    Have a look at the manual Lucent Technologies CentreVu Call Management System Release 3 Version 8 Software Installation And Setup Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							  Installing Software and Setting Up CMS CentreVu®  CMS R3V8 Software Installation and Setup
    Installing DiskSuite2-93
    10. To create and mount /cms, enter:
    mkdir /cms
    mount /cms
    11. Enter: eject cdrom
    Configuring 
    DiskSuite on a 
    mirrored system
    2
    This procedure configures DiskSuite on a unmirrored Enterprise 3000 or 
    3500 system.
    1. Enter:
    stty erase 
    
    (where  means “press/hold Control as you press H”)
    The stty command sets up your backspace key as an actual 
    backspace. If you do not enter this command, you will have to use 
    the Delete key as a backspace.
    2. Enter the following commands:
    3. To alter the path, enter:
    export PATH=$PATH:/usr/opt/SUNWmd/sbin/:/olds
    4. Enter:
    olds -mirrored -check_disks
    5. Enter:
    olds -mirrored -mk_files
    6. Enter:
    olds -mirrored -metadbs
    7. Enter:
    olds -mirrored -setroot
    mkdir /olds 
    cp /cdrom/cdrom0/cms/reloc/rdonly/olds_install/* /olds
    cd /olds
    chmod +x /olds/olds 
    						
    							  Installing Software and Setting Up CMS CentreVu®  CMS R3V8 Software Installation and Setup
    Installing DiskSuite2-94
    8. To reboot, enter:
    /usr/sbin/shutdown -y -g0 -i0
    When the ok prompt is displayed, enter:
    boot -r 
    When the reboot is finished, log in as root. 
    9. To setup the /cms metadevices, enter the following commands: 
    export PATH=$PATH:/olds:/usr/opt/SUNWmd/sbin
    olds -mirrored -setup
    The system should respond:
    Success, /cms mirrored successfully
    10. Enter the following commands:
    mkdir /cms
    mount /cms
    11. To verify the DiskSuite configuration, enter:
    df -k
    The output format should be similar to the following example:
    To confirm that DiskSuite has administered all of the disks, verify 
    that the /dev/md/dsk/d21 line is present in the output. Filesystem kbytes used  avail capacity Mounted
    /dv/md/dsk/d13 xxxxx  xxxxx xxxxx xx% /
    proc xxxxx  xxxxx xxxxx xx% /proc
    fd xxxxx  xxxxx xxxxx xx% /dev/fd
    /dev/md/dsk/d21 xxxxx  xxxxx xxxxx xx% /cms 
    						
    							  Installing Software and Setting Up CMS CentreVu®  CMS R3V8 Software Installation and Setup
    Installing DiskSuite2-95
    Checking for Disk 
    Recognition Errors
    2
    The procedures in the section will help you to diagnose problems with 
    unrecognized disk drives. This procedure is different for the different 
    hardware platforms.
    Use this procedure only if the DiskSuite scripts indicate there is a 
    disk recognition error. Do NOT do this as part of the normal 
    installation procedure.
    Disk Recognition 
    Errors on 
    Ultra 52
    1. Reboot the system with an init 0 command. The system reboots 
    and displays the ok prompt.
    2. Turn off the system unit.
    3. Turn off the system monitor.
    4. Turn off all external devices (such as disk drives, tapes drives, and 
    NTSs) starting with the device closest to the system unit and 
    working toward the farthest device.
    5. Check all external device connections to verify that they are secure. 
    Also check the SCSI IDs on the disk drives to verify that no two 
    drives have the same ID.
    6. Turn on the power to the system units in the opposite order in which 
    you powered them off. That is, power on the external devices first, 
    working your way toward the system unit. Then power on the 
    system unit itself and, finally, the system monitor.
    When you power on the system unit, the system begins to boot. 
    Interrupt the boot by pressing the   and   keys simultaneously. 
    The system responds
     with the ok prompt.
    7. Enter:
    setenv auto-boot? false
    This keeps the system from rebooting when you do a reset.
    8. Enter:
    reset-all
    The system resets and responds with the ok prompt. 
    !CAUTION: 
    						
    							  Installing Software and Setting Up CMS CentreVu®  CMS R3V8 Software Installation and Setup
    Installing DiskSuite2-96
    9. To verify that the system sees all IDE devices, enter:
    probe-ide
    The program responds similar to the following:
    10. To verify that the system sees all SCSI devices, enter:
    probe-scsi-all
    The program responds similar to the following:
    11. Verify that all of the disk drives are recognized. If the devices are still 
    not recognized, see 
    CentreVu® CMS R3V8 Hardware Maintenance 
    and Troubleshooting
     (585-210-919) for more information.
    12. When you have verified that the system is recognizing all of its disk 
    drives, enter:
    setenv auto-boot? true
    If you fail to enter this command, future reboots will stop at the 
    boot prompt instead of proceeding through the normal boot-up.
    Device 0 ( Primary Master )
    ATA Model: ST34342A
    Device 1 ( Primary Slave )
    Not present
    Device 2 ( Secondary Master )
    Removeable ATAPI Model: CRD-8240B
    Device 3 ( Secondary Slave )
    Removeable ATAPI Model:
    /pci@1f,0/pci@1/pci@1/SUNW,isptwo@4
    Target 0
    Unit 0 Disk QUANTUM VK4550J SUN4.2G8610
    Target 4
    Unit 0 Removeable Tape TANDBERG SLR5 0906
    !CAUTION: 
    						
    							  Installing Software and Setting Up CMS CentreVu®  CMS R3V8 Software Installation and Setup
    Installing DiskSuite2-97
    13. Enter boot -r. The system reboots.
    14. Log in as 
    root.
    15. Repeat the procedures described in “Configuring DiskSuite on an 
    unmirrored system” on Page 2-88, or “Configuring DiskSuite on a 
    mirrored system” on Page 2-93.
    Disk Recognition 
    Errors on 
    Enterprise35002
    1. Reboot the system with an init 0 command. The system reboots 
    and displays the ok prompt.
    2. Turn off the system unit.
    3. Turn off the system monitor.
    4. Turn off all external devices (such as disk drives, tapes drives, and 
    NTSs) starting with the device closest to the system unit and 
    working toward the farthest device.
    5. Check all external device connections to verify that they are secure. 
    Also check the SCSI IDs on the disk drives to verify that no two 
    drives have the same ID.
    6. Turn on the power to the system units in the opposite order in which 
    you powered them off. That is, power on the external devices first, 
    working your way toward the system unit. Then power on the 
    system unit itself and, finally, the system monitor.
    When you power on the system unit, the system begins to boot. 
    Interrupt the boot by pressing the Stop and A keys simultaneously. 
    The system responds
     with the ok prompt.
    7. Enter the following:
    setenv auto-boot? false
    This keeps the system from rebooting when you do a reset.
    8. Enter the following:
    reset-all
    The system resets and responds with the ok prompt.  
    						
    							  Installing Software and Setting Up CMS CentreVu®  CMS R3V8 Software Installation and Setup
    Installing DiskSuite2-98
    9. To verify that the system sees all SCSI devices, enter the following:
    probe-scsi-all
    The program responds similar to the following:
    10. Verify that all of the SCSI devices are recognized. If the devices are 
    still not recognized, see 
    CentreVu® CMS Sun® Enterprise™ 3500 
    Computer Maintenance and Troubleshooting
     (585-215-875) for 
    more information.
    11. To verify that the system sees all the fiber channel disk drives, enter:
    probe-fcal-all
    The program responds similar to the following:
    12. Verify that all of the fiber channel disk drives are recognized. If the 
    disk drives are still not recognized, see 
    CentreVu® CMS Sun® 
    Enterprise™ 3500 Computer Maintenance and Troubleshooting
     
    (585-215-875) for more information.
    /sbus@3,0/SUNW,fas@3,8800000
    Target 5
    Unit 0 Removeable Tape EXABYTE EXB-89008E030203V37f
    0060055614
    Target 6
    Unit 0 Removeable Read Only device TOSHIBA
    XM6201TASUN32XCD110312/12/97
    /sbus@2,0/SUNW,socal@d,10000/sf@1,0
    /sbus@2,0/SUNW,socal@d,10000/sf@0,0
    WWN 20050800209a80fe Loopid 1
    WWN 21000020370e7255 Loopid ef
    Disk SEAGATE ST19171FCSUN9.06117E9822U939 
    						
    							  Installing Software and Setting Up CMS CentreVu®  CMS R3V8 Software Installation and Setup
    Installing DiskSuite2-99
    13. When you have verified that the system is recognizing all of its 
    devices, enter:
    setenv auto-boot? true
    If you fail to enter this command, future reboots will stop at the 
    boot prompt instead of proceeding through the normal boot-up.
    14. Enter boot -r. The system reboots.
    15. Log in as 
    root.
    16. Repeat the procedures described in “Configuring DiskSuite on an 
    unmirrored system” on Page 2-88” or “Configuring DiskSuite on a 
    mirrored system” on Page 2-93.
    Disk Recognition 
    Errors on 
    Enterprise30002
    1. Reboot the system with an init 0 command. The system reboots 
    and displays the ok prompt.
    2. Turn off the system unit.
    3. Turn off the system monitor.
    4. Turn off all external devices (such as disk drives, tapes drives, and 
    NTSs) starting with the device closest to the system unit and 
    working toward the farthest device.
    5. Check all external device connections to verify that they are secure. 
    Also check the SCSI IDs on the disk drives to verify that no two 
    drives have the same ID.
    6. Turn on the power to the system units in the opposite order in which 
    you powered them off. That is, power on the external devices first, 
    working your way toward the system unit. Then power on the 
    system unit itself and, finally, the system monitor.
    When you power on the system unit, the system begins to boot. 
    Interrupt the boot by pressing the   and   keys simultaneously. 
    The system responds
     with the ok prompt.
    !CAUTION: 
    						
    							  Installing Software and Setting Up CMS CentreVu®  CMS R3V8 Software Installation and Setup
    Installing DiskSuite2-100
    7. Enter:
    setenv auto-boot? false
    This keeps the system from rebooting when you do a reset.
    8. Enter:
    reset-all
    The system resets and responds with the ok prompt. 
    9. To verify that the system sees all SCSI devices, enter the following:
    probe-scsi-all
    The program responds similar to the following:
    10. Verify that all of the disk drives are recognized. If the devices are still 
    not recognized, see 
    CentreVu® CMS Hardware Maintenance and 
    Troubleshooting
     (585-215-861) for more information.
    When you have verified that the system is recognizing all of its disk 
    drives, enter the following:
    setenv auto-boot? true
    If you fail to enter this command, future reboots will stop at the 
    boot prompt instead of proceeding through the normal boot-up.
    /iommu@f,e0000000/[email protected]/esp@3,200000
    Target 1
    Unit 0 Disk SEAGATE ST14801 SUN04246266 Copyright (C) 1991
    Target 3
    Unit 0 Disk SEAGATE ST14801 SUN04246266 Copyright (C) 1991
    . . . . .
    . . . . .
    Target 6
    Unit 0 Disk Removable Read Only Device SONY CD-ROM CDU-8012
    !CAUTION: 
    						
    							  Installing Software and Setting Up CMS CentreVu®  CMS R3V8 Software Installation and Setup
    Installing DiskSuite2-101
    11. Enter boot -r. The system reboots.
    12. Log in as 
    root.
    13. Repeat the procedures described in “Configuring DiskSuite on an 
    unmirrored system” on Page 2-88” or “Configuring DiskSuite on a 
    mirrored system” on Page 2-93.
    Disk Recognition 
    Errors on 
    SPARCserver2
    1. Reboot the system with an init 0 command. The system reboots 
    and displays the ok prompt.
    2. Turn off the system unit.
    3. Turn off the system monitor.
    4. Turn off all external devices (such as disk drives, tapes drives, and 
    NTSs) starting with the device closest to the system unit and 
    working toward the farthest device.
    5. Check all external device connections to verify that they are secure. 
    Also check the SCSI IDs on the disk drives to verify that no two 
    drives have the same ID.
    6. Turn on the power to the system units in the opposite order in which 
    you powered them off. That is, power on the external devices first, 
    working your way toward the system unit. Then power on the 
    system unit itself and, finally, the system monitor.
    When you power on the system unit, the system begins to boot. 
    Interrupt the boot by pressing the   and   keys simultaneously. 
    The system responds
     with the ok prompt.
    7. Enter:
    setenv auto-boot? false
    This keeps the system from rebooting when you do a reset. 
    						
    							  Installing Software and Setting Up CMS CentreVu®  CMS R3V8 Software Installation and Setup
    Installing DiskSuite2-102
    8. Enter:
    reset
    The system resets and responds with the ok prompt. 
    9. To verify that the system sees all SCSI devices, enter the following:
    probe-scsi-all
    The program responds similar to the following:
    10. Verify that all of the disk drives are recognized. If the devices are still 
    not recognized, see 
    CentreVu® CMS R3V8 Hardware Maintenance 
    and Troubleshooting
     (585-210-919) for more information.
    11. When you have verified that the system is recognizing all of its disk 
    drives, enter the following:
    setenv auto-boot? true
    If you fail to enter this command, future reboots will stop at the 
    boot prompt instead of proceeding through the normal boot-up.
    12. Enter boot -r. The system reboots.
    13. Log in as 
    root.
    14. Repeat the procedures described in “Configuring DiskSuite on an 
    unmirrored system” on Page 2-88” or “Configuring DiskSuite on a 
    mirrored system” on Page 2-93.
    /iommu@0,10000000/sbus@0,10001000/espdma@5,8400000/esp@5,8800000
    Target 3
    Unit 0 Disk IBM DORS32160SUN2.1GWA7A96210Z5218
    0933 000116
    Target 4 46H6081 07H1118
    Unit 0 Removeable Tape TANDBERG TDC 4200 =07:08CREATED053195
    Target 6
    Unit 0 Removeable Read Only device TOSHIBA XM5401...
    !CAUTION: 
    						