bytes).
    2. The sequence tag is an anomaly in the Return Result component. Although other components are
    similarly structured, the Return Result component is the only component with a sequence tag. This
    arises from a specific backward compatibility need for the Q.932 Return Result component with respect
    to other CCITT standards.
    3. When the sequence tag is present, both the Operation Value and the Result must be present. All are
    present or none are.
    4. Contains parameter(s) of the Return Result component type.
    Table 4-7. Return Result Component
    Invoke component SectionMandatory
    IndicationByte 
    Group
    Component type tag
    Component length
    1 Component Type Tag
    “Length of Each Component or Contents” Mandatory4
    5
    Invoke identifier tag
    Invoke identifier length
    Invoke identifierInvoke Identifier Tags
    “Length of Each Component or Contents”
    Invoke IdentifierMandatory6
    7
    8
    Sequence tag
    2, 3
    Sequence lengthSequence Value Tag
    “Length of Each Component or Contents” Optional9
    10
    Operation value tag
    3
    Operation value length
    Operation ValueOperation Value Tag
    “Length of Each Component or Contents”
    Operation ValueMandatory11
    12
    13
    Result
    3, 4Using Existing Q.931
    Information Elements as ParametersOptional 14, etc. 
    						
    							Codeset 6 Information Elements
    Issue 6  June 1997
    4-43
    .
    1. The component length is coded to indicate the number of bytes contained in the component (excluding the
    component type tag and the component length bytes).
    2. The ASAI specification and the Q.932 specification have an “error value” here in the return error component.
    Both ASAI and Q.932 have the same encoding for the “error value tag” in the return error component and
    the “operation value tag” in the Invoke component. This means that what occupies the “error value” field is
    an Operation Value.
    3. Contains parameter(s) of the return error component type
    Table 4-8. Return Error Component
    Invoke Component SectionMandatory
    IndicationByte 
    Group
    Component type tag
    Component length
    1 Component Type Tag
    “Length of Each Component or Contents” Mandatory4
    5
    Invoke identifier tag
    Invoke identifier length
    Invoke identifierInvoke Identifier Tags
    “Length of Each Component or Contents”
    Invoke IdentifierMandatory6
    7
    8
    Error value tag
    Error value length
    Error value/Operation Value
    2
    Error Value Tag
    “Length of Each Component or Contents”
    Error ValueMandatory9
    10
    11
    Parameter
    3  Using Existing Q.931
    Information Elements as ParametersOptional 12, 
    etc. 
    						
    							Information Elements
    4-44Issue 6  June 1997 
    Component/Content Length
    Lengths up to 127 bytes are coded using the short form of Recommendation 
    X.209: bit 8 is set to zero and the remaining seven bits are a binary encoding of 
    the length with bit 1 the least significant bit.
    This length encoding is identical to that of Recommendation Q.931 for lengths up 
    to 127 bytes.
    .
    Figure 4-23. Format of the Length Field (Short Form)
    1. The component length is coded to indicate the number of bytes contained in the component (excluding
    the component type tag and the component length bytes).
    2. The problem length is always one byte.
    Table 4-9. Reject Component
    Reject Component SectionMandatory
    IndicationByte 
    Group
    Component type tag
    Component length
    1 Component Type Tag
    “Length of Each Component or Contents” Mandatory4
    5
    Invoke identifier tag
    Invoke identifier length
    Invoke identifierInvoke Identifier Tags
    “Length of Each Component or Contents”
    Invoke IdentifierMandatory6
    7
    8
    Problem tag
    Problem length
    2 
    ProblemProblem Tag
    “Length of Each Component or Contents”
    Problem TagMandatory6
    7
    8
    87654321
    0 Length of Contents
    MSB LSB 
    						
    All Lucent Technologies manuals Comments (0)