Home > GTE > Communications System > GTE Omni Si Database Technical Practices Issue 1 Manual

GTE Omni Si Database Technical Practices Issue 1 Manual

    Download as PDF Print this page Share this page

    Have a look at the manual GTE Omni Si Database Technical Practices Issue 1 Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 3 GTE manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 762
    							TL-130500-1001TABLE OF CONTENTSPAGE
    s-354
    36.4S-358
    36.5S-360
    36.6S-360
    36.6.1S-360
    36.6.2S-360
    36.6.3S-360
    36.6.4S-360
    36.6.5
    S-36136.6.6
    S-36136.6.7
    S-36136.6.8S-362
    36.6.9S-362
    36.6.10S-362
    36.6.11S-362
    36.6.12S-362
    36.6.13S-36236.6.14
    S-363
    36.6.15S-363
    36.6.16S-363
    36.6.17S-363
    36.7S-364
    36.8S-364
    36.8.1S-364
    36.8.2S-366
    36.8.3S-367
    36.8.4S-368
    36.8.5S-368
    36.8.6
    s-371
    36.8.7
    s-371
    36.8.8PARA-
    GRAPH
    SW 5210TOPIC
    Transmission 
    P,erformance and Testing Procedures
    Test Equipment
    Transmission Performance Specifications
    lmpendance and Resistance
    Insertion Loss
    Frequency Response
    Level Tracking Error
    Signal to Distortion (C-Notch)
    Intermodulation Distortion (Four-Tone Method)
    Single Frequency Distortion
    Envelope Delay Distortion
    Path Message Noise
    Path Impulse Noise
    Crosstalk Attenuation
    Longitudinal Balance
    Return Loss
    Longitudinal Susceptability
    Tones
    Leakage Tolerance
    High Frequency Cabling Limitations
    Alignment
    Transmission Test Procedures
    Battery Feed and Hold Cold Arrangements
    Insertion Loss and Frequency Response
    Level Tracking Error and C-Notch Distortion
    Intermodulation Distortion, Envelope Delay Distortion, and Noise
    Crosstalk Attenuation
    Longitudinal Balance Attenuation
    Longitudinal Susceptability
    Echo and Singing Return Loss
    8187s-13 
    						
    							TL-130500-1001
    THIS PAGE IS INTENTIONALLY LEFT BLANK
    s-148187SVR 5210 
    						
    							TL-130400-1001LIST OF FIGURESPAGEFIGURE
    NUMBERTOPIC
    S-272.1s-29
    2.2
    s-31
    2.3
    S-36
    3.1
    S-383.2s-39
    3.3s-40
    3.4s-45
    3.5
    S-483.6s-50
    3.7S-52
    3.8s-54
    3.9
    S-653.10
    S-674.1
    S-694.2
    S-69
    4.3s-70
    4.4
    s-71
    4.5
    S-784.6s-79
    4.7
    S-804.8
    S-80
    4.9
    S-81
    4.10
    S-834.11
    S-874.12
    S-894.13s-90
    4.14SVR 5210System Cabinet
    Equipment Cabinet
    OMNI SICard Slot Locations
    Frame Image Card Locations for a Fully Configured System
    Pulse Code Modulation Group Division
    Common Control Card Slots
    INCKS Card Handle View
    Universal Printed Wiring Card Slots
    SIL Card Handle View
    TlS Card Handle View
    Universal Printed Wiring Card Slots
    PSUPY Card
    CPU Connections
    Control and Sensing Connections of PCM Universal Slot (PCMUS)
    Common Control Related Circuits
    Time-Switch Network
    Time-Switch Memory Setup
    Time Slot Group Division
    Sampling an Analog Signal
    Sampling an Analog Signal
    File Bus with Samples Present
    Time-Switch Network Sequence and Interleaving Comparison
    Card Handle Views
    Memory Page Card
    Simplified Disk System Interface
    FMSD and Hard Disk Assembly Interface
    8187s-1 5 
    						
    							TL-130400-1001
    FIGURE
    PAGENUMBER TOPIC
    s-934.15s-93
    4.16s-94
    4.17s-95
    4.18s-97
    5.1
    S-985.2
    s99-5.3s-99
    5.4s-100
    5.5
    S-1015.6s-102
    5.7
    s-1 035.8s-103
    5.9S-l 05
    6.1S-l 06
    6.2S-l 08
    6.3S-l 09
    6.4
    s-1 126.5s-113
    6.6s-115
    7.1S-l 24
    8.1
    S-1 258.2S-l 26
    8.3S-l 28
    8.4
    s-1 308.5S-l 38
    9.1S-l 38
    9.2
    s-1 6DBA Calculation
    Disk File Breakdown
    FMSD Disk File Layout
    Disk File Directory Record Format
    Circuit Switched Data
    PCM (Pulse Code Modulation) Bus
    Data Call
    Data Call Processing
    End User Data Terminal and Host Computer Data Call
    Incoming Modem Call
    Outgoing Modem Call
    Digital Telephone Data Packet Flow
    Mini Packet
    OMNI PD-200
    Data System Access to Mass Storage
    ADMP Terminal
    Possible Local Packet Bus Configuration
    Remote 
    Processor/VPLC (Voice Packet Line Card Connection).
    X.29 Protocol
    Universal Printed Wiring Card Slots Used By PD-200 Cards
    FMSD Interface
    Simplified Disk System Interface
    FMSD and Hard Disk Assembly Interface
    Disk System Cabling
    Transportation of Mini-packets over LPB
    International Numbering Plan for Public Data Network Addressing
    DNIC for Telenet
    8187SVR 5210 
    						
    							TL-130400-1001LIST OF FIGURESFIGURE
    PAGENUMBER TOPIC
    s-139 9.3
    s-1 39
    9.4s-141 9.5
    S-l 41
    9.6s-141 9.7
    S-142 9.8
    S-148
    9.9S-l 49
    10.1S-l 50
    10.2S-l 
    5110.3S-l 56
    10.4S-l 64
    10.5S-l 78
    11.1S-l 79
    11.2S-l 86
    12.1S-l 86
    12.2S-l 86
    12.3S-l 87
    12.4S-l 87
    12.5S-l 87
    12.6S-l 89
    12.7S-204
    12.8S-206
    13.1s-209
    15.1
    s-21 3
    15.2SVR 5210Example of 
    DNIC Server Number
    Example of 
    DNIC Server Number and Sub-Port
    Rotary Hunt Group Example
    Example of Rotary Hunt Group Numbering Plan
    Example of Load Sharing Numbering Plan
    Load Sharing Example
    Data Connections
    Analog and Digital Signals
    PCM (Pulse Code Modulation) Low Level Bus
    Time Switching Groups
    Traffic Study 1
    Traffic Studdy 2
    Balancing System Traffic
    Frame Layout Work Sheet Addressing
    Example of Single Local Packet Buses In Group A 
    & B
    Example of Two Local Packet Buses (LPB 0, LPB 1) In Groups A 
    & B, C & DExample of Single Local Packet Buses In Group B
    Example of Two Local Packet Buses In Groups B 
    & D
    Example of Two Local Packet Buses (LPB 0, LPB 1) In Groups A& B and D
    Example of Two Local Packet Buses (LPB 0, LPB 1) In Groups B and C 
    & D
    Card Placement
    Number of Ports per Local Packet Bus Versus Bandwidth Utilization
    Configuring The System
    Attendant Console
    Attendant Console Controls and Indicators
    8187s-17 
    						
    							TL-130400-1001
    FIGURE
    PAGENUMBER TOPICS-21 816.1S-224
    16.2S-226
    17.1S-227
    17.2S-228
    17.3S-238
    17.4S-242
    17.5S-243
    17.6S-248
    18.1s-249
    18.2S-254
    19.1s-259
    21 .lS-263
    22.1S-276
    28.1
    S-28129.1S-284
    29.2S-287
    29.3S-28929.4
    s-293
    30.1s-295
    31.1
    S-29631.2S-298
    31.3s-29931.4
    S-l 8BLDU (Stand-Alone and Mounted)
    BLDU Display Fields
    Display Telephone
    Standalone Featurephone
    Integrated Featurephone with DSS
    Block Diagram of Digital Featurephone With VCIP or 
    DVCIP Card
    Agent Instrument
    Agent Instrument Controls and Indicators
    KEDU (Key Entry Display Unit)
    KEDU (Key Entry Display Unit) Button Function
    *Axiom Printer Used With (or Without) KEDU in Hotel/Health Care Applications
    MDR Typical Configuration
    Type 200 Test Set
    Release Link Trunks
    Tl-Type Digital Trunk Link
    Tl Digital Trunk Interface in the System
    FB-15277-1A Span Interface Card Handle
    FB-20718-1A Tl Type (Tl S) Supervisory Card Handle
    Connections of Data Devices
    Asynchronous Packet Manager
    APM (Asynchronous Packet Manager) Connection
    The Transport of Minipackets
    Mini Packet Protocol
    8187SVR 5210 
    						
    							TL-130400-1001LIST OF FIGURESPAGE
    s-301s-303
    S-306
    s-307
    S-308
    s-31 2S-320
    S-325
    s-331S-332
    s-335
    S-336
    s-337
    s-337
    s-339
    s-339
    s-349
    s-349
    s-350
    s-350
    s-355
    S-356s-357
    s-357
    S-358s-359
    s-359
    S-365FIGURE
    NUMBER TOPIC
    32.1Synchronous Packet Manager
    32.2Synchronous Packet Manager Interface
    33.1DFP/APM Voice and Data Bus Connection
    33.2Transmission from the Digital Featurephone to the System
    33.3Simultaneous Voice and Data Packet Structure
    33.4NIC Card within the OMNI System’s Architecture
    34.1Line Data Record Code Assignment Sheet
    34.2Time-Switch Memories During Idle
    34.3Off-Hook Time Slot Assignment
    34.4DTMF Receiver Assignment and Dial Tone
    34.5Interdigit and DTMF Tones
    34.6Last Digit Dialed, DTMF Receiver Released
    34.7Called Telephone Assigned Time Slot
    34.8Ringback Sent to Originating Caller
    34.9Conversation
    34.10Call Terminated
    36.1Line-to-Line Call (VNLP or FLP)
    36.2Line-to-CO Trunk Call (VNLP)
    36.3Line-to-Inter-tandem-Tie Trunk Call (VNLP)
    36.4Line-to-Nontandem-Tie Trunk Call (VNLP)
    36.5Line-to-CO Trunk Call (FLP)
    36.6Line-to-CO Trunk Call (FLP) with Voice Frequency Repeater
    36.7Line-to-Nontandem Tie Trunk Call (FLP)
    36.8Line-to-CO Trunk Call (FLP) with Tl-Type Repeater Line
    36.9Line-to-Inter-tandem Tie Trunk Call (FLP)
    36.10Line-to-Intertandem Tie Trunk Call (FLP) with Tl-Type Repeater Line
    36.11Inter-tandem Tie Trunk-to-CO Trunk Call (FLP)
    36.12Hold Coil and Battery Feed Arrangements
    SVR 5210
    8t87s-19 
    						
    							TL-130400-1001
    FIGURE
    NUMBER TOPIC36.13Insertion Loss and Frequency Response Measurement
    36.14Level Tracking and C-Notch Distortion Measurement
    36.15Crosstalk Measurement
    36.16Longitudinal Attenuation Measurement
    36.17Longitudinal Susceptability Measurement
    36.18Intermodulation, Envelope Delay Distortion, Noise, and Return Loss Test
    Method PAGE
    S-367
    S-369
    s-370
    s-371
    S-372
    s-373
    s-20
    8187SVR 5210 
    						
    							\..TL-130400-1001
    LIST OF TABLESPAGETABLE
    NUMBER TOPIC
    S-251.1System Version Release
    S-322.1System Trade-Offs
    s-413.1s-49
    3.2s-55
    3.3s-55
    3.4
    S-653.5Common Control Cards
    Tl -Span Card
    Universal Printed Wiring Cards
    Universal Printed Wiring Card Physical Mounting Requirements
    Power Cards
    s-73
    4.1
    S-854.2Memory Cross-Reference Get Started FileChannel Memory to EPCMN
    Network Memory Cross-Reference
    System Tones and Tone Generation
    S-1167.1PD-200 Packet Data Cards
    S-l 22
    7.2PD-200 Data Card Functions
    s-133
    S-l 44
    S-l 46
    9.1
    9.2
    9.3Logical Links
    Alphabetical List of Printed Wiring Cards
    Numerical List of Printed Wiring Cards
    S-l 54
    10.1
    s-1 57
    10.2S-l 58
    10.3
    s-1 59
    10.4S-l 60
    10.5S-l 62
    10.6S-l 63
    10.7
    s-1 7010.8
    S-l 71
    10.9Estimated Traffic Equivalents
    Equipment Utilizing Dedicated Time Slots in a PCMUS Group
    Required PCM Progress Tone 
    Recognizer PCBAS
    Required PRLT Circuits
    Required PDTMF Receivers
    DTMF Receivers Required to Provide a P = 0.01 Grade-of-Service
    Traffic Capacity of a PCMUS Group Summary
    CAS Main/ACD Related System Capacities
    Line, Trunk, and Peripheral System 
    CapacitieSVR 5210
    8187s-21 
    						
    							-.
    TL--I 30400-l 001
    TABLE
    PAGE
    PARA--
    s-1 7410.10S-l 75
    10.11S-l 76
    10.12
    S-l 8111.1S-l 82
    11.2S-l 82
    11.3S-l 90
    12.1
    s-1 9212.2
    s-1 9312.3
    s-1 9412.4S-l 98
    12.5s-200
    12.6s-201
    12.7
    s-20 112.8S-223
    16.1S-232
    17.1S-237
    17.2S-256
    20.1S-260
    21 .lS-286
    29.1s-292
    29.2
    s-3&l33.1
    s-31 033.2
    s-22TOPIC
    Universal Printed Wiring Cards Maximum System Capacities (Voice)
    Voice 
    - Data Circuit Ratios (Without a Tl Span)
    Voice 
    - Data Circuit Ratios (With a Tl -Span)
    Card Parameters
    Available 
    CCSsGroup Traffic
    Worksheet for Data Option
    Voice Packet Line Card Type 0 and Type 1 Configuration Rules
    Printed Wiring Cards/Device Quantity per System
    Physical Location and Power Requirements of Cards
    Mini-Packet Equivalent for Each Throughput Specification
    Mini-Packets/Second for MPP Endpoints
    Mini-Packets/Second Capability of the 
    VPLCYPTSCall Setup and 
    Takedown Rates
    BLDU Display and Key Function
    Integrated Featurephone System Capacity Summary
    Types of Digital Featurephones
    Terminal Types
    Fujitsu GTE-Modified EBCDIC
    System 
    Tl Interface Cards
    Analog 
    Tl Nailed Connections Allowed
    Feature Comparison
    CCITT Recommendations
    8187SVR 5210 
    						
    All GTE manuals Comments (0)

    Related Manuals for GTE Omni Si Database Technical Practices Issue 1 Manual