SW 5210TL-130500-1001 9. Dictation access circuits: No limit. No software limit exists for the number of dictation access circuits in the system. However, each assigned dictation access card reduces the number of available lines by eight or the number of available trunks by four. 10. Display telephone sets (calling/called number): The limit of sets is the total number of stations in the switch. Stations equipped with a calling number display cannot have the message-waiting feature. 11. The Analog Featurephone and Digital Featurephone maximums cannot occur simultaneously. The system supports a maximum of 128 for a mixture of both types of phone.8187S-l 73
TL-130500-1001Table 10.10Universal PC6 Cards Maximum System Capacities (Voice) CARD TYPECIRCUITS PEROff-Premises Line Card Conference (8-Party) Attendant Interface Dictation/Paging/Code Calling PDTMF Receiver Two-Wire Trunk (Two-Way Loop) Two-Wire Trunk (Two-Way E&M) Two-Wire Trunk (One-Way Incoming Loop) Four-Wire Trunk (Two-Way E&M) FB-51267-A 4 9 Tl Access/Spam Interface FB-17277-A or1FB-15277-l A Tl Frame DetectorFB-15278-A1 Tl Line Compensator FB-15280-A1 Tl Buffer FB-171921 Tl Supervisory Circuit FB-20718-l A1PCM Release Link Trunk FB-17251 -A4 4 Sl Dual Modem and Loop Interface ’ FB-17209-A28Control Interface ProcessorFB-17225-A 8 16Voice Control Interface Processor FB-17235-A 8 16Data Voice Control Interface FB-17236-A4 Voice/4 Data16Processor VPLC2FB-17246-A8 8 OMNI Automatic Identification of FB-17276-A41Outward Dialing S-l 74 8187SVR 5210
-.:.:.TL-130500-1001 Table 10.11Voice - Data Circuit Ratios (Without a Tl Span) 8-CircuitTrunkVoice Packet Line CardsVoice Lines Trunk Cards CircuitsLine Card 2Data Ports (VPLC2) 0000 15120 2161414112 6481413104 221764 16648 23184416540 22176520432 26208 520324 27216624216 SVR 5210&I37s-175
TL-130500-1001Table 10.12Voice - Data Circuit Ratios (With a Tl Span) 8 Circuit Line CardsVoice CircuitsI 2I16 72 12I 16I128I 18I144 Trunk CardsTrunkVPLC2 CircuitsCardsData Ports I88I I72I I 64 I561 3 I16II16I S-1768187SVR5210
TL-130500-1001ORDERING THE11.0 The hardware editing sheets (FM-41460-A) used VOICE SYSTEMfor this release must be completed to order SVR 5210. Ordering Guide (FM-41 640) provides instructions for completing the editing sheets. The system can be ordered as either a standard or custom hardware configuration. Standard Hardware11.1 The standard configuration is available in two sizes. Configurationl 48 lines/4 trunks l 96 lines/4 trunks Normally a standard system is shipped within three weeks from receipt of the order. Any additional equipment needed must be ordered piecemeal. Custom Hardware11.2 When ordering a custom system, order all peripheral cards Configurationand software required. A custom configuration is shipped within eight weeks from receipt of the order. In addition to starndard or custom hardware, software is also ordered as either standard or custom configuration. Whenever possible, order a customized data base. When ordering a custom system, fill out the frame layout worksheet that is included in the Ordering Guide. Submit the frame layout worksheet along with the completed editing sheets when ordering the system. Use the following steps and flowchart (Figure 11 .l) when completing the frame layout worksheet: 1. Determine quantity of each type of universal card required. 2. Determine quantity of universal card slots needed. 3. Fill in the frame layout sheet with the following: a. If used, place Tl span cards. b. Place trunk cards using preferred location first. c. Fill remainder of double width card slots. d. Place single height cards evenly among equipped time groups. e. Place line cards. f. Place CIP cards next to line card. g. Add any remaining single height cards. NOTE: Use pencil when filling in this form. SVR 5210 8187s-1 77
TL-130500-1001START vPerform Traffic Study for Each of the 6 Time Slot Groups A NO TDetermine if the Traffic is Balanced 4 Figure 11.1Flowchart for Balancing System Traffic S-l 78 8’87SW 5210
TL-130500-1001PCMUS GROUP CIFILE As >I 5 -21- ; - IUP & Y14 - I EXP~~E”‘ON (W, +-GROUP 6 jPCMUS GROUP D FILE B II-COMMON CONTROL-If- PCM~$oGU~O~P A Figure 11.2Frame Layout Worksheet Addressing SVR5210 8187s-179
TL-130500-1001 NOTES: The following infirmation should be considered when configuring a system. l Refer to the card description section of this document, section 3.0, for information on cards required to support features to be implemented.o Figure 11.2 provides information for determining card slots required. l Provide a minimum of 20% growth for the system. l If group D is required, then an extra PCMFS and PCMI must be ordered. Put a PCMFS (FB-17189) card in slot 06 and a PCMI (FB-17187) card in slot 08 of the Expansion File. l Tl span cards go into the Tl span card slots in between Cl-C6, located to the right of the PCMUS. l Preferred locations for double width cards are: - 11 span location when the Tl-span option is not used. - Al 1, which provides an overhang for a double width card as it is a heat vent - Bll and Dll, which provide overhang into the cabinet l Use single width location for double width cards only after using all double width locations. l The ATT12 has no overhanging parts, but due to its heat output requires an empty slot next to it for ventilation. e When possible the PLCC and CIP cards required to support the Analog Featurephone should be put into card slots next to one another. Circuits for a given IFP should also match on both cards. Assign circuit in the following order: 4, 0, 5, 1, 6, 2, 7, 3. Circuits 0, 2, 4, and 6 of the DVCIP card are used for voice, while circuits 1, 3, 5, and 7 are used for data. l Traffic study must be done for each time slot group. Tables 11.2 and 11.3 are provided to help in determining traffic l If the traffic study indicates that blockage will occur, the card must be relocated. l If the traffic study indicates a large imbalance in CCS per group, it is recommended o reposition cards. In some cases, one group may have been deliberately configured with a lowamount of CCS traffic, which is acceptable. l It may be necessary to try several locations for the various cards before a proper balance is achieved. S-l 80 8187SVR 5210
TL-130500-1001 Table 11.1Card Parameters MNEMONICWIDTHGUARCKTs ON Ws)CARD PART NO. FB-17201 -AFB-17202-A FB-17203-A FB-17208-A FB-17209-A FB-1721 O-AFB-17225-A FB-17226-A FB-17426-A FB-17227-A FB-17228-A FB-17229-A FB-17230-A FB-17231 -AFB-17235-A FB-17250-A FB-17251 -AFB-17254-A FB-51267-A FB-51279-A FB-51280-APEMT IDoubleIPCOT PDTMFDouble Single ATT12IDoubleI SIDMLIDoubleI PADICDoubleI0 CIPISingleI VPLC (VPLO) VPLC (VPLl)Single Single 08 0 2 VPLC2 (VPLO) VPLC2 (VPLl)Single Single 08 02 PBEfl-ISingleI PRADMP-ASingle Single01 01ADMP-B ISingleI0I1 UCB/DCP 1SingleI1 VCIPISingleIPOPS IDoubleIIIIRLT H44 PLCC1SingleIPFWTA IDoubleI0”i-~4PCONF ISingleI IDouble INOTE: Guaranteed TS(s) (Time Slot(s)) required on this card when: *CKT(s) control RA(s) “CKT(s) used with ACDICAS Agent Instrument. + CKT assigned for M-O-H or attendant line circuit + + If all 24 Tl trunks are enabled the Tl span uses all 24 TSs.If not, some TSs can be used for other equipment. SVR 5210 8187S-l 81
TL-130500-1001 S-l 828i87Table 11.2 Available CCSs AVAILABLE CCS I II 23500540I 22472510 21443480I I1 19138814221 1 18 1 360 1 393 1 Table 11.3 Group Traffic GROUP TRAFFIC AT P = 0.01 Required Forms11.3 When the frame layout worksheet from the Hardware Ordering Guide (FM-41480) has been completed, the hardware editing sheets are to be filled out. The editing sheets contain a listing of all software and hardware components of the system. When completed, a copy of the editing sheets and a copy of the frame layout workskeets are to be submitted. NOTE: Use the frame layout worksheet, found in the SlHardware Ordering Guide FM-41450, when ordering a system. SVR 5210