    Have a look at the manual Lucent Technologies Definity Audix System Release 4.0 Maintenance Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							DEFINITY AUDIX System Maintenance  585-300-121  Issue 1
    May 1999
    TN568 Circuit Pack 
    3-15 System Time 
    3
    Tab le 3-8, Sy st e m  Ti m e  Er ro rs, lists the errors log g ed in the D ISPLAY ERRORS sc reen. 
    These errors may g enerate the ab ove alarms. 
    Table 3-8. System Time Errors
    Error
    ResourceError
    Code DescriptionFault
    ResourceFault
    Code
    SYS_TIME 80
    Initialization MP 53 ab orted (valid ates system time)SYS_TIME 0
    SYS_TIME 81
    Diag nostic  MP 31 failed (c hec ks switc h time ag ainst system 
    clock)SYS_TIME 2
    SYS_TIME 81
    Diag nostic  MP 31 failed (c hec ks switc h time ag ainst system 
    clock)SYS_TIME 3
    SYS_TIME 81
    Diag nostic  MP 85 failed (restart system in OA&M mode)SYS_TIME 0
    SYS_TIME 81
    Initialization MP 53 failed  (validates system time)SYS_TIME 0
    SYS_TIME 81
    Long  demand  seq uenc e MP 31 failed (c hec ks switc h time 
    ag ainst system c loc k)SYS_TIME 2
    SYS_TIME 81
    Period ic  MP 31 failed (c hec ks switc h time ag ainst system 
    clock)SYS_TIME 2
    SYS_TIME 81
    Short d emand seq uenc e MP 31 failed  (c hec ks switc h time 
    ag ainst system c loc k)SYS_TIME 2
    SYS_TIME 81
    Sync hronize d emand MP 32 failed  (sync hronizes switc h time 
    with system c loc k)SYS_TIME 2
    SYS_TIME 244
    c hang e switc h time-zone sc reen exec uted  SYS_TIME 3
    SYS_TIME 245
    Switc h c hang ed  its time SYS_TIME 3
    SYS_TIME 246
    g et_date() c all failed  SYS_TIME 1
    SYS_TIME 247
    get_date() call passed SYS_TIME 1 
    						
    							DEFINITY AUDIX System Maintenance  585-300-121  Issue 1
    May 1999
    TN568 Circuit Pack 
    3-16 TN568 Board Replacement 
    3
    TN568 Board Replacement
    Follow the step s b elow to rep lac e the TN568. 
    !WARNING:
    Static  elec tric ity c an b e destruc tive to system p arts. Use an anti-static  wrist 
    strap  whenever removing  or installing  a DEFINITY AUDIX System. Also use 
    an anti-static  mat when taking  the system ap art to rep lac e the c irc uit p ac k 
    or storag e d evic es.
    1. Ensure that the c ustomer knows you will b e p owering  d own the system 
    and  d isrupting  servic e. 
    2. If it is not alread y shut d own, b ring the system to the shutd own state with 
    the 
    RESET SYSTEM SHUTDOWN sc reen, or the shutd own button on the fac ep late. 
    See Ta b l e  1 - 4 in Chap ter 1 for the LED ind ic ation of when it is safe to p ull 
    the b oard .
    3. Unsnap  the sec uring latc h at the b ottom front of the system, and  swing  
    downward.
    4. Carefully slid e the DEFINITY AUDIX System from the switc h c arrier. 
    Handle with c are: the system weig hs 3.85 p ound s.
    5. If you need to rep lac e either of the d isk d rives on the TN568 b oard  see 
    ‘‘Disk/MO Drive Rep lac ement Proc ed ures’’ in Chap ter 4.
    Rep lac e the TN568 using  the above step s in reverse order.  
    						
    							SCSI Devices 
    4-1 Magneto-Optical Drive Problems 
    4
    DEFINITY AUDIX System Maintenance  585-300-121  Issue 1
    May 1999
    4
    SCSI Devices
    This c hapter lists errors and  alarms that may oc c ur to the MO d rive or hard  d isk 
    d rive. Refer to the alarm log  tab le for rep air p roc ed ures and  to the error log  tab le 
    to b etter und erstand  what eq uip ment errors will trig ger eac h alarm. 
    Magneto-Optical Drive Problems
    Errors that oc c ur d uring  normal MO-drive op eration are rec ord ed  in the system 
    error log . 
    Errors d etec ted  d uring  b ac kg round  tests are also rec ord ed in the system error 
    log. These tests are exec uted  every hour. They: 
    nDetermine if the d evic e is eq uip ped  
    nDetermine if the d evic e is write-p rotec ted  (this p rob lem d oes not c ause an 
    error) 
    nVerify that the MO d rive is read y.
    Note that the MO d rive c annot b e b usied  out.
    Use the 
    STATUS MO-DISK sc reen to d isp lay the c urrent status of the MO d rive and  
    MO d isk, listed  b elow. Bring ing  up  this screen also invokes a SCSI self-
    d iag nostic s test of the MO d isk drive and  MO d isk. 
    						
    							DEFINITY AUDIX System Maintenance  585-300-121  Issue 1
    May 1999
    SCSI Devices 
    4-2 Magneto-Optical Drive Problems 
    4
    Th e  STATUS MO-DISK c ommand  rep orts the following :
    nif the MO d rive is eq uip p ed
    nthe vend or
    nthe model number
    nthe vend or’s revision numb er
    nif the MO d isk is eq uip p ed
    nif the MO d isk is writing  enab led
    nthe MO disk capacity
    Refer to Ta b l e  4 - 1 for a list of alarms and  repair p roc ed ures ad d ressed  to the MO 
    d rive. Perform rep air ac tions one at a time until the p roblem is solved . Alarms 
    ap p ear in the 
    D I SPL AY A L ARM S screen under the resource type:
    UEQ
    Uneq uipp ed
    ISP
    In Servic e Pend ing . The MO d isk may have just b een ad ded  to the system b ut 
    initialization is not yet c omp lete.
    OOS-D
    Out Of Servic e d ue to insuffic ient translation information. This implies that the MO 
    d isk is inserted  b ut has not yet been ad ded  with the 
    ADD MO-DISK sc reen.
    OOS-F
    Out of Servic e d ue to a fault. The MO d rive shows an alarm against it.
    OOS-T
    Out of Servic e d ue to a test. An MO d rive test is running .
    ISB
    In Servic e Busy. The MO d rive is ac tive.
    ISI
    In Servic e Id le. The MO d isk has b een ad d ed and  is inac tive.
    MO-DISK
    Table 4-1. MO-DISK Alarms and Repair Procedures 
    Fault
    CodeFault
    DescriptionAlarm
    LevelError Log
    ResourceRepair
    Action
    0
    SC SI  M e d i u m  ( b l o c k  
    read /write) failureMINORMO_DISK
    — Remove the MO disk then add  
    it again.
    — Ad d  the MO d isk with the 
    initialize op tion.
    — Rep lac e the MO d isk.
    — Rep lac e the MO d rive.
    — Rep lac e the TN568.
    Continued on next page 
    						
    							DEFINITY AUDIX System Maintenance  585-300-121  Issue 1
    May 1999
    SCSI Devices 
    4-3 Magneto-Optical Drive Problems 
    4
    Tab le 4-2 lists the MO d isk errors log g ed  in the D I SPL AY ERRO RS sc reen. These errors 
    may g enerate the ab ove alarms. 
    1
    Hard ware (d evic e) 
    Fa i lu r eMINORMO_DISK
    — Test the MO d rive using the 
    STATUS MO-DISK sc reen.
    — Chec k the c ab les.
    — Insert another MO d isk.
    — Rep lac e the MO d rive.
    — Rep lac e the TN568.
    2
    Bac kup Job  Failed WARNINGMO_DISK
    — Run a manual b ac kup;
    — Verify any other alarms for this 
    resourc e typ e (MO_DISK).
    — Verify that b ac kup s are 
    enab led .
    — Verify that there is sp ac e on the 
    MO disk.
    — Run the test MO-DISK 
    c ommand .
    3
    Corrup t Filesystem WARNINGMO_DISK
    — Remove and  then ad d  the MO 
    disk using the REMOVE 
    MO_DISK and  ADD MO-DISK 
    INITIALIZE c ommand s.
    — Rep lac e the MO d isk.
    Table 4-2.  MO Disk Errors
    Error
    ResourceError
    Code DescriptionFault
    ResourceFault
    Code
    SCSI_MO 124
    Rec overab le Disk Medium ErrorMO_DISK 0
    SCSI_MO 125
    Non-rec overab le Disk Med ium ErrorMO_DISK 0
    SCSI_MO 126
    Remove Disk Command  Exec utedMO_DISK 0
    SCSI_MO 127
    Disk Devic e ErrorMO_DISK 1
    SCSI_MO 128
    Disk Diag nostic s OK
    Status MO-d iskMO_DISK 1
    SCSI_MO 131
    Diagnostic s failed  on the DriveMO_DISK 1
    SCSI_MO 180
    Bad  Disk LabelMO_DISK none
    SCSI_MO 181
    A Bac kup Job  FailedMO_DISK none
    Ta b l e  4 - 1 .MO-DISK Alarms and Repair Procedures  — Continued
    Fault
    CodeFault
    DescriptionAlarm
    LevelError Log
    ResourceRepair
    Action
    Continued on next page 
    						
    							DEFINITY AUDIX System Maintenance  585-300-121  Issue 1
    May 1999
    SCSI Devices 
    4-4 Magneto-Optical Drive Problems 
    4
    Ta b l e  4 - 3 lists the test MO tests, what is shown on the sc reen when they p ass, fail 
    or ab ort, and  p ossib le rep air ac tions. 
    SCSI_MO 182
    A Bac kup Job  Retry FailedMO_DISK 2
    SCSI_MO 185
    Corrup t FilesystemMO_DISK 3
    SCSI_MO 186
    Filesystem okMO_DISK 3
    SCSI_MO 195
    A Bac kup Job  PassedMO_DISK 2
    Ta b l e  4 - 3 . Te s t  M O  R e s u l t s
    Te s t  N a m eTest Result 
    (Passed) Test Result (Failed) Test Result (Abort) Action
    Chec k MO 
    filesystemP Passed
    F Ad d  mo-d isk initAdd mo-disk
     with 
    initialize op tion
    A No mo-disk 
    insertedPut an MO d isk in the 
    MO-d rive.
    A Ad d mo-disk in 
    progWait until ad d  is d one. 
    Chec k status mo-disk
     
    until inservic e id le.
    A Typ e is not Bac kup Remove g eneric  MO 
    disk and put in backup 
    MO d isk.
    A Mo-d isk is write 
    protChange write p rotec tion 
    tab on MO disk.
    A No sp ac e left Use a d ifferent MO d isk. 
    The test c annot b e run 
    on a full d isk.
    A Mo-d isk in use Chec k status mo-disk
     
    until inservic e id le
    Table 4-2.  MO Disk Errors — Continued
    Error
    ResourceError
    Code DescriptionFault
    ResourceFault
    Code 
    						
    							DEFINITY AUDIX System Maintenance  585-300-121  Issue 1
    May 1999
    SCSI Devices 
    4-5 Magneto-Optical Drive Problems 
    4
    On-Site Task: MO Disk Replacement
    The system ad ministrator is req uired  to rep lac e the MO d isk. 
    Read /write MOP Passed
    F Fa i le d
    A Ad d mo-disk first Ad d mo-disk
    A Ad d mo-disk in 
    progWait until ad d  is d one. 
    Chec k status mo-disk 
    until inservic e id le.
    A Typ e is not Bac kup Remove g eneric  MO 
    disk and put in backup 
    MO d isk.
    A Mo-d isk is write 
    protChange write p rotec tion 
    tab on MO disk.
    A No sp ac e left Use a d ifferent MO d isk. 
    The test c annot b e run 
    on a full d isk.
    A Mo-d isk in use Chec k status mo-disk
     
    until inservic e id le
    Procedure
    1. Enter remove MO-disk
     to unloc k and  unload  the MO d isk.
    2. Remove the MO d isk from the d rive. Rep lac e it with a new MO d isk. 
    3. Enter add MO-disk
    . This c lears any existing  alarms, load s the MO 
    d isk, and  ad d s the d efault volume lab el. Op tionally, the system 
    administrator can add initialize
     to the add MO-disk
     c ommand . This 
    will remove all d ata on the disk while retaining  the volume lab el.
    Ta b l e  4 - 3 . Te s t  M O  R e s u l t s
    Te s t  N a m eTest Result 
    (Passed) Test Result (Failed) Test Result (Abort) Action 
    						
    							DEFINITY AUDIX System Maintenance  585-300-121  Issue 1
    May 1999
    SCSI Devices 
    4-6 Hard Disk Problems 
    4
    Hard Disk Problems
    Except for normal inline error detection, and periodic background tests, which 
    oc c ur every 30 sec ond s, no tests are manually p erformed on the hard  d isk d rive 
    using sc reens. The d isk drive c annot b e b usied  out. 
    Use the 
    STATUS DISK c ommand  to d isp lay the c urrent values of the d isk d rive, 
    listed  b elow. Bring ing up  this sc reen will also invoke a d isk b ac kg round  test. 
    Refer to Ta b l e  4 - 4, Disk Alarms and Repair Procedures, for a list of alarms and  
    rep air p roc ed ures ad d ressed  to the d isk d rive. Alarms ap pear in the 
    D ISPL AY 
    ALARMS
     sc reen und er the resourc e typ e:
    UEQ Unequipped
    OOS-F Out Of Servic e Fault.  The d isk shows an alarm ag ainst it.
    ISB In Servic e Busy. The d isk is ac tive.
    DISK
    Table 4-4. Disk Alarms and Repair Procedures
    Fault
    CodeFault
    DescriptionAlarm
    LevelError Log
    ResourceRepair
    Action
    0SC SI m e d i u m  
    (block 
    read/write) 
    failure.MINORSCSI_HD— Look in the error log  for messages log ged  
    against resourc e typ e DISK using  c odes 124 
    or 
    125 (these ind ic ate the same bloc k g iven in 
    the field aux2
    ). Manually reassig n every suc h 
    bloc k using  the Stand alone Utilities.
    — If manual reassignment fails or bloc k errors 
    reoc c ur, rep lac e the d isk and  restore g eneric  
    and c ustomer d ata.
    1Devic e 
    (hard ware) 
    failure.MAJORSCSI_HD— Test the disk b y invoking  the STATUS DISK 
    sc reen.
    — Chec k the c ab les to see that they are firmly 
    inserted into the b oard  and  the disk d rive, and  
    that there are no broken lead s.
    — If d evic e errors still oc c ur, rep lac e the d isk 
    drive. 
    						
    							DEFINITY AUDIX System Maintenance  585-300-121  Issue 1
    May 1999
    SCSI Devices 
    4-7 Hard Disk Problems 
    4
    Tab le 4-5, Disk Drive Errors, lists the errors logg ed in the D ISPL AY ERRO RS sc reen. 
    These errors may g enerate the ab ove alarms. 
    Table 4-5. Disk Drive Errors
    Error
    ResourceError
    Code DescriptionFault
    ResourceFault
    Code
    SCSI_HD 80
    Initialization MP 57 ab orted (aud its d isk files)DISK 1
    SCSI_HD 81
    Diag nostic  MP 57 failed  (aud its d isk files)DISK 1
    SCSI_HD 81
    Initialization MP 57 failed  (audits disk files)DISK 1
    SCSI_HD 81
    Periodic  MP 57 failed  (aud its d isk files)DISK 1
    SCSI_HD 124
    Rec overab le d isk med ium error DISK 0
    SCSI_HD 125
    Non-rec overab le d isk medium error DISK 0
    SCSI_HD 126
    Remove d isk c ommand exec uted  DISK 0
    SCSI_HD 127
    Disk d evic e error DISK 1
    SCSI_HD 128
    Disk d iagnostic s OK (status d isk) DISK 1
    SCSI_HD 131
    Diag nostic s failed  on a d rive DISK 1 
    						
    							DEFINITY AUDIX System Maintenance  585-300-121  Issue 1
    May 1999
    SCSI Devices 
    4-8 Disk/MO Drive Replacement Procedures 
    4
    Disk/MO Drive Replacement 
    Procedures
    Refer to Fi g u re  4 -1, Sid e View of DEFINITY AUDIX System, when replacing the 
    disk or MO drive.
    Figure 4-1. Side View of DEFINITY AUDIX System
    Emer Reset
    Shutdown
    ckdx568e LJK 020599
    Hard disk drive
    standoffs (4)Magneto-optical
    disk drive
    LEDs
    Securing
    latch
    MO disk drive
    standoffs (4) Hard drive
    power cable
    Hard drive
    SCSI cable
    MO
    power cable
    MO SCSI cableS
    e
    ag
    a
    te
    MEDALISTMODEL
    PAR
    T NUMBER
    CONFIGURA
    TION LEVEL
    SERIAL NUMBERST34520W
    Hard disk
    drive 
    						