Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 5, CallVisor, ASAI Protocol Reference Instructions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Event Reports Issue 6 June 1997 5-37 Trunk Seized Event Report Byte Description Byte Value Comments Protocol Discriminator 0x08 BRI CRV Length 0x01 or 0x02 First CRV Byte 0x? Second CRV Byte0x? Message Type 0x62 FACility Locking Shift to Code Set 6 0x96 Facility IE 0x1c Length of Facility IE 0x?? computed length Q.932 Supplementary Service 0x91 component type tag 0xa1 INVOKE component component length 0x?? computed length component length0x?? long form (length > 127) invoke identifier tag 0x02 invoke identifier length 0x01 invoke identifier 0x?? even value operation value tag 0x02 operation value length 0x01 Operation Value = Event Report 0x95 Q.931 IEs tag 0x40 Q.931 IEs length 0x?? computed length Q.931 IEs length0x?? long form (length > 127) Call Identity IE 0x10 Length of Call Identity 0x02 computed value * Call identifier (2 bytes) 0x?? switch-assigned value Called Party Number IE 0x70 Length of Called Party Number 0x? computed length Address Type & Numbering Plan 0x?? 0x80, 0x90, 0x81, 0x91, 0xa0, or 0xa1 * Address digits 0x??, 0x30 thru 0x39, 0x23 (#), 0x2a (*) Locking Shift to Code Set 6 0x96 The Party Identifier IE 0x44 Length of the IE 0x01 or 0x02 Ext bit | Party ID 0x?? Ext bit | Party ID (second byte)0x?? The Specific Event IE 0x47 The length of the Specific Event IE 0x01 Event value = Seized 0x92
Byte Level Messages 5-38Issue 6 June 1997 Call Control Capability Group Call Control: REGister Messages Sent by the Adjunct A REGister message initiates an association on a CRV. All REGister messages have the Protocol Discriminator and the CRV followed by a REG type = 0x64.
Call Control Capability Group Issue 6 June 1997 5-39 Third Party Make Call Request (Continued on next page) Byte Description Byte Value Comments Protocol Discriminator 0x08 BRI CRV Length 0x01 or 0x02 First CRV Byte 0x? assigned value Second CRV Byte0x? assigned value Message Type 0x64 REGister Locking Shift to Code Set 6 0x96 Facility IE 0x1c Length of Facility 0x?? computed length Q.932 Supplementary Service 0x91 component type tag = invoke 0xa1 INVOKE component component length 0x?? computed length component length0x?? long form (length > 127) invoke identifier tag 0x02 invoke identifier length 0x01 invoke identifier 0x??initiating — odd value operation value tag 0x02 operation value length 0x01 Operation Value = 3rd Party Make Call 0x83 Q.931 IEs tag 0x40 Q.931 IEs length 0x?? computed length Q.931 IEs length0x?? long form (length > 127) Calling Party Number 0x6c Length of Calling Party IE 0x? computed length Address Type & numbering Plan Id 0x?? See Chapter 4 * ASCII Address digits 0xfs, 0x30 through 0x39, 0x23 (#), 0x2a (*) Called Party Number IE 0x70 Length of Called Party Number 0x? computed length Address Type & Numbering Plan 0x?? See Chapter 4 * ASCII Address digits 0x??, 0x30 through 0x39, 0x23 (#), 0x2a (*) User-User IE0x7e User-to-user information length of user-user0x?? computed length protocol discriminator0x?? *user information0x?? Locking Shift to Code Set 6 0x96 The Domain IE 0x49 The length of the Domain IE 0x? The Domain type = Trunk Access Code0x89 Trunk Access Code/ARS
Byte Level Messages 5-40Issue 6 June 1997 Third Party Make Call Request — (continued) Byte Description Byte Value Comments * The 1st to N-1 ASCII digits0x?? 0x30 through 0x39 Ext bit | last ASCII digit0x?? 0xb0 through 0xb9 The Domain IE 0x49 present for direct agent call The length of the Domain IE 0x? The Domain type = ACD Split0x81 ACD split * The 1st to N-1 ASCII digits0x?? 0x30 through 0x39 Ext bit | last ASCII digit0x?? 0xb0 through 0xb9 Call Options IE0x4b Length of Call Option IE0x02 Option = Number of Rings0x81 Value = The Number of Rings0x8X 0x82 through 0x8f Call Options IE0x4b Length of Call Option IE0x02 Option = Alerting order0x82 Value = Destination first0x81 Call Options IE0x4b Length of Call Option IE0x01 Option = supervisor assist0x87 Call Options IE0x4b Length of Call Option IE0x01 Option = direct agent call0x86 Call Options IE0x4b Length of Call Option IE0x01 Option = priority call0x83 Call Options IE0x4b Length of Call Option IE0x01 Option = return ack flag0x8c Call Option IE0x4b Length of Call Option IE0x02 Option=Answering Machine Detection0x8e Value0x8x 0x80=Administered Treatment, 0x81=Drop, 0x82=Answer (Continued on next page)
Call Control Capability Group Issue 6 June 1997 5-41 The switch supports only certain combinations of call options. Not all optional bytes can be present. Appendix A describes how the switch validates the various optional Information Elements that may be present in this request and how the switch determines which of the internal call types it will attempt to establish. Service Circuit IE0x4e Length of Service Circuit IE0x01 Tone Detection/Call Classification0x81 Third Party Make Call Request — (continued)
Byte Level Messages 5-42Issue 6 June 1997 Third Party Take Control Request Byte Description Byte Value Comments Protocol Discriminator 0x08 BRI CRV Length 0x01 or 0x02 First CRV Byte 0x? assigned value Second CRV Byte0x? assigned value Message Type 0x64 REGister Locking Shift to Code Set 6 0x96 Facility IE 0x1c Length of Facility 0x?? computed length Q.932 Supplementary Service 0x91 component type tag = invoke 0xa1 INVOKE component component length 0x?? computed length component length0x?? long form (length > 127) invoke identifier tag 0x02 invoke identifier length 0x01 invoke identifier 0x??initiating — odd value operation value tag 0x02 operation value length 0x01 Operation Value = Third party take control0xb6 Q.931 IEs tag 0x40 Q.931 IEs length 0x?? computed length Q.931 IEs length0x?? long form (length > 127) Call Identity IE 0x10 Length of Call Identity 0x02 computed value * Call identifier (2 bytes) 0x?? switch-assigned value
Call Control Capability Group Issue 6 June 1997 5-43 Call Control: REGister Messages Sent by the switch None for Call Control. Call Control: FACility Messages Sent by the Adjunct A FACility message is used to initiate an action with an existing association. All FACility messages have the Protocol Discriminator and the CRV followed by a FAC type = 0x62. The Call Control message encodings located in this section are: nThird Party Clear Call Request nThird Party Selective Drop Request nThird Party Selective Hold Request nThird Party Listen-Disconnect Request nThird Party Listen-Reconnect Request nThird Party Reconnect Request nThird Party Merge Request nThird Party Relinquish Control Request nThird Party Send DTMF Digits Request nRedirect Call Request
Byte Level Messages 5-44Issue 6 June 1997 Third Party Clear Call Request Byte Description Byte Value Comments Protocol Discriminator 0x08 BRI CRV Length 0x01 or 0x02 First CRV Byte 0x? Second CRV Byte0x? Message Type 0x62 FACility Locking Shift to Code Set 6 0x96 Facility IE 0x1c Length of Facility IE 0x?? computed length Q.932 Supplementary Service 0x91 component type tag 0xa1 INVOKE component component length 0x?? computed length component length0x?? long form (length > 127) invoke identifier tag 0x02 invoke identifier length 0x01 invoke identifier 0x??initiator — odd value operation value tag 0x02 operation value length 0x01 Operation Value = 3P Clear Call 0x93
Call Control Capability Group Issue 6 June 1997 5-45 Third Party Selective Drop Request Byte Description Byte Value Comments Protocol Discriminator 0x08 BRI CRV Length 0x01 or 0x02 First CRV Byte 0x? Second CRV Byte0x? Message Type 0x62 FACility Locking Shift to Code Set 6 0x96 Facility IE 0x1c Length of Facility IE 0x?? computed length Q.932 Supplementary Service 0x91 component type tag 0xa1 INVOKE component component length 0x?? computed length component length0x?? long form (length > 127) invoke identifier tag 0x02 invoke identifier length 0x01 invoke identifier 0x??initiator — odd value operation value tag 0x02 operation value length 0x01 Operation Value = 3P Sel. Drop0x88 Q.931 IEs tag 0x40 Q.931 IEs length 0x?? computed length Q.931.IEs length0x?? long form (length > 127) User-User IE0x7e User-to-user information length of user-user0x?? computed length protocol discriminator0x?? *user information0x?? Locking Shift to Code Set 6 0x96 The Party Identifier IE 0x44 Length of the IE 0x01 or 0x02 Ext bit | Party ID 0x?? Ext bit | Party ID (second byte) 0x?? Resource Identifier IE0x51 Length of IE0x01 Resource type0x82 Tone
Byte Level Messages 5-46Issue 6 June 1997 Third Party Selective Hold Request Byte Description Byte Value Comments Protocol Discriminator 0x08 BRI CRV Length 0x01 or 0x02 First CRV Byte 0x? Second CRV Byte0x? Message Type 0x62 FACility Locking Shift to Code Set 6 0x96 Facility IE 0x1c Length of Facility IE 0x?? computed length Q.932 Supplementary Service 0x91 component type tag 0xa1 INVOKE component component length 0x?? computed length component length0x?? long form (length > 127) invoke identifier tag 0x02 invoke identifier length 0x01 invoke identifier 0x??initiator — odd value operation value tag 0x02 operation value length 0x01 Operation Value = 3rd Party Hold 0x85 Q.931 IEs tag 0x40 Q.931 IEs length 0x?? computed length Q.931 IEs length0x?? long form (length > 127) Locking Shift to Code Set 6 0x96 The Party Identifier IE 0x44 Length of the IE 0x01 or 0x02 Ext bit | Party ID 0x?? Ext bit | Party ID (second byte) 0x??