CONNECTION l The Power Switch of the KX-T123211 must be off during wiring. After all the wiring are completed, turn the Power Switch ON. o Mis-Wiring may cause the KX-T123211 to operate improperly. Refer to “During Installation” page 6-l and “During Connection” page e-2. l 50 pin configuration and Color coding (Refer to page 2-10.) l Max. length and kind of wire (Refer to pages 2-8; 2-29, 2-30 and 2-34.) l Insertion of Option Card (Refer to page 2-25.) 0 Connection of printer (Refer to page 2-12.) 0 If an extension does not operate properly (for example : The LCD of the KX-T123235/KXYT123230/KX-T61 631/ KX-T61630/KX-T30830 does not display properly.), disconnect the telephone from the extension line and then connect again, or turn OFF the power switch of the KX-T123211 and then ON again. l This product is equipped with a 3-wire grounding type plug, a plug having a third (grounding) pin. This plug will only fit into a grounding-type power outlet. This is a safety feature. If you are unable to insert the plug into the outlet, contact your electrician to replace your obsolete outlet. Do not defeat the purpose of the grounding-type plug. l In areas of frequent electrical storms and/or power failures, we recommend for additional equipment protection, surge protectors such as TELESPIKE BLOK MODEL TSB (TRIPPE MFG. CO.), SPIKE BLOK MODEL SK6-0 (TRIPPE MFG. CO.), Super MAX’” (PANAMAX) or MPl (ITW LINX). Paging Speaker 1 Paging Speaker 2 AC Surge Protector 0 Avoid using the same AC outlet for office equipment and KX-T123211. Use dedicated AC outlet only. .Batterv Adaotor KX-A26 Automobil type batteries I Radio _ 0 Consisting of two 12VDC (24VDC) I . 2-5
r__________-___-__________, I I I I I I I I I I I I I I I I I I : 2 ; _--_ . r----------- ____---___---, I I I I I I I I I I I I I I I I i KX-Tl23240 KX-T61640 ; i___________________--_i (one pair) c Standard Telephone Data Terminal Phone & t i 0 ‘;I Off Premise Extension Unit Standard Telephone (C.O. Surge Protector) 2 of 32 extensions Initial 12 CO Lines toC06 1 r ----~-~~~---~~---__--~~~ 7 I toco7 - 1 I I toC08 i I I I I toco9 I I to co 10 addition I I I I taco 11 I I to co 12 _ I I I I L_______________________-_i 32Extension Lines 16 Extension Lines=lnitial ~---~~~--~--~~----~~~--, 116 Extension Lines.addition l L_-____________________~ 1 (two pair) KX-T30830 :two pair) KX-T30820 (two pair) KX-T30850 :twq pair) KX-T30825 KX-T61631 (two pair) KX-T61630 (two pair) KX-T61620 (two oair) KX-T61650 extension connected to jack number 1 KX-Tl23230 or KX-Tl23235 0 Extension connected jack number 1 must always be a KX-Tl23230 or KX-T123235. KX-T123235 KX-Tl23220 KX-T123250 Telephone with Answering Machine I ; l Parallel connections of telephone I I : need Optional Cards or Adaptor L--J is impossible. 0 When the KX-T30830 is connected to the KX-T123211, enter “DSS Number” or “One Touch Dialing Button” to DSS button. See page 4-61. 2-6
l We recommend that telephone CO jack is used RJll. Insert the modular plug of the telephone line cord (2-conductor wiring) into the modular jack on the KX-T123211. R : Ring T : Tip View of TEL Jack (CO) To Terminal Board or Modular Jacks G7 from the Central Office (CO). Use 2-conductor wiring cord l Mis-connection may cause the KX-T123211 to operate improperly. See “During Installation” page 6-1 and “During Connection” page 6-2 before connecting. co co co co , 2-7
To connect jack number 1 through 8 and 9 through 16, insert connector to the KX-T123211 as shown right. Jack no K K Jack no 1 through 8 - 9 through 16 Connector type 50 pin (Amphenol 57JE series or the equivalent) To Extensions (jack number 1 through 8 ) + To Extensions (jack number 9 through 16 ) * Cable Pin Numbers to be connected See page 2-10. l The max. length of the extension line cord (twisted cable) that connects the KX-T123211 and the extension is shown below. 26 AWG: Under 460 feet 24 AWG: Under 750 feet 22 AWG: Under 1180 feet 6 AWG: Under 2290 fe 0 0 24 AWG: Under 3700 feet I I 22 AWG: Under 5900 feet I ,I I . If a telephone or answering machine with an A-Al relay is connected to the KX-Tl23211, set the A-Al relay switch of the telephone or answering machine to OFF. Mis-connection may cause the KX-T123211 to operate improperly. See “During Installation” page 6-1 and “During Connection” page 6-2 before connecting. 2-8
To connect Amphenol 57JE type (screw-attach-type 50-pin connector) to the KX-T123211, follow the procedure below. 1. Loosen the three screws to move the metal bar aside. I Metal bar 317 Screws 2. Pull the Expansion Card (LC#l) 3. The 50-pin connector (JACK) on the Expansion Card has two hook-pins. Remove the upper hook-pin, taking out the screw. /Expansion Card ,50-pin connector 4. To attach the Amphenol 57JE type (PLUG) to the connector, drive the accessory Screw at the upper part, . and fasten the accessory Wire Tie around the lower hook-pin and the Amphenol 57JE type, as shown. 50-pin* connector Hook-.pin Accessary Wire Tie When connecting a connector of the type shown below, unscrew the lower hook-pin, too. Then drive both accessory Screws. I Expansion Card 5d-pin Aonnector 5. Replace the Expansion Card (LC#l). 6. To connect to the other Expansion Card (LC#2), repeat the steps 2 to 5. 7. Replace the bar and tighten the screws. 2-9
0 Connection of a Standard Telephone Connect the only pin number of “T” and “R”. Cable Pin Numbers to be connected l Connection of the KX-T123235 (Proprietary Telephone) T : Tip Dl : Data 1 Pl : 3 Pair Voice R : Ring D2 : Data 2 P2 : 3 Pair Voice 0 Connection of the Proprietary Telephone Connect the only pin number of “T”, “R”, “Dl ” and “ D2”. ONN CABLE CLIP PIN COLOR NO LC-1 LC-2 LC-3 LC-4 26 WHT-BLU 1 T T T T 1 BLU-WHT 2 R R R 27 WHT-ORN 3 JACK DI R JACK ~1 JACK D1 JACK Dj 2 ORN-WHT 4 No.1 D2 No.9 D2 No.17 D2 No.25 D2 28 WHT-GRN 5 Pl PI Pi Pl 3 GRN-WHT 6 P2 P2 P2 P2 29 WHT-BRN 7 T T T T 4 BRN-WHT 8 R R R R 23 GRN-VI0 46 19 VIO-BRN 47 24 BRN-VI0 48 50 VIO-SLT 49 25 SLT-VI0 50 No.8 ;: P2 No.16 ;: No.24 E: ,No.32 E; P2 P2 P2 Station wrnng (Y-Parr twtsteu cablrng): 50 Pi Bridging Clips
If the telephone you are using with the KX-T123211 is polarity sensitive. - 1. Connect all extension wiring to the KX-T123211. 2. Confirm that dialing can be done from all the extensions using a tone telephone. 3. If a dialing can not be done, the polarity between the extension and the KX-T123211 must be reversed. 6. Confirm that dialing can be done on the following extensions using a tone telephone. Extension of jack number l--CO1 Extension of jack number %-CO2 Extension of jack number g--CO5 Extension of jack number lo--CO6 Extension of jack number 17--CO9 Extension of jack number 18--CO10 Central Office Line KX-Tl23211 Extension 4. Set the Power Switch on the KX-T123211 to the OFF position. 7. If dialing can not be done, the polarity between the KX-T123211 and the Central Office Line must be reversed. KX-Tl23211 Reverse here 6. If any extension is changed or replaced, repeat these procedures (from step 1 through step 7). 5. Connect all Central Office (CO) Lines. . 2-11
Serial Printer Make cables so that the printer may be connected to the KX-Tl23211 as shown in the chart. Serial Interface Cables must be shielded and the maximum length is 6.5 feet. ( RS-232C ) Connection Chart : KX-T123211 RS-232C Printer RS-232C When using special accessories such as cable, the user should use those specified in this installation manual to comply with the limits for a Class A computing device pursuant to Subpart J of Part 15 of FCC Rules. I Circuit Signal Pin Pin Signal Circuit Type (EIA) Name No. No. -Name llg FG l-l FG AA BA TXD 2 - 3 RXD BB BB RXD 3 - 2 TXD BA DTR CD The pin configuration of EIA (RS-232C) connector is as follows. Circuit Type EIA 1 CCITT Pin Number Signal Name FG TXD Frame Ground Transmitted Data AA BA 101 103 KX-D491 OD, KX-D4911, KX-D4920, KX-D4985, etc. If you connect this unit to a Panasonic Data Terminal, the Communication Parameter Transmit XON / XOFF on the Data Terminal must be set to the “YES” position. For further details, see the Operating Instructions of the Data Terminal. 2-12 RXD RTS BB 104 CA 105 Received ,Data Request To Send Clear To Send CB 106 Data Set Ready cc 107 l Panasonic data terminal ; CTS DSR AB CF 7 SG 8 DCC Signal Ground Data Carrier Detect’ Data Terminal Ready CD 108.2 20 DTR
EIA (RS-232C) SIGNALS: Frame Ground (FG); Connects to the unit frame and the earth ground conductor of the AC power cord. Transmitted Data (TXD); . . . . . . . . . . . . . . . . ..@Jtpuq Conveys signals from the unit to the printer. A “Mark” condition is held unless data or BREAK signals are being transmitted. Received Data (R)(D);. . . . . . . . . . . . . . . . . . . . . . . . .(input) Conveys signals from the printer. Request To Send (RTS); . . . . . . . . . . . . . . . . . . .((-Jutput) . This lead is held ON whenever DSR is ON. Clear To Send (CTS);..................... **(input) An ON condition of circuit CTS indicates that the printer is ready to receive data from the unit. The unit dose not attempt to transfer data or receive data when circuit CTS is OFF. Data Set Ready(DSR);.......................(input) An On condition of circuit DSR indicates the printer is ready. Circuit DSR ON does not indicate that communication has been established with the printer. Signal Ground (SG); Connects to the DC ground of the unit for all interface signal. Data Terminal Ready (DTR)...............(output) This signal line is turned ON by the unit to indicate that it is ON LINE. Circuit DTR ON does not indicate that communication has been established with the printer. It is switched OFF when the unit is OFF LINE. Data Carrier Detect (DCD)..................(input) The ON condition is an indication to data terminal (DTE) that the carrier signal is being received. i 1. If the Panasonic printer which is used has a (KX-PI 1 D or KX-P17) board and is connected to the KX-T123211 , set the communication parameters below. KX-Pl 1 D KX-P17 KX-T123211 DIP switch Setting DIP switch Seth ng Word length 7 bit (default) SWl-1 ON SWl-4 ON Program to “EVEN” SWl-2 Parity ON SWl-5 OFF (See page 3-32) SWl-3 ON SWl-6 OFF SWl-5 ON SWl-1 Baud Rate 12008 (default) SWl-6 OFF OFF SWl-7 OFF SWl-2 OFF SWl-8 OFF SWl-3 ON Protocol XON / XOFF mode only SW2-8 OFF SWl-8 ON 2. If the Panasonic data terminal is a KX-D4985 or KX-D4920 and is connected to the KX-T123211, the default value of communication parameter is the same a.s that of the KX-T123211. If the KX-D491 OD is connected to the KX-T123211, set the baud rate of the KX-D491 OD to 1200 baud, the other default value is the same as that of the KX-Tl23211. 2-l 3
Speaker l Output impedance: / 6OOfl 0 CL Amplifier Useshielded cable. 0 0 Use an RCA connector. Paging jack 1 Speaker / 0 Paging equipment 1 Amplifier Paging equipment 2 External Music Source Adjust the sound level of the music on hold with the Volume control. Use a two- conductor plug (9/64 inch in diameter) l Input impedance 0 Input Level -1OdBm 1 1. EXT MUSIC Jack 2-14