    Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 5, CallVisor, ASAI Protocol Reference Instructions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 600
    							Call Control Capability Group
    Issue 6  June 1997
    5-47
    Third Party Reconnect Request
    Byte Description Byte Value Comments
    Protocol Discriminator 0x08 BRI
    CRV Length 0x01 or 0x02
    First CRV Byte 0x?
    Second CRV Byte0x?
    Message Type 0x62 FACility
    Locking Shift to Code Set 6 0x96
    Facility IE 0x1c
    Length of Facility IE 0x?? computed length
    Q.932 Supplementary Service 0x91
    component type tag 0xa1 INVOKE component
    component length 0x?? computed length
    component length0x?? long form (length > 127)
    invoke identifier tag 0x02
    invoke identifier length 0x01
    invoke identifier 0x??initiator — odd value
    operation value tag 0x02
    operation value length 0x01
    Operation Value = 3rd Party Reconnect 0x86
    Q.931 IEs tag 0x40
    Q.931 IEs length 0x?? computed length
    Q.931 IEs length0x?? long form (length > 127)
    Locking Shift to Code Set 6 0x96
    The Party Identifier IE 0x44
    Length of the IE  0x01 or 0x02
    Ext bit | Party ID 0x??
    Ext bit | Party ID (second byte) 0x?? 
    						
    							Byte Level Messages
    5-48Issue 6  June 1997 
    Third Party Merge Request
    Byte Description Byte Value Comments
    Protocol Discriminator 0x08 BRI
    CRV Length 0x01 or 0x02
    First CRV Byte 0x?
    Second CRV Byte0x?
    Message Type 0x62 FACility
    Locking Shift to Code Set 6 0x96
    Facility IE 0x1c
    Length of Facility IE 0x?? computed length
    Q.932 Supplementary Service 0x91
    component type tag 0xa1 INVOKE component
    component length 0x?? computed length
    component length0x?? long form (length > 127)
    invoke identifier tag 0x02
    invoke identifier length 0x01
    invoke identifier 0x??initiator — odd value
    operation value tag 0x02
    operation value length 0x01
    Operation Value = 3rd Party Merge 0x89
    Q.931 IEs tag 0x40
    Q.931 IEs length 0x?? computed length
    Q.931 IEs length0x?? long form (length > 127)
    Call Identity IE 0x10 active call
    Length of Call Identity 0x02 computed value
    * Call identifier (2 bytes) 0x?? switch-assigned value
    Locking Shift to Code Set 6 0x96
    The Party Identifier IE 0x44 party common to both calls
    Length of the IE  0x01 or 0x02
    Ext bit | Party ID 0x??
    Ext bit | Party ID (second byte) 0x??
    Conference/Transfer IE 0x4a
    Length of the IE 0x01
    Conference/Transfer Option 0x?? 0x81=conference, 0x82=transfer 
    						
    							Call Control Capability Group
    Issue 6  June 1997
    5-49
    Third Party Relinquish Control Request
    The adjunct invokes Relinquish_control to terminate a call control association.
    Byte Description Byte Value Comments
    Protocol Discriminator 0x08 BRI
    CRV Length 0x01 or 0x02
    First CRV Byte 0x?
    Second CRV Byte0x?
    Message Type 0x62 FACility
    Locking Shift to Code Set 6 0x96
    Facility IE 0x1c
    Length of Facility IE 0x?? computed length
    Q.932 Supplementary Service 0x91
    component type tag 0xa1 INVOKE component
    component length 0x?? computed length
    component length0x?? long form (length > 127)
    invoke identifier tag 0x02
    invoke identifier length 0x01
    invoke identifier 0x??initiator — odd value
    operation value tag 0x02
    operation value length 0x01
    Operation Value = Third Party Relinquish Control 0xb5 
    						
    							Byte Level Messages
    5-50Issue 6  June 1997 
    Third Party Listen Disconnect Request
    Byte Description Byte Value Comments
    Protocol Discriminator 0x08 BRI
    CRV Length 0x01 or 0x02
    First CRV Byte 0x?
    Second CRV Byte0x?
    Message Type 0x62 FACility
    Locking Shift to Code Set 6 0x96
    Facility IE 0x1c
    Length of Facility IE 0x?? computed length
    Q.932 Supplementary Service 0x91
    component type tag 0xa1 INVOKE component
    component length 0x?? computed length
    component length0x?? long form (length > 127)
    invoke identifier tag 0x02
    invoke identifier length 0x01
    invoke identifier 0x??initiator — odd value
    operation value tag 0x02
    operation value length 0x01
    Operation Value = Selective 
    Disconnect0xca selective disconnect of 
    listening path
    Q.931 IEs tag 0x40
    Q.931 IEs length 0x?? computed length
    Q.931.IEs length0x?? long form (length > 127)
    Locking Shift to Code Set 6 0x96
    The Party Identifier IE 0x44
    The Listener
    Length of the IE  0x01 or 0x02
    Ext bit | Party ID 0x?? 
    *Ext bit | Party ID
    (second octet)0x??
    *The Party Identifier ID  0x44 The Talker
    *Length of IE 0x01 or 0x02
    *Ext bit | Party ID 0x??
    *Ext bit | Party ID 
    (second octet)0x?? 
    						
    							Call Control Capability Group
    Issue 6  June 1997
    5-51
    Third Party Listen Reconnect Request
    Byte Description Byte Value Comments
    Protocol Discriminator 0x08 BRI
    CRV Length 0x01 or 0x02
    First CRV Byte 0x?
    Second CRV Byte0x?
    Message Type 0x62 FACility
    Locking Shift to Code Set 6 0x96
    Facility IE 0x1c
    Length of Facility IE 0x?? computed length
    Q.932 Supplementary Service 0x91
    component type tag 0xa1 INVOKE component
    component length 0x?? computed length
    component length0x?? long form (length > 127)
    invoke identifier tag 0x02
    invoke identifier length 0x01
    invoke identifier 0x??initiator — odd value
    operation value tag 0x02
    operation value length 0x01
    Operation Value = Selective 
    Reconnect0xcb selective reconnect of 
    listening path
    Q.931 IEs tag 0x40
    Q.931 IEs length 0x?? computed length
    Q.931.IEs length0x?? long form (length > 127)
    Locking Shift to Code Set 6 0x96
    The Party Identifier IE 0x44
    The Listener
    Length of the IE  0x01 or 0x02
    Ext bit | Party ID 0x?? 
    *Ext bit | Party ID
    (second octet)0x??
    *The Party Identifier ID  0x44 The Talker
    *Length of IE 0x01 or 0x02
    *Ext bit | Party ID 0x??
    *Ext bit | Party ID 
    second octet)0x?? 
    						
    							Byte Level Messages
    5-52Issue 6  June 1997 
    Third Party Send DTMF Digits Request
    The adjunct invokes Send_DTMF_digits to request that DTMF tones be sent on a 
    call to selected parties.
    (Continued on next page) Byte Description Byte Value Comments
    Protocol Discriminator 0x08 BRI
    CRV Length 0x01 or 0x02
    First CRV Byte 0x?
    Second CRV Byte0x?
    Message Type 0x62 FACility
    Locking Shift to Code Set 6 0x96
    Facility IE 0x1c
    Length of Facility IE 0x?? computed length
    Q.932 Supplementary Service 0x91
    component type tag 0xa1 INVOKE component
    component length 0x?? computed length
    component length0x?? long form (length > 127)
    invoke identifier tag 0x02
    invoke identifier length 0x01
    invoke identifier 0x??initiator — odd value
    operation value tag 0x02
    operation value length 0x01
    Operation Value = Send DTMF Digits 0xc8
    Q.931 IEs tag 0x40
    Q.931 IEs length 0x?? computed length
    Q.931 IEs length0x?? long form (length> 127)
    Locking Shift to Code Set 6  0x96
    User Entered Code IE 0x02 User Entered Digit(s)
    Length of IE 0x?? calculated length
    Type 0x91 Customer-provided
    collected data indicator 0xc0 Already Collected
    * first n-1 digits 0x?? ACSII 0x30-0x39, 0x23(#), 0x2a(*)
    * last (nth) digit 0x?? ACSII 0xb0-0xb9, 0xa3(#), 0xaa(*)
    *The Party Identifier IE 0x44
    *Length of the IE 0x01 or 0x02
    *Ext bit | Party ID 0x??
    *Ext bit | Party ID (second octet) 0x?? 
    						
    							Call Control Capability Group
    Issue 6  June 1997
    5-53
    NOTE:
    The first Party ID on the list is the tone “sender.” The Party ID list may optionally contain 
    up to five additional members (who will hear the tones) on a Call Control Association 
    Send DTMF request.Third Party Send DTMF Digits Request — (continued)
    Byte Description Byte Value Comments
    Call Options IE0x4b
    Length of Call Option IE0x02
    Option = tone duration0x8a
    Value = tone duration0x8X seconds = value * 0.01
    Call Options IE0x4b
    Length of Call Option IE0x02
    Option = pause duration0x8b
    Value = pause duration0x8X seconds = value * 0.01 
    						
    							Byte Level Messages
    5-54Issue 6  June 1997 
    Redirect Call
    Byte Description Byte Value Comments
    Protocol Discriminator 0x08 BRI
    CRV Length 0x01 or 0x02
    First CRV Octet 0x?
    Second CRV Octet0x?
    Message Type 0x62 FACility
    Locking Shift to Code Set 6 0x96
    Facility IE 0x1c
    Length of Facility IE 0x?? computed length
    Q.932 Supplementary Service 0x91
    component type tag 0xa1 INVOKE component
    component length 0x?? computed length
    component length0x?? long form (length > 127)
    invoke identifier tag 0x02
    invoke identifier length 0x01
    invoke identifier 0x??initiator — odd value
    operation value tag 0x02
    operation value length 0x01
    Operation Value = Redirect Call 0xc9
    Q.931 IEs tag 0x40
    Q.931 IEs length 0x?? computed length
    Q.931 IEs length0x?? long form (length > 127)
    Redirection Number IE 0x76
    Length of Redirection Number IE 0x? computed length
    Address Type & Numbering Plan 0x?? See Chapter 4
    * ASCII address digits 0x??,  0x30 through 0x39, 0x23 (#), 0x2a (*)
    Locking Shift to Code Set 60x96
    Party Identifier IE0x44
    Length of the IE0x?? computed value
    Ext Bit|Party ID0x??
    Ext Bit|Party ID (second octet)0x?? 
    						
    							Call Control Capability Group
    Issue 6  June 1997
    5-55
    Call Control: FACility Messages Sent by the 
    switch
    A FACility message is used to initiate an action within an existing association on 
    an active CRV. All FACility messages have the Protocol Discriminator and the 
    CRV followed by a FAC type = 0x62.
    Acknowledgment of Third Party 
    Make Call Request
    (Continued on next page)
    1. The Connected Number IE is only sent in Third Party Make Call ACKnowledgements for EAS. It
    is not sent for non-EAS (physical extensions).
    Byte Description Byte Value Comments
    Protocol Discriminator 0x08 BRI
    CRV Length 0x01 or 0x02
    First CRV Byte 0x?
    Second CRV Byte0x?
    Message Type 0x62 FACility
    Locking Shift to Code Set 6 0x96
    Facility IE 0x1c
    Length of Facility IE 0x?? computed length
    Q.932 Supplementary Service 0x91
    component type tag 0xa1 INVOKE component
    component length 0x?? computed length
    component length0x?? long form (length > 127)
    invoke identifier tag 0x02
    invoke identifier length 0x01
    invoke identifier 0x?? even value
    operation value tag 0x02
    operation value length 0x01
    Operation Value = Proceed 0xbd
    Q.931 IEs tag 0x40
    Q.931 IEs length 0x?? computed length
    Q.931 IEs length0x?? long form (length > 127)
    Connected Number IE10x0c
    Length of IE0x?
    Ext bit | type | Numbering Plan0x?? 0x80 or 0x90
    * 
    ASCII Address digits0x?? 0x30 through 0x39,0x23(#),0x2a(*)
    Call identity IE0x10 
    						
    							Byte Level Messages
    5-56Issue 6  June 1997 
    Acknowledgment of Third Party Make Call Request — (continued)
    Byte Description Byte Value Comments
    Length of Call identity 0x02 computed value
    * Call identifier (2 bytes) 0x?? switch-assigned value
    Locking Shift to Code Set 6 0x96
    The Party Identifier IE 0x44
    Length of the IE  0x01 or 0x02
    Ext bit | Party ID 0x??
    Ext bit | Party ID (second byte)0x?? 
    						