Home > Lucent Technologies > Communications System > Lucent Technologies DEFINITY Enterprise Communications Server Release 5, CallVisor, ASAI Protocol Reference Instructions Manual

Lucent Technologies DEFINITY Enterprise Communications Server Release 5, CallVisor, ASAI Protocol Reference Instructions Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 5, CallVisor, ASAI Protocol Reference Instructions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 600
    							Request Feature Capability Group
    Issue 6  June 1997
    5-127
    Cancel Send All Calls Feature Activation
    Byte Description Byte Value Comments
    Protocol Discriminator 0x08 BRI
    CRV Length 0x01 or 0x02
    First CRV Byte 0x? assigned value
    Second CRV Byte0x? assigned value
    Message Type 0x64 REGister
    Locking Shift to Code Set 6 0x96
    Facility IE 0x1c
    Length of Facility 0x?? computed length
    Q.932 Supplementary Service 0x91
    component type tag = invoke 0xa1 INVOKE component
    component length 0x?? computed length
    component length0x?? long form (length > 127)
    invoke identifier tag 0x02
    invoke identifier length 0x01
    invoke identifier 0x??initiating — odd value
    operation value tag 0x02
    operation value length 0x01
    Operation Value = Feature Request 0x8f
    Q.931 IEs tag 0x40
    Q.931 IEs length 0x?? computed length
    Q.931 IEs length0x?? long form (length > 127)
    Redirecting Number IE 0x74
    Length of Redirecting Number IE 0x? computed length
    Address Type & Numbering Plan 0x?? See Chapter 4
    * ASCII address digits 0x??,  0x30 through 0x39, 0x23 (#), 
    0x2a (*)
    Locking Shift to Code Set 6 0x96
    The Feature IE 0x48
    The length of the feature IE 0x01
    Feature = Cancel Send All Calls  0x8d 
    						
    							Byte Level Messages
    5-128Issue 6  June 1997 
    Call Forwarding Feature Activation
    Byte Description Byte Value Comments
    Protocol Discriminator 0x08 BRI
    CRV Length 0x01 or 0x02
    First CRV Byte 0x? assigned value
    Second CRV Byte0x? assigned value
    Message Type 0x64 REGister
    Locking Shift to Code Set 6 0x96
    Facility IE 0x1c
    Length of Facility 0x?? computed length
    Q.932 Supplementary Service 0x91
    component type tag = invoke 0xa1 INVOKE component
    component length 0x?? computed length
    component length0x?? long form (length > 127)
    invoke identifier tag 0x02
    invoke identifier length 0x01
    invoke identifier 0x??initiating — odd value
    operation value tag 0x02
    operation value length 0x01
    Operation Value = Feature Request 0x8f
    Q.931 IEs tag 0x40
    Q.931 IEs length 0x?? computed length
    Q.931 IEs length0x?? long form (length > 127)
    Redirecting Number IE 0x74
    Length of Redirecting Number IE 0x? computed length
    Address Type & Numbering Plan 0x?? See Chapter 4
    * ASCII address digits 0x??,  0x30 through 0x39, 0x23 (#), 
    0x2a (*)
    Redirection Number IE 0x76
    Length of Redirection Number IE 0x? computed length
    Address Type & Numbering Plan 0x?? See Chapter 4
    * ASCII address digits 0x??,  0x30 through 0x39, 0x23 (#), 
    0x2a (*)
    Locking Shift to Code Set 6 0x96
    The Feature IE 0x48
    The length of the feature IE 0x01
    Feature = Forward Calls  0x8a 
    						
    							Request Feature Capability Group
    Issue 6  June 1997
    5-129
    Cancel Call Forwarding Feature Activation
    Byte Description Byte Value Comments
    Protocol Discriminator 0x08 BRI
    CRV Length 0x01 or 0x02
    First CRV Byte 0x? assigned value
    Second CRV Byte0x? assigned value
    Message Type 0x64 REGister
    Locking Shift to Code Set 6 0x96
    Facility IE 0x1c
    Length of Facility 0x?? computed length
    Q.932 Supplementary Service 0x91
    component type tag = invoke 0xa1 INVOKE component
    component length 0x?? computed length
    component length0x?? long form (length > 127)
    invoke identifier tag 0x02
    invoke identifier length 0x01
    invoke identifier 0x??initiating — odd value
    operation value tag 0x02
    operation value length 0x01
    Operation Value = Feature Request 0x8f
    Q.931 IEs tag 0x40
    Q.931 IEs length 0x?? computed length
    Q.931 IEs length0x?? long form (length > 127)
    Redirecting Number IE 0x74
    Length of Redirecting Number IE 0x? computed length
    Address Type & Numbering Plan 0x?? See Chapter 4
    * ASCII address digits 0x??,  0x30 through 0x39, 0x23 (#), 
    0x2a (*)
    Locking Shift to Code Set 6 0x96
    The Feature IE 0x48
    The length of the feature IE 0x01
    Feature = Cancel Forwarding  0x8b 
    						
    							Byte Level Messages
    5-130Issue 6  June 1997 
    Request Feature: REGister Messages Sent by 
    switch
    None for this capability group.
    Request Feature: FACility Messages Sent by the
    Adjunct
    None for this capability group.
    Request Feature: FACility Messages Sent by 
    switch
    None for this capability group.
    Request Feature: RELease COMplete Messages
    Sent by the Adjunct
    A RELease COMplete message terminates an association on an existing CRV. All 
    RELease COMplete messages have the Protocol Discriminator and the CRV 
    followed by a REL COM type = 0x5a. 
    See “RELease COMplete Messages Sent by the switch and the Adjunct.”
    Request Feature: RELease COMplete Messages
    Sent by the switch
    A RELease COMplete message terminates an association on an existing CRV. All 
    RELease COMplete messages have the Protocol Discriminator and the CRV 
    followed by a REL COM type = 0x5a. 
    						
    							Request Feature Capability Group
    Issue 6  June 1997
    5-131
    Request is Denied — Association Terminated
    Byte Description Byte Value Comments
    Protocol Discriminator 0x08 BRI
    CRV Length 0x01 or 0x02
    First CRV Byte 0x?
    Second CRV Byte0x?
    Message Type 0x5a RELease COMplete
    Locking Shift to Code Set 6 0x96
    Facility IE 0x1c
    Length of Facility 0x?? computed length
    Q.932 Supplementary Service 0x91
    component type tag 0xa3 return error
    component length 0x?? computed length
    invoke identifier tag 0x02
    invoke identifier length 0x01
    invoke identifier 0x?? value from request
    error value tag 0x02
    error value length 0x01
    Operation Value 0x?? Operation Value of the denied 
    request
    Q.931 IEs tag 0x40
    Q.931 IEs length 0x?? computed length
    Q.931 IEs length0x?? long form (length > 127)
    Cause IE 0x08
    length of Cause IE 0x02 computed length
    Ext bit | coding standard | location 0x81 or 0xe1
    Cause Value 0x?? cause-dependent 
    						
    							Byte Level Messages
    5-132Issue 6  June 1997 
    Request Feature: Acknowledgment —
    Association Terminates
    The switch uses the following message to acknowledge Request Feature 
    requests.
    Request Feature: RELease COMplete Messages
    Sent by Both the switch and the Adjunct
    A RELease COMplete message terminates an association on an existing CRV. All 
    RELease COMplete messages have the Protocol Discriminator and the CRV 
    followed by a REL COM type = 0x5a. Byte Description Byte Value Comments
    Protocol Discriminator 0x08 BRI
    CRV Length 0x01 or 0x02
    First CRV Byte 0x?
    Second CRV Byte0x?
    Message Type 0x5a RELease COMplete
    Locking Shift to Code Set 6 0x96
    Facility IE 0x1c
    Length of Facility IE 0x?? computed length
    Q.932 Supplementary Service 0x91
    component type tag 0xa2 RETURN RESULT 
    component
    component length 0x?? computed length
    component length0x?? long form (length > 127)
    invoke identifier tag 0x02
    invoke identifier length 0x01
    invoke identifier 0x?? value from request 
    						
    							Request Feature Capability Group
    Issue 6  June 1997
    5-133
    Request Feature: Terminate ASAI Association
    With Normal Clearing
    Request Feature: A Message is Not Understood —
    Association Aborted
    Byte Description Byte Value Comments
    Protocol Discriminator 0x08 BRI
    CRV Length 0x01 or 0x02
    First CRV Byte 0x?
    Second CRV Byte0x?
    Message Type 0x5a RELease COMplete
    The Cause IE 0x08
    Length of IE  0x02
    Ext bit | coding standard | 
    location0x80 or 0x81
    Ext bit | Class | Value in Class 0x90 Normal Clearing
    Byte Description Byte Value Comments
    Protocol Discriminator 0x08 BRI
    CRV Length 0x01 or 0x02
    First CRV Byte 0x?
    Second CRV Byte0x?
    Message Type 0x5a RELease COMplete
    Cause IE 0x08
    length of Cause IE 0x02 computed length
    Ext bit | coding standard | 
    location0x80, 0x81, 
    0xe0, 0xe1
    Cause Value 0x?? cause-dependent 
    						
    							Byte Level Messages
    5-134Issue 6  June 1997 
    Request Feature: Endpoint Rejects an
    Invalid/Protocol Violation FIE — Terminates
    Association
    Byte Description Byte Value Comments
    Protocol Discriminator 0x08 BRI
    CRV Length 0x01 or 0x02
    First CRV Byte 0x?
    Second CRV Byte0x?
    Message Type 0x5a RELease COMplete
    Locking Shift to Code Set 6 0x96
    Facility IE 0x1c
    Length of Facility IE 0x?? computed length
    Q.932 Supplementary Service 0x91
    component type tag 0xa4 REJECT
    component length 0x?? computed length
    invoke identifier tag 0x02
    invoke identifier length 0x01 0x0 if null invoke-id
    invoke identifier0x?? active invoke-id; omitted 
    if null
    Problem tag 0x?? Problem-specific
    Problem length 0x01
    Problem 0x?? Problem-specific 
    						
    							Request Feature Capability Group
    Issue 6  June 1997
    5-135
    Request Feature: Endpoint Aborts an Association
    NOTE:
    The switch always supplies a cause value when it aborts an association; the adjunct 
    may optionally supply a cause value. Byte Description Byte Value Comments
    Protocol Discriminator 0x08 BRI
    CRV Length 0x01 or 0x02
    First CRV Byte 0x?
    Second CRV Byte0x?
    Message Type 0x5a RELease COMplete
    Locking Shift to Code Set 6 0x96
    Facility IE 0x1c
    Length of Facility IE 0x?? computed length
    Q.932 Supplementary Service 0x91
    component type tag 0xa1 INVOKE component
    component length 0x?? computed length
    component length0x?? long form (length > 127)
    invoke identifier tag 0x02
    invoke identifier length 0x01
    invoke identifier 0x??
    operation value tag 0x02
    operation value length 0x01
    Operation Value = Abort 0xbe
    Q.931 IEs tag 0x40
    Q.931 IEs length 0x?? computed length
    Q.931 IEs length0x?? long form (length > 127)
    The Cause IE0x08 NOTE 1
    Length of IE 0x02
    Ext bit | coding standard | 
    location0x?? cause- and 
    direction-specific
    Ext bit | Class | Value in Class0x?? cause-specific 
    						
    							Byte Level Messages
    5-136Issue 6  June 1997 
    Value Query Capability Group
    Value Query: REGister Messages Sent by the
    Adjunct
    The REGister message initiates an association on a CRV. All REGister messages 
    have the Protocol Discriminator and the CRV followed by a REG type = 0x6.
    ACD Split Status Query
    Byte Description Byte Value Comments
    Protocol Discriminator 0x08 BRI
    CRV Length 0x01 or 0x02
    First CRV Byte 0x? assigned value
    Second CRV Byte0x? assigned value
    Message Type 0x64 REGister
    Locking Shift to Code Set 6 0x96
    Facility IE 0x1c
    Length of Facility 0x?? computed length
    Q.932 Supplementary Service 0x91
    component type tag = invoke 0xa1 INVOKE component
    component length 0x?? computed length
    component length0x?? long form (length > 127)
    invoke identifier tag 0x02
    invoke identifier length 0x01
    invoke identifier 0x??initiating — odd value
    operation value tag 0x02
    operation value length 0x01
    Operation Value = Value 
    Query0x8c
    Q.931 IEs tag 0x40
    Q.931 IEs length 0x?? computed length
    Q.931 IEs length0x?? long form (length > 127)
    Locking Shift to Code Set 6 0x96
    The Domain IE  0x49
    The length of the Domain IE  0x?
    The Domain type = ACD Split 0x81 ACD split
    * The first to N-1 ASCII digits 0x?? 0x30 through 0x39
    Exit bit | last ASCII digit 0x?? 0xb0 through 0xb9 
    						