Card Installation 1. To protect the printed circuit board from static 0 Insert the optional card with holding a levers of electricity, first discharge any body static by the card into the KX-T123211 surely. touching the metal board. Do not touch parts on the card. 2. Loosen the screws to remove the metal board. 3. The location of the optional cards for the KX-Tl23211 is shown in the following. (KX-T123292) $1 l!h _ --__ I \ \ I I // / (KX-T123241) metal board v Screws - 0 3 P 2 - 25

OPTION (cont.) To add eight extensions (jack number 17 through 24), use the optional expansion card KX-T123270. To add four extensions (jack number 17 through 20), use the optional expansion card KX-T123271. 1. Insert the expansion card KX-Tl23270 or KX-Tl23271 into the KX-Tl23211 2. Insert connector to the KX-T123270 or KX-T123271 as shown at right. Cable Pin Numbers to be connected See page 2-10. 0 Mis-connection may cause the KX-T123211 to operate improperly. See “During Installation” page 6-l and “During Connection” page 6-2 before connecting. To Extensions (jack number 17 through 20, or 17 through 24 ) w= Expansion/card KX-T123270 . . jack number 17 through 24 KX-T123271 . . . jack number 17 through 20 To add eight extensions (jack number 25 through 32), use the optional expansion card KX-T123270. To add four extensions (jack number 25 through 28), use the optional expansion card KX-T123271. 1. Insert the expansion card KX-T123270 or KX-T123271 into the KX-T123211. 2. Insert connectorto the KX-T123270 or KX-T123271 as shown at right. Cable Pin Numbers to be connected 0 See page 2-10. Mis-connection may cause the KX-T123211 to operate improperly. See “During Installation” page 6-1 and “During Connection” page 6-2 before connecting. To Extensions (jack number 25 through 28, or 25 through 32 ) Expansion card KX-T123270 . . . jack number 25 through 32 KX-T123271 . . . jack number 25 through 28 2-26

To add four Central Office Lines (CO 9 through 12), use the optional expansion card KX-Tl23280. 1. 2. . 0 Insert the expansion card KX-T123280 into the KX-Tl23211. R : Ring T :Tip Vi ack (CO) Insert the modular plug of the telephone line cord (2-conductor wiring) into the modular jack on the KX-T123280. Mis-connection may cause the KX-T123211 to operate improperly. See “During Installation” page 6-l and “During Connection” page 6-2 before connecting. To Terminal Board or Modular Jacks + )rn the Central Office (CO). Use 2-conductor wiring cord To add two Central Office lines (CO9 and COlO), use the optional expansion card KX-Tl23281. 1. 2. 0 Insert the expansion card KX-T123281 into the KX-T123211. Insert the modular plug of the telephone line cord (2-conductor wiring) into the modular jack on the KX-T123281. Mis-connection may cause the KX-Tl23211 to operate improperly. See “During Installation” page 6-l and “During Connection” page 6-2 before connecting. To Terminal Board or Modular Jacks from the Central Office (CO). R :Ring T : Tip View of TEL Jack (CO) b co9 co10 \ - 0 s P Use 2-conductor wiring cord 2-27

OPTION (cont.) When you remove the card, pull upward. To add four Central Office lines (CO5 through 8), use the optional expansion card KX-T123280. Insert the expansion card KX-T123280 into the KX-T123211. Insert the modular plug of the telephone line cord (2-conductor wiring) into the modular jack on the KX-T123280. Mis-connection may cause the KX-T123211 to operate improperly. See “During Installation” page 6-l and “During Connection” page 6-2 before connecting. R : Ring T : Tip View of TEL Jack (CO) co5 CO6 co7 CO8 To Terminal Board or Modular Jacks @ from the Central Office (CO). Use 2-conductor wiring cord 2-28

To connect the optional DSS Console (KX-T123240 or KX-T61640), the optional DSS Console card (KX-T123241) is required. The DSS Console (KX-T123240 or KX-T61640) needs a paired Telephone (EMSS Proprietary Telephone) for proper operation, because the DSS console cannot work by itself. The EMSS Proprietary Telephone (such as KX-T123220, KX-T123230, KX-T123235, KX-T123250) is required as the paired telephone for dialing, storing, etc. Place the KX-T123240 or KX-T61640 and the paired telephone side by side on your desk. 1. Insert the DSS Console card (KX-Tl23241) into the KX-Tl23211 2. Insert the modular plug of the console line cord (4-conductor wiring) into the modular jack on the KX-T123241. “DSS” is written on the Card. Notes: Dl : Data 1 D2 : Data 2 View of TEL Jack k Console 1 Console 2 Up to 2 KX-T123240’s or KX-T61640’s can be connected to the KX-T123211. Each console requires its own paired telephone. KX-Tl23240 or KX-T61640 can not be connected in pair with a standard telephone. The max. length of the console line cord (twisted cable) that connects the KX-T123211 with the DSS Console is shown below. DSS Console Ca{d KX-T123241 - 0 s P - 4conductor wiring is h tp 6”,q;i;:;f;l;he =7----l Pair Telephone (EMSS Proprietary Telephone) . Pair DSS Console KX-T123240 KX-T61640 26 AWG: Under 460 feet 24 AWG: Under 750 feet 22 AWG: Under 1180 feet When using the KX-T123240 or KX-T61640, program must be done. Refer to “Paired Telephone Assignment for DSS Console” page 3-10. 2-29

OPTION (cont.) Enables a standard telephone installed outside the premise to work as an extension through public orprivate lines. To avail of this feature, an optional Off Premise Extension Unit KX-T123286 is necessary aside from KX-T123285. 1. Insert the Off Premise Extension Card KX-T123285 into the KX-T123211. 2. Insert the connector from the KX-T123286 to the Off Premise Extension Card. Extension Card Connector (24 pin) 3. n 4. Connect the frame of the KX-T123286 to earth ground properly to protect the unit. 5. Plug in the AC Power cord from the KX-T123286. 6. Turn on the Power Switch on the KX-T123286. l The Power indicator will be lit. Insert the modular plug of the Standard Telephone Line (2conductor wiring) into the modular jack on the KX-T123286. Power Switch “OPX” is written on the Card. Off Premise Extension Unit + KX-T123286 Standard Telephone Jack number 32 c To earth ground Jack number 31 Use 2-conductor wiring cord L I Programing must be done to use this feature. W Refer to “Off Premise Extension” on page 3-45. . Primary Power Fuse, (800 mA, 250 V) xl: If the Power Indicator light goes off, the Primary Power Fuse must be replaced after remove the cause. 2 - 30

This feature enables to access System from outside of System and then call to extension or outside line. For example, you can call the desired extension directly by dialing the extension number following the regular CO number. Optional KX-T123292 card is necessary to program KX-T123211 to send Outgoing Message when called with this feature. 1. Insert the Direct Inward System Access Cards A and B into the KX-T123211. “DISA-A” and “DISA-B” are written on each Card. Direct Inward System Access Cards KX-T 123291 DISA-B Card DISA-A Card An Outgoing Message can be sent from the KX-T123211 when a call is received using the “Direct Inward System Access” feature. 1. Insert the Outgoing Message Card KX-T123292 into the KX-Tl23211. Outg Card “OGM” is written on the Card. For how to record OUtgOing Message, refer to “Outgoing Message” on page 4-67. 2 - 31

OPTION (cont.) By using the data terminal connected to RS-232C on KX-T123211 or remote data terminal connected to KX-Tl23211 through MODEM, diagnosis of KX-Tl23211 system can be done. Remote administration H The following optional cards are necessary. 0 Diagnostic Card KX-T123295 0 Direct Inward System Access Cards KX-T123291 (See page 2-31) 0 MODEM Card KX-T123296 (See page 2-32) Data terminal equipment KX-Tl23211 On-site administration RS232C Cable n The following card is necessary. 0 Diagnostic Card KX-Tl23295 Data terminal equipment 1. Insert the Diagnostic Card KX-T123295 into the KX-T123211. KX-T123211 jgfxp!g “DIAG”is written on the Card. This card is necessary for data communication to execute confirmation or registration of System data or diagnosis of the System using remote data terminal equipment. 1. Insert the MODEM Card KX-T123296 into the KX-T123211. MODEM Card KX-T123296 / “MODEM” is written on the Card. 2 - 32

For installing the doorphone, use the Optional Doorphone Adaptor (Use the KX-T30860D only). Installation of the doorphone Installqtion of the Doorphone Adaptor Loosen the screw to separate the doorphone into 2 halves. How to install the Doorphone Adaptor into the KX-Tl23211. 1. Connect a 4-conductor modular connector to the doorphone adaptor. Install the lower case to the wall with 2 screws. l 2 kinds of screws are included. Please choose according to your wall type. See the followings. doorphone adaptor (KX-T30860D) 4-conductor wiring been fixed to the wall. w-------When you wish to install the doorphone directly to the wall. 2. 3. Connect the wires from the terminal box to the screws located in the upper case. to the terminal box (See page 2-34) 4. Secure both halves together and ,re-install the screw. 3. Install the doorphone adaptor into the adaptor compartment. After drawing a CPU Card, insert the adaptor connector into connector on the CPU Card (circuit board). Adaptor Connector Connector CPU Card 2-33

OPTION (cont.) (4 Connect the doorphone adaptor to the terminal box using a 4-conductor modular connector. (W Connect the wires of doorphone 1 to the red and green screws of the terminal box. (C) Connect the wires of doorphone 2 to the yellow and black screws of the terminal box. :or . Doorp 0 Doorphone Wiring hone 1 (KX-T30865) YELLOW RED Doorphone 2 (KX- BLACK GREEN ,T30865) The max. length of the telephone line cord (twisted cable) that connects the KX-T123211 and the doorphone (KX-T30865) is shown below. 26 AWG: Under 230 feet 24 AWG: Under 370 feet Automobile type batteries which customer supplied is available as a backup power supply of the FX-T123211 to operate all the features in the event of power failure. For connecting automobile type batteries, use the Optional Battery Adaptor KX-A26. 1. Connect the Battery Adaptor KX-A26 to automobile type batteries. 2. Connect the Battery Adaptor KX-A26 to the Battery Backup Connector of the Kx-TI 23211. KX-T123211 0 Consisting of two 12 VDC (24 VDC)