Have a look at the manual Lucent Technologies Definity Audix System Release 4.0 Maintenance Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
DEFINITY AUDIX System Maintenance 585-300-121 Issue 1 May 1999 TN568 Circuit Pack 3-15 System Time 3 Tab le 3-8, Sy st e m Ti m e Er ro rs, lists the errors log g ed in the D ISPLAY ERRORS sc reen. These errors may g enerate the ab ove alarms. Table 3-8. System Time Errors Error ResourceError Code DescriptionFault ResourceFault Code SYS_TIME 80 Initialization MP 53 ab orted (valid ates system time)SYS_TIME 0 SYS_TIME 81 Diag nostic MP 31 failed (c hec ks switc h time ag ainst system clock)SYS_TIME 2 SYS_TIME 81 Diag nostic MP 31 failed (c hec ks switc h time ag ainst system clock)SYS_TIME 3 SYS_TIME 81 Diag nostic MP 85 failed (restart system in OA&M mode)SYS_TIME 0 SYS_TIME 81 Initialization MP 53 failed (validates system time)SYS_TIME 0 SYS_TIME 81 Long demand seq uenc e MP 31 failed (c hec ks switc h time ag ainst system c loc k)SYS_TIME 2 SYS_TIME 81 Period ic MP 31 failed (c hec ks switc h time ag ainst system clock)SYS_TIME 2 SYS_TIME 81 Short d emand seq uenc e MP 31 failed (c hec ks switc h time ag ainst system c loc k)SYS_TIME 2 SYS_TIME 81 Sync hronize d emand MP 32 failed (sync hronizes switc h time with system c loc k)SYS_TIME 2 SYS_TIME 244 c hang e switc h time-zone sc reen exec uted SYS_TIME 3 SYS_TIME 245 Switc h c hang ed its time SYS_TIME 3 SYS_TIME 246 g et_date() c all failed SYS_TIME 1 SYS_TIME 247 get_date() call passed SYS_TIME 1
DEFINITY AUDIX System Maintenance 585-300-121 Issue 1 May 1999 TN568 Circuit Pack 3-16 TN568 Board Replacement 3 TN568 Board Replacement Follow the step s b elow to rep lac e the TN568. !WARNING: Static elec tric ity c an b e destruc tive to system p arts. Use an anti-static wrist strap whenever removing or installing a DEFINITY AUDIX System. Also use an anti-static mat when taking the system ap art to rep lac e the c irc uit p ac k or storag e d evic es. 1. Ensure that the c ustomer knows you will b e p owering d own the system and d isrupting servic e. 2. If it is not alread y shut d own, b ring the system to the shutd own state with the RESET SYSTEM SHUTDOWN sc reen, or the shutd own button on the fac ep late. See Ta b l e 1 - 4 in Chap ter 1 for the LED ind ic ation of when it is safe to p ull the b oard . 3. Unsnap the sec uring latc h at the b ottom front of the system, and swing downward. 4. Carefully slid e the DEFINITY AUDIX System from the switc h c arrier. Handle with c are: the system weig hs 3.85 p ound s. 5. If you need to rep lac e either of the d isk d rives on the TN568 b oard see ‘‘Disk/MO Drive Rep lac ement Proc ed ures’’ in Chap ter 4. Rep lac e the TN568 using the above step s in reverse order.
SCSI Devices 4-1 Magneto-Optical Drive Problems 4 DEFINITY AUDIX System Maintenance 585-300-121 Issue 1 May 1999 4 SCSI Devices This c hapter lists errors and alarms that may oc c ur to the MO d rive or hard d isk d rive. Refer to the alarm log tab le for rep air p roc ed ures and to the error log tab le to b etter und erstand what eq uip ment errors will trig ger eac h alarm. Magneto-Optical Drive Problems Errors that oc c ur d uring normal MO-drive op eration are rec ord ed in the system error log . Errors d etec ted d uring b ac kg round tests are also rec ord ed in the system error log. These tests are exec uted every hour. They: nDetermine if the d evic e is eq uip ped nDetermine if the d evic e is write-p rotec ted (this p rob lem d oes not c ause an error) nVerify that the MO d rive is read y. Note that the MO d rive c annot b e b usied out. Use the STATUS MO-DISK sc reen to d isp lay the c urrent status of the MO d rive and MO d isk, listed b elow. Bring ing up this screen also invokes a SCSI self- d iag nostic s test of the MO d isk drive and MO d isk.
DEFINITY AUDIX System Maintenance 585-300-121 Issue 1 May 1999 SCSI Devices 4-2 Magneto-Optical Drive Problems 4 Th e STATUS MO-DISK c ommand rep orts the following : nif the MO d rive is eq uip p ed nthe vend or nthe model number nthe vend or’s revision numb er nif the MO d isk is eq uip p ed nif the MO d isk is writing enab led nthe MO disk capacity Refer to Ta b l e 4 - 1 for a list of alarms and repair p roc ed ures ad d ressed to the MO d rive. Perform rep air ac tions one at a time until the p roblem is solved . Alarms ap p ear in the D I SPL AY A L ARM S screen under the resource type: UEQ Uneq uipp ed ISP In Servic e Pend ing . The MO d isk may have just b een ad ded to the system b ut initialization is not yet c omp lete. OOS-D Out Of Servic e d ue to insuffic ient translation information. This implies that the MO d isk is inserted b ut has not yet been ad ded with the ADD MO-DISK sc reen. OOS-F Out of Servic e d ue to a fault. The MO d rive shows an alarm against it. OOS-T Out of Servic e d ue to a test. An MO d rive test is running . ISB In Servic e Busy. The MO d rive is ac tive. ISI In Servic e Id le. The MO d isk has b een ad d ed and is inac tive. MO-DISK Table 4-1. MO-DISK Alarms and Repair Procedures Fault CodeFault DescriptionAlarm LevelError Log ResourceRepair Action 0 SC SI M e d i u m ( b l o c k read /write) failureMINORMO_DISK — Remove the MO disk then add it again. — Ad d the MO d isk with the initialize op tion. — Rep lac e the MO d isk. — Rep lac e the MO d rive. — Rep lac e the TN568. Continued on next page
DEFINITY AUDIX System Maintenance 585-300-121 Issue 1 May 1999 SCSI Devices 4-3 Magneto-Optical Drive Problems 4 Tab le 4-2 lists the MO d isk errors log g ed in the D I SPL AY ERRO RS sc reen. These errors may g enerate the ab ove alarms. 1 Hard ware (d evic e) Fa i lu r eMINORMO_DISK — Test the MO d rive using the STATUS MO-DISK sc reen. — Chec k the c ab les. — Insert another MO d isk. — Rep lac e the MO d rive. — Rep lac e the TN568. 2 Bac kup Job Failed WARNINGMO_DISK — Run a manual b ac kup; — Verify any other alarms for this resourc e typ e (MO_DISK). — Verify that b ac kup s are enab led . — Verify that there is sp ac e on the MO disk. — Run the test MO-DISK c ommand . 3 Corrup t Filesystem WARNINGMO_DISK — Remove and then ad d the MO disk using the REMOVE MO_DISK and ADD MO-DISK INITIALIZE c ommand s. — Rep lac e the MO d isk. Table 4-2. MO Disk Errors Error ResourceError Code DescriptionFault ResourceFault Code SCSI_MO 124 Rec overab le Disk Medium ErrorMO_DISK 0 SCSI_MO 125 Non-rec overab le Disk Med ium ErrorMO_DISK 0 SCSI_MO 126 Remove Disk Command Exec utedMO_DISK 0 SCSI_MO 127 Disk Devic e ErrorMO_DISK 1 SCSI_MO 128 Disk Diag nostic s OK Status MO-d iskMO_DISK 1 SCSI_MO 131 Diagnostic s failed on the DriveMO_DISK 1 SCSI_MO 180 Bad Disk LabelMO_DISK none SCSI_MO 181 A Bac kup Job FailedMO_DISK none Ta b l e 4 - 1 .MO-DISK Alarms and Repair Procedures — Continued Fault CodeFault DescriptionAlarm LevelError Log ResourceRepair Action Continued on next page
DEFINITY AUDIX System Maintenance 585-300-121 Issue 1 May 1999 SCSI Devices 4-4 Magneto-Optical Drive Problems 4 Ta b l e 4 - 3 lists the test MO tests, what is shown on the sc reen when they p ass, fail or ab ort, and p ossib le rep air ac tions. SCSI_MO 182 A Bac kup Job Retry FailedMO_DISK 2 SCSI_MO 185 Corrup t FilesystemMO_DISK 3 SCSI_MO 186 Filesystem okMO_DISK 3 SCSI_MO 195 A Bac kup Job PassedMO_DISK 2 Ta b l e 4 - 3 . Te s t M O R e s u l t s Te s t N a m eTest Result (Passed) Test Result (Failed) Test Result (Abort) Action Chec k MO filesystemP Passed F Ad d mo-d isk initAdd mo-disk with initialize op tion A No mo-disk insertedPut an MO d isk in the MO-d rive. A Ad d mo-disk in progWait until ad d is d one. Chec k status mo-disk until inservic e id le. A Typ e is not Bac kup Remove g eneric MO disk and put in backup MO d isk. A Mo-d isk is write protChange write p rotec tion tab on MO disk. A No sp ac e left Use a d ifferent MO d isk. The test c annot b e run on a full d isk. A Mo-d isk in use Chec k status mo-disk until inservic e id le Table 4-2. MO Disk Errors — Continued Error ResourceError Code DescriptionFault ResourceFault Code
DEFINITY AUDIX System Maintenance 585-300-121 Issue 1 May 1999 SCSI Devices 4-5 Magneto-Optical Drive Problems 4 On-Site Task: MO Disk Replacement The system ad ministrator is req uired to rep lac e the MO d isk. Read /write MOP Passed F Fa i le d A Ad d mo-disk first Ad d mo-disk A Ad d mo-disk in progWait until ad d is d one. Chec k status mo-disk until inservic e id le. A Typ e is not Bac kup Remove g eneric MO disk and put in backup MO d isk. A Mo-d isk is write protChange write p rotec tion tab on MO disk. A No sp ac e left Use a d ifferent MO d isk. The test c annot b e run on a full d isk. A Mo-d isk in use Chec k status mo-disk until inservic e id le Procedure 1. Enter remove MO-disk to unloc k and unload the MO d isk. 2. Remove the MO d isk from the d rive. Rep lac e it with a new MO d isk. 3. Enter add MO-disk . This c lears any existing alarms, load s the MO d isk, and ad d s the d efault volume lab el. Op tionally, the system administrator can add initialize to the add MO-disk c ommand . This will remove all d ata on the disk while retaining the volume lab el. Ta b l e 4 - 3 . Te s t M O R e s u l t s Te s t N a m eTest Result (Passed) Test Result (Failed) Test Result (Abort) Action
DEFINITY AUDIX System Maintenance 585-300-121 Issue 1 May 1999 SCSI Devices 4-6 Hard Disk Problems 4 Hard Disk Problems Except for normal inline error detection, and periodic background tests, which oc c ur every 30 sec ond s, no tests are manually p erformed on the hard d isk d rive using sc reens. The d isk drive c annot b e b usied out. Use the STATUS DISK c ommand to d isp lay the c urrent values of the d isk d rive, listed b elow. Bring ing up this sc reen will also invoke a d isk b ac kg round test. Refer to Ta b l e 4 - 4, Disk Alarms and Repair Procedures, for a list of alarms and rep air p roc ed ures ad d ressed to the d isk d rive. Alarms ap pear in the D ISPL AY ALARMS sc reen und er the resourc e typ e: UEQ Unequipped OOS-F Out Of Servic e Fault. The d isk shows an alarm ag ainst it. ISB In Servic e Busy. The d isk is ac tive. DISK Table 4-4. Disk Alarms and Repair Procedures Fault CodeFault DescriptionAlarm LevelError Log ResourceRepair Action 0SC SI m e d i u m (block read/write) failure.MINORSCSI_HD— Look in the error log for messages log ged against resourc e typ e DISK using c odes 124 or 125 (these ind ic ate the same bloc k g iven in the field aux2 ). Manually reassig n every suc h bloc k using the Stand alone Utilities. — If manual reassignment fails or bloc k errors reoc c ur, rep lac e the d isk and restore g eneric and c ustomer d ata. 1Devic e (hard ware) failure.MAJORSCSI_HD— Test the disk b y invoking the STATUS DISK sc reen. — Chec k the c ab les to see that they are firmly inserted into the b oard and the disk d rive, and that there are no broken lead s. — If d evic e errors still oc c ur, rep lac e the d isk drive.
DEFINITY AUDIX System Maintenance 585-300-121 Issue 1 May 1999 SCSI Devices 4-7 Hard Disk Problems 4 Tab le 4-5, Disk Drive Errors, lists the errors logg ed in the D ISPL AY ERRO RS sc reen. These errors may g enerate the ab ove alarms. Table 4-5. Disk Drive Errors Error ResourceError Code DescriptionFault ResourceFault Code SCSI_HD 80 Initialization MP 57 ab orted (aud its d isk files)DISK 1 SCSI_HD 81 Diag nostic MP 57 failed (aud its d isk files)DISK 1 SCSI_HD 81 Initialization MP 57 failed (audits disk files)DISK 1 SCSI_HD 81 Periodic MP 57 failed (aud its d isk files)DISK 1 SCSI_HD 124 Rec overab le d isk med ium error DISK 0 SCSI_HD 125 Non-rec overab le d isk medium error DISK 0 SCSI_HD 126 Remove d isk c ommand exec uted DISK 0 SCSI_HD 127 Disk d evic e error DISK 1 SCSI_HD 128 Disk d iagnostic s OK (status d isk) DISK 1 SCSI_HD 131 Diag nostic s failed on a d rive DISK 1
DEFINITY AUDIX System Maintenance 585-300-121 Issue 1 May 1999 SCSI Devices 4-8 Disk/MO Drive Replacement Procedures 4 Disk/MO Drive Replacement Procedures Refer to Fi g u re 4 -1, Sid e View of DEFINITY AUDIX System, when replacing the disk or MO drive. Figure 4-1. Side View of DEFINITY AUDIX System Emer Reset Shutdown ckdx568e LJK 020599 Hard disk drive standoffs (4)Magneto-optical disk drive LEDs Securing latch MO disk drive standoffs (4) Hard drive power cable Hard drive SCSI cable MO power cable MO SCSI cableS e ag a te MEDALISTMODEL PAR T NUMBER CONFIGURA TION LEVEL SERIAL NUMBERST34520W Hard disk drive