    							SW 5210TL-130500-1001
    9. Dictation access circuits: No limit. No software limit exists
    for the number of dictation access circuits in the system.
    However, each assigned dictation access card reduces the
    number of available lines by eight or the number of available
    trunks by four.
    10. Display telephone sets (calling/called number): The limit of
    sets is the total number of stations in the switch. Stations
    equipped with a calling number display cannot have the
    message-waiting feature.
    11. The Analog Featurephone and Digital Featurephone
    maximums cannot occur simultaneously. The system
    supports a maximum of 128 for a mixture of both types of
    phone.8187S-l 73 
    						
    							TL-130500-1001Table 10.10Universal PC6 Cards Maximum System Capacities (Voice)
    CARD TYPECIRCUITS PEROff-Premises Line Card
    Conference (8-Party)
    Attendant Interface
    Dictation/Paging/Code Calling
    PDTMF Receiver
    Two-Wire Trunk (Two-Way Loop)
    Two-Wire Trunk (Two-Way E&M)
    Two-Wire Trunk
    (One-Way Incoming Loop)
    Four-Wire Trunk (Two-Way E&M)
    FB-51267-A
    4
    9
    Tl Access/Spam Interface
    FB-17277-A or1FB-15277-l A
    Tl Frame DetectorFB-15278-A1
    Tl Line Compensator
    FB-15280-A1
    Tl Buffer
    FB-171921
    Tl Supervisory Circuit
    FB-20718-l A1PCM Release Link Trunk
    FB-17251 -A4
    4
    Sl Dual Modem and Loop Interface ’ FB-17209-A28Control Interface ProcessorFB-17225-A
    8
    16Voice Control Interface Processor
    FB-17235-A
    8
    16Data Voice Control Interface
    FB-17236-A4 
    Voice/4 Data16Processor
    VPLC2FB-17246-A8
    8
    OMNI Automatic Identification of
    FB-17276-A41Outward Dialing
    S-l 74
    8187SVR 5210 
    						
    							-.:.:.TL-130500-1001
    Table 10.11Voice - Data Circuit Ratios (Without a Tl Span)
    8-CircuitTrunkVoice Packet
    Line CardsVoice Lines Trunk Cards
    CircuitsLine Card 2Data Ports
    (VPLC2)
    0000
    15120
    2161414112
    6481413104
    221764
    16648
    23184416540
    22176520432
    26208
    520324
    27216624216
    SVR 5210&I37s-175 
    						
    							TL-130500-1001Table 10.12Voice - Data Circuit Ratios (With a Tl Span)
    8 Circuit Line
    CardsVoice CircuitsI
    2I16
    72
    12I
    16I128I
    18I144
    Trunk CardsTrunkVPLC2
    CircuitsCardsData Ports
    I88I
    I72I
    I
    64
    I561
    3
    I16II16I
    S-1768187SVR5210 
    						
    							TL-130500-1001ORDERING THE11.0 The hardware editing sheets (FM-41460-A) used
    VOICE SYSTEMfor this release must be completed to order SVR 5210. Ordering
    Guide (FM-41 640) provides instructions for completing the
    editing sheets. The system can be ordered as either a standard
    or custom hardware configuration.
    Standard Hardware11.1 The standard configuration is available in two sizes.
    Configurationl 48 lines/4 trunks
    l 96 lines/4 trunks
    Normally a standard system is shipped within three weeks from
    receipt of the order. Any additional equipment needed must be
    ordered piecemeal.
    Custom Hardware11.2 When ordering a custom system, order all peripheral cards
    Configurationand software required. A custom configuration is shipped within
    eight weeks from receipt of the order.
    In addition to starndard or custom hardware, software is also
    ordered as either standard or custom configuration. Whenever
    possible, order a customized data base.
    When ordering a custom system, fill out the frame layout
    worksheet that is included in the Ordering Guide.
    Submit the frame layout worksheet along with the completed
    editing sheets when ordering the system.
    Use the following steps and flowchart (Figure 11 
    .l) when
    completing the frame layout worksheet:
    1. Determine quantity of each type of universal card required.
    2. Determine quantity of universal card slots needed.
    3. Fill in the frame layout sheet with the following:
    a. If used, place 
    Tl span cards.
    b. Place trunk cards using preferred location first.
    c. Fill remainder of double width card slots.
    d. Place single height cards evenly among equipped time
    groups.
    e. Place line cards.
    f. Place CIP cards next to line card.
    g. Add any remaining single height cards.
    NOTE: Use pencil when filling in this form.
    SVR 5210
    8187s-1 77 
    						
    							TL-130500-1001START
    vPerform Traffic Study for
    Each of the 6 Time Slot
    Groups
    A
    NO
    TDetermine if the Traffic
    is Balanced
    4
    Figure 11.1Flowchart for Balancing System Traffic
    S-l 78
    8’87SW 5210 
    						
    							TL-130500-1001PCMUS GROUP CIFILE As
    >I
    5
    -21-
    ;
    -
    IUP
    &
    Y14
    -
    I
    EXP~~E”‘ON
    (W,
    +-GROUP 6 jPCMUS GROUP 
    D
    FILE B
    II-COMMON CONTROL-If- PCM~$oGU~O~P A
    Figure 11.2Frame Layout Worksheet Addressing
    SVR5210
    8187s-179 
    						
    							TL-130500-1001
    NOTES: The following infirmation should be considered when
    configuring a system.
    l Refer to the card description section of this document, section
    3.0, for information on cards required to support features to be
    implemented.o Figure 11.2 provides information for determining card slots
    required.
    l Provide a minimum of 20% growth for the system.
    l If group D is required, then an extra PCMFS and 
    PCMI must
    be ordered. Put a PCMFS (FB-17189) card in slot 06 and a
    PCMI (FB-17187) card in slot 08 of the Expansion File.
    l 
    Tl span cards go into the Tl span card slots in between Cl-C6, located to the right of the PCMUS.
    l Preferred locations for double width cards are:
    - 11 span location when the Tl-span option is not used.
    - Al 1, which provides an overhang for a double width card as
    it is a heat vent
    - Bll and Dll, which provide overhang into the cabinet
    l Use single width location for double width cards only after
    using all double width locations.
    l The 
    ATT12 has no overhanging parts, but due to its heat output
    requires an empty slot next to it for ventilation.
    e When possible the PLCC and CIP cards required to support
    the Analog Featurephone should be put into card slots next to
    one another. Circuits for a given IFP should also match on
    both cards. Assign circuit in the following order: 4, 0, 5, 1, 6, 2,
    7, 3. Circuits 0, 2, 4, and 6 of the 
    DVCIP card are used for
    voice, while circuits 1, 3, 5, and 7 are used for data.
    l Traffic study must be done for each time slot group. Tables
    11.2 and 11.3 are provided to help in determining traffic
    l If the traffic study indicates that blockage will occur, the card
    must be relocated.
    l If the traffic study indicates a large imbalance in CCS per
    group, it is recommended 
    o reposition cards. In some cases,
    one group may have been deliberately configured with a 
    lowamount of CCS traffic, which is acceptable.
    l It may be necessary to try several locations for the various
    cards before a proper balance is achieved.
    S-l 80
    8187SVR 5210 
    						
    							TL-130500-1001
    Table 11.1Card Parameters
    MNEMONICWIDTHGUARCKTs ON
    Ws)CARD PART NO.
    FB-17201 -AFB-17202-A
    FB-17203-A
    FB-17208-A
    FB-17209-A
    FB-1721 O-AFB-17225-A
    FB-17226-A
    FB-17426-A
    FB-17227-A
    FB-17228-A
    FB-17229-A
    FB-17230-A
    FB-17231 -AFB-17235-A
    FB-17250-A
    FB-17251 -AFB-17254-A
    FB-51267-A
    FB-51279-A
    FB-51280-APEMT
    IDoubleIPCOT
    PDTMFDouble
    Single
    ATT12IDoubleI
    SIDMLIDoubleI
    PADICDoubleI0
    CIPISingleI
    VPLC (VPLO)
    VPLC (VPLl)Single
    Single
    08
    0
    2
    VPLC2 (VPLO)
    VPLC2 (VPLl)Single
    Single
    08
    02
    PBEfl-ISingleI
    PRADMP-ASingle
    Single01
    01ADMP-B
    ISingleI0I1
    UCB/DCP 1SingleI1
    VCIPISingleIPOPS
    IDoubleIIIIRLT
    H44
    PLCC1SingleIPFWTA
    IDoubleI0”i-~4PCONF
    ISingleI
    IDouble
    INOTE: Guaranteed 
    TS(s) (Time Slot(s)) required on this card
    when:
    *CKT(s) control RA(s)
    “CKT(s) used with ACDICAS Agent Instrument.
    + CKT assigned for M-O-H or attendant line circuit
    + + If all 24 
    Tl trunks are enabled the Tl span uses all 24 TSs.If not, some 
    TSs can be used for other equipment.
    SVR 5210
    8187S-l 81 
    						
    							TL-130500-1001
    S-l 828i87Table 11.2 Available 
    CCSs
    AVAILABLE CCS
    I
    II
    23500540I
    22472510
    21443480I
    I1
    19138814221
    1  18 1  360 1  
    393 1
    Table 11.3 Group Traffic
    GROUP TRAFFIC AT P = 0.01
    Required Forms11.3 When the frame layout worksheet from the Hardware
    Ordering Guide (FM-41480) has been completed, the hardware
    editing sheets are to be filled out. The editing sheets contain a
    listing of all software and hardware components of the system.
    When completed, a copy of the editing sheets and a copy of the
    frame layout workskeets are to be submitted.
    NOTE: Use the frame layout worksheet, found in the 
    SlHardware Ordering Guide FM-41450, when ordering a system.
    SVR 5210 
    						