Home > Lucent Technologies > Communications System > Lucent Technologies DEFINITY Enterprise Communications Server Release 5, CallVisor, ASAI Protocol Reference Instructions Manual

Lucent Technologies DEFINITY Enterprise Communications Server Release 5, CallVisor, ASAI Protocol Reference Instructions Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 5, CallVisor, ASAI Protocol Reference Instructions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 600
    							Domain Control Capability Group
    Issue 6  June 1997
    5-77
    Third Party Auto Dial Request for an Extension
    (Continued on next page) Byte Description Byte Value Comments
    Protocol Discriminator 0x08 BRI
    CRV Length 0x01 or 0x02
    First CRV Byte 0x?
    Second CRV Byte0x?
    Message Type 0x62 FACility
    Locking Shift to Code Set 6 0x96
    Facility IE 0x1c
    Length of Facility IE 0x?? computed length
    Q.932 Supplementary Service 0x91
    component type tag 0xa1 INVOKE component
    component length 0x?? computed length
    component length0x?? long form (length > 127)
    invoke identifier tag 0x02
    invoke identifier length 0x01
    invoke identifier 0x??initiator — odd value
    operation value tag 0x02
    operation value length 0x01
    Operation Value = 3rd Party Auto 
    Dial0xc6
    Q.931 IEs tag 0x40
    Q.931 IEs length 0x?? computed length
    Q.931 IEs length0x?? long form (length > 127)
    Called Party Number IE 0x70
    Length of Called Party Number 0x? computed length
    Address Type & Numbering Plan 0x80 unknown numbering plan
    * ASCII Address digits 0x??  0x30 through 0x39, 0x23 (#), 
    0x2a (*)
    User-User IE0x7e User-to-user information
    length of user-user0x?? computed length
    protocol discriminator0x??
    *user information0x??
    Locking Shift to Code Set 6 0x96
    The Domain IE 0x49
    The length of the Domain IE 0x?
    The Domain type = Trunk Access 
    Code0x89 Trunk Access Code/ARS
    * The 1st to N-1 ASCII digits0x?? 0x30 through 0x39 
    						
    							Byte Level Messages
    5-78Issue 6  June 1997 
    NOTE:
    Use of the “return-ack” option is not recommended.Third Party Auto Dial Request for an Extension — (continued)
    Ext bit | last ASCII digit0x?? 0xb0 through 0xb9
    Call Options IE0x4b
    Length of Call Option IE0x01
    Option = priority call0x83
    Call Options IE0x4b
    Length of Call Option IE0x01
    Option = return ack flag0x8c 
    						
    							Domain Control Capability Group
    Issue 6  June 1997
    5-79
    Third Party (Domain) Relinquish 
    Control Request
    The adjunct invokes Relinquish control to terminate a Domain (Station/ACD Split) 
    Control Request.
    Byte Description Byte Value Comments
    Protocol Discriminator 0x08 BRI
    CRV Length 0x01 or 0x02
    First CRV Byte 0x?
    Second CRV Byte0x?
    Message Type 0x62 FACility
    Locking Shift to Code Set 6 0x96
    Facility IE 0x1c
    Length of Facility IE 0x?? computed length
    Q.932 Supplementary Service 0x91
    component type tag 0xa1 INVOKE component
    component length 0x?? computed length
    component length0x?? long form (length > 127)
    invoke identifier tag 0x02
    invoke identifier length 0x01
    invoke identifier 0x??initiator — odd value
    operation value tag 0x02
    operation value length 0x01
    Operation Value = Third Party Relinquish Control 0xb5 
    						
    							Byte Level Messages
    5-80Issue 6  June 1997 
    Third Party (Domain) Send DTMF
    Digits Request
    The adjunct invokes Send_DTMF_digits to request that DTMF tones be sent on a 
    call to selected parties.
    (Continued on next page) Byte Description Byte Value Comments
    Protocol Discriminator 0x08 BRI
    CRV Length 0x01 or 0x02
    First CRV Byte 0x?
    Second CRV Byte0x?
    Message Type 0x62 FACility
    Locking Shift to Code Set 6 0x96
    Facility IE 0x1c
    Length of Facility IE 0x?? computed length
    Q.932 Supplementary Service 0x91
    component type tag 0xa1 INVOKE component
    component length 0x?? computed length
    component length0x?? long form (length > 127)
    invoke identifier tag 0x02
    invoke identifier length 0x01
    invoke identifier 0x??initiator — odd value
    operation value tag 0x02
    operation value length 0x01
    Operation Value = Send DTMF Digits 0xc8
    Q.931 IEs tag 0x40
    Q.931 IEs length 0x?? computed length
    Q.931 IEs length0x?? long form (length> 127)
    Call Identity IE 0x10
    Length of Call Identity IE 0x02 computed value
    *Call identifier (2 octets) 0x?? switch-assigned value
    Locking Shift to Code Set 6 0x96
    *The Party Identifier IE0x44 Up to 5 receiving party
    IDs, all optional
    *Length of the IE0x01 or 0x02
    *Ext bit | Party ID0x??
    *Ext bit | Party ID (second octet)0x?? 
    						
    							Domain Control Capability Group
    Issue 6  June 1997
    5-81
    NOTE:
    The Party ID list can have up to five Party IDs.Third Party (Domain) Send DTMF Digits Request — (continued)
    Byte Description Byte Value Comments
    User Entered Code IE 0x02 User Entered Digit(s)
    Length of IE 0x?? calculated length
    Type 0x91 Customer-provided
    collected data indicator 0xc0 Already Collected
    * first n-1 digits 0x?? ACSII 0x30-0x39, 
    0x23(#), 0x2a(*)
    * last (nth) digit 0x?? ACSII 0xb0-0xb9, 
    0xa3(#), 0xaa(*)
    Call Options IE0x4b
    Length of Call Option IE0x02
    Option = tone duration0x8a
    Value = tone duration0x8X seconds = value * 0.01
    Call Options IE0x4b
    Length of Call Option IE0x02
    Option = pause duration0x8b
    Value = pause duration0x8X seconds = value * 0.01 
    						
    							Byte Level Messages
    5-82Issue 6  June 1997 
    Redirect Call (Domain)
    Byte Description Byte Value Comments
    Protocol Discriminator 0x08 BRI
    CRV Length 0x01 or 0x02
    First CRV Octet 0x?
    Second CRV Octet0x?
    Message Type 0x62 FACility
    Locking Shift to Code Set 6 0x96
    Facility IE 0x1c
    Length of Facility IE 0x?? computed length
    Q.932 Supplementary Service 0x91
    component type tag 0xa1 INVOKE component
    component length 0x?? computed length
    component length0x?? long form (length > 127)
    invoke identifier tag 0x02
    invoke identifier length 0x01
    invoke identifier 0x??initiator — odd value
    operation value tag 0x02
    operation value length 0x01
    Operation Value = Redirect Call 0xc9
    Q.931 IEs tag 0x40
    Q.931 IEs length 0x?? computed length
    Q.931 IEs length0x?? long form (length > 127)
    Call Identity IE 0x10
    Length of Call Identity IE 0x02 computed value
    * Call identifier (2 octets) 0x?? switch-assigned value
    Redirection Number IE 0x76
    Length of Redirection Number IE 0x? computed length
    Address Type & Numbering Plan 0x80 unknown numbering plan
    * ASCII address digits 0x??  0x30 through 0x39, 0x23 (#), 0x2a (*) 
    						
    							Domain Control Capability Group
    Issue 6  June 1997
    5-83
    Domain Control: FACility Messages Sent by the
    switch
    A FACility message is used to initiate an action within an existing association on 
    an active CRV. All FACility messages have the Protocol Discriminator and the 
    CRV followed by a FAC type = 0x62. 
    						
    							Byte Level Messages
    5-84Issue 6  June 1997 
    Acknowledgment of 
    Domain (Station) Control Request
    Byte Description Byte Value Comments
    Protocol Discriminator 0x08 BRI
    CRV Length 0x01 or 0x02
    First CRV Byte 0x?
    Second CRV Byte0x?
    Message Type 0x62 FACility
    Locking Shift to Code Set 6 0x96
    Facility IE 0x1c
    Length of Facility IE 0x?? computed length
    Q.932 Supplementary Service 0x91
    component type tag 0xa2 RETURN RESULT component
    component length 0x?? computed length
    component length0x?? long form (length > 127)
    invoke identifier tag 0x02
    invoke identifier length 0x01
    invoke identifier 0x?? value from request
    Sequence Tag0x30 Q.932 sequence tag
    Sequence Length0x?? computed length
    Sequence Length 0x?? long form (length > 127)
    operation value tag
    0x02
    operation value length0x01
    Operation Value = Domain Control0xc4
    Q.931 IEs tag0x40
    Q.931 IEs length0x??computed length
    Q.931 IEs length
    0x??long form (length > 127)
    * Call Identity IE
    0x10
    * Length of Call Identity0x02computed value
    * * Call identifier (2 bytes)
    0x??switch-assigned value
    Locking Shift to Code Set 6
    0x96
    * The Party Identifier IE0x44
    * Length of the IE 0x01 or 0x02
    * Ext bit | Party ID0x??
    * Ext bit | Party ID (second byte)0x??
    * The Specific Event IE 0x47
    * The length of the Specific Event IE 0x01
    * Event/Call State value  0x?? Call state (initiate, alert, held, 
    connected, other/unknown) 
    						
    							Domain Control Capability Group
    Issue 6  June 1997
    5-85
    NOTES:
    All bytes of this message from the sequence tag forward are present if, and only if, 
    there are calls at the domain-controlled station. The presence of such calls results in 
    parameters (call identity, party identity, and state) in this return result component. A 
    return result component only contains a sequence tag and operation value when 
    parameters are present.
    There is an association of the Nth call ID, party ID, and specific event. These IEs are 
    ordered accordingly. 
    						
    							Byte Level Messages
    5-86Issue 6  June 1997 
    Acknowledgment of 
    Third Party Auto Dial Request
    Byte Description Byte Value Comments
    Protocol Discriminator 0x08 BRI
    CRV Length 0x01 or 0x02
    First CRV Byte 0x?
    Second CRV Byte0x?
    Message Type 0x62 FACility
    Locking Shift to Code Set 6 0x96
    Facility IE 0x1c
    Length of Facility IE 0x?? computed length
    Q.932 Supplementary Service 0x91
    component type tag 0xa1 INVOKE component
    component length 0x?? computed length
    component length0x?? long form (length > 127)
    invoke identifier tag 0x02
    invoke identifier length 0x01
    invoke identifier 0x?? even value
    operation value tag 0x02
    operation value length 0x01
    Operation Value = Proceed 0xbd
    Q.931 IEs tag 0x40
    Q.931 IEs length 0x?? computed length
    Q.931 IEs length0x?? long form (length > 127)
    Call Identity IE 0x10
    Length of Call Identity 0x02 computed value
    * Call identifier (2 bytes) 0x?? switch-assigned value
    Locking Shift to Code Set 6 0x96
    The Party Identifier IE 0x44
    Length of the IE  0x01 or 0x02
    Ext bit | Party ID 0x??
    Ext bit | Party ID (second byte)0x?? 
    						
    All Lucent Technologies manuals Comments (0)

    Related Manuals for Lucent Technologies DEFINITY Enterprise Communications Server Release 5, CallVisor, ASAI Protocol Reference Instructions Manual