Home > GE > Ultrasound System > GE Vivid 7 User Manual

GE Vivid 7 User Manual

    Download as PDF Print this page Share this page

    Have a look at the manual GE Vivid 7 User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 45 GE manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    Page
    of 536
    							Getting started
    Vivid7/Vivid7 PRO Users Manual17
    FC092326-03
    S Video OutNTSC/PAL S-
    VideoVCR or video 
    monitorSignal level 1Vp-p
    SVGA OutRGB high 
    resolution videoComputer monitor
    USBUniversal serial 
    busPrinter
    Ethernet10/100 Base-TX 
    Ethernet IEEE 
    8023Network device Socket Signal type Device type Note 
    						
    							Getting started
    18Vivid7/Vivid7 PRO Users Manual
    FC092326-03
    Switching On/Off
    To switch on the unit:
    1. Switch on the circuit breaker on the rear of the unit (see 
    Figure 1-4).
    2. Press   (on/off button) on the top left of the control panel 
    (see Figure 1-4).
    After initialization the default scanning screen (2D mode) is 
    displayed, the active probe being the one connected to the 
    left most connector socket.
    Switching off the unit
    When the Vivid 7/Vivid 7 PRO is switched off, the system 
    performs an automatic shutdown sequence. The unit can be 
    switched off into two states.
    • Standby mode: most of the system is powered down, but 
    a certain portion of the unit remains energized. The standby 
    mode allows a shorter reboot time when the system is used 
    on a daily basis or moved from one place to another.
    • Full shutdown: the entire system is shut down. It is 
    recommended to perform a full shutdown at least once a 
    week.
    Full shutdown
    After switching off 
    the system, wait at 
    least ten seconds be-
    fore turning it on 
    again.1. Press   (on/off button) on the top left of the control panel.
    The Exit dialogue window is displayed.
     Figure 1-3: The Exit dialogue window 
    						
    							Getting started
    Vivid7/Vivid7 PRO Users Manual19
    FC092326-03
    In case of total lock-
    up of the system, 
    hold the on/off but-
    ton down a few sec-
    onds to turn the 
    system off.2. Select Shutdown.
    The shutdown process takes a few seconds and is 
    completed when the control panel illumination is turned off. 
    To switch off before moving the unit, follow the additional steps 
    below:
    1. Set the circuit breaker to OFF.
    2. Remove the plug from the mains power socket.
    3. Secure the unit power cable around the cable storage 
    hooks on the rear of the unit.
     Figure 1-4: The Circuit breaker and On/Off button
    Standby mode
    1. Press   (on/off button) on the top left of the control panel.
    The Exit dialogue window is displayed (Figure 1-3).
    2. Select Standby.
    The system enters in standby mode.
    If the unit is to be moved while in standby, follow the additional 
    steps below:
    1. Set the circuit breaker to OFF.
    2. Remove the plug from the mains power socket.
    F 1F1 
    						
    							Getting started
    20Vivid7/Vivid7 PRO Users Manual
    FC092326-03
    At the new location:
    1. Secure the power plug in the wall outlet.
    2. Switch on the circuit breaker on the rear of the unit 
    (Figure 1-4).
    3. Press   (on/off button) (Figure 1-4).
    When turning on a system in standby it takes a few seconds 
    before it responds. Do not push the on/off button again during 
    this period (A second push will initiate a full shutdown).
    If the power cable is removed from the wall outlet the system 
    will remain in Standby mode for approximately 15 min using an 
    internal battery. If the system is unplugged for a longer time 
    period a full shutdown is automatically performed.
    The system can be used regardless of the battery level. The 
    battery is automatically charged when the system is plugged to 
    the wall outlet and the circuit breaker is switched on. It takes 
    about 10 hours to charge a flat battery.
    If the system is left in the OFF condition (Circuit breaker in the 
    OFF position and system unplugged from the wall out let) for 
    an extended period of time (3 to 5 days or more), the system 
    may not boot up or may beep when turned ON. Should this 
    occur, the system needs to recharge the UPS batteries. This 
    could take 15 minutes to as long as 10 hours, depending on the 
    battery age, system input voltage and system temperature.
    To eliminate draining the UPS batteries, the system should 
    remain plugged into the wall outlet with the circuit breaker in 
    the ON position. 
    						
    							Getting started
    Vivid7/Vivid7 PRO Users Manual21
    FC092326-03
    Moving and transporting the unit
    Wheels
    The wheels of the unit are controlled by the pedals situated 
    between the front wheels of the unit (see Figure 1-5). 
    Examine the wheels frequently for defects to avoid breaking or 
    jamming.
     Figure 1-5: The Vivid 7/Vivid 7 PRO ultrasound unit pedalsWheel Characteristics
    Front Swivel, swivel lock and full lock
    Rear Swivel, but do not lock
    1. Swivel lock pedal 
    (Free position)
    2. Full lock pedal 
    (Free position)
    3. Front wheel
    12
    3 
    						
    							Getting started
    22Vivid7/Vivid7 PRO Users Manual
    FC092326-03
    Wheel operation
    To engage the pedal in full lock
    To release the brake
    To engage swivel lock
    Pedal Action
    Press on pedal no. 2
    Pedal Action
    Press on pedal no.1
    Pedal Action
    Press on pedal no.1
    12
    12 
    						
    							Getting started
    Vivid7/Vivid7 PRO Users Manual23
    FC092326-03
    To release swivel lock
    Moving the unit
    To prepare the unit to be moved
    1. If not locked, push the keyboard console to its park position.
    2. Turn the system off, including the circuit breaker (see 
    page 18), and remove the plug from the wall.
    3. Disconnect all cables linking the unit to any off-board 
    peripheral devices and network.
    Note the marks on 
    each cable to recon-
    nect them later.4. Secure the unit’s power cable.
    5. Place all probes in the probe holder. Ensure that the probe 
    cables do not protrude from the unit or interfere with the 
    wheels.
    The park port may 
    also be used for a 
    probe connection al-
    though it is not ac-
    tive.6. Ensure that no loose items are left on the unit
    7. Unlock the brake (see page 22).
    To ensure safety while moving the unit
    1. Ensure that the keyboard console is in locked position.
    2. Proceed cautiously when crossing door or elevator 
    thresholds. Grasp the front handle grips or the back handle 
    Pedal Action
    Press on pedal no. 2
    WARNINGDo not move the unit if the keyboard console is in free position.
    Ensure that the hands of the patient are away from the console 
    arm when moving the keyboard console. 
    						
    							Getting started
    24Vivid7/Vivid7 PRO Users Manual
    FC092326-03
    bar and push or pull. Do not attempt to move the unit using 
    cables or probe connectors. Take extra care while moving 
    the unit on inclines.
    3. Ensure that the unit does not strike the walls or door 
    frames.
    4. Ensure the pathway is clear.
    5. Move the unit slowly and carefully.
    6. Use two or more persons to move the unit over long 
    distances or on inclines.
    Transpor ting the unit
    Take extra care when transporting the unit by vehicle. In 
    addition to the moving precautions listed on page 23, follow the 
    procedure described below.
    1. If not locked, push the keyboard console to its park position.
    2. Disconnect all probes and secure them in their boxes.
    3. Ensure that the transporting vehicle is appropriate for the 
    unit’s weight. The recommended load capacity is a 
    minimum of 190 kg (419 lbs).
    4. Park the vehicle on a level surface for loading and 
    unloading.
    5. Secure the unit while it is on the lift, to prevent rolling. Do 
    not attempt to hold it in place by hand. Cushion the unit and 
    strap the lower part so that it does not break loose.
    6. Ensure that the unit is secured inside the vehicle. Secure it 
    with straps to prevent movement while in transit.
    7. Drive cautiously to prevent vibration damage.
    Reinstalling at a new location
    1. When the unit is in place at a new location, lock the wheel 
    CAUTIONAvoid ramps that are steeper than 10 degrees.
    WARNINGDo not move/lift the unit if the keyboard console is in free 
    position. 
    						
    							Getting started
    Vivid7/Vivid7 PRO Users Manual25
    FC092326-03
    brakes (see page 22).
    2. Follow the installation procedure described on page 12.
    Unit acclimation time
    Following transport the unit may be very cold or hot. Allow the 
    unit to acclimate before being switched on. Acclimation will 
    take one hour for each 2.5 ºC increment when the unit’s 
    temperature is below 10 ºC or above 40 ºC.
    ºC02.557.510354042.5
    ºF32 36.5 41 45.5 50 95 104 108.5
    Hours43210023
    ºC45 47.5 50 52.5 55 57.5 60
    ºF113 117.5 122 126.5 131 135.5 140
    Hours45678910 
    						
    							Getting started
    26Vivid7/Vivid7 PRO Users Manual
    FC092326-03
    System description
    System over view
     Figure 1-6: the Vivid 7/Vivid 7 PRO ultrasound system
    1
    2
    3
    4
    5
    6
    78
    9
    10
    11
    12
    13 
    						
    All GE manuals Comments (0)