Home > GE > Ultrasound System > GE Vivid 7 User Manual

GE Vivid 7 User Manual

    Download as PDF Print this page Share this page

    Have a look at the manual GE Vivid 7 User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 45 GE manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 536
    							Archiving
    Vivid7/Vivid7 PRO Users Manual317
    FC092326-03
    • MPEGvue: converts ultrasound images to MPEG format 
    readable from a regular computer and export them to a 
    CD. 
    6. Press OK.
    The Export patient window is displayed (see Figure 8-28).
     Figure 8-28: The Export patient window
    7. Search and Select the patient records/examinations to 
    export in the Patient list.
    The following selection methods can be used: 
    •  Press and hold down 
    SHIFT while selecting patient 
    records/examinations to select several consecutive 
    items at a time.
    •  Press and hold down 
    CTRL while selecting patient 
    records/examinations to select several discrete items.
    • Press Select all in the Export patient window to export 
    all patient records. 
    						
    							Archiving
    318Vivid7/Vivid7 PRO Users Manual
    FC092326-03
    Press More to dis-
    play the extended 
    Export patient 
    window if neces-
    sary.• Press Today to display todays examinations and select 
    the actual examinations.
    • Fill in the Exam between field to display the patient 
    records done during a specific time period and select the 
    actual records.
    • Fill in the Born between field to display the patient 
    records of patients born during a specific time period and 
    select the actual records.
    8. Adjust the following settings as desired:
    • Delete selected patient(s) after copy
    • Copy images
    • Copy only exams with on-line images: when checked 
    only selected examinations with accessible images will 
    be copied.
    9. Press Copy.
    If one or more patient examination is already present in the 
    destination archive the Export/Import conflict window is 
    displayed (see Figure 8-29). For each conflicting item, 
    select:
    Keep: to keep the existing examination in the destination 
    archive.
    Replace: to replace the existing examination with the 
    corresponding item in the source archive. 
    						
    							Archiving
    Vivid7/Vivid7 PRO Users Manual319
    FC092326-03
     Figure 8-29: The Export/Import conflict window
    Press OK to resume export.
    A progress indicator is displayed. When done a status 
    window is displayed showing the number of patient records 
    that have been successfully exported.
    10. Press OK.
    A check mark is displayed in the Copied field in the Export 
    patient window for each item exported.
    A status message is displayed for each item exported. 
    Make sure that the operation was successful for each item 
    exported.
    11. Press Done in the Export patient window to complete the 
    process.
    Do not eject the CD 
    using the button on 
    the CD drive12. Press ALT+E to eject the disk.
    The Eject device menu is displayed. 
    						
    							Archiving
    320Vivid7/Vivid7 PRO Users Manual
    FC092326-03
     Figure 8-30: The Eject device menu
    13. Select the relevant media.
    The selected removable media is ejected. 
    						
    							Archiving
    Vivid7/Vivid7 PRO Users Manual321
    FC092326-03
    Impor ting patient records/examinations
    1. Insert the removable media of the source archive in the 
    corresponding drive (MO drive or CD-ROM).
    2. Press 
    ARCHIVE on the Front panel.
    The Search/Create Patient window is displayed (Figure 8-
    7, page 280).
    3. Select destination archive in the Dataflow field: 
    • LocalArchive-Int.HD: imports data to the local archive.
    • RemoteArch-RemoteHD: imports data to an Echo 
    server (network) or an EchoPAC PC (direct connect).
    4. Press Import in the Search/Create Patient window.
    The Import dialogue window is displayed (see Figure 8-
    31).
     Figure 8-31: The Import Dialogue window
    5. Select one of the following source archive from the Source 
    drop-down menu:
    • Removable MOD Archive: imports raw and DICOM 
    data (if present) from a MOD.
    • Pure DICOM MOD525: imports DICOM data only from 
    a MOD.
    • Removable CD Archive: imports raw and DICOM data 
    (if present) from a CD-R.
    • Pure DICOM CD-R: imports DICOM data only from a 
    CD-R.
    • Remote Import/Export Archive: imports raw and 
    DICOM (if present) data from an Echo server (network)  
    						
    							Archiving
    322Vivid7/Vivid7 PRO Users Manual
    FC092326-03
    or EchoPAC PC (direct connect or network).
    • Query Retrieve: imports data from a DICOM server.
    6. Press OK.
    The Import patient window is displayed (see Figure 8-32).
     Figure 8-32: The Import patient window
    7. Search and select the patient records to import in the 
    Patient list.
    The following selection methods can be used: 
    •  Press and hold down 
    SHIFT while selecting patient 
    records/examinations to select several consecutive 
    items at a time.
    •  Press and hold down 
    CTRL while selecting patient 
    records/examinations to select several discrete items.
    • Press Select all in the Import patient window to export 
    all patient records. 
    						
    							Archiving
    Vivid7/Vivid7 PRO Users Manual323
    FC092326-03
    Press More to dis-
    play the extended 
    Import patient 
    window if neces-
    sary.• Press Today to display todays examinations and select 
    the actual examinations.
    • Fill out the Exam between field to display the patient 
    records done during a specific time period and select the 
    actual records.
    • Fill out the Born between field to display the patient 
    records of patients born during a specific time period and 
    select the actual records.
    8. Adjust the following settings as desired:
    • Copy images
    • Copy only exams with on-line images: when checked 
    only selected examinations with accessible images will 
    be copied.
    9. Press Copy.
    If one or more patient examination is already present in the 
    destination archive the Export/Import conflict window is 
    displayed (see Figure 8-29). For each conflicting item, 
    select:
    Keep: to keep the existing examination in the destination 
    archive.
    Replace: to replace the existing examination with the 
    corresponding item in the source archive. 
    						
    							Archiving
    324Vivid7/Vivid7 PRO Users Manual
    FC092326-03
     Figure 8-33: The Export/Import conflict window
    Press OK to resume import.
    A progress indicator is displayed. When done a status 
    window is displayed showing the number of patient records 
    that have been successfully imported.
    10. Press OK.
    A check mark is displayed in the Copied field in the Import 
    patient window for each item imported.
    A status message is displayed for each item imported. 
    Make sure that the operation was successful for each item 
    imported.
    11. Press Done in the Import patient window to complete the 
    process. 
    						
    							Archiving
    Vivid7/Vivid7 PRO Users Manual325
    FC092326-03
    DICOM spooler
    DICOM spooler displays the current DICOM output jobs. The 
    jobs may be Storage, Print, Modality Performed Procedure 
    Step or Storage Commitment. The DICOM spooler is used for 
    checking the current jobs status when a job is saved or when 
    the total spooler status on the right of the Archive windows 
    displays an error. 
    From the DICOM spooler the user can also:
    • Delete non-active jobs
    • Resend a job that has failed or is in hold
    • Send a job that has failed or is in hold, to a new destination.
    The jobs status displayed in the DICOM spooler window can 
    be:
    • Pending: the job is complete, waiting to be active.
    • In hold: the job is incomplete, waiting for more images.
    • Append: the job is connected to the destination device but 
    is waiting for more images (Direct store function).
    • Active: the job is complete and connected to the 
    destination device.
    • Failed: the job is complete but one or more images failed to 
    transmit to the destination device.
    • Done: the job is saved to the destination device. The jobs 
    that are done are removed from the spooler after a while.
    Star ting the DICOM spooler
    Alternative: Press 
    F4.
    1. On the alphanumeric keyboard, press and hold down the 
    ALT key and press S.
    The DICOM spooler window is displayed (see Figure 8-
    34).
    The DICOM spooler window is automatically updated every 
    minute. Press Refresh to update the information displayed at 
    any time. 
    						
    							Archiving
    326Vivid7/Vivid7 PRO Users Manual
    FC092326-03
     Figure 8-34: The DICOM job spooler window
    Deleting a job
    Only non-active 
    jobs can be deleted.1. Trackball to the job to delete in the DICOM job spooler 
    window.
    2. Press 
    SELECT.
    3. Trackball to Delete.
    4. Press 
    SELECT.
    Resending a job
    Only jobs that 
    failed or are in hold 
    can be resent.1. Trackball to the job to re-send in the DICOM job spooler 
    window.
    2. Press 
    SELECT.
    3. Trackball to Resend.
    4. Press 
    SELECT. 
    						
    All GE manuals Comments (0)