    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 5, CallVisor, ASAI Protocol Reference Instructions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 600
    							Event Reports
    Issue 6  June 1997
    5-7
    Answered Event Report — (continued)
    Byte Description Byte Value Comments
    Called Party Number IE 0x70
    Length of Called Party Number 0x? computed length
    Address Type & Numbering Plan 0x?? 0x80, 0x90, 0x81, 0x91, 0xa0, or 
    0xa1
    * Address digits 0x??  0x30 thru 0x39, 0x23(#), 0x2a(*)
    Locking Shift to Code Set 6 0x96
    The Party Identifier IE 0x44
    Length of the IE  0x01 or 0x02
    Ext bit | Party ID 0x?? 
    Ext bit | Party ID (second byte)0x??
    The Specific Event IE 0x47
    The length of the Specific Event IE 0x01
    Event value = Answered  0x96 
    						
    							Byte Level Messages
    5-8Issue 6  June 1997 
    Busy/Unavailable Event Report
    Byte Description Byte Value Comments
    Protocol Discriminator 0x08 BRI
    CRV Length 0x01 or 0x02
    First CRV Byte 0x?
    Second CRV Byte0x?
    Message Type 0x62 FACility
    Locking Shift to Code Set 6 0x96
    Facility IE 0x1c
    Length of Facility IE 0x?? computed length
    Q.932 Supplementary Service 0x91
    component type tag 0xa1 INVOKE component
    component length 0x?? computed length
    component length0x?? long form (length > 127)
    invoke identifier tag 0x02
    invoke identifier length 0x01
    invoke identifier 0x?? even value
    operation value tag 0x02
    operation value length 0x01
    Operation Value = Event Report 0x95
    Q.931 IEs tag 0x40
    Q.931 IEs length 0x?? computed length
    Q.931 IEs length0x?? long form (length > 127)
    Cause IE 0x08
    length of Cause IE 0x02 computed length
    Ext bit | coding standard | location 0x81 or 0xe1 switch-to-adjunct
    Cause Value 0x?? cause-dependent
    Call Identity IE 0x10
    Length of Call Identity 0x02 computed value
    * Call identifier (2 bytes) 0x?? switch-assigned value
    Called Party Number IE 0x70
    Length of Called Party Number 0x? computed length
    Address Type & Numbering Plan 0x?? 0x80, 0x90, 0x81, 0x91, 0xa0, 
    or 0xa1
    * Address digits 0x??  0x30 thru 0x39,0x23(#), 0x2a(*)
    Locking Shift to Code Set 6 0x96
    The Specific Event IE 0x47
    The length of the Specific Event IE 0x01
    Event value = Busy  0x88 
    						
    							Event Reports
    Issue 6  June 1997
    5-9
    Call Conferenced Event Report 
    (Continued on next page) Byte Description Byte Value Comments
    Protocol Discriminator 0x08 BRI
    CRV Length 0x01 or 0x02
    First CRV Byte 0x?
    Second CRV Byte0x?
    Message Type 0x62 FACility
    Locking Shift to Code Set 6 0x96
    Facility IE 0x1c
    Length of Facility IE 0x?? computed length
    Q.932 Supplementary Service 0x91
    component type tag 0xa1 INVOKE component
    component length 0x?? computed length
    component length0x?? long form (length > 127)
    invoke identifier tag 0x02
    invoke identifier length 0x01
    invoke identifier 0x?? even value
    operation value tag 0x02
    operation value length 0x01
    Operation Value = Event Report 0x95
    Q.931 IEs tag 0x40
    Q.931 IEs length 0x?? computed length
    Q.931 IEs length0x?? long form (length > 127)
    * The Connected Number IE 0x0c
    * Length of IE  0x?
    * Ext bit | Type | Numbering plan 0x80
    * * Address digits 0x??  0x30 thru 0x39, 0x23(#), 0x2a(*)
    Call Identity IE 0x10“other” call ID before conference
    Length of Call Identity 0x02 computed value
    * Call identifier (2 bytes) 0x?? switch-assigned value
    Call Identity IE 0x10 “resulting” call ID after conference
    Length of Call Identity 0x02 computed value
    * Call identifier (2 bytes) 0x?? switch-assigned value 
    						
    							Byte Level Messages
    5-10Issue 6  June 1997 
    NOTES:
    The Call Identity IE containing the “other” call ID before the conference operation 
    must precede the Call Identity IE that contains the “resulting” call ID after the 
    conference operation.
    There must be the same number of Party ID IEs, Old Party ID IEs, and Connected 
    Number IEs.
    The Nth Party ID IE and the Nth Old Party ID IE correspond to the Nth Connected 
    Number IE (and thereby associate an extension with that party).
    To preserve a 1:1 correspondence, if the type/address for a party is unknown, a 
    Connected Number IE is present for that party, but the length byte is coded as zero 
    (and no bytes follow).Call Conferenced Event Report — (continued)
    Byte Description Byte Value Comments
    Calling Party Number 0x6c
    Length of Calling Party IE 0x? computed length
    Address Type & numbering Plan Id 0x?? 0x80, 0x90, 0x81, 0x91, 0xa0, or 
    0xa1
    * Address digits 0x??  0x30 thru 0x39, 0x23(#), 0x2a(*)
    Called Party Number IE 0x70
    Length of Called Party Number 0x? computed length
    Address Type & Numbering Plan 0x?? 0x80, 0x90, 0x81, 0x91, 0xa0, or 
    0xa1
    * Address digits 0x??  0x30 thru 0x39, 0x23(#), 0x2a(*)
    Locking Shift to Code Set 6 0x96
    * Old Party Identifier IE 0x17 Up to six old party IDs
    * Length of the IE  0x02 or 0x03
    * From Call 0x?? 0x80 or 0xc0
    * Ext bit | Party ID 0x??
    * Ext bit | Party ID (second byte)0x??
    * The Party Identifier IE 0x44 Up to six party IDs
    * Length of the IE  0x01 or 0x02
    * Ext bit | Party ID 0x?? 
    * Ext bit | Party ID (second byte)0x??
    The Specific Event IE 0x47
    The length of the Specific Event IE 0x01
    Event value = Conferenced 0x95 
    						
    							Event Reports
    Issue 6  June 1997
    5-11
    Call Initiated Event Report
    Byte Description Byte Value Comments
    Protocol Discriminator 0x08 BRI
    CRV Length 0x01 or 0x02
    First CRV Byte 0x?
    Second CRV Byte0x?
    Message Type 0x62 FACility
    Locking Shift to Code Set 6 0x96
    Facility IE 0x1c
    Length of Facility IE 0x?? computed length
    Q.932 Supplementary Service 0x91
    component type tag 0xa1 INVOKE component
    component length 0x?? computed length
    component length0x?? long form (length > 127)
    invoke identifier tag 0x02
    invoke identifier length 0x01
    invoke identifier 0x?? even value
    operation value tag 0x02
    operation value length 0x01
    Operation Value = Event Report 0x95
    Q.931 IEs tag 0x40
    Q.931 IEs length 0x?? computed length
    Q.931 IEs length0x?? long form (length > 127)
    Call Identity IE 0x10
    Length of Call Identity 0x02 computed value
    * Call identifier (2 bytes) 0x?? switch-assigned value
    Locking Shift to Code Set 6 0x96
    The Party Identifier IE 0x44
    Length of the IE  0x01 or 0x02
    Ext bit | Party ID 0x?? 
    Ext bit | Party ID (second byte)0x??
    The Specific Event IE 0x47
    The length of the Specific Event IE 0x01
    Event value = Initiate  0x97 
    						
    							Byte Level Messages
    5-12Issue 6  June 1997 
    Call Offered to Domain Event Report
    (Continued on next page) Byte Description Byte Value Comments
    Protocol Discriminator 0x08 BRI
    CRV Length 0x01 or 0x02
    First CRV Byte 0x?
    Second CRV Byte0x?
    Message Type 0x62 FACility
    Locking Shift to Code Set 6 0x96
    Facility IE 0x1c
    Length of Facility IE 0x?? computed length
    Q.932 Supplementary Service 0x91
    component type tag 0xa1 INVOKE component
    component length 0x?? computed length
    component length0x?? long form (length > 127)
    invoke identifier tag 0x02
    invoke identifier length 0x01
    invoke identifier 0x?? even value
    operation value tag 0x02
    operation value length 0x01
    Operation Value = Event Report 0x95
    Q.931 IEs tag 0x40
    Q.931 IEs length 0x?? computed length
    Q.931 IEs length0x?? long form (length > 127)
    Call Identity IE 0x10
    Length of Call Identity 0x02 computed value
    * Call identifier (2 bytes) 0x?? switch-assigned value
    Calling Party Number0x6c
    Length of Calling Party IE0x? computed length
    Address Type & numbering Plan Id0x?? 0x80, 0x90, 0x81, 0x91, 0xa0, or 
    0xa1
    * Address digits0x??  0x30 thru 0x39, 0x23(#), 0x2a(*)
    Called Party Number IE 0x70
    Length of Called Party Number 0x? computed length
    Address Type & Numbering Plan 0x?? 0x80, 0x90, 0x81, 0x91, 0xa0, or 
    0xa1
    * Address digits 0x??  0x30 thru 0x39, 0x23(#), 0x2a(*) 
    						
    							Event Reports
    Issue 6  June 1997
    5-13
    Call Offered To Domain Event Report — (continued)
    Byte Description Byte Value Comments
    User-User IE 0x7e User-to-User information
    length of user-user
    0x?? computed length
    protocol discriminator0x??
    *user information0x??
    Locking Shift to Code Set 60x96
    Originating Line IE0x01
    Length of OLI0x?? computed length
    * II-Digits0x??
    User Code IE0x02 User Entered Data IE
    length of user data0x?? computed length
    type of user data0x85 Call Prompter Data
    collected data indicator0xc0
    * first n-1 user entered digits0x00 | 0x?? ASCII data
    last user entered digit0x80 | 0x?? ASCII data
    The Trunk Identification IE 0x0a
    The length of IE  0x? computed length
    Direction0x80 No Direction
    * Trunk Group Number0x?? binary coded
    * Trunk Group Member Number0x?? binary coded
    The Specific Event IE 0x47
    The length of the Specific Event IE 0x01
    Event value = Incoming Call  0x91
    The Feature IE 0x48
    The Length of the Feature IE 0x01
    Feature 0x86 Flexible Billing
    The Domain IE  0x49
    The length of the Domain IE  0x?
    The Domain type 0x8c or 0x81 VDN or split
    * first to N-1 digits 0x??  0x30 thru 0x39, 0x23(#), 0x2a(*)
    The last digit 0xYY, 0xb0 thru 0x69, 0x23(#), 0xaa(*)
    Lookahead Interflow IE0x7b PRI Interflow
    length of lookahead interflow0x?? computed length
    Ext bit | Priority Level & Type0x80 | 0x?? from PRI
    (Continued on next page) 
    						
    							Byte Level Messages
    5-14Issue 6  June 1997 
    NOTE:
    The Calling Number IE and the Trunk Identification IE are mutually exclusive. One or 
    the other is present.
    Ext bit | Time Stamp - hours0x80 | 0x?? from PRI
    Ext bit | Time Stamp - minutes0x80 | 0x?? from PRI
    Ext bit | Time Stamp - seconds0x80 | 0x?? from PRI
    *Ext bit | first n-1 ASCII characters 0x00 | 0x?? ASCII data from PRI
    Ext bit | last ASCII character0x80 | 0x?? ASCII data from PRI Call Offered To Domain Event Report — (continued) 
    						
    							Event Reports
    Issue 6  June 1997
    5-15
    Call Originated Event Report
    NOTE:
    Not supported in G3V4 or Release 5.
    (Continued on next page) Byte Description Byte Value Comments
    Protocol Discriminator 0x08 BRI
    CRV Length 0x01 or 0x02
    First CRV Octet 0x?
    Second CRV Octet0x?
    Message Type 0x62 FACility
    Locking Shift to Code Set 6 0x96
    Facility IE 0x1c
    Length of Facility IE 0x?? computed length
    Q.932 Supplementary Service 0x91
    component type tag 0xa1 INVOKE component
    component length 0x?? computed length
    component length0x?? long form (length > 127)
    invoke identifier tag 0x02
    invoke identifier length 0x01
    invoke identifier 0x?? even value
    operation value tag 0x02
    operation value length 0x01
    Operation Value = Event Report 0x95
    Q.931 IEs tag 0x40
    Q.931 IEs length 0x?? computed length
    Q.931 IEs length0x?? long form (length > 127)
    Cause IE0x08 NOTE 1
    length of Cause IE0x02 computed length
    Ext bit | coding standard | 
    location0x81 or 0xe1 switch-to-adjunct
    Cause Value0x?? cause-dependent
    The Connected Number IE0x0c The party extension
    Length of IE 0x?
    Ext bit | Type | Numbering plan0x?? 0x80
    * ASCII Address digits0x??  0x30 thru 0x39, 0x23 (#), 0x2a (*)
    Call Identity IE 0x10
    Length of Call Identity IE 0x02 computed value 
    						
    							Byte Level Messages
    5-16Issue 6  June 1997 
    NOTE:
    Not supported in G3V4 or Release 5.Call Originated Event Report — (continued)
    Byte Description Byte Value Comments
    * Call identifier (2 octets) 0x?? switch-assigned value
    Calling Party Number 0x6c
    Length of Calling Party IE 0x? computed length
    Address Type & Numbering Plan ID 0x?? 0x80, 0x90, 0x81, 0x91, 0xa0, 
    or 0xa1
    * ASCII Address digits 0x??  0x30 through 0x39, 0x23 (#), 
    0x2a (*)
    Called Party Number IE 0x70
    Length of Called Party Number 0x? computed length
    Address Type & Numbering Plan 0x?? 0x80, 0x90, 0x81, 0x91, 0xa0, 
    or 0xa1
    * ASCII Address digits 0x??  0x30 through 0x39, 0x23 (#), 
    0x2a (*)
    User-user IE0x7e NOTE 1
    length of user-user IE0x? computed length
    protocol discriminator0x??
    *user information0x??
    Locking Shift to Code Set 6 0x96
    The Party Identifier IE 0x44
    Length of the IE  0x01 or 0x02
    Ext bit | Party ID 0x??
    Ext bit | Party ID (second octet)0x??
    The Specific Event IE 0x47
    The length of the Specific Event IE 0x01
    Event value = Call Originated  0x9d 
    						
    All Lucent Technologies manuals Comments (0)