Have a look at the manual Lucent Technologies Definity Audix System Release 4.0 Maintenance Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
DEFINITY AUDIX System Maintenance 585-300-121 Issue 1 May 1999 Voice, Control, and LAN Links 5-7 Voice Group Problems 5 Voice Group Problems Refer to Ta b l e 5 - 4, Voic e Group Alarms and Rep air Proc ed ures, for a list of alarms and repair p roc ed ures ad d ressed to the voic e p orts. Perform all numb ered rep air ac tions in ord er as shown. Alarms ap p ear in the D I SPL AY A L A RM S sc reen und er the resourc e typ e: VOICE_GRP Table 5-4. Voice Group Alarms and Repair Procedures Fault CodeFault DescriptionAlarm LevelError Log ResourceRepair Action 0 Voic e p ort translation badMAJORVOICE_GRP On the CHANGE VOICE-GROUP sc reen, ad minister at least one voic e port. 1 A switc h port is not in the AUDIX translations. An extra or d ifferent extension exists in the switc h translations for the hunt g roup .MINORVOICE_GRP 1. Compare the switc h and system voic e p ort translations for a mismatc h. Ad d the missing extension in the system translations, or c hange the different extension to matc h that in the switc h translations. 2. Exec ute the CHANGE VOICE-GROUP sc reen to c lear the alarm. 3. If the mismatc h is not fixed, translation faults will immediately return. To verify the alarm is g one for other faults, p lac e c alls to the system hunt g roup numb er. To c yc le throug h the hunt g roup , p lac e enoug h c alls to eq ual the memb ers of the hunt g roup (not the number of c alls ac c ord ing to translated p orts in the system voic e p ort translations). 2 More than 25% of the voic e ports are out of servic e. This is an esc alation of other alarms that may b e ac tive on the voic e ports.MAJORVOICE_GRP 1. Look at the STATUS VOICE-GROUP and DISPL AY A LA RM sc reens to d etermine whic h voic e p orts are out of servic e and why. 2. Determine what ac tion is need ed to bring individual voice ports back into servic e. Continued on next page
DEFINITY AUDIX System Maintenance 585-300-121 Issue 1 May 1999 Voice, Control, and LAN Links 5-8 Link Ports Problems 5 Tab le 5-5, Voic e Group Errors, lists the errors whic h, if exc eed ing a c ertain threshold, may g enerate the listed alarm faults. Errors are logg ed in the D ISPL AY ERRO RS sc reen. Link Ports Problems When the DEFINITY AUDIX System attemp ts to use unp urc hased voic e ports to do message-waiting updates or audit switch names, errors will be logged, eventually setting off an alarm. Imp rop er switc h translations most likely c ause these errors and alarms. Refer to Ta b l e 5 - 6, Link Port Alarms and Rep air Proc ed ures, for a list of alarms and repair p roc ed ures ad d ressed to the voic e p orts. Perform all numb ered rep air ac tions in order as shown. Alarms ap p ear in the D ISPL AY AL A RM S sc reen und er the resourc e typ e: Table 5-5. Voice Group Errors Error ResourceError Code DescriptionFault ResourceFault Code VOICE_GRP 103 No voic e port translations VOICE_GRP 0 VOICE_GRP 104 AUDIX and switc h translations d iffer VOICE_GRP 1 VOICE_GRP 105 AUDIX and switc h translations OK VOICE_GRP 1 VOICE_GRP 106 Voic e p ort translations OK VOICE_GRP 0 VOICE_GRP 107 Too many voic e p orts OOS-R/OOS-F VOICE_GRP 2 VOICE_GRP 108 Suffic ient voic e p orts in servic e VOICE_GRP 2 LINK_PORTS
DEFINITY AUDIX System Maintenance 585-300-121 Issue 1 May 1999 Voice, Control, and LAN Links 5-9 Link Ports Problems 5 Tab le 5-7, Link Port Errors, lists the errors log ged in the D ISPL AY ERRO RS sc reen. These errors, if exc eed ing a c ertain threshold , may g enerate the listed fault alarms. Note that pseud onyms of listed error resourc es may app ear on the error log; these “ hid d en” resourc es are listed in p arenthesis with their related resources. Table 5-6. Link Port Alarms and Repair Procedures Fault CodeFault DescriptionAlarm LevelError Log ResourceRepair Action 0 Chec k error log MINORLINK_PORTS 1. Comp are the switc h and AUDIX voic e p ort translations for a mismatc h. Matc h the two. 2. Exec ute the CHANGE VOICE-GROUP sc reen to c lear the alarm. 3. If the mismatc h is not fixed, translation faults will immed iately return. To verify the alarm is g one for other faults, p lac e c alls to the AUDIX hunt g roup numb er. To c yc le throug h the hunt group , p lac e enough c alls to eq ual the memb ers of the hunt g roup (not the numb er of c alls ac c ording to translated p orts in the AUDIX voic e p ort translations). 4. If the alarm returns several minutes after b eing c leared b y CHANGE VOICE-GROUP, restart the system using RESET SYSTEM RESTA RT. Table 5-7. Link Port Errors Error ResourceError Code DescriptionFault ResourceFault Code LINK_PORTS 24 No switc h line responseLINK_PORTS 0 LINK_PORTS 104 System/switc h translations d ifferLINK_PORTS 0 LINK_PORTS 105 System/switc h translations OKLINK_PORTS 0 LINK_PORTS 106 System/switc h translations OKLINK_PORTS 0 LINK_PORTS 109 LWC not enab led for a lineLINK_PORTS 0 LINK_PORTS 112 VSC p roc ess d iedLINK_PORTS 0 LINK_PORTS 229 Unab le to b usy or release p ortLINK_PORTS 0 LINK_PORTS 8078 RCM to SD state sync hronization p rob lemLINK_PORTS 0
DEFINITY AUDIX System Maintenance 585-300-121 Issue 1 May 1999 Voice, Control, and LAN Links 5-10 Switch (Remote DCS Switch) Problems 5 Switch (Remote DCS Switch) Problems When the DEFINITY AUDIX System op erates in the Control Link Emulation mod e, the following p rob lems may oc c ur with the c ontrol link b etween the remote DCS switc h and the DEFINITY AUDIX System. Alarms and rep air ac tions are g roup ed tog ether in Ta b l e 5 - 8, Switc h (Remote DCS Switc h) Alarms and Rep air Proc ed ures. Perform all numb ered rep air ac tions in ord er as shown. Alarms ap p ear in the D I SPL AY A L A RM S sc reen under the resourc e typ e: Tab le 5-9, Switc h (Remote DCS Switc h) Errors, lists the errors log g ed in the D ISPL AY ERRO RS sc reen. These errors, if exc eed ing a c ertain threshold , may g enerate the listed fault alarms. SWITCH Table 5-8. Switch (Remote DCS Switch) Alarms and Repair Procedures Fault CodeFault DescriptionAlarm LevelError Log ResourceRepair Action 0 BX25 level 4 translation MINORSWITCH Chec k and c ompare AUDIX and switc h translations for the data link. If the switc h is not transferring d ata, c ontinuous attemp ts are made to bring the link back into servic e. The alarm will c lear when the link test p asses or the switc h p asses d ata. 1 Remote switc h out of d ata transfer for an extend ed p eriod of time, and is not recoveringWARNINGSWITCH 1. Resolve switc h link fault. 2. Verify remote switc h is c orrec tly translated and host switc h is c orrec tly translated.
DEFINITY AUDIX System Maintenance 585-300-121 Issue 1 May 1999 Voice, Control, and LAN Links 5-11 Switch (Remote DCS Switch) Problems 5 Table 5-9. Switch (Remote DCS Switch) Errors Error ResourceError Code DescriptionFault ResourceFault Code SWITCH 81 Diagnostic MP 143 failed (c hec k if switc hlink is op erational) SWITCH 0 SWITCH 361 Remote switc h translation removedSWITCH 0,1 SWITCH 360 Bad BX25 level 4 translationSWITCH 0 SWITCH 363 Host switc h data transfer rec overedSWITCH 0,1 SWITCH 8902 Remote switc h out of data transferSWITCH 1
DEFINITY AUDIX System Maintenance 585-300-121 Issue 1 May 1999 Voice, Control, and LAN Links 5-12 Switch Link (Control Link) Problems 5 Switch Link (Control Link) Problems Refer to Table 5-10, Switc h Link (Control Link) Alarms and Rep air Proc ed ures, for a list of alarms and rep air p roc ed ures ad d ressed to the Switc h Link. These oc c ur when the DEFINITY AUDIX System is op erating in the Control Link Integ ration mod e. Perform all numb ered rep air ac tions in ord er as shown. Alarms ap p ear in the DISPLAY ALARMS sc reen und er the resourc e typ e: SWITCHLINK Table 5-10. Switch Link (Control Link) Alarms and Repair Procedures Fault CodeFault DescriptionAlarm LevelError Log ResourceRepair Action 0 USART failed loop test WARNINGSWITCHLINK 1. Run TEST SWITCH-LINK LONG. 2. If that fails, run TEST BOARD . 3. As a last resort, rep lac e the TN568. 1 Lost DCIU c arrier (Level 1)MAJORSWITCHLINK 1. Connec t an external loop bac k p lug to the Y-c a b le Po r t B c onnec tion and run TEST SWITCH-LINK LOOPAROUND test. 2. Physic ally c hec k c ab ling and wiring . Start at the AUDIX end . 3. Chec k the IDI or MPDM and rep lac e if nec essary. 2 Lost protoc ol (Level 2) WARNINGSWITCHLINK 1. Chec k the switc h translations. 2. Run TEST SWITCH-LINK LONG. 3. Physic ally c hec k c ab ling and wiring . Start at the AUDIX end . 4. Chec k the IDI or MPDM and rep lac e if nec essary. Continued on next page
DEFINITY AUDIX System Maintenance 585-300-121 Issue 1 May 1999 Voice, Control, and LAN Links 5-13 Switch Link (Control Link) Problems 5 3 Host out of d ata transfer MAJORSWITCHLINK 1. Chec k switc hlink in/out of d ata transfer status using the STATUS SWITCH-LINK sc reen. 2. Connec t an external loop bac k p lug to the Y-c a b le Po r t B c onnec tion and run TEST SWITCH-LINK LOOPAROUND . 3. Chec k IDI or MPDM and rep lac e if nec essary. 4 Bad switc h numb er MAJORSWITCHLINK 1. Chec k the switc h translations. 2. Chang e the switc h number using the c hang e switc h-link op tion in the SWITCH LINK DCIU-SCI sc reen. Running this also c lears the alarm. 3. Make remote c all to c hec k if the number is correct. 5 Bad AUDIX numb er MAJORSWITCHLINK 1. Chec k AUDIX translations. 2. Chang e the AUDIX number using the c hang e switc h-link op tion in the SWITCH LINK DCIU-SCI sc reen. Running this also c lears the alarm. 3. Make a test c all to a voic e port to see if a c all c an be p lac ed. 98 Out of servic e - c raft (OOS-C)WA RN I N GSWITCHLINK The alarm is c leared when RELEASE SWITCH-LINK is exec uted . Table 5-10. Switch Link (Control Link) Alarms and Repair Procedures — Continued Fault CodeFault DescriptionAlarm LevelError Log ResourceRepair Action Continued on next page
DEFINITY AUDIX System Maintenance 585-300-121 Issue 1 May 1999 Voice, Control, and LAN Links 5-14 Switch Link (Control Link) Problems 5 Table 5-11, Switch Link (Control Link) Errors, lists the errors log g ed in the D ISPL AY ERRO RS sc reen. These errors, if exc eed ing a c ertain threshold , may g enerate the listed fault alarms. Tab le 5-12, Test Switchlink Results, lists ind ivid ual switchlink tests and test results when TEST SWITCH-LINK is run, and possible repair actions. Table 5-11. Switch Link (Control Link) Errors Error ResourceError Code DescriptionFault ResourceFault Code SWITCHLINK 81 Diagnostic MP 143 failed (c hec k if switc h link is op erational)SWITCHLINK 6 SWITCHLINK 81 Diagnostic MP 144 failed (switc h link internal looparound test)SWITCHLINK 3 SWITCHLINK 81 Long d emand seq uenc e MP 146 failed (reset the switc h link)SWITCHLINK 3 SWITCHLINK 362 Chang e switc h-link exec utedSWITCHLINK 4,5 SWITCHLINK 363 Host switc h data transfer rec overedSWITCHLINK 0,1,2, 3, 6 SWITCHLINK 364 X25 d river time-outSWITCHLINK 6 SWITCHLINK 365 Bad switc h numb er in messageSWITCHLINK 4 SWITCHLINK 366 Bad AUDIX number in messageSWITCHLINK 5 SWITCHLINK 367 USART failed loop b ac k testSWITCHLINK 0 SWITCHLINK 368 USART p assed loopb ac k testSWITCHLINK 0 SWITCHLINK 370 Lost DCIU c arrier (Level 1)SWITCHLINK 1 SWITCHLINK 371 Rec overed DCIU c arrier (Level 1)SWITCHLINK 1 SWITCHLINK 372 Lost p rotoc ol (Level 2)SWITCHLINK 2 SWITCHLINK 373 Rec overed p rotoc ol (Level 2)SWITCHLINK 2 SWITCHLINK 8902 Host switc h out of d ata transferSWITCHLINK 6 Table 5-12. Test Switchlink Results Te s t N a m eTest Result (Passed) Test Result (Failed) Test Result (Abort) Action Te s t U A RT (Control Link Only) P Pa ss e d F Level 1 failure DSR or DCD not ac tive F UART Test Timeout System error (c all RSC) Continued on next page
DEFINITY AUDIX System Maintenance 585-300-121 Issue 1 May 1999 Voice, Control, and LAN Links 5-15 Switch Link (Control Link) Problems 5 Re s e t Loop aroundP Pa ss e d Voic e Grp not b usied Busyout Voic e-g roup F Int loop failure Try ag ain, rep lac e TN568 F Level 1 failure DSR or DCD not ac tive F Level 2 failure F Int loop Timeout System error (c all RSC) F D a t a Tr a n s TimeoutSystem error (c all RSC) F Level 1 timeout System error (c all RSC) F Level 2 timeout System error (c all RSC) External Loop Te s tP Pa ss e d F Ext loop failure F Ext Loop Timeout System error (c all RSC) Query data transferP Pa ss e d F Not in Data Trans Switc h not in d ata xfer F D a t a Tr a n s TimeoutSystem error (c all RSC) Table 5-12. Test Switchlink Results — Continued Te s t N a m eTest Result (Passed) Test Result (Failed) Test Result (Abort) Action Continued on next page
DEFINITY AUDIX System Maintenance 585-300-121 Issue 1 May 1999 Voice, Control, and LAN Links 5-16 LAN Problems 5 LAN Problems Refer to Tab le 5-13, Loc al Area Network (LAN) Alarms and Rep air Proc ed ures, for a list of alarms and rep air p roc edures ad d ressed to the system’s Loc al Area Network interfac e, whic h sup p orts c lient software ap p lic ations suc h as Intuity Messag e Manag er. Perform all d ashed rep air ac tions one at a time until the p rob lem is solved . Alarms ap p ear in the D ISPL AY A L ARMS sc reen und er the resourc e typ e: Tab le 5-14, Loc al Area Network (LAN) Errors, lists the errors log g ed in the DISPL AY ERRORS sc reen. These errors, if exc eed ing a c ertain threshold , may g enerate the listed fault alarms. LANINTF Table 5-13. Local Area Network (LAN) Alarms and Repair Procedures Fault CodeFault DescriptionAlarm LevelError Log ResourceRepair Action 0 No ethernet c irc uit MINORLANINTF — Manually reboot the system —Run TEST LAN or TEST LAN LONG c ommand — Rep lac e the TN568 1 Ethernet internal MINORLANINTF — Run test lan or TEST LAN LONG c ommand — Rep lac e the TN568 2 FW ethernet loop MINORLANINTF — Examine the TN568 c abling to the LAN — Verify c orrec t setting of network integ rity op tion switc h — The c ustomer’s LAN is inop erab le and the c ustomer must rep air it. 3 Ping g ateway WARNINGLANINTF — Examine the data on the SYSTEM-PARAMETERS IMAPI sc reen — Verify that the c ustomer’s LAN is op erab le. — Manually reboot the system. — Rep lac e the TN568