    Have a look at the manual Lucent Technologies Definity Audix System Release 4.0 Maintenance Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							DEFINITY AUDIX System Maintenance  585-300-121  Issue 1
    May 1999
    Voice, Control, and LAN Links 
    5-7 Voice Group Problems 
    5
    Voice Group Problems
    Refer to Ta b l e  5 - 4, Voic e Group  Alarms and  Rep air Proc ed ures, for a list of 
    alarms and  repair p roc ed ures ad d ressed  to the voic e p orts. Perform all 
    numb ered rep air ac tions in ord er as shown. Alarms ap p ear in the 
    D I SPL AY A L A RM S 
    sc reen und er the resourc e typ e:
    VOICE_GRP
    Table 5-4. Voice Group Alarms and Repair Procedures 
    Fault
    CodeFault
    DescriptionAlarm
    LevelError Log
    ResourceRepair
    Action
    0
    Voic e p ort translation 
    badMAJORVOICE_GRP
    On the
     CHANGE VOICE-GROUP sc reen, 
    ad minister at least one voic e port.
    1
    A switc h port is not in the 
    AUDIX translations. An 
    extra or d ifferent 
    extension exists in the 
    switc h translations for the 
    hunt g roup .MINORVOICE_GRP
    1. Compare the switc h and system 
    voic e p ort translations for a 
    mismatc h. Ad d  the missing  
    extension in the system 
    translations, or c hange the different 
    extension to matc h that in the 
    switc h translations.
    2. Exec ute the 
    CHANGE VOICE-GROUP 
    sc reen to c lear the alarm.
    3. If the mismatc h is not fixed, 
    translation faults will immediately 
    return. To verify the alarm is g one 
    for other faults, p lac e c alls to the 
    system hunt g roup numb er. To 
    c yc le throug h the hunt g roup , 
    p lac e enoug h c alls to eq ual the 
    memb ers of the hunt g roup (not the 
    number of c alls ac c ord ing  to 
    translated p orts in the system voic e 
    p ort translations).
    2
    More than 25% of the 
    voic e ports are out of 
    servic e. This is an 
    esc alation of other 
    alarms that may b e 
    ac tive on the voic e ports.MAJORVOICE_GRP
    1. Look at the
     STATUS VOICE-GROUP 
    and
     DISPL AY A LA RM  sc reens to 
    d etermine whic h voic e p orts are 
    out of servic e and why.
    2. Determine what ac tion is need ed  to 
    bring individual voice ports back 
    into servic e.
    Continued on next page 
    						
    							DEFINITY AUDIX System Maintenance  585-300-121  Issue 1
    May 1999
    Voice, Control, and LAN Links 
    5-8 Link Ports Problems 
    5
    Tab le 5-5, Voic e Group  Errors, lists the errors whic h, if exc eed ing  a c ertain 
    threshold, may g enerate the listed  alarm faults. Errors are logg ed  in the 
    D ISPL AY 
    ERRO RS
     sc reen. 
    Link Ports Problems
    When the DEFINITY AUDIX System attemp ts to use unp urc hased  voic e ports to 
    do message-waiting updates or audit switch names, errors will be logged, 
    eventually setting  off an alarm. Imp rop er switc h translations most likely c ause 
    these errors and  alarms. 
    Refer to Ta b l e  5 - 6, Link Port Alarms and Rep air Proc ed ures, for a list of alarms 
    and  repair p roc ed ures ad d ressed  to the voic e p orts. Perform all numb ered rep air 
    ac tions in order as shown. Alarms ap p ear in the 
    D ISPL AY AL A RM S sc reen und er the 
    resourc e typ e:
    Table 5-5. Voice Group Errors
    Error
    ResourceError
    Code DescriptionFault
    ResourceFault
    Code
    VOICE_GRP 103
    No voic e port translations VOICE_GRP 0
    VOICE_GRP 104
    AUDIX and switc h translations d iffer VOICE_GRP 1
    VOICE_GRP 105
    AUDIX and switc h translations OK VOICE_GRP 1
    VOICE_GRP 106
    Voic e p ort translations OK VOICE_GRP 0
    VOICE_GRP 107
    Too many voic e p orts OOS-R/OOS-F VOICE_GRP 2
    VOICE_GRP 108
    Suffic ient voic e p orts in servic e VOICE_GRP 2
    LINK_PORTS 
    						
    							DEFINITY AUDIX System Maintenance  585-300-121  Issue 1
    May 1999
    Voice, Control, and LAN Links 
    5-9 Link Ports Problems 
    5
    Tab le 5-7, Link Port Errors, lists the errors log ged  in the D ISPL AY ERRO RS sc reen. 
    These errors, if exc eed ing  a c ertain threshold , may g enerate the listed  fault 
    alarms. Note that pseud onyms of listed  error resourc es may app ear on the error 
    log; these “ hid d en”  resourc es are listed  in p arenthesis with their related  
    resources. 
    Table 5-6. Link Port Alarms and Repair Procedures
    Fault
    CodeFault
    DescriptionAlarm
    LevelError Log
    ResourceRepair
    Action
    0
    Chec k error log MINORLINK_PORTS
    1. Comp are the switc h and AUDIX voic e p ort 
    translations for a mismatc h.  Matc h the two.
    2. Exec ute the
     CHANGE VOICE-GROUP sc reen to 
    c lear the alarm.
    3. If the mismatc h is not fixed, translation faults will 
    immed iately return.  To verify the alarm is g one 
    for other faults, p lac e c alls to the AUDIX hunt 
    g roup  numb er.  To c yc le throug h the hunt group , 
    p lac e enough c alls to eq ual the memb ers of the 
    hunt g roup  (not the numb er of c alls ac c ording  to 
    translated p orts in the AUDIX voic e p ort 
    translations).
    4. If the alarm returns several minutes after b eing 
    c leared  b y
     CHANGE VOICE-GROUP, restart the 
    system using RESET SYSTEM RESTA RT.
    Table 5-7. Link Port Errors
    Error
    ResourceError
    Code DescriptionFault
    ResourceFault
    Code
    LINK_PORTS
    24 No switc h line responseLINK_PORTS 0
    LINK_PORTS 104
    System/switc h translations d ifferLINK_PORTS 0
    LINK_PORTS 105
    System/switc h translations OKLINK_PORTS 0
    LINK_PORTS 106
    System/switc h translations OKLINK_PORTS 0
    LINK_PORTS 109
    LWC not enab led for a lineLINK_PORTS 0
    LINK_PORTS 112
    VSC p roc ess d iedLINK_PORTS 0
    LINK_PORTS 229
    Unab le to b usy or release p ortLINK_PORTS 0
    LINK_PORTS 8078
    RCM to SD state sync hronization p rob lemLINK_PORTS 0 
    						
    							DEFINITY AUDIX System Maintenance  585-300-121  Issue 1
    May 1999
    Voice, Control, and LAN Links 
    5-10 Switch (Remote DCS Switch) Problems 
    5
    Switch (Remote DCS Switch) 
    Problems
    When the DEFINITY AUDIX System op erates in the Control Link Emulation mod e, 
    the following  p rob lems may oc c ur with the c ontrol link b etween the remote DCS 
    switc h and  the DEFINITY AUDIX System. Alarms and  rep air ac tions are g roup ed  
    tog ether in Ta b l e  5 - 8, Switc h (Remote DCS Switc h) Alarms and  Rep air 
    Proc ed ures. Perform all numb ered  rep air ac tions in ord er as shown.
    Alarms ap p ear in the 
    D I SPL AY A L A RM S sc reen under the resourc e typ e:
    Tab le 5-9, Switc h (Remote DCS Switc h) Errors, lists the errors log g ed  in the 
    D ISPL AY ERRO RS sc reen. These errors, if exc eed ing a c ertain threshold , may 
    g enerate the listed  fault alarms.
    SWITCH
    Table 5-8. Switch (Remote DCS Switch) Alarms and Repair Procedures
    Fault
    CodeFault
    DescriptionAlarm
    LevelError Log
    ResourceRepair
    Action
    0
    BX25 level 4 translation MINORSWITCH
    Chec k and c ompare AUDIX and switc h 
    translations for the data link. If the switc h is 
    not transferring d ata, c ontinuous attemp ts 
    are made to bring the link back into 
    servic e. The alarm will c lear when the link 
    test p asses or the switc h p asses d ata.
    1
    Remote switc h out of 
    d ata transfer for an 
    extend ed  p eriod  of 
    time, and  is not 
    recoveringWARNINGSWITCH
    1. Resolve switc h link fault.
    2. Verify remote switc h is c orrec tly 
    translated and host switc h is c orrec tly 
    translated. 
    						
    							DEFINITY AUDIX System Maintenance  585-300-121  Issue 1
    May 1999
    Voice, Control, and LAN Links 
    5-11 Switch (Remote DCS Switch) Problems 
    5
     
    Table 5-9. Switch (Remote DCS Switch) Errors
    Error
    ResourceError
    Code DescriptionFault
    ResourceFault
    Code
    SWITCH 81
    Diagnostic  MP 143 failed  (c hec k if switc hlink is 
    op erational) SWITCH 0
    SWITCH 361
    Remote switc h translation removedSWITCH 0,1
    SWITCH 360
    Bad  BX25 level 4 translationSWITCH 0
    SWITCH 363
    Host switc h data transfer rec overedSWITCH 0,1
    SWITCH 8902
    Remote switc h out of data transferSWITCH 1 
    						
    							DEFINITY AUDIX System Maintenance  585-300-121  Issue 1
    May 1999
    Voice, Control, and LAN Links 
    5-12 Switch Link (Control Link) Problems 
    5
    Switch Link (Control Link) Problems
    Refer to Table 5-10, Switc h Link (Control Link) Alarms and  Rep air Proc ed ures, for 
    a list of alarms and  rep air p roc ed ures ad d ressed  to the Switc h Link. These oc c ur 
    when the DEFINITY AUDIX System is op erating  in the Control Link Integ ration 
    mod e. Perform all numb ered  rep air ac tions in ord er as shown. Alarms ap p ear in 
    the 
    DISPLAY ALARMS sc reen und er the resourc e typ e:
    SWITCHLINK
    Table 5-10. Switch Link (Control Link) Alarms and Repair Procedures 
    Fault
    CodeFault
    DescriptionAlarm
    LevelError Log
    ResourceRepair
    Action
    0
    USART failed loop  test WARNINGSWITCHLINK
    1. Run
     TEST SWITCH-LINK 
    LONG.
    2. If that fails, run
     TEST 
    BOARD
    .
    3. As a last resort, rep lac e 
    the TN568.
    1
    Lost DCIU c arrier (Level 
    1)MAJORSWITCHLINK
    1. Connec t an external 
    loop bac k p lug to the 
    Y-c a b le  Po r t  B  
    c onnec tion and  run
     TEST 
    SWITCH-LINK 
    LOOPAROUND
     test.
    2. Physic ally c hec k c ab ling  
    and  wiring . Start at the 
    AUDIX end .
    3. Chec k the IDI or MPDM 
    and  rep lac e if nec essary.
    2
    Lost protoc ol (Level 2) WARNINGSWITCHLINK
    1. Chec k the switc h 
    translations.
    2. Run
     TEST SWITCH-LINK 
    LONG.
    3. Physic ally c hec k c ab ling  
    and  wiring .  Start at the 
    AUDIX end .
    4. Chec k the IDI or MPDM 
    and  rep lac e if nec essary.
    Continued on next page 
    						
    							DEFINITY AUDIX System Maintenance  585-300-121  Issue 1
    May 1999
    Voice, Control, and LAN Links 
    5-13 Switch Link (Control Link) Problems 
    5
    3
    Host out of d ata transfer MAJORSWITCHLINK
    1. Chec k switc hlink in/out 
    of d ata transfer status 
    using  the STATUS 
    SWITCH-LINK
     sc reen.
    2. Connec t an external 
    loop bac k p lug to the 
    Y-c a b le  Po r t  B  
    c onnec tion and  run 
    TEST 
    SWITCH-LINK 
    LOOPAROUND
    .
    3. Chec k IDI or MPDM and  
    rep lac e if nec essary.
    4
    Bad switc h numb er MAJORSWITCHLINK
    1. Chec k the switc h 
    translations.
    2. Chang e the switc h 
    number using  the 
    c hang e switc h-link 
    op tion in the SWITCH LINK 
    DCIU-SCI 
    sc reen. 
    Running  this also c lears 
    the alarm.
    3. Make remote c all to 
    c hec k if the number is 
    correct.
    5
    Bad AUDIX numb er MAJORSWITCHLINK
    1. Chec k AUDIX 
    translations.
    2. Chang e the AUDIX 
    number using  the 
    c hang e switc h-link 
    op tion in the 
    SWITCH LINK 
    DCIU-SCI sc reen. 
    Running  this also c lears 
    the alarm.
    3. Make a test c all to a 
    voic e port to see if a c all 
    c an be p lac ed.
    98
    Out of servic e - c raft 
    (OOS-C)WA RN I N GSWITCHLINK
    The alarm is c leared  when 
    RELEASE SWITCH-LINK is 
    exec uted .
    Table 5-10. Switch Link (Control Link) Alarms and Repair Procedures  — Continued
    Fault
    CodeFault
    DescriptionAlarm
    LevelError Log
    ResourceRepair
    Action
    Continued on next page 
    						
    							DEFINITY AUDIX System Maintenance  585-300-121  Issue 1
    May 1999
    Voice, Control, and LAN Links 
    5-14 Switch Link (Control Link) Problems 
    5
    Table 5-11, Switch Link (Control Link) Errors, lists the errors log g ed  in the D ISPL AY 
    ERRO RS
     sc reen. These errors, if exc eed ing  a c ertain threshold , may g enerate the 
    listed  fault alarms. 
    Tab le 5-12, Test Switchlink Results, lists ind ivid ual switchlink tests and  test results 
    when 
    TEST SWITCH-LINK is run, and possible repair actions. 
    Table 5-11. Switch Link (Control Link) Errors
    Error
    ResourceError
    Code DescriptionFault
    ResourceFault
    Code
    SWITCHLINK 81
    Diagnostic  MP 143 failed  (c hec k if switc h link is 
    op erational)SWITCHLINK 6
    SWITCHLINK 81
    Diagnostic  MP 144 failed  (switc h link internal 
    looparound test)SWITCHLINK 3
    SWITCHLINK 81
    Long  d emand seq uenc e MP 146 failed  (reset the 
    switc h link)SWITCHLINK 3
    SWITCHLINK 362
    Chang e switc h-link exec utedSWITCHLINK 4,5
    SWITCHLINK 363
    Host switc h data transfer rec overedSWITCHLINK 0,1,2,
    3, 6
    SWITCHLINK 364
    X25 d river time-outSWITCHLINK 6
    SWITCHLINK 365
    Bad  switc h numb er in messageSWITCHLINK 4
    SWITCHLINK 366
    Bad  AUDIX number in messageSWITCHLINK 5
    SWITCHLINK 367
    USART failed  loop b ac k testSWITCHLINK 0
    SWITCHLINK 368
    USART p assed loopb ac k testSWITCHLINK 0
    SWITCHLINK 370
    Lost DCIU c arrier (Level 1)SWITCHLINK 1
    SWITCHLINK 371
    Rec overed  DCIU c arrier (Level 1)SWITCHLINK 1
    SWITCHLINK 372
    Lost p rotoc ol (Level 2)SWITCHLINK 2
    SWITCHLINK 373
    Rec overed  p rotoc ol (Level 2)SWITCHLINK 2
    SWITCHLINK 8902
    Host switc h out of d ata transferSWITCHLINK 6
    Table 5-12. Test Switchlink Results 
    Te s t  N a m eTest Result 
    (Passed) Test Result (Failed) Test Result (Abort) Action
    Te s t  U A RT
    (Control Link 
    Only)
    P Pa ss e d
    F Level 1 failure DSR or DCD not ac tive
    F UART Test Timeout System error (c all RSC)
    Continued on next page 
    						
    							DEFINITY AUDIX System Maintenance  585-300-121  Issue 1
    May 1999
    Voice, Control, and LAN Links 
    5-15 Switch Link (Control Link) Problems 
    5
    Re s e t 
    Loop aroundP Pa ss e d
    Voic e Grp not b usied Busyout Voic e-g roup
    F Int loop  failure Try ag ain, rep lac e 
    TN568
    F Level 1 failure DSR or DCD not ac tive
    F Level 2 failure
    F Int loop  Timeout System error (c all RSC)
    F D a t a  Tr a n s  
    TimeoutSystem error (c all RSC)
    F Level 1 timeout System error (c all RSC)
    F Level 2 timeout System error (c all RSC)
    External Loop  
    Te s tP Pa ss e d
    F Ext loop  failure
    F Ext Loop  Timeout System error (c all RSC)
    Query data 
    transferP Pa ss e d
    F Not in Data Trans Switc h not in d ata xfer
    F D a t a  Tr a n s  
    TimeoutSystem error (c all RSC)
    Table 5-12. Test Switchlink Results  — Continued
    Te s t  N a m eTest Result 
    (Passed) Test Result (Failed) Test Result (Abort) Action
    Continued on next page 
    						
    							DEFINITY AUDIX System Maintenance  585-300-121  Issue 1
    May 1999
    Voice, Control, and LAN Links 
    5-16 LAN Problems 
    5
    LAN Problems
    Refer to Tab le 5-13, Loc al Area Network (LAN) Alarms and  Rep air Proc ed ures, 
    for a list of alarms and  rep air p roc edures ad d ressed  to the system’s Loc al Area 
    Network interfac e, whic h sup p orts c lient software ap p lic ations suc h as Intuity 
    Messag e Manag er. Perform all d ashed rep air ac tions one at a time until the 
    p rob lem is solved . Alarms ap p ear in the 
    D ISPL AY A L ARMS sc reen und er the 
    resourc e typ e:
    Tab le 5-14, Loc al Area Network (LAN) Errors, lists the errors log g ed  in the DISPL AY 
    ERRORS
     sc reen. These errors, if exc eed ing  a c ertain threshold , may g enerate the 
    listed  fault alarms. 
    LANINTF
    Table 5-13. Local Area Network (LAN) Alarms and Repair Procedures
    Fault
    CodeFault
    DescriptionAlarm
    LevelError Log
    ResourceRepair
    Action
    0
    No ethernet c irc uit MINORLANINTF
    — Manually reboot the system
    —Run 
    TEST LAN or TEST LAN LONG 
    c ommand
    — Rep lac e the TN568
    1
    Ethernet internal MINORLANINTF
    — Run test lan or 
    TEST LAN LONG 
    c ommand
    — Rep lac e the TN568
    2
    FW ethernet loop MINORLANINTF
    — Examine the TN568 c abling  to 
    the LAN
    —  Verify c orrec t setting of network 
    integ rity op tion switc h
    — The c ustomer’s LAN is 
    inop erab le and the c ustomer 
    must rep air it.
    3
    Ping  g ateway WARNINGLANINTF
    — Examine the data on the 
    SYSTEM-PARAMETERS IMAPI 
    sc reen
    — Verify that the c ustomer’s LAN 
    is op erab le.
    — Manually reboot the system.
    — Rep lac e the TN568 
    						