    							Presets and System setup
    Vivid7/Vivid7 PRO Users Manual397
    FC092326-03
    Imaging
    • Global: enables the user to configure display-related 
    settings.
    • Application: enables configuration of the probe and 
    application specific settings.
    • Application menu: enables configuration of the 
    Measurement menu.
    The Global setup sheet
     Figure 12-3: The Global setup sheet 
    						
    							Presets and System setup
    398Vivid7/Vivid7 PRO Users Manual
    FC092326-03
    Cineloop store
    Crop images
    Doppler
    Parameter Description
    Cineloop store:
    • Time before/after heart cycle: sets the total 
    storage time span of the cineloop in ECG 
    mode.
    • Time span (no ECG): sets the total storage 
    time span of the cineloop with no ECG.
    • Preview loop before store: when selected 
    enable review of cineloops before storage.
    Parameter Description
    Crop images:
    : In the Analysis screen, removes top and 
    bottom of the image when more than two 
    images have been selected.
    Parameter Description
    Doppler:
    • Show KHz scale: when selected, displays 
    the KHz scale on the left side of the Doppler 
    spectrum (see page 112). 
    						
    							Presets and System setup
    Vivid7/Vivid7 PRO Users Manual399
    FC092326-03
    Patient Info
    Scan Info
    Parameter Description
    Patient Info:
    • Title bar Line 1 & 2: selects from the 
    pop-up menu the patient information 
    to display on the scanning screens 
    Title bar (see page 52).
    • Anonymous patient: when checked, 
    no patient information is displayed on 
    the scanning screens Title bar.
    Parameter Description
    Scan Info:
    •  : displays scan information on the 
    video record. 
    						
    							Presets and System setup
    400Vivid7/Vivid7 PRO Users Manual
    FC092326-03
    Application
    The Application category enables the configuration of probe/
    application specific settings (presets). The application-specific 
    settings can be stored and used as default presets with this 
    probe.
     Figure 12-4: The Application setup sheet (example) 
    						
    							Presets and System setup
    Vivid7/Vivid7 PRO Users Manual401
    FC092326-03
    The Probe/application configuration parame-
    ters
    Parameter Description
    Image Store settings:
    •  Single frame (live store):
    : Store cineloop.
    : Store single frame image only.
    •  Number of heart cycles:
    Select the number of heart cycles to 
    store (Single frame must be 
    unchecked).
    Auto freeze:
    • Freeze 2D image in Doppler: the last 
    2D or color flow image is displayed 
    when entering in Doppler mode.
    • Auto freeze after: sets the time after 
    which the system enters in freeze when 
    not in use.
    Footswitch functionality:
    Configures the footswitch pedal for the 
    selected application.
    Select the operation to perform for each 
    pedal from the associated Pedal pop-up 
    menu.
    Templates and Packages:
    Defines the default stress protocol 
    associated to the application.
    Select the default Protocol to be 
    associated to the selected application 
    from the pop-up menu.
    Auto invert on steer:
    In Color flow, the color bar is inverted 
    when steering the color flow sector angle. 
    						
    							Presets and System setup
    402Vivid7/Vivid7 PRO Users Manual
    FC092326-03
    Create a new Application
    The application created is probe dependant. Select the desired 
    probe before configuring a new application.
    1. Press 
    APPLICATION on the Control panel.
    2. Trackball to Preset... in the Application pop-up menu.
    The Application setup sheet (see Figure 12-4) is displayed.
    3.Adjust the parameters as desired (see page 401).
    4. Press New.
    A Dialogue window is displayed.
    5.Enter a name for the new application.
    6. Press OK
    To edit an application
    1. Press APPLICATION and select the application to edit.
    2. Press 
    APPLICATION again.
    3. Trackball to Preset... in the Application pop-up menu.
    The Application setup sheet (see Figure 12-4) is displayed.
    4. Change the parameters as desired (see page 401).
    5. Press Save to store the changes.
    Applicable only on user-defined applications.
    Create new application:
    Press New to create a new Application. A 
    dialogue window is displayed where the 
    operator is asked to give a name to the 
    new application.
    Remove current application:
    Press Delete to remove the current 
    application. Factory Application settings 
    cannot be deleted.
    Save image/appl. settings
    Press Save to store the changes applied 
    to the current setting. Not applicable on 
    factory application settings. Parameter Description 
    						
    							Presets and System setup
    Vivid7/Vivid7 PRO Users Manual403
    FC092326-03
    Deletion of an Application
    1. Press APPLICATION and select the application to delete.
    2. Press 
    APPLICATION again.
    3. Trackball to Preset... in the Application pop-up menu.
    The Application setup sheet (see Figure 12-4) is displayed.
    4. Press Delete to remove the selected application. 
    						
    							Presets and System setup
    404Vivid7/Vivid7 PRO Users Manual
    FC092326-03
    Application menu
    The Application menu category enables rearrangement of the 
    the Application menu to best suit the users requirements.
    The Application menu is a two-levels pop-up menu. The first 
    level called Application, displays the most frequently used 
    applications in any desired order. The second level called 
    More... displays the less frequently used applications.
     Figure 12-5: The Application menu setup sheet (example)
    1. First menu level
    2. Second menu level3. Moving tools 
    						
    							Presets and System setup
    Vivid7/Vivid7 PRO Users Manual405
    FC092326-03
    Configuration of the Application menu
    The Application menu can be configured by moving the 
    applications up and down inside the pop-up menu and from 
    one level to the other.
    To move an application inside one level
    1. Trackball to the application to move.
    2. Press 
    SELECT.
    3. Press .
    The application is moved one step up.
    Press Default to 
    get factory setting.4. Press .
    The application is moved one step down.
    To move an application from one level to the other
    1. Trackball to the application to move.
    2. Press 
    SELECT.
    3. Press as many times as necessary:
    •   if the application to move is in the More menu
    •   if the application to move is in the Applications menu
    till the application has moved to the other menu. 
    						
    							Presets and System setup
    406Vivid7/Vivid7 PRO Users Manual
    FC092326-03
    Measure
    The Measure setup category enables the organization of the 
    Factory default Measurement menu or the creation of user-
    defined Measurement menus to best suit the users 
    requirements. 
     Figure 12-6: The Measurement menu setup sheet
    1. Configuration window (see next pages for 
    details)2. The measurement menu (displays updated 
    configuration) 
    						
    All GE manuals Comments (0)

    Related Manuals for GE Vivid 7 User Manual