    							TL-130100-1001
    STEP
    OPERATIONRESULT
    4
    Non-priority calls are placed in
    call-waiting queue.5From any station, access code for
    priority call is dialed.
    6Terminate call in progress.
    7Depress flashing LOOP LED
    pushbutton (l-4).
    8Depress POS RLSE pushbutton.(e) Trunk and station identification cleared
    from variable display.
    (f) Class-of-service digits cleared if
    present.
    (g) TOD displayed.
    CALL WTG LED on when level 1 is
    exceeded. LED flashes if level 2 is
    exceeded.
    (a) Ringing heard at 60 IPM.
    (b) CALL WTG LED flashes at 120 IPM.
    LOOP LED (l-4) flashes at 120 IPM.
    (a) LOOP LED on.
    (b) PRIORITY CALL appears in fixed
    display.
    (c) Line number and class of service appear
    in variable display.
    (d) POS RLSE LED on.
    (e) START/STOP LED on.
    (f) Ringing stops.
    (g) Transmission established between line
    and attendant.
    (a) LOOP LED off.
    (b) POS RLSE LED off.
    (c) EXCL SRCE or EXCL DEST 
    LEDs off if
    (d) 
    Fked display cleared.
    (e) Trunk and station identification
    cleared from variable display.
    (f) Class-of-service digits cleared if
    present.
    (g) TOD displayed.
    4.39Attendant Call-Waiting Operation
    STEP
    OPERATIONRESULT
    1From several stations, Attendant
    Console dialed. Do not answer any
    calls.(a) LOOP LED flashes at 30 IPM.
    (b) When call-waiting queue reaches
    first level, CALL WTG LED goes on.
    52108187o-21 7 
    						
    							TL-130100-1001STEPOPERATIONRESULT(c) When call-waiting queue reaches
    second level, CALL WTG LED flashes
    and overflow service is alerted
    (if equipped).
    2Answer calls.(a) Calls answered in order received
    (except for priority calls which move
    to top of queue).
    (b) When CALL WTG queue is reduced
    below second level, LED goes on and
    UNA (if programmed) is canceled.
    (c) When CALL 
    WIG queue is reduced
    below level 
    1, LED goes off.
    4.40Faulty Line
    4.40.1Maintenance Print-out Operation
    STEPOPERATIONRESULT
    1Attendant called from one of station
    lines.(a) Ringing heard.
    (b) LOOP LED (l-4) flashes at 30 IPM.
    2Depress flashing LED LOOP
    pushbutton (l-4).(a) LOOP LED on steady.
    (b) “INFORMATION” appears in fixed
    .display field.
    (c) Line number appears in variable
    display field.
    (d) POS RLSE LED on.
    (e) Ringing stops.
    (f) Transmission established between
    line and attendant.
    Depress BAD LINE pushbutton.
    3(a) BAD LINE LED flashes.
    (b) System records line information on
    maintenance TTY or CRT.
    (c) BAD LINE LED on steady.
    4Depress POS RLSE pushbutton.(a) BAD LINE LED off.
    (b) LOOP LED off.
    (c) POS RLSE LED off.
    (d) TOD displayed.
    0-218
    81875210 
    						
    							_ :-TL-130100-1001
    4.40.2Invalid Operation
    STEPOPERATIONRESULT
    1Attendant called from one of station
    lines.
    2Depress flashing LOOP LEDpushbutton (l-4).
    3Depress START/STOP pushbutton.
    4Depress BAD LINE pushbutton.
    5Depress POS RLSE pushbutton.(a) Ringing heard.
    (b) LOOP LED flashes at 30 IPM.
    (a) LOOP LED on.(b) “INFORMATION” appears in fixed
    display field.(c) Line number appears in variable
    display field.
    (d) POS RLSE LED on.
    (e) Ringing stops.(f) Transmission established between
    line and attendant.
    (a) START/STOP LED on.
    (b) EXCL SRCE LED on.
    (c) Dial tone heard.
    (d) Line placed on hold.
    (a) BAD LINE LED flashes.(b) System does NOT record line
    information on the maintenanceTTY or CRT.
    (a) BAD LINE LED off.
    (b) LOOP LED off.
    (c) POS RLSE LED off.
    (d) TOD displayed.
    4.41
    4.41.1Alarms
    System initialization Alarm
    STEPOPERATIONRESULT
    1Bring up Attendant Console for
    service.ALARM LED flashes at 60 IPM.
    2Depress ALARM pushbutton.If present, fault message displayed in
    variable display field.
    3Repeat Step 2 until ALARM LED
    ceases to flash.Results same as Step 2 or LED off.
    5210
    Em7o-2-l 9 
    						
    							-TL-130100-1001
    4.41.2
    No Dial Alarm Directed to Attendant
    STEPOPERATIONRESULT
    1Station assigned no dial alarm feature
    (data base option).
    2Assigned station left off-hook without(a) After time out period, ringing heard.
    dialing.(b) LOOP LED (l-4) flashes at 60 IPM.
    3Depress the flashing LOOP LEDpushbutton (l-4).(a) LOOP LED on steady.(b) “NO DIAL ALARM” displays in fixed
    display field.
    (c) POS RLSE LED on.
    (d) START/STOP LED on.
    (e) Ringing stops.(f) Transmission established between
    off-hook station and Attendant
    Console.
    4.42
    Removal of Headset During Operation
    STEPOPERATIONRESULT
    1Attendant is called from any equipped(a) Station receives ringback tone.
    station.(b) Ringing heard.
    (c) LOOP LED flashes at 30 IPM.
    2Depress the flashing LOOP LED
    pushbutton.(a) LOOP LED on.
    (b) Station number appears in variable
    display field.(c) Station class of service displayed in
    variable display.(d) “INFORMATION” displayed in fixed
    display field.
    (e) Transmission established between
    attendant and station.
    (f) START/STOP LED on.
    (g) POS RLSE LED on.
    3Remove the headset from Attendant
    Console.(a) STAFFED LED off.(b) All lit 
    LEDs off.
    (c) Transmission interrupted to station.(d) Attendant Console functions in 
    Nl mode
    of night answer function.
    O-220
    8l875210 
    						
    							TL-130100-1001
    STEP
    OPERATIONRESULT
    (e) Attendant Console available for self-test diagnostics, internal program
    access.
    4.43
    Data Link Recovery Attempts
    STEP
    OPERATIONRESULT
    1Attendant Console called from
    station.
    2Depress the flashing LOOP LED
    pushbutton.
    3
    4
    5Depress NITE ANSW pushbutton. Power to Attendant Console turned(a) All lit 
    LEDs off.
    OFF.(b) Transmission interrupted to station.
    Power to the Attendant Console
    turned ON.(a) Requests to be initialized.
    (b) Verify all queued up messages
    dropped cleanly.
    (c) Ensure any call stores or digit stores
    used are returned to idle list.
    (d) 
    NITE ANSW LED on.
    (e) “NIGHT ANSWER 
    1” appears in fixed
    display. (a) 
    Ringback tone heard.
    (b) Ringing heard.
    (c) LOOP LED flashes at 30 IPM.
    (a) LOOP LED on.
    (b) Station number appears in variable
    display field.
    (c) Station class of service displayed in
    variable display.
    (d) “INFORMATION” displayed in fixed
    display field.
    (e) Transmission established between
    attendant and station.
    (f) START/STOP LED on.
    (g) POS RLSE LED on.
    (f) ALARM LED flashes.
    (a) 
    NITE ANSW LED off.
    (b) Fixed display cleared.
    (c) STAFFED LED flashes.
    (d) TOD displayed (within 60 seconds).
    (e) Call returns to console. LOOP LED
    flashes.
    52108h37o-221 
    						
    							TL-130100-1001NOTE:A call placed to the Attendant Console can ring and flash the LOOP LED even
    though Attendant Console is in night answer mode.
    4.44Attendant Console Internal Program Access
    Refer to Section TL-130200-1001 for procedures.
    4.45Initialization and De-Initialization of Attendant Console via
    Request
    STEPOPERATIONRESULT
    1Place Attendant Console in service
    via maintenance.
    5
    Insert headset.
    Remove headset.
    Place Attendant Console out of
    service via maintenance request.
    Return to Step 1 to bring Attendant
    Console back on line; stop after
    Step 2.(a) INITIALIZATION LED flutters for
    approximately 30 seconds.
    (b) When initialization is finished, thefollowing occur:
    1. Initialization LED goes off.
    2. ALARM LED flashes.
    STAFFED LED on steady.
    STAFFED LED off.
    (a) Verify Attendant Console out of service.(b) All displays and 
    LEDs off.
    4.46Spare Key Access
    STEPOPERATIONRESULT
    Depress idle LOOP pushbutton(l-4).
    Depress SPARE pushbutton.(a) LOOP LED on.
    (b) POS RLSE LED on.No noticeable change should occur to
    Attendant Console.
    3Depress POS RLSE pushbutton.(a) LOOP LED off.
    (b) POS RLSE LED off.
    (c) Fixed display field cleared.
    (d) TOD displayed.
    o-222
    81875210 
    						
    							TL-130100-1001
    STEPOPERATIONRESULT4Repeat Step 2 while performing otherDepressing SPARE pushbutton should not
    tests.influence the instrument or switch.
    NOTE:
    Data Base programmable.
    4.47Attendant Handling of Locked Loop Trunk-to-Trunk Calls
    STEPOPERATIONRESULT
    1
    2
    34
    5
    6
    5210Incoming CO trunk call with no
    disconnect supervision placed to
    appropriate number.(a) Ringing heard.
    (b) LOOP LED (l-4) flashes at 120 IPM.
    Depress the flashing LOOP LED
    pushbutton (l-4).
    Dial trunk group access code for
    outgoing trunk that does not
    guarantee disconnect supervision.
    Dial outside station number.
    Answer call at outside station.
    Depress POS RLSE pushbutton.
    8187(a) LOOP LED on steady.
    (b) “LOCAL” appears in fixed display field.
    (c) Trunk number appears in variable
    display field.
    (d) POS RLSE LED on.
    (e) START/STOP LED on.
    (f) Ringing stops.
    (g) Transmission established between
    trunk and the attendant.
    (a) EXCL SRCE LED on.
    (b) Fixed display cleared.
    (c) Trunk placed on hold in 
    exclude-source state.
    (d) CO dial tone and, optionally, tick
    tone heard.
    (e) Dialed digits appear on fixed display.
    (a) CO 
    ringback tone heard.
    (b) Dialed digits appear on fixed display.
    (a) 
    Ringback tone stops.
    (b) Private conversation allowed between
    attendant and second trunk.
    (a) POS RLSE LED off.
    (b) START/STOP LED off.
    (c) LOOP LED winks at 30 IPM.
    (d) EXCL SRCE LED off.
    (e) Fixed display goes off.
    (f) Transmission established between
    trunks.
    O-223 
    						
    							TL-130100-1001
    NOTE:After a period of time, perform trunk busy verification and Break-In on either trunk.
    If trunks are not busy (reorder tone, quiet, etc.), perform a Forced Trunk Release on
    either trunk to break connection.
    4.48Busy Lamp Display Unit Access
    STEPOPERATIONRESULT1
    2NOTES:
    1.
    2.Depress BLDU pushbutton.Enter Hundreds Group number displayed in
    fixed display field.
    Enter a 2-digit Hundreds Group
    number (00-99).(a) Number entered displayed in fixed
    display field.
    (b) If BLDU attached, status of Hundreds
    Group entered displayed on BLDU.
    (c) Fixed display is cleared.’
    (d) TOD displayed.
    If any pushbutton on the Attendant Console other than the BLDU pushbutton and the
    keypad is depressed after Step 1,“DIGIT ENTRY ONLY” is displayed in the
    Attendant Console fixed display field. When this occurs, enter a 2-digit Hundreds
    Group number and Step 2 results are completed.
    If the BLDU pushbutton is depressed again after Step 1, the TOD is displayed on the
    Attendant Console and the BLDU function is canceled.
    4.49Second Chime
    STEP
    OPERATIONRESULT
    1Station calls Attendant Console.(a) Ringback tone is heard.
    (b) Chime is heard.
    (c) LOOP LED flashes at 30 IPM
    2Depress the flashing LOOP LED
    pushbutton.
    O-2248l87(a) LOOP LED on steady.
    (b) Station number appears in the variable
    display field.
    (c) Station class of service is displayed in
    the variable display.
    (d) Information is displayed in the fixed
    display field.
    (e) START/STOP and POS RLSE 
    LEDs on.
    (f) Transmission allowed between attendant
    and station.
    5210 
    						
    							TL-130100-1001OPERATIONRESULT
    3Station calls Attendant Console.(a) Ringback tone is heard.
    (b) Chime is heard.
    (c) LOOP LED flashes at 30 IPM.
    5210