Scanning Modes Vivid7/Vivid7 PRO Users Manual97 FC092326-03 Using 2D Refer to page 400 about creating pre- sets.The 2D-Mode is the systems default mode. 1. Press 2D on the control panel to access 2D mode. Check the Displays brightness and con- trast setting before adjusting the unit imaging controls2. Optimize the image by adjusting the image controls described in the previous section. If necessary use preset for optimum performance with minimum adjustment. Optimizing 2D The following controls can be adjusted to optimize the 2D Mode display: • Use the Gain and TGC controls to optimize the overall image. • Use the Depth control to adjust the range to be imaged. • Use the Focus control to center the focal point(s) around the region of interest. • Use the Frequency (move to higher frequencies) or the Frame rate control (move to lower frame rate) to increase resolution in image • Use the Frequency (move to lower frequency) to increase penetration. • Use the Reject control to reduce noise in the image. • Use the DDP control to optimize imaging in the blood flow regions and make a cleaner, less noisy image. WARNINGAlways use the minimum power required to obtain acceptable images in accordance with applicable guidelines and policies.
Scanning Modes 98Vivid7/Vivid7 PRO Users Manual FC092326-03 M-Mode M-Mode over view Figure 3-3: The cardiac M-Mode screen (top/bottom) 1. Time motion cursor conventional M- Mode 2. Time motion cursor curved anatomical M-Mode 3. Time motion cursor anatomical M-Mode 4. Depth scale 5. Focus marker 6. Time scale 7. Status window: 8. Soft menu
Scanning Modes Vivid7/Vivid7 PRO Users Manual99 FC092326-03 Figure 3-4: The M-Mode controls on the front panel This unit has three types of M-Mode: • Conventional M-Mode (MM): displays a distance/time plot of a cursor line in the axial plane of the 2D-image. • Anatomical M-Mode (AMM): displays a distance/time plot from a cursor line, which is independent from the axial plane. AMM is available in greyscale, color, TVI, Tissue Tracking, Strain rate and Strain modes. • Curved Anatomical M-Mode (CAMM): displays a distance/ time plot from a free-drawn cursor line. CAMM is available in greyscale, color, TVI, Tissue Tracking, Strain rate and 1. Assignable keys: • Horizontal sweep R • Frequency/Resolution • Focus • Contour • Up/Down • Color maps 2. Zoom 3. Img Size 4. Soft menu • Compress R • Reject R • Dynamic Range • Power 5. Freeze 6. M-Mode 7. Access to AMM & CAMM 8. Gain R Controls marked with R are also available in freeze and cine replay 1 2 3 4 5 6 8 7
Scanning Modes 100Vivid7/Vivid7 PRO Users Manual FC092326-03 Strain modes. M-Mode and 2D Mode display areas can be side by side or top/ bottom. Conventional M-Mode can be combined with Color (see ’Color M-Mode overview’ on page 105). M-Mode controls M-Mode assignable controls Horizontal sweep Adjusts the horizontal refresh rate of the M-Mode area of the display. Horizontal sweep does not change the acquisition resolution, so that user can change the horizontal sweep in replay (with no loss of quality). On some low fre- quencies, the sys- tem switches automatically to second-harmonic mode. The word “Octave” appears in the status win- dow.Frequency/Resolution Enables the adjustment of the probes operating frequency. Rotate the knob clockwise to increase the frequency. The selected frequency is displayed in the status window. For some probes/applications the lowest frequency settings will be Octave imaging settings. Focus Changes the location of the focal point(s). A triangular focus marker indicates the depth of the focal point. Contour Controls image processing related to the extent of edge enhancement applied to an image. Up/Down Flips the M-Mode display 180 degrees. Color maps Displays a color map menu to optimize the greyscale presentation. The menu enables an option from a list of non- linear gray-curves or different colorized curves to be selected.
Scanning Modes Vivid7/Vivid7 PRO Users Manual101 FC092326-03 M-Mode Soft menu controls Compress Controls the amount of contrast in the image. An index number is displayed in the status window to indicate the relative level of compression. Reject Adjust reject level. When this control is increased, low-level echoes are rejected and appear darker in the image. An index number is displayed in the status window to indicate the relative level of rejection. Power When power is re- duced, it reduces the signal-to-noise ratio, so that the im- age, spectrum or color scan may be- come noisier.Controls the amount of acoustic power applied in all modes. When power is set to maximum, it is equal to or less than the maximum acoustic power permitted by the FDA. The Thermal Index (TI) and the Mechanical Index (MI) are displayed on the screen. Dynamic Range Enables control of the dynamic range or contrast of the image. When dynamic range is set to High, the image is softer and more low-level data is visible.
Scanning Modes 102Vivid7/Vivid7 PRO Users Manual FC092326-03 Using M-Mode Conventional M-Mode 1. To access M-Mode from any other scan mode, press MM on the control panel. 2. Use the trackball to position the cursor over the required area of the image. Gain, Frequency, Focus, Dynamic Range and Com- pression affect also the 2D image.3. Adjust horizontal sweep, Gain, Frequency, Focus, Dynamic Range, Compression and Contour to optimize the display if necessary. 4. Press FREEZE to stop imaging. Anatomical M-Mode Anatomical M- Mode can also be used with previous- ly acquired digitally stored 2D images.1. From the 2D Live or M-Mode view, press ALT. The alternative modes are displayed on the assignable. 2. Press AMM OR 1. From the 2D Live, press FREEZE. 2. Press MM to access the Anatomical M-Mode. The Trackball as- signable Pos (Posi- tion) is activated.3. Use the trackball to position the cursor over the required area of the image. The Trackball as- signable Angle is activated.4. Press TRACKBALL to allow free rotation of the solid full- length cursor line throughout the 2D image. 5. Rotate the solid cursor line to the desired direction. The Trackball as- signable Pos is acti- vated.6. Press TRACKBALL twice and reposition the intersection point to the desired position along the cursor line. 7. Repeat steps 4. and 5. to change the angle of the solid cursor line if necessary. The M-Mode area of the display updates as the M-Mode sig- nal is constructed.8. Press TRACKBALL to activate scrolling control on the trackball. 9. Use the trackball to scroll through the data acquired at that location. The M-Mode display will vary accordingly. Cur ved Anatomical M-Mode Curved Anatomi- cal M-Mode can al- so be used with previously ac- quired digitally stored 2D images.1. From the 2D or M-Mode view press ALT. The alternative modes appear on the assignable display. 2. Press CURVED AMM.
Scanning Modes Vivid7/Vivid7 PRO Users Manual103 FC092326-03 3. Use the trackball to position the starting point of the time motion curve. The time motion curve can be edited by following the curve back to the de- sired point and re- drawn as desired. Following the curve back to the starting point will delete the time motion curve.4. Press SELECT to anchor the starting point of the time motion curve. 5. Use the trackball to position the second point of the time motion curve. 6. Press SELECT to anchor the second point of the time motion curve. 7. Repeat step 5. and 6. up to seven times to draw a complete time motion curve. Optimizing M-Mode Refer to page 400 about creating pre- sets.The use of preset gives optimum performance with minimum adjustment. If necessary, the following controls can be adjusted to further optimize the M-Mode display: • Adjust Horizontal sweep to optimize the display resolution. • Adjust Gain and TGC controls to adjust the range to be imaged. Except for Con- tour, all the con- trols listed in the optimizing M- Mode section will also affect the 2D image.• Use the Frequency (move to higher frequencies) or the Frame rate control (move to lower frame rate) to increase resolution in image. • Use the Frequency (move to lower frequency) to increase penetration. • Adjust Focus to move the focal point(s) around the region of interest in the M-Mode display. • Adjust Dynamic range to optimize the useful range of incoming echoes to the available greyscale. • Adjust Compress and Contour to further optimize the display. • Adjust Reject to reduce noise while taking care not to eliminate significant low-level diagnostic information.
Scanning Modes 104Vivid7/Vivid7 PRO Users Manual FC092326-03 Color Mode Color 2D Mode over view Figure 3-5: The Color Mode screen 1. Probe orientation marker 2. Color bar 3. Color sector marker 4. Status window: 5. Soft menu Controls marked with R are also available in freeze and cine replay.
Scanning Modes Vivid7/Vivid7 PRO Users Manual105 FC092326-03 Color M-Mode over view Figure 3-6: The Color M-Mode screen (top/bottom display) 1. Time motion cursors 2. Color bar 3. Focus marker 4. Flow sector marker 5. Time scale 6. Status window: 7. Soft menu Controls marked with R are also available in freeze and cine replay.
Scanning Modes 106Vivid7/Vivid7 PRO Users Manual FC092326-03 Figure 3-7: The Color Mode controls on the front panel 1. Assignable keys: • Horizontal sweep (Color M-Mode only) R • Scale • LVR • Invert R • Variance R • Dual focus • Color maps • Angio (Color 2D only) • Cineloop (in Freeze, Color 2D mode only) 2. Zoom • Display zoom • HR zoom 3. Img Size (Color M- Mode) 4. Soft menu • Sample Volume • Tissue Priority R • DDP (Color 2D only) R • Frequency • Radial avg. • Lateral avg. • Power 5. Freeze 6. Color 7. Access to AMM & CAMM 8. Gain R Controls marked with R are also available in freeze and cine replay 6 1 2 5 4 3 8 7