Have a look at the manual Lucent Technologies DEFINITY Enterprise Communications Server Release 5, CallVisor, ASAI Protocol Reference Instructions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Routing Capability Group Issue 6 June 1997 5-117 Routing: RELease COMplete Messages Sent by Both the switch and the Adjunct A RELease COMplete message terminates an association on an existing CRV. All RELease COMplete messages have the Protocol Discriminator and the CRV followed by a REL COM type = 0x5a. Routing: Terminate ASAI Association With Normal Clearing Routing: A Message Is Not Understood — Association Aborted Byte Description Byte Value Comments Protocol Discriminator 0x08 BRI CRV Length 0x01 or 0x02 First CRV Byte 0x? Second CRV Byte0x? Message Type 0x5a RELease COMplete The Cause IE 0x08 Length of IE 0x02 Ext bit | coding standard | location0x80 or 0x81 Ext bit | Class | Value in Class 0x90 Normal Clearing Byte Description Byte Value Comments Protocol Discriminator 0x08 BRI CRV Length 0x01 or 0x02 First CRV Byte 0x? Second CRV Byte0x? Message Type 0x5a RELease COMplete Cause IE 0x08 length of Cause IE 0x02 computed length Ext bit | coding standard | location0x80, 0x81, 0xe0, 0xe Cause Value 0x?? cause-dependent
Byte Level Messages 5-118Issue 6 June 1997 Routing: Endpoint Rejects an Invalid/Protocol Violation FIE — Terminates Association Byte Description Byte Value Comments Protocol Discriminator 0x08 BRI CRV Length 0x01 or 0x02 First CRV Byte 0x? Second CRV Byte0x? Message Type 0x5a RELease COMplete Locking Shift to Code Set 6 0x96 Facility IE 0x1c Length of Facility IE 0x?? computed length Q.932 Supplementary Service 0x91 component type tag 0xa4 REJECT component length 0x?? computed length invoke identifier tag 0x02 invoke identifier length 0x01 0x0 if null invoke-id invoke identifier0x?? active invoke-id; omitted if null Problem tag 0x?? Problem-specific Problem length 0x01 Problem 0x?? Problem-specific
Routing Capability Group Issue 6 June 1997 5-119 Routing: Endpoint Aborts an Association NOTE: The switch always supplies a cause value when it aborts an association; the adjunct may optionally supply a cause value. Byte Description Byte Value Comments Protocol Discriminator 0x08 BRI CRV Length 0x01 or 0x02 First CRV Byte 0x? Second CRV Byte0x? Message Type 0x5a RELease COMplete Locking Shift to Code Set 6 0x96 Facility IE 0x1c Length of Facility IE 0x?? computed length Q.932 Supplementary Service 0x91 component type tag 0xa1 INVOKE component component length 0x?? computed length component length0x?? long form (length > 127) invoke identifier tag 0x02 invoke identifier length 0x01 invoke identifier 0x?? operation value tag 0x02 operation value length 0x01 Operation Value = Abort 0xbe Q.931 IEs tag 0x40 Q.931 IEs length 0x?? computed length Q.931 IEs length0x?? long form (length > 127) The Cause IE0x08 NOTE 1 Length of IE 0x02 Ext bit | coding standard | location0x?? cause- and direction-specific Ext bit | Class | Value in Class0x?? cause-specific
Byte Level Messages 5-120Issue 6 June 1997 Request Feature Capability Group Request Feature: REGister Messages Sent by the Adjunct A REGister message initiates an association on a CRV. All REGister messages have the Protocol Discriminator and the CRV followed by a REG type = 0x64. Agent Login Request (Continued on next page) Byte Description Byte Value Comments Protocol Discriminator 0x08 BRI CRV Length 0x01 or 0x02 First CRV Byte 0x? assigned value Second CRV Byte0x? assigned value Message Type 0x64 REGister Locking Shift to Code Set 6 0x96 Facility IE 0x1c Length of Facility 0x?? computed length Q.932 Supplementary Service 0x91 component type tag = invoke 0xa1 INVOKE component component length 0x?? computed length component length0x?? long form (length > 127) invoke identifier tag 0x02 invoke identifier length 0x01 invoke identifier 0x??initiating — odd value operation value tag 0x02 operation value length 0x01 Operation Value = Feature Request0x8f Q.931 IEs tag 0x40 Q.931 IEs length 0x?? computed length Q.931 IEs length0x?? long form (length > 127) Locking Shift to Code Set 6 0x96 User Code IE 0x02 Length of User Code IE 0x? computed length Type of user Code = Login Digits 0x82 collected data indicator 0xc0
Request Feature Capability Group Issue 6 June 1997 5-121 Agent Login Request —(continued) Byte Description Byte Value Comments * The 1st to N-1 ASCII digits 0x3X 0x30 through 0x39 Ext bit | The last ASCII digit 0xbX 0xb0 through 0xb9 The Feature IE 0x48 The length of the feature IE 0x01 Feature = Login 0x82 The Domain IE 0x49 The length of the Domain IE 0x? The Domain type = ACD Split 0x81 ACD split * The first to N-1 ASCII digits 0x?? 0x30 through 0x39 Exit bit | last ASCII digit 0x?? 0xb0 through 0xb9 The Domain IE 0x49 The length of the Domain IE 0x? computed length The Domain type = Extension 0x83 Agent Extension * The 1st to N-1 ASCII digits 0x3X 0x30 through 0x39 Ext bit | last ACSII digit 0xbX 0xb0 through 0xb9 The Domain IE0x49 The length of the Domain IE0x02 The Domain type = Work Mode0x86 The Work Mode0x8X 0x81, 0x82, 0x83, or 0x84
Byte Level Messages 5-122Issue 6 June 1997 Agent Logout Request (Continued on next page) Byte Description Byte Value Comments Protocol Discriminator 0x08 BRI CRV Length 0x01 or 0x02 First CRV Byte 0x? assigned value Second CRV Byte0x? assigned value Message Type 0x64 REGister Locking Shift to Code Set 6 0x96 Facility IE 0x1c Length of Facility 0x?? computed length Q.932 Supplementary Service 0x91 component type tag = invoke 0xa1 INVOKE component component length 0x?? computed length component length0x?? long form (length > 127) invoke identifier tag 0x02 invoke identifier length 0x01 invoke identifier 0x??initiating — odd value operation value tag 0x02 operation value length 0x01 Feature Request Operation Value 0x8f Q.931 IEs tag 0x40 Q.931 IEs length 0x?? computed length Q.931 IEs length0x?? long form (length > 127) Locking Shift to Code Set 6 0x96 The Feature IE 0x48 The length of the feature IE 0x01 Feature = Logout 0x83 The Domain IE 0x49 The length of the Domain IE 0x? The Domain type = ACD Split 0x81 ACD split * The first to N-1 ASCII digits 0x?? 0x30 through 0x39 Exit bit | last ASCII digit 0x?? 0xb0 through 0xb9 The Domain IE 0x49 The length of the Domain IE 0x? computed length The Domain type = Extension 0x83 Agent Extension * The 1st to N-1 ASCII digits 0x3X 0x30 through 0x39 Ext bit | last ACSII digit 0xbX 0xb0 through 0xb9
Request Feature Capability Group Issue 6 June 1997 5-123 Agent Logout Request —(continued) Byte Description Byte Value Comments The length of the Domain IE 0x? computed length The Domain type = Extension 0x83 Agent Extension * The 1st to N-1 ASCII digits 0x3X 0x30 through 0x39 Ext bit | last ACSII digit 0xbX 0xb0 through 0xb9 Domain IE 0x49 Specifies Reason Code for Logout Length of Domain IE 0x? Computed length Domain type=Reason code 0x98 Reason Codes Reason Code 0x8X 0x81 - 0x89 (Reason codes 1-9)
Byte Level Messages 5-124Issue 6 June 1997 Change Agent Work Mode Request Byte Description Byte Value Comments Protocol Discriminator 0x08 BRI CRV Length 0x01 or 0x02 First CRV Byte 0x? assigned value Second CRV Byte0x? assigned value Message Type 0x64 REGister Locking Shift to Code Set 6 0x96 Facility IE 0x1c Length of Facility 0x?? computed length Q.932 Supplementary Service 0x91 component type tag = invoke 0xa1 INVOKE component component length 0x?? computed length component length0x?? long form (length > 127) invoke identifier tag 0x02 invoke identifier length 0x01 invoke identifier 0x??initiating — odd value operation value tag 0x02 operation value length 0x01 Feature Request Operation Value 0x8f Q.931 IEs tag 0x40 Q.931 IEs length 0x?? computed length Q.931 IEs length0x?? long form (length > 127) Locking Shift to Code Set 6 0x96 The Feature IE 0x48 The length of the feature IE 0x01 Feature = Change in Work Modes 0x81 The Domain IE 0x49 The length of the Domain IE 0x? The Domain type = ACD Split 0x81 ACD split * The first to N-1 ASCII digits 0x?? 0x30 through 0x39 Exit bit | last ASCII digit 0x?? 0xb0 through 0xb9 The Domain IE 0x49 The length of the Domain IE 0x? computed length (Continued on next page)
Request Feature Capability Group Issue 6 June 1997 5-125 Change Agent Work Mode Request —(continued) Byte Description Byte Value Comments The Domain type = Extension 0x83 Agent Extension * The 1st to N-1 ASCII digits 0x3X 0x30 through 0x39 Ext bit | last ACSII digit 0xbX 0xb0 through 0xb9 The Domain IE 0x49 The length of the Domain IE 0x02 The Domain type = Work Mode 0x86 The Work Mode 0x?? 0x81, 08x2, 0x83, or 0x84 Domain IE 0x49 Reason Code (if change to AUX) Length of Domain IE 0x? Computed length Domain type=Reason code 0x98 Reason Codes Reason Code 0x8X 0x81 - 0x89 (Reason codes 1-9)
Byte Level Messages 5-126Issue 6 June 1997 Send All Calls Feature Activation Byte Description Byte Value Comments Protocol Discriminator 0x08 BRI CRV Length 0x01 or 0x02 First CRV Byte 0x? assigned value Second CRV Byte0x? assigned value Message Type 0x64 REGister Locking Shift to Code Set 6 0x96 Facility IE 0x1c Length of Facility 0x?? computed length Q.932 Supplementary Service 0x91 component type tag = invoke 0xa1 INVOKE component component length 0x?? computed length component length0x?? long form (length > 127) invoke identifier tag 0x02 invoke identifier length 0x01 invoke identifier 0x??initiating — odd value operation value tag 0x02 operation value length 0x01 Operation Value = Feature Request 0x8f Q.931 IEs tag 0x40 Q.931 IEs length 0x?? computed length Q.931 IEs length0x?? long form (length > 127) Redirecting Number IE 0x74 Length of Redirecting Number IE 0x? computed length Address Type & Numbering Plan 0x?? See Chapter 4 * ASCII address digits 0x??, 0x30 through 0x39, 0x23 (#), 0x2a (*) Locking Shift to Code Set 6 0x96 The Feature IE 0x48 The length of the feature IE 0x01 Feature = Send All Calls 0x8c