Home > Lucent Technologies > Communications System > Lucent Technologies CentreVu Call Management System Release 3 Version 8 Software Installation And Setup Manual

Lucent Technologies CentreVu Call Management System Release 3 Version 8 Software Installation And Setup Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Lucent Technologies CentreVu Call Management System Release 3 Version 8 Software Installation And Setup Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 413 Lucent Technologies manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							  Installing Software and Setting Up CMS CentreVu®  CMS R3V8 Software Installation and Setup
    Installing INFORMIX2-83
    17. Press Enter. The program responds:
    18. Enter 4 to exit the installation program. The program responds:
    19. Enter eject cdrom to eject the CD-ROM from the computer.
    20. Remove the CD-ROM from the disk tray and place the CD-ROM 
    back in its case. 
      INFORMIX INTERNATIONAL LANGUAGE SUPPLEMENT (ILS)
                        INSTALLER FOR ALL UNIX PLATFORMS
     
    Choose install type:
        (1) Express Install
              Installs everything relating to one or more languages.
     
        (2) Custom Install
              You specify exactly what you want to install.
    Other options:   
        (3) Help
              Displays information on the contents of this package, 
    and explains the options on this screen.
        (4) Exit
              Exit this installer.
     
    (E)nglish (D)eutsch/German (F)rancais/French e(S)panol/Spanish
    (R)ussian (P)oliski/Polish (C)ekych/Czech    s(L)ovych/Slovak
     
    Enter one choice, and hit ENTER:
      Exiting the International Language Supplement installer. 
    						
    							  Installing Software and Setting Up CMS CentreVu®  CMS R3V8 Software Installation and Setup
    Installing DiskSuite2-84
    Installing DiskSuite2
    Installing DiskSuite includes the following:
    lInstalling Solstice DiskSuite software
    lInstalling Sun Solaris patches
    lSetting up Solstice DiskSuite.
    Installing the 
    Solstice 
    DiskSuite 
    Software2
    Overview2The Solstice DiskSuite software package allows the disks of the system 
    to be managed as if they were a single file system.
     Platform 
    Considerations
    2
    lAll platforms.
    Prerequisites2lThe Solaris 7 operating system must be installed.
    lVerify that you are logged in as root at the console.
    lObtain the “Solaris Easy Access Server 2.0” CD.
    lYou must have partitioned the hard disks for the Solstice DiskSuite 
    system as specified in “Partitioning the Hard Disks” on Page 2-18.
    Procedure21. Load the “Solaris Easy Access Server 2.0 CD into the CD-ROM 
    drive.
    2. Enter cd to move to the root directory. 
    						
    							  Installing Software and Setting Up CMS CentreVu®  CMS R3V8 Software Installation and Setup
    Installing DiskSuite2-85
    3. After about 15 seconds, enter mount to verify the name of the 
    CD-ROM. The program responds with a list of devices and file 
    systems currently mounted. The last line should display the installed 
    CD as shown below:
    4. Enter:    
    The program responds:
    5. Enter y. The program responds:
    6. Enter eject cd 
    .
    .
    /cdrom/solaris_easy_access_server_2_0 on /vol/dsk/c0t2d0/disk
     read only on (
    current date and time)
    /usr/sbin/pkgadd -d /cdrom/cdrom0/products/DiskSuite_4.2/sparc SUNWmd
    This package contains scripts which will be executed with 
    super-user permissions duringthe process of installing this 
    package.
    Do you want to continue with installation of 
     [y. n, ?]
    Installing Sosltice DiskSuite as 
    ....
    ##Installation of was successful.  
    						
    							  Installing Software and Setting Up CMS CentreVu®  CMS R3V8 Software Installation and Setup
    Installing DiskSuite2-86
    Installing the 
    Sun Solaris 
    Patches
    2
    Overview2The Sun Solaris patches are delivered with the CMS software.
    Platform 
    Considerations
    2
    lAll platforms.
    Prerequisites2lThe Solaris 7 operating system must be installed.
    lAll Solaris packages must be installed (HSI/S, HSI/P, SAI/P, X.25) as 
    required by your particular system configuration.
    lThe Solstice DiskSuite software must be installed.
    lVerify that you are logged in as root at the console.
    lObtain the “CentreVu Call Management System” CD 
    Procedure21. Load the “CentreVu Call Management System” CD into the 
    CD-ROM drive.
    2. After about 15 seconds, enter mount to verify the name of the 
    CD-ROM. The program responds with a list of devices and file 
    systems currently mounted. The last line should display the installed 
    CD as shown below:
    3. Begin the installation by entering the following:
    /usr/sbin/pkgadd -d /cdrom/cdrom0 spatches
    The program responds:
    /cdrom/cms on /vol/dev/dsk/c0t2d0/cms read only on
    (
    current date and time)
    This package contains scripts which will be executed with 
    super-user permission during the process of installing 
    this package.
    Do you want to continue with the installation of 
     [y,n,?] 
    						
    							  Installing Software and Setting Up CMS CentreVu®  CMS R3V8 Software Installation and Setup
    Installing DiskSuite2-87
    4. Enter y to continue. The program responds:
    5. To continue installing the patches, enter:
    /tmp/patches/install_patches | tee -a /var/sadm/spatch.log
    The program responds:
    The program generates various lists of files to be patched. This can 
    take from 30 minutes to several hours to process, depending on the 
    number of patches and the CMS computer. When it finishes, the 
    program displays the system prompt.
    6. Reboot the system by entering:
    /usr/sbin/shutdown -y -i6 -g0
    7. Log in as 
    root. The Sun Solaris patches are installed and the system 
    kernel has been rebuilt. 
    Do 
    not remove the “CentreVu Call Management System” CD from 
    the CD-ROM drive.
    Changing 
    Directory 
    Permissions
    B
    1. To change directory permissions for the etc directory, enter:
    installf SUNWcsr /etc d 0755 root sys
    Installing CMS Supplied Solaris Patches as 
    . . . 
    Installation of  was successful.
    Generating list of files to be patched...
    Verifying sufficient filesystem capacity (exhaustive method)
    Installing patch packages...
    Patch number 103461-18 has been successfully installed.
    See /var/sadm/patch/103461-18/log for details
    Patch packages installed:
      SUNWmfrun 
    						
    							  Installing Software and Setting Up CMS CentreVu®  CMS R3V8 Software Installation and Setup
    Installing DiskSuite2-88
    Setting Up 
    Solstice 
    DiskSuite
    2
    Overview2This procedures configure Solstice DiskSuite for the system.
    Separate procedures are provided for unmirrored and mirrored 
    systems. For more information about disk-mirrored CMS systems, see 
    CentreVu® CMS Disk-Mirrored Systems (585-210-940).
     Platform 
    Considerations
    2
    lAll platforms 
    Prerequisites2lThe Solaris 7 operating system must be installed
    lThe Solstice DiskSuite software must be installed
    lThe Solaris patches must be installed
    lVerify that you are logged in as root at the console
    lThe “CentreVu Call Management System” CD should be loaded in 
    the CD-ROM drive
    Configuring 
    DiskSuite on an 
    unmirrored 
    system
    2
    This procedure configures DiskSuite on an unmirrored system. 
    1. Enter:
    stty erase
    
    (where  means “press/hold Control as 
    you press H”)
    The stty command sets up your backspace key as an actual 
    backspace. If you do not enter this command, you will have to use 
    the Delete key as a backspace.
    NOTE: 
    						
    							  Installing Software and Setting Up CMS CentreVu®  CMS R3V8 Software Installation and Setup
    Installing DiskSuite2-89
    2. Enter the following commands:
    3. Create system files for the 
    Solstice DiskSuite software by entering 
    these commands:
    PATH=$PATH:/usr/opt/SUNWmd/sbin
    export PATH
    /olds/olds -check_disks
    The system responds:
    If this command fails, see “Troubleshooting a Solstice DiskSuite 
    Software Installation” in Chapter 5, “Solving Installation-Related 
    Problems”.
    mkdir /olds 
    cp /cdrom/cdrom0/cms/reloc/rdonly/olds_install/* /olds
    cd /olds
    chmod +x /olds/olds
    scsi=c1
    number of external scsi controllers with disks  is = 1
    number of disks is = 2
    checking device: c0t0d0
    Warning: Current Disk has mounted partitions.
    checking device: c0t2d0
    device: c0t2d0 will not be used
    checking device: c1t0d0
    checking device: c[0-3]t1[0-9]d0
    device: c[0-3]t1[0-9]d0 will not be used
    valid disks are c0t0d0 c1t0d0
    Warning: Current Disk has mounted partitions.
    disk:c0t0d0 is partitioned ok
    disk:c1t0d0 is partitioned ok
    Success, checking disks.
    NOTE: 
    						
    							  Installing Software and Setting Up CMS CentreVu®  CMS R3V8 Software Installation and Setup
    Installing DiskSuite2-90
    4. Enter the following:
    /olds/olds -mk_files
    The system responds:
    5. When the system prompt reappears, verify that all the disk drives on 
    your system have been recognized. To do that, enter:
    cat /olds/md.tab.new
    Find the #/cms section; it should reflect the precise number of disk 
    drives on your system. The example shown below shows two disk 
    drives on the system:
    6. If everything appears to be correct, continue with Step 7.
    If there is a discrepancy in the number of disks, check for disk 
    recognition errors using the procedure, “Checking for Disk 
    Recognition Errors” on Page 2-95.
    7. Save the original vfstab and md.tab files with the following 
    commands:
    cp /etc/vfstab /etc/vfstab.orig
    cp /etc/opt/SUNWmd/md.tab /etc/opt/SUNWmd/md.tab.orig
    scsi=c1
    number of external scsi controllers with disks  is = 1
    number of disks is = 2
    Success, creating md.tab.new and/or vfstab.new. 
    #state database replicas
    mddb00 c0t0d0s1
    mddb01 c1t0d0s0
    #/cms
    d19 2 1 /dev/rdsk/c0t0d0s3 1 /dev/rdsk/c1t0d0s1
    d21 -m d19 
    						
    							  Installing Software and Setting Up CMS CentreVu®  CMS R3V8 Software Installation and Setup
    Installing DiskSuite2-91
    8. Enter:
    /olds/olds -metadbs
    The program responds:
    9. Enter:
    /olds/olds -setup
    The olds -setup command may take some time. It should take 
    about 1 minute of run time for each gigabyte of hard disk space on 
    your system.
    scsi=c1
    number of external scsi controllers with disks  is = 1
    number of disks is = 2
    checking device: c0t0d0
    Warning: Current Disk has mounted partitions.
    checking device: c0t2d0
    device: c0t2d0 will not be used
    checking device: c1t0d0
    checking device: c[0-3]t1[0-9]d0
    device: c[0-3]t1[0-9]d0 will not be used
    valid disks are c0t0d0 c1t0d0
    Warning: Current Disk has mounted partitions.
    disk:c0t0d0 is partitioned ok
    disk:c1t0d0 is partitioned ok
    Success, setting up metadb replicas. 
    						
    							  Installing Software and Setting Up CMS CentreVu®  CMS R3V8 Software Installation and Setup
    Installing DiskSuite2-92
    If all of the commands succeed, the system responds with a series 
    of lines reflecting the structure of your disk system. Those lines will 
    look something like the following (the specific disk names will vary 
    from system to system):
    The program begins to construct the new file system. When the 
    “Success...” message displays and the system prompt reappears, 
    the file system is complete and you are ready to continue with the 
    installation. The program responds:
    If these commands fail, make a note of the error message and see 
    the “Solving Installation-Related Problems” on page 5-1
    ”.
    scsi=c1
    number of external scsi controllers with disks  is = 1
    number of disks is = 2
    checking device: c0t0d0
    Warning: Current Disk has mounted partitions.
    checking device: c0t2d0
    device: c0t2d0 will not be used
    checking device: c1t0d0
    checking device: c[0-3]t1[0-9]d0
    device: c[0-3]t1[0-9]d0 will not be used
    valid disks are c0t0d0 c1t0d0
    Warning: Current Disk has mounted partitions.
    disk:c0t0d0 is partitioned ok
    disk:c1t0d0 is partitioned ok
    d19: Concat/Stripe is setup
    .
    .
    /dev/md/rdsk/d19:14422590 sectors in 15262 cylinders of 15 tracks, 63 
    sectors
    7042.3MB in 954 cyl groups (16 c/g, 7.38MB/g, 3584 i/g)
    super-block backups (for fsck -F ufs -o b=#) at:
     32, 15216, 30400, 45584, 60768, 75952, 91136, 106320, 121504, 136688,
     167056, 182240, 197424, 212608, 227792, 241952, 257136, 272320, 287504,
    .
    .
    .
    14198416, 14213600, 14228784, 14243968, 14259152, 14273312, 14288496,
     14303680, 14318864, 14334048, 14349232, 14364416, 14379600, 14394784,
     14409968,
    ufs fsck: sanity check: /dev/md/rdsk/d19 okay
    Success, system set up successfully 
    						
    All Lucent Technologies manuals Comments (0)