    							Peripherals
    Vivid7/Vivid7 PRO Users Manual387
    FC092326-03
    7. Press SELECT.
    The VCR spools the tape and stops at the given counter 
    value.
    Additional playback features
    When playing back an examination, part of it can be stored on 
    the computer’s memory as a cineloop. The cineloop enables 
    the user to perform further operations on the stored section 
    (see page 62 for further information on cineloop operation).
    To store a recorded sequence as a cineloop
    1. Press 
    FREEZE while playing back a recorded session.
    The last few seconds are stored as a cineloop.
    Refer to ’Cineloop operation’ on page 62 for further details on 
    working with cineloops. 
    						
    							Peripherals
    388Vivid7/Vivid7 PRO Users Manual
    FC092326-03
    Printing
    The Vivid 7/Vivid 7 PRO ultrasound unit can support a color 
    and a black & white thermal video printer. The printer devices 
    are controlled from the 
    PRINT keys on the control panel (see 
    Figure 11-5).
    The 
    PRINT keys can also be configured to perform alternative 
    storage (i.e. storage to DICOM media or secondary capture). 
    See page 432 for configuration of the 
    PRINT keys.
     Figure 11-5: The printer The printer controls on the Control panel
    To print an image
    For details on the 
    Thermal video 
    printers operation, 
    consult the manu-
    facturer operator 
    manual provided 
    with the printer.1. Press PRINT or ALT. on the Control panel (see Figure 11-5).
    The image displayed on the screen is printed on B&W or 
    Color printer, depending on the key assignment 
    configuration (see page 432).
    1. Alt. Print
    2. Print 
    						
    							Peripherals
    Vivid7/Vivid7 PRO Users Manual389
    FC092326-03
    Specifications for peripherals
    Please refer to the documentation accompanying the 
    peripherals. 
    						
    							Peripherals
    390Vivid7/Vivid7 PRO Users Manual
    FC092326-03 
    						
    							Presets and System setup
    Vivid7/Vivid7 PRO Users Manual391
    FC092326-03
    Chapter 12 
    Presets and System setup
    This chapter includes the following information:
    • Introduction  ................................................................................... ..  392
    • Starting the Configuration package  ............................................ ..  395
    • To open the Configuration package  ......................................... 395
    • Overview  ........................................................................................ ..  396
    • Imaging  .......................................................................................... ..  397
    • The Global setup sheet  ............................................................ 397
    • Application ................................................................................ 400
    • Application menu ...................................................................... 404
    • Measure  ......................................................................................... ..  406
    • Configuration of the Measurement menu  ................................. 409
    • Report  ............................................................................................ ..  414
    • The Report templates sheet  ..................................................... 415
    • The diagnostic codes sheet  ..................................................... 418
    • The Comment texts sheet  ........................................................ 420
    • Connectivity  .................................................................................. ..  423
    • Dataflow  ................................................................................... 424
    • Additional outputs ..................................................................... 432
    • Formats  .................................................................................... 437
    • TCP/IP ...................................................................................... 442
    • System  ........................................................................................... ..  443
    • The system settings  ................................................................. 443
    • About .............................................................................................. ..  447
    • Administration ............................................................................... ..  448
    • Users  ........................................................................................ 449
    • Logon  ....................................................................................... 452 
    						
    							Presets and System setup
    392Vivid7/Vivid7 PRO Users Manual
    FC092326-03
    Introduction
    This chapter describes the configuration management package 
    of the Vivid 7/Vivid 7 PRO ultrasound unit. The Vivid 7/
    Vivid 7 PRO configuration package enables users to customize 
    the global configuration for the unit and the application-specific 
    settings.
    In addition, users with administration rights have access to the 
    local archive backup function, local archive restore function and 
    creation of users.
    The configuration management package consists of a Setup 
    dialogue window divided in different setup categories with 
    sublevels.
    The table below summarizes the contents and access rights of 
    the different categories and sublevels of the Vivid 7/
    Vivid 7 PRO configuration package:
    Category and sublevel Description access Refer to
    Imagingpage 397
    •  Global Sets the cineloop controls and 
    display.
    Sets the patient information 
    display.
    Sets the scan information 
    displayed on the video record.All
    •  Application Configures the probe and 
    application specific settings. All
    •  Application menu Configures the Application 
    menu.All
    MeasureConfigures the Measurement 
    menu by selecting and defining 
    the sequence of the 
    measurements and calculation 
    to perform. The selected 
    measurements and calculation 
    are displayed in the worksheet.All page 406
    Reportpage 414 
    						
    							Presets and System setup
    Vivid7/Vivid7 PRO Users Manual393
    FC092326-03
    • Templates • Configures the Report 
    templates menu by selecting 
    and ordering the templates to 
    show in the menu.All
    •  Diagnostic  codes Create or delete pre-defined text 
    input for the referral reasons and 
    diagnosis.All
    •  Comment  texts Create or delete pre-defined text 
    input for the comments.All
    Connectivitypage 423
    •  Dataflow Create new dataflows or 
    configure existing dataflows.Admin
    •  Additional outputs Configure the 
    PRINT and ALT 
    keys.Admin
    •  Tools Formats and verifies removable 
    media.All
    • Formats Configures the Examination list 
    window display and other 
    options related to the patient 
    management.All
    •  TCPIP Sets the Transmission Protocol/
    Internet Protocol.Admin
    Systempage 443
    •  Settings Sets the date and time format, 
    language and units.Admin
    •  Test Enables testing of the different 
    parts of the unit.Admin
    AboutDisplays information about the 
    software, hardware and probes.All page 447
    Administrationpage 448
    •  Backup Local archive and system 
    configuration backup.Admin Category and sublevel Description access Refer to 
    						
    							Presets and System setup
    394Vivid7/Vivid7 PRO Users Manual
    FC092326-03
    •  Restore Restore local archive and 
    system configuration from a 
    backup.Admin
    •  Users Operator and referring staff 
    registration, operators rights 
    settings.Admin
    ServiceThis sheet is for service staff 
    only. Deals with video selection, 
    LCD light setting, printer 
    definition and keyboard 
    configuration.Admin Category and sublevel Description access Refer to 
    						
    							Presets and System setup
    Vivid7/Vivid7 PRO Users Manual395
    FC092326-03
    Star ting the Configuration package
    To access the Configuration package the user has to log on as 
    a specific user (see page 449). This ensures user-specific and 
    user-defined settings and presets to be used.
    The access to the entire configuration package is user 
    configuration dependent (see page 449).
    To open the Configuration package
    1. Press CONFIG on the alphanumeric keyboard.
    The Log In window is displayed asking for operator ID and 
    password (see Figure 12-1).
    2. Select Log on when completed.
    The Setup dialogue window is displayed (see Figure 12-2).
     Figure 12-1: The Operator login window
    1. Select the operator
    2. Type password 
    						
    							Presets and System setup
    396Vivid7/Vivid7 PRO Users Manual
    FC092326-03
    Over view
    The configuration management package consists of a Setup 
    dialogue window divided in different setup categories with 
    sublevels (sheets labelled with tab).
    The functionality of each configuration category and associated 
    sublevels are described on the following pages.
     Figure 12-2: The Setup dialogue window structure
    1. Sublevel tabs for the 
    selected Setup 
    category.
    2. Setup categories
    3. Selected Setup 
    category 
    						
    All GE manuals Comments (0)

    Related Manuals for GE Vivid 7 User Manual