Archiving Vivid7/Vivid7 PRO Users Manual317 FC092326-03 • MPEGvue: converts ultrasound images to MPEG format readable from a regular computer and export them to a CD. 6. Press OK. The Export patient window is displayed (see Figure 8-28). Figure 8-28: The Export patient window 7. Search and Select the patient records/examinations to export in the Patient list. The following selection methods can be used: • Press and hold down SHIFT while selecting patient records/examinations to select several consecutive items at a time. • Press and hold down CTRL while selecting patient records/examinations to select several discrete items. • Press Select all in the Export patient window to export all patient records.
Archiving 318Vivid7/Vivid7 PRO Users Manual FC092326-03 Press More to dis- play the extended Export patient window if neces- sary.• Press Today to display todays examinations and select the actual examinations. • Fill in the Exam between field to display the patient records done during a specific time period and select the actual records. • Fill in the Born between field to display the patient records of patients born during a specific time period and select the actual records. 8. Adjust the following settings as desired: • Delete selected patient(s) after copy • Copy images • Copy only exams with on-line images: when checked only selected examinations with accessible images will be copied. 9. Press Copy. If one or more patient examination is already present in the destination archive the Export/Import conflict window is displayed (see Figure 8-29). For each conflicting item, select: Keep: to keep the existing examination in the destination archive. Replace: to replace the existing examination with the corresponding item in the source archive.
Archiving Vivid7/Vivid7 PRO Users Manual319 FC092326-03 Figure 8-29: The Export/Import conflict window Press OK to resume export. A progress indicator is displayed. When done a status window is displayed showing the number of patient records that have been successfully exported. 10. Press OK. A check mark is displayed in the Copied field in the Export patient window for each item exported. A status message is displayed for each item exported. Make sure that the operation was successful for each item exported. 11. Press Done in the Export patient window to complete the process. Do not eject the CD using the button on the CD drive12. Press ALT+E to eject the disk. The Eject device menu is displayed.
Archiving 320Vivid7/Vivid7 PRO Users Manual FC092326-03 Figure 8-30: The Eject device menu 13. Select the relevant media. The selected removable media is ejected.
Archiving Vivid7/Vivid7 PRO Users Manual321 FC092326-03 Impor ting patient records/examinations 1. Insert the removable media of the source archive in the corresponding drive (MO drive or CD-ROM). 2. Press ARCHIVE on the Front panel. The Search/Create Patient window is displayed (Figure 8- 7, page 280). 3. Select destination archive in the Dataflow field: • LocalArchive-Int.HD: imports data to the local archive. • RemoteArch-RemoteHD: imports data to an Echo server (network) or an EchoPAC PC (direct connect). 4. Press Import in the Search/Create Patient window. The Import dialogue window is displayed (see Figure 8- 31). Figure 8-31: The Import Dialogue window 5. Select one of the following source archive from the Source drop-down menu: • Removable MOD Archive: imports raw and DICOM data (if present) from a MOD. • Pure DICOM MOD525: imports DICOM data only from a MOD. • Removable CD Archive: imports raw and DICOM data (if present) from a CD-R. • Pure DICOM CD-R: imports DICOM data only from a CD-R. • Remote Import/Export Archive: imports raw and DICOM (if present) data from an Echo server (network)
Archiving 322Vivid7/Vivid7 PRO Users Manual FC092326-03 or EchoPAC PC (direct connect or network). • Query Retrieve: imports data from a DICOM server. 6. Press OK. The Import patient window is displayed (see Figure 8-32). Figure 8-32: The Import patient window 7. Search and select the patient records to import in the Patient list. The following selection methods can be used: • Press and hold down SHIFT while selecting patient records/examinations to select several consecutive items at a time. • Press and hold down CTRL while selecting patient records/examinations to select several discrete items. • Press Select all in the Import patient window to export all patient records.
Archiving Vivid7/Vivid7 PRO Users Manual323 FC092326-03 Press More to dis- play the extended Import patient window if neces- sary.• Press Today to display todays examinations and select the actual examinations. • Fill out the Exam between field to display the patient records done during a specific time period and select the actual records. • Fill out the Born between field to display the patient records of patients born during a specific time period and select the actual records. 8. Adjust the following settings as desired: • Copy images • Copy only exams with on-line images: when checked only selected examinations with accessible images will be copied. 9. Press Copy. If one or more patient examination is already present in the destination archive the Export/Import conflict window is displayed (see Figure 8-29). For each conflicting item, select: Keep: to keep the existing examination in the destination archive. Replace: to replace the existing examination with the corresponding item in the source archive.
Archiving 324Vivid7/Vivid7 PRO Users Manual FC092326-03 Figure 8-33: The Export/Import conflict window Press OK to resume import. A progress indicator is displayed. When done a status window is displayed showing the number of patient records that have been successfully imported. 10. Press OK. A check mark is displayed in the Copied field in the Import patient window for each item imported. A status message is displayed for each item imported. Make sure that the operation was successful for each item imported. 11. Press Done in the Import patient window to complete the process.
Archiving Vivid7/Vivid7 PRO Users Manual325 FC092326-03 DICOM spooler DICOM spooler displays the current DICOM output jobs. The jobs may be Storage, Print, Modality Performed Procedure Step or Storage Commitment. The DICOM spooler is used for checking the current jobs status when a job is saved or when the total spooler status on the right of the Archive windows displays an error. From the DICOM spooler the user can also: • Delete non-active jobs • Resend a job that has failed or is in hold • Send a job that has failed or is in hold, to a new destination. The jobs status displayed in the DICOM spooler window can be: • Pending: the job is complete, waiting to be active. • In hold: the job is incomplete, waiting for more images. • Append: the job is connected to the destination device but is waiting for more images (Direct store function). • Active: the job is complete and connected to the destination device. • Failed: the job is complete but one or more images failed to transmit to the destination device. • Done: the job is saved to the destination device. The jobs that are done are removed from the spooler after a while. Star ting the DICOM spooler Alternative: Press F4. 1. On the alphanumeric keyboard, press and hold down the ALT key and press S. The DICOM spooler window is displayed (see Figure 8- 34). The DICOM spooler window is automatically updated every minute. Press Refresh to update the information displayed at any time.
Archiving 326Vivid7/Vivid7 PRO Users Manual FC092326-03 Figure 8-34: The DICOM job spooler window Deleting a job Only non-active jobs can be deleted.1. Trackball to the job to delete in the DICOM job spooler window. 2. Press SELECT. 3. Trackball to Delete. 4. Press SELECT. Resending a job Only jobs that failed or are in hold can be resent.1. Trackball to the job to re-send in the DICOM job spooler window. 2. Press SELECT. 3. Trackball to Resend. 4. Press SELECT.