    							TL-130100-1001STEPOPERATIONRESULT
    1
    2
    3
    4
    5
    6
    7
    8
    9
    NOTE:
    Initiate Do Not DisturbDepress 
    DON-T DIST button.
    Enter room number. (If room
    number is three digits, enter
    a # after the third digit.)
    If BBBB is displayed, depress
    ENTEFVXCUTE button.
    Depress 
    ENTERXCUTE button.
    Clear Do Not DisturbDepress DONT 
    DIST button.
    Enter room number. (If room
    number is three digits, enter
    a # after the third digit.)
    Depress CLEAR button.
    Depress ENTEFVXCUTE button.
    The next function performed clears
    the KEDU display.(a) DONT 
    DIST LED on.
    (b) KEDU display fields off.
    (c) ROOM NUMBER and DATA 
    LEDs on.
    (a) ROOM NUMBER field displays the room
    number.
    (b) DATA field displays 
    “AAAA” (activated)
    or “BBBB” (not activated).
    (c) Response code field displays “A”.
    DATA and response code display fields off.
    (a) DATA field displays 
    “AAAA” (do-not-
    disturb activated).
    (b) Response display field displays “A”.
    (a) DONT 
    DIST LED on.
    (b) KEDU display fields off.
    (c) ROOM NUMBER and DATA 
    LEDs on.
    (a) ROOM NUMBER field displays the room
    number.
    (b) DATA field displays “AAAA” (do-not-
    disturb activated).
    (c) Response code field displays “A”.
    DATA and response code display fields off.
    (a) DATA field displays “BBBB” (do-not-
    disturb deactivated).
    (b) Response code field displays “A”.
    Automatic wake-up calls are not blocked by the activation of this feature.
    Anaccess code also permits the attendant to reach the do-not-disturb party.
    52108187o-297 
    						
    							TL-130100-10011
    9.4.8Room Restriction, KEDU-ProvidedThe KEDU allows individual room station users (non-administrative phones)
    to be restricted from Direct Outside Dialing (DOD).
    NOTE:The Attendant Console and administrative telephone are also
    capable of providing the restriction feature. Procedures for these
    are covered in Sections: Room Restriction, Attendant 
    Console-Initiated and Room Restriction, Administrative 
    Telephone-Initiated.
    STEPOPERATION
    RESULT
    3
    4
    Initiating Room RestrictionDepress ROOM RSTR button.(a) ROOM RSTR LED on.
    (b) KEDU display fields off.
    (c) ROOM NUMBER LED on.
    (d) DATA LED on.
    Enter room number. (Must be 4 digits. (a) ROOM NUMBER field displays the room
    If 3 digits, key in 
    # after the third digit.)number.
    (b) DATA field displays “BBBB” (room
    restriction not activated).
    (c) Response code field displays “A”.
    Depress 
    ENTERIXCUTE button.Data and response display fields off.
    Depress 
    ENTERIXCUTE button.(a) Data field displays “AAAA” (room
    restriction activated).
    (b) Response code field displays “A”.
    (c) If printer is provided, see Table 9.2 for
    typical printer displays.
    The next function performed clears
    the KEDU.
    Cancellation of Room RestrictionDepress ROOM RSTR button.(a) ROOM RSTR button on.
    (b) KEDU display off.
    (c) ROOM NUMBER LED on.
    (d) DATA LED on.
    Enter room number.
    (a) ROOM NUMBER field displays the room
    number.
    (b) Data field displays “AAAA” (room
    restriction activated).
    (c) Response code field displays “A”.
    O-298
    81875210 
    						
    							TL-130100-1001
    OPERATIONRESULT8Depress CLEAR button.(a) Data and response code display fields
    (b) 
    $EAR LED on.
    9
    10Depress ENTEFVXCUTE button.
    The next function performed clears the
    KEDU display.(a) Data field displays “BBBB” (room
    restricted deactivated).
    (b) Response code field displays “A”.
    NOTE:
    Calls to the attendant, services, and administrative stations can still be made from
    the restricted station.
    5210
    8187o-299 
    						
    							TL-130100-1001
    THIS PAGE INTENTIONALLY LEFT BLANK.a/a75210 
    						
    							TL-130100-100110.0REFERENCES
    The following reference documents complement/supplement the information provided in this
    Practice: 
    -DOCUMENT
    FGBS Practices:NUMBER
    TL-130400-1001TL-130000-1001
    TL-130500-1001TL-130300-1001
    TL-130200-1001
    TL-100000-1001ISSUE
    1
    1
    1
    1
    1
    1DESCRIPTION
    Data Base
    Features
    System Configuration
    installation
    Maintenance
    ADMP User’s Guide
    Hardware
    Ordering
    Guide:
    Data Base
    Sheets:
    FM-41 4601Ordering Guide
    FM-41 460-A1Ordering Sheets
    FM-41 4613185Customer
    Instructions:Cl-278-248
    Cl-278-294
    Cl-278-401
    Cl-278-403
    Cl-278-409
    Cl-278-41 0
    Cl-278-41 1
    Cl-278-41 2Cl-473-335
    Cl-473-336
    Cl-473-365
    Cl-473-366
    Cl-473-397
    Cl-473-398
    Cl-47351 9
    1
    2
    1
    1
    1
    1
    1
    1
    1
    1
    1
    1
    1
    1
    1Software Programming Data Sheets
    (Instructions for completing the software
    programming data sheets are contained
    in Practice 278-921-030.)
    Executive Features Insert
    Busy Lamp Display Unit
    Attendant Manual 
    Hotel/Motel-Healthcare Features Insert
    Administrative Station 
    Hotel/Motel-Healthcare Features Insert
    OMNI Series Station User’s Guide
    OMNI Series Attendant Manual
    Maid Service Features Insert
    OMNI Series Generic Station User’s
    Guide (No Access Codes Included)
    Analog Featurephone User’s Guide
    (FeatureComm III and IV) (This
    document is obsolete.)
    Analog Featurephone Programming
    Manual (FeatureComm Ill and IV) (This
    document is obsolete.)
    FeatureComm 
    V/VI Handbook for CD-l 00
    Data
    FeatureComm 
    VNI User’s Manual for
    CD-1 00 Data
    OMNI FeatureComm Handbook (Voice
    Features Only)
    OMNI FeatureComm User’s Manual (Voice
    Features Only)
    FeatureComm Quick Reference Guide
    5210
    8187O-301 
    						
    							TL-130100-1001
    THIS PAGE INTENTIONALLY LEFT BLANK.
    O-3028l875210 
    						
    							 rTL-130100-1001INDEX
    .A
    Accessing Conference Bridge 2, O-191
    Account Code Entry “ACCOUNT CODE” (40) O-81
    ACD Procedures for Standard Telephone, O-261
    Agent Call Hold/Consultation, O-264
    Alarms, O-21 
    9
    Alphabetical Operation of Features, O-81
    Alphabetic Featurephone Button Programming, O-70
    Alternate Exclusion of Calling Party or Called Party When Extending Call, O-165
    Announcing Call to Station, O-164
    Answering an Incoming ACD Call, O-262
    Answering an Incoming Call, O-157Answering Incoming Line-l Call 
    (CASACD), O-265
    Answering Incoming Line-2 Call (CAS Main/ACD), O-267
    Answering Station Recall and Transferring to Inside Party, O-178
    Attendant Access, O-l 98
    Attendant Access Check of All Implemented Stations, O-214
    Attendant Call or Recall, O-16
    Attendant Call Splitting, O-21 5
    Attendant Call-Waiting Operation, 
    O-21 7
    Attendant Camp-On, O-l 74
    Attendant Camp-On Data Secure Lines, O-176
    Attendant Camp-On Not Equipped, O-177
    Attendant Code Calling, O-196
    Attendant Completes Call, O-l 87
    Attendant Conference, O-l 89
    Attendant Console, O-l 43
    Attendant Console, General, O-l 43
    Attendant Console Has Power But Is Inoperative, 
    O-156
    Attendant Console Internal Program Access, O-222
    Attendant Consults With Calling Party When Extending Call to a Busy Station, 
    O-169
    Attendant Control of Facility (ACOF), O-199
    F=TL-130000-1001 O=TL-130100-1001M=TL-130200-1001I=TL.130300-1001D=TL-130400-1001S=TL-130500-1001A=TL-100000-1001
    Features
    OperationMaintenancelnstallatlonData BaseSystem Conflguration ADMP UsersGuide 
    						
    							- --TL-130100-1001
    Attendant Denied Placing Call in Page Queue Condition, O-195
    Attendant Direct Trunk Access, O-l 98
    Attendant Handling of Locked Loop Trunk-to-Trunk Calls, O-223
    Attendant Recall, O-21 2
    Attendant Stays With Calling Party When Extending Call, O-167
    Attendant Timed Recall, O-213
    Attendant Trunk Group Restriction, O-l 98
    Audible Signals, O-49
    Audit Requests, O-295Automatic Call Announcing 
    (27), Featurephone Button Programming, O-70Automatic Callback “CAMP-ON” 
    (37), O-82
    Automatic Intercom (23), Featurephone Button Programming, O-72
    Automatic Line Seizure, O-83
    Automatic Recall From Calling 
    Party When Extending Call, O-167
    B
    Bad-Line Reporting “BAD LINE” 
    (45), O-85
    Bad Line Service (ACD), O-261
    Bad Service Line Reporting 
    (CASIACD), O-270
    Basic Calling (Internal/External), O-85
    BLDU, General, O-227
    BLDU Initialization, O-230
    BLDU Line and Trunk Group Display, Attendant Console Assignment of Hundreds
    Groups, O-230
    BLDU Operating Procedures, O-230
    Break-In, O-l 70
    Break-In Not Allowed Condition, 
    O-171
    Break-In on a Broken-In Line Condition, O-172
    Break-In on Busy Station, O-170
    Break-In on Data Secure Line Condition, O-173
    Busy Lamp Display Unit, O-227
    Busy Lamp Display Unit Access, O-224Busy Override 
    “OVRIDE” (34), O-86
    F=T~--~~oooo.IooI O=T~.130lOo-1001M=TL-130200-1001I=TL-130300-1001D=TL-130400-1001S=TL-130500-1001A-TL-100000-1001
    Features
    OperationMaintenancelnstallattonData BaseSystem Configuration ADMP Users Guide 
    						
    							Call Accounting for OMNI SI With PD-200 Data Switch, O-259
    Call Announcing “VOICE” (26, 
    27), O-87
    Called Station Does Not Answer, O-167
    Call Forward 
    (19) Featurephone Button Programming, O-72
    Call Forward “FWD” 
    (19) O-89
    Call Forwarding, O-32
    Call Forward No Answer Duration (Control Code 
    8), O-58
    Call Hold, O-24
    Call Hold (CAS 
    Main/ACD), O-270
    Call Hold “HOLD” 
    (21) O-90
    Call Park, O-25, O-21 1
    Call Park “PARK” 
    (32), O-91
    Call Pickup “PICKUP” (28, 
    29), O-94
    Call Transfer and Station Consultation, O-22
    Call Transfer to IVMS, O-163
    Call Waiting, Originating, O-26
    Call Waiting, Terminating, O-26
    Call Waiting, Toggling, O-27
    Call Waiting Queue, O-152
    Call Waiting “WAIT” 
    (30), O-95
    Camp-On, O-l 74
    Cancellation of Programming, Featurephone, O-67
    CASACD Agent Instrument (PACET) Procedures, O-265
    Change/Restore, O-46
    Clock Display (Control Code 
    5), O-59
    Clock Type (Control Code 
    6), O-59
    Code Calling, O-40, O-196
    Code Calling With Outside Party Waiting, O-197
    Conference “CONF” 
    (38), O-96
    Conferences, O-35
    Controls, Indicators, and Displays, Attendant Console, O-143
    Controls, Indicators, and Displays, KEDU, O-275
    Controls, Visual and Audible Indicators, Displays, and Messages, Featurephone, O-49
    F=TL-130000-1001O=TL-130100-1001M=TL-130200-1001I=TL-130300-1001D=TL-130400-1001S=TL-130500.1001A=TL-100000-1001
    Features
    OperationMaintenanceInstallationData BaseSystem Configuration ADMP Users Guide 
    						
    							TL-130100-1001D
    Data Link Recovery Attempts, O-221Data Protection 
    “PROT” (33), O-97
    Data Voice Switch Interface for MDR, O-259
    Day Service, O-152
    Dial Call Pickup, O-30Dial Display “D 
    DISP”, O-98
    Dictation Equipment Access, 0-39
    Directed Dial Call Pickup, O-30
    Direct Outward Dialing (DOD), O-17
    Direct Station Selection (DSS) (1 
    l), Featurephone Button Programming, O-73
    Direct Station Selection “DSS”, O-99
    Direct Trunk Access (Maintenance Station), O-44
    Displays and Messages, Featurephone, O-52
    Do Not Disturb, KEDU-Provided, O-296
    Downloading, Featurephone, O-54
    Dual Access 
    (lo), Featurephone Button Programming, O-74Dual Access “DUAL ACCESS” 
    (lo), O-101
    Dual-Function Buttons, O-49
    Dump Options Command, O-241,
    Dynamic FRL Table, O-202
    Dynamic FRL Table Display, O-202
    Dynamic FRL Table Update, O-202
    EElapsed Time “TIMER” 
    (14), O-101
    Emergency Assistance Request (CASACD), O-270
    Emergency Service, O-1 56
    Emergency Service/Supervisory Assistance, O-261
    Engineering Applications, O-259
    Entering Data, Featurephone, O-67
    Establish Conference Call for Inside Party, O-189
    Excluding Calling Party When Extending Call, O-164
    Executive Override, O-28
    F=TL-130000.1001 O=TL.l3010o-1001M=TL-130200.1001I=TL-130300-1001D=TL-130400-1001S=TL.130500-1001A=TL-100000.1001
    Features
    operationMaintenanceInstallationData BaseSystem 
    Conflguration ADMP Users Guide 
    						
    All GTE manuals Comments (0)

    Related Manuals for GTE Omni Si Database Technical Practices Issue 1 Manual