Home > Lucent Technologies > Communications System > Lucent Technologies DEFINITY Enterprise Communications Server Release 5, CallVisor, ASAI Protocol Reference Instructions Manual

Lucent Technologies DEFINITY Enterprise Communications Server Release 5, CallVisor, ASAI Protocol Reference Instructions Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 5, CallVisor, ASAI Protocol Reference Instructions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 600
    							Event Reports
    Issue 6  June 1997
    5-27
    Entered Digits Event Report
    Byte Description Byte Value Comments
    Protocol Discriminator 0x08 BRI
    CRV Length 0x01 or 0x02
    First CRV Octet 0x?
    Second CRV Octet0x?
    Message Type 0x62 FACility
    Locking Shift to Code Set 6 0x96
    Facility IE 0x1c
    Length of Facility IE 0x?? computed length
    Q.932 Supplementary Service 0x91
    component type tag 0xa1 INVOKE component
    component length 0x?? computed length
    component length0x?? long form (length > 127)
    invoke identifier tag 0x02
    invoke identifier length 0x01
    invoke identifier 0x?? even value
    operation value tag 0x02
    operation value length 0x01
    Operation Value = Event 
    Report0x95
    Q.931 IEs tag 0x40
    Q.931 IEs length 0x?? computed length
    Q.931 IEs length0x?? long form (length > 127)
    Call Identity IE 0x10
    Length of Call Identity 0x02 computed value
    * Call identifier (2 octets) 0x?? switch-assigned value
    Locking Shift to Code Set 6 0x96
    User Entered Code IE 0x02 User Entered Digit(s)
    Length of IE 0x?? computed value
    Type 0xa0 call prompter
    collected data indicator 0x110XXXXX Timeout 00000-11111
    * first n-1 digits 0x?? ACSII 0x30-0x39, 0x23(#), 0x2a(*)
    * last (nth) digit 0x?? ACSII 0xb0-0xb9, 0xa3(#), 0xaa(*)
    The Specific Event IE 0x47
    The length of the Specific 
    Event IE0x01
    Event value = Entered Digits  0x9c 
    						
    							Byte Level Messages
    5-28Issue 6  June 1997 
    Hold Event Report
    Byte Description Byte Value Comments
    Protocol Discriminator 0x08 BRI
    CRV Length 0x01 or 0x02
    First CRV Byte 0x?
    Second CRV Byte0x?
    Message Type 0x62 FACility
    Locking Shift to Code Set 6 0x96
    Facility IE 0x1c
    Length of Facility IE 0x?? computed length
    Q.932 Supplementary Service 0x91
    component type tag 0xa1 INVOKE component
    component length 0x?? computed length
    component length0x?? long form (length > 127)
    invoke identifier tag 0x02
    invoke identifier length 0x01
    invoke identifier 0x?? even value
    operation value tag 0x02
    operation value length 0x01
    Operation Value = Event Report 0x95
    Q.931 IEs tag 0x40
    Q.931 IEs length 0x?? computed length
    Q.931 IEs length0x?? long form (length > 127)
    The Connected Number IE 0x0c
    Length of IE  0x?
    Ext bit | Type | Numbering plan 0x80
    * Address digits 0x??, 0x30 thru 0x39, 0x23 (#), 0x2a (*)
    Call Identity IE 0x10
    Length of Call Identity 0x02 computed value
    * Call identifier (2 bytes) 0x?? switch-assigned value
    Locking Shift to Code Set 6 0x96
    The Party Identifier IE 0x44
    Length of the IE  0x01 or 0x02
    Ext bit | Party ID 0x??
    Ext bit | Party ID (second byte)0x??
    The Specific Event IE 0x47
    The length of the Specific Event IE 0x01
    Event value = Hold  0x86 
    						
    							Event Reports
    Issue 6  June 1997
    5-29
    Login Event Report — 
    Domain (ACD Split/Skill) Control Association
    (Continued on next page) Byte Description Byte Value Comments
    Protocol Discriminator 0x08 BRI
    CRV Length 0x01 or 0x02
    First CRV Octet 0x?
    Second CRV Octet0x?
    Message Type 0x62 FACility
    Locking Shift to Code Set 6 0x96
    Facility IE 0x1c
    Length of Facility IE 0x?? computed length
    Q.932 Supplementary Service 0x91
    component type tag 0xa1 INVOKE component
    component length 0x?? computed length
    component length0x?? long form (length > 127)
    invoke identifier tag 0x02
    invoke identifier length 0x01
    invoke identifier 0x?? even value
    operation value tag 0x02
    operation value length 0x01
    Operation Value = Event Report 0x95
    Q.931 IEs tag 0x40
    Q.931 IEs length 0x?? computed length
    Q.931 IEs length0x?? long form (length > 127)
    Locking Shift to Code Set 6 0x96
    The Specific Event IE 0x47
    The length of the Specific Event IE 0x01
    Event value = Login  0x8e
    The Domain IE 0x49
    The length of the Domain IE 0x02
    The Domain type = Work Mode 0x86
    The Work Mode 0x?? 0x81, 08x2, 0x83, or 0x84 
    						
    							Byte Level Messages
    5-30Issue 6  June 1997 
    NOTE:
    The last Domain IE listed (Logical Extension) is present only if Expert Agent Selection 
    is used.Login Event Report — Domain (ACD Split/Skill) Control Association
    (continued)
    Byte DescriptionByte 
    Value Comments
    The Domain IE 0x49 Physical Extension
    The length of the Domain IE  0x?
    The Domain type = Extension 0x83
    * The 1st to N-1 ASCII digits 0x?? 0x30 through 0x39
    Ext bit | last ASCII digit  0x?? 0xb0 through 0xb9
    The Domain IE 0x49
    The length of the Domain IE 0x?
    The Domain type=logical agent0x93 Logical Extension
    * first to N-1 digits0x??, ACSII 0x30-0x39, 0x23(#), 0x2a(*)
    The last digit0x??, ACSII 0xb0-0xb9, 0xa3(#), 0xaa(*) 
    						
    							Event Reports
    Issue 6  June 1997
    5-31
    Logout Event Report —
    Domain (ACD Split/Skill) Control Association
    (Continued on next page) Byte Description Byte Value Comments
    Protocol Discriminator 0x08 BRI
    CRV Length 0x01 or 0x02
    First CRV Byte 0x?
    Second CRV Byte0x?
    Message Type 0x62 FACility
    Locking Shift to Code Set 6 0x96
    Facility IE 0x1c
    Length of Facility IE 0x?? computed length
    Q.932 Supplementary Service 0x91
    component type tag 0xa1 INVOKE component
    component length 0x?? computed length
    component length0x?? long form (length > 127)
    invoke identifier tag 0x02
    invoke identifier length 0x01
    invoke identifier 0x?? even value
    operation value tag 0x02
    operation value length 0x01
    Operation Value = Event Report 0x95
    Q.931 IEs tag 0x40
    Q.931 IEs length 0x?? computed length
    Q.931 IEs length0x?? long form (length > 127)
    Locking Shift to Code Set 6 0x96
    The Specific Event IE 0x47
    The length of the Specific Event IE 0x01
    Event value = Logout  0x8f
    The Domain IE 0x49 Physical Extension
    The length of the Domain IE  0x?
    The Domain type = Extension 0x83
    * The first to N-1 extension digits 0x?? 0x30 thru 0x39
    The last extension digit  0x?? 0xb0 thru 0xb9 
    						
    							Byte Level Messages
    5-32Issue 6  June 1997 
     
    1.The Domain IE listed for Logical Extension is present only if Expert Agent Selection
    is used.
    2.The reason codes Domain IE is present only if the System-Parameter Features field,
    Logout Reason Codes, is “forced” or “requested” and the agent logs out with a valid
    reason code (1-9).Logout Event Report — Domain (ACD Split/Skill) Control Association
    (continued)
    Byte Description Byte Value Comments
    The Domain IE0x49 Logical Extension
    Note1
    The length of the Domain IE 0x?
    The Domain type = Logical Agent0x93
    * The first to N-1 extension digits 0x?? 0x30 thru 0x39
    The last extension digit  0x?? 0xb0 thru 0xb9
    The Domain IE 0x49 The Reason Code
    Length of Domain IE 0x? Computed length
    Domain type=Reason code 0x98 Reason Code
    Note2
    Reason Code 0x8X 0x81 - 0x89 
    (Reason code 1-9) 
    						
    							Event Reports
    Issue 6  June 1997
    5-33
    Queued Event Report
    (Continued on next page) Byte Description Byte Value Comments
    Protocol Discriminator 0x08 BRI
    CRV Length 0x01 or 0x02
    First CRV Byte 0x?
    Second CRV Byte0x?
    Message Type 0x62 FACility
    Locking Shift to Code Set 6 0x96
    Facility IE 0x1c
    Length of Facility IE 0x?? computed length
    Q.932 Supplementary Service 0x91
    component type tag 0xa1 INVOKE component
    component length 0x?? computed length
    component length0x?? long form (length > 127)
    invoke identifier tag 0x02
    invoke identifier length 0x01
    invoke identifier 0x?? even value
    operation value tag 0x02
    operation value length 0x01
    Operation Value = Event Report 0x95
    Q.931 IEs tag 0x40
    Q.931 IEs length 0x?? computed length
    Q.931 IEs length0x?? long form (length > 127)
    Call Identity IE 0x10
    Length of Call Identity 0x02 computed value
    * Call identifier (2 bytes) 0x?? switch-assigned value
    Called Party Number IE 0x70
    Length of Called Party Number 0x? computed length
    Address Type & Numbering Plan 0x?? 0x80, 0x90, 0x81, 0x91, 0xa0, or 
    0xa1
    * Address digits 0x??, 0x30 thru 0x39, 0x23 (#), 0x2a (*)
    Locking Shift to Code Set 6 0x96
    The Counter IE  0x46
    Length of IE  0x02 or 0x03 Counter IE length
    Type = Number of Calls in Queue 0x83
    * Value < 127 (NOTE 1) 0x?? XX = 0x80 | # of queued calls 
    						
    							Byte Level Messages
    5-34Issue 6  June 1997 
    NOTE:
    The value takes up two bytes if the value is greater than 127. The high order bits are 
    first followed by 0x80 | low order bits.Queued Event Report — (continued)
    Byte Description Byte Value Comments
    The Specific Event IE 0x47
    The length of the Specific Event IE 0x01
    Event value = Queued  0x87
    The Domain IE  0x49
    The length of the Domain IE  0x?
    The Domain type = ACD Split 0x81 ACD split
    * The first to N-1 extension digits 0x?? 0x30 thru 0x39
    The last extension digit 0x?? 0xb0 thru 0xb9 
    						
    							Event Reports
    Issue 6  June 1997
    5-35
    Reconnected Event Report
    Byte Description Byte Value Comments
    Protocol Discriminator 0x08 BRI
    CRV Length 0x01 or 0x02
    First CRV Byte 0x?
    Second CRV Byte0x?
    Message Type 0x62 FACility
    Locking Shift to Code Set 6 0x96
    Facility IE 0x1c
    Length of Facility IE 0x?? computed length
    Q.932 Supplementary Service 0x91
    component type tag 0xa1 INVOKE component
    component length 0x?? computed length
    component length0x?? long form (length > 127)
    invoke identifier tag 0x02
    invoke identifier length 0x01
    invoke identifier 0x?? even value
    operation value tag 0x02
    operation value length 0x01
    Operation Value = Event Report 0x95
    Q.931 IEs tag 0x40
    Q.931 IEs length 0x?? computed length
    Q.931 IEs length0x?? long form (length > 127)
    The Connected Number IE 0x0c
    Length of IE  0x?
    Ext bit | Type | Numbering plan 0x80
    * Address digits 0x??,  0x30 thru 0x39, 0x23 (#), 0x2a (*)
    Call Identity IE 0x10
    Length of Call Identity 0x02 computed value
    * Call identifier (2 bytes) 0x?? switch-assigned value
    Locking Shift to Code Set 6 0x96
    The Party Identifier IE 0x44
    Length of the IE  0x01 or 0x02
    Ext bit | Party ID 0x??
    Ext bit | Party ID (second byte)0x??
    The Specific Event IE 0x47
    The length of the Specific Event IE 0x01
    Event value = Reconnect  0x98 
    						
    							Byte Level Messages
    5-36Issue 6  June 1997 
    Reorder/Denial Event Report
    Byte Description Byte Value Comments
    Protocol Discriminator 0x08 BRI
    CRV Length 0x01 or 0x02
    First CRV Byte 0x?
    Second CRV Byte0x?
    Message Type 0x62 FACility
    Locking Shift to Code Set 6 0x96
    Facility IE 0x1c
    Length of Facility IE 0x?? computed length
    Q.932 Supplementary Service 0x91
    component type tag 0xa1 INVOKE component
    component length 0x?? computed length
    component length0x?? long form (length > 127)
    invoke identifier tag 0x02
    invoke identifier length 0x01
    invoke identifier 0x?? even value
    operation value tag 0x02
    operation value length 0x01
    Operation Value = Event Report 0x95
    Q.931 IEs tag 0x40
    Q.931 IEs length 0x?? computed length
    Q.931 IEs length0x?? long form (length > 127)
    Cause IE 0x08
    length of Cause IE 0x02 computed length
    Ext bit | coding standard | location 0x81 or 0xe1 switch-to-adjunct
    Cause Value 0x?? cause-dependent
    Call Identity IE 0x10
    Length of Call Identity 0x02 computed value
    * Call identifier (2 bytes) 0x?? switch-assigned value
    Called Party Number IE 0x70
    Length of Called Party Number 0x? computed length
    Address Type & Numbering Plan 0x?? 0x80, 0x90, 0x81, 0x91, 0xa0, or 
    0xa1
    * Address digits 0x?? 0x30 thru 0x39, 0x23 (#), 0x2a (*)
    Locking Shift to Code Set 6 0x96
    The Specific Event IE 0x47
    The length of the Specific Event IE 0x01
    Event value = Denial 0x8c 
    						
    All Lucent Technologies manuals Comments (0)

    Related Manuals for Lucent Technologies DEFINITY Enterprise Communications Server Release 5, CallVisor, ASAI Protocol Reference Instructions Manual