    							Alarm codes / 511
    P0992638 03Modular ICS 6. 0 Installer Guide
    2. If there are no devices connected to the Station Module, 
    connect one and then press CLEAR
    .
    3. If there are any devices connected to the Station Module, 
    check all the wiring associated with the devices.
    4. Refer to Data Module down on page 575.
    Alarm: 51-X 
    1. Check the wiring from the ICS to the TM.
    2. Refer to Problems with trunk cartridges service on page 
    566.
    Alarm: 52-X-Y
    1. Follow the procedure in Problems with trunk cartridges 
    service on page 566.
    2. If the problem persists, replace Trunk Cartridge Y on 
    DS-30 port X. 
    Refer to the previous table for the definition of X and Y.
    Alarm: 61-X-Y
    1. Check that the proper Trunk Cartridges are inserted in the 
    proper slots of the ICS or Trunk Module.
    2. Enter programming and look under the Trk/Line data 
    heading. 
    Check that the Trunk Cartridge type is correctly 
    configured. 
    Check that the Trunk mode and Answer mode settings do 
    not conflict for every line connected to Trunk Cartridge Y. 
    If Trunk mode is set to unsupervised, Answer mode must 
    be set to manual. 
    						
    							512 / Alarm codes
    Modular ICS 6.0 Installer GuideP0992638 03
    OR
    Install a Trunk Cartridge in slot Y that matches the type of 
    trunk you have configured.
    Alarm: 62-X-Y
    1. Check that the proper Trunk Cartridges are inserted in the 
    proper slots of the Trunk Module.
    2. Enter programming and look under the Trk/Line data 
    heading. 
    Check that the Trunk mode and Answer mode settings do 
    not conflict for every line connected to Trunk Cartridge Y. 
    If Trunk mode is set to unsupervised, Answer mode must 
    be set to manual.
    Alarm: 63-Z
    1. Check that you have the required E&M Trunk Cartridges. 
    There should be a maximum of one for every two 
    auto-answer loop start lines installed in a Trunk Module.
    2. Enter programming and look under the Trk/Line data 
    heading. Check that the Answer mode is correct for all the 
    loop start lines.
    3. Make sure that all of your E&M trunks installed in a Trunk 
    Module are configured as E&M or DTMF, whichever 
    applies, so that the system knows the receivers are there.
    4. If the problem persists, an E&M Trunk Cartridge may be 
    malfunctioning. Replace one E&M Trunk Cartridge at a 
    time until the problem is resolved. 
    						
    							Alarm codes / 513
    P0992638 03Modular ICS 6. 0 Installer Guide
    Alarm 68-Z
    1. Locate the device(s) connected to port(s) not available for 
    that device type.
    2. Power down the system. 
    3. Disconnect the device from the port identified. 
    4. Reconnect it to a valid port.
    Alarm 75
    1. Check the connection to your ISDN service provider.
    Alarm: 76-X 
    1. Check the wiring from the ICS to the DM.
    2. Refer to Problems with trunk cartridges service on page 
    566.
    3. Refer to Data Module down on page 575. 
    						
    							514 / Event messages
    Modular ICS 6.0 Installer GuideP0992638 03
    Event messages
    Event messages appear as items in the System administration 
    log or the System test log of the Maintenance session. Most of 
    these event messages can only be caused by an unusual 
    combination of events, and should rarely occur. 
    Each event is assigned a severity number. An S preceding this 
    number, S4 for example, may appear in the event message. 
    S9 is the most severe. If the log is full, new event messages 
    with a higher severity number replace existing event messages 
    of a lower severity. For this reason, you should check event 
    messages at regular intervals. You can then deal with all 
    messages before they are replaced.
    Event message information that is specific to Companion 
    components is included in the Modular ICS Companion 
    Installer Guide.
    Dealing with event messages
    For every event message that you see:
    1. Record the event on the appropriate Maintenance record.
    2. Refer to Significant event messages.
    3. To see if the event caused the Norstar system to 
    automatically restart, consult the table on Event Message 
    on page 520. 
    						
    							Event messages / 515
    P0992638 03Modular ICS 6. 0 Installer Guide
    Significant event messages 
    The following table lists event messages that are relevant to 
    Maintenance activities. The time that the message is recorded 
    is also provided.
    Displays
    Event messageThe event message is recorded when…
    Evt:210-YYYZ S4Loopback test YYY on Trunk Cartridge Z has 
    started
    Evt:211-YYYZ S4Loopback test YYY on Trunk Cartridge Z has 
    stopped
    Evt:220-3546  S4the Sys admin log has been cleared by the DN 
    (3546 in this case)
    Evt:221-3546  S4the Sys test log has been cleared by the DN (3546 
    in this case)
    Evt:222-3546  S5the DN (3546 in this case) enters the debugging 
    facility that is password protected
    Evt:255   S9administered mode is not supported by the cartridge 
    plugged into the slot
    Evt:260-0302  S8the ICS takes the access line on port 0302 out of 
    service because no current was detected
    Evt:261-0302  S1the access line on port 0302 is returned to service 
    after current was detected (see Evt:260)
    Evt:263-302  S8the ICS takes the E&M line on port 302 out of 
    service because the far end did  not respond to a 
    disconnect signal
    Evt:264-302  S1the E&M line on port 302 is returned to service after 
    the far end finally responded to a disconnect signal 
    (see  Evt:263)
    Evt:265-302  S7the E&M line on port 302 did not receive an 
    expected wink signal or delay dial signal from the far 
    end
    Evt:267    S9a data module has been disconnected
    Evt:268-07   S8Dialing filter 07 has lost data due to a fault in the 
    system memory 
    						
    							516 / Event messages
    Modular ICS 6.0 Installer GuideP0992638 03
    Evt:269-3546 S8the Line/set filter for the DN (3546 in this case) has 
    lost data due to a fault in the system memory
    Evt:299 S1the system powers up after a power failure
    Evt:327 S5short term alarm threshold has been surpassed in 
    the DTI cartridge
    Evt:328  S5short term alarm threshold has been surpassed in 
    the DTI cartridge
    Evt:329  S5short term alarm threshold has been surpassed in 
    the DTI cartridge
    Evt:330  S5short term alarm threshold has been surpassed in 
    the DTI cartridge
    Evt:336  S5long term alarm has been surpassed in the DTI 
    cartridge
    Evt:373  S5the ICS restart diagnostic tool has been activated
    Evt:400  S9Startup programming is performed using
    ²
    Evt:407  S2there are no more codes for Speed Dial numbers
    Evt:408   S2there is no more memory for Speed Dial codes
    Evt:412-3546 S5the Installer password has been changed by the DN 
    (3546 in this case)
    Evt:413-3546 S3the System Coordinator password has been 
    changed by the DN (3546 in this case)
    Evt:414-3546 S5an invalid Installer password has been entered by 
    the DN (3546 in this case)
    Evt:415-3546 S3an invalid customer  password has been entered by 
    the DN (3546 in this case)
    Evt:416-3546 S4programming is performed using
    ²¥¥‚¯öìéí
    Evt:417-3546 S2programming is performed using
    
    Evt:418  S7a DN change is successful
    Evt:419  S2the time setting has been changed
    Evt:421  S8a DN change failed
    Event messageThe event message is recorded when… 
    						
    							Event messages / 517
    P0992638 03Modular ICS 6. 0 Installer Guide
    Evt:422-3546 S6a length change by the DN (3546 in this case) has 
    been requested
    Evt:423-3546 S6an individual DN change has been requested by the 
    DN (3546 in this case)
    Evt:441  S2a timeout occurred while waiting for ANI or DNIS 
    digits to be received
    Evt:442  S5a timeout occurred while waiting for ANI or DNIS 
    digits to be received
    Evt:453  S4Someone entering **CONFIG
    Evt:454  S5Invalid password entered
    Evt:458   S4Call-by-Call NVRAM data is corrupt
    Evt:459   S9DN length has been changed to less than 3 digits
    Evt:680   S9wireless system is disabled
    Evt:681  S9activation or recovery code entered
    Evt:683    S9new base station configuration detected
    Evt:687    S4the data driver has received a bad call reference
    Evt:688      S4the data driver has received a bad data event
    Evt:689  S4the data driver could not allocate a new index
    Evt:690  S4no response to the ICS within 10 seconds of being 
    sent an initialization message
    Evt:691 S4no response to the ICS within 3 seconds
    Evt:692 S4a bad parameter value has been received in a 
    stimulus message from the data device
    Evt:693 S3old data to be discarded has been detected
    Evt:694 S4RADAR flow control has received a bad stimulus 
    message from an off-core application
    Evt:695 S4attached set denied request for a B-channel
    Evt:696 S2corrupt CLID length
    Evt:697 S2an asynchronous data report generated by SDI 
    module
    Event messageThe event message is recorded when… 
    						
    							518 / Event messages
    Modular ICS 6.0 Installer GuideP0992638 03
    Event message 799
    Event message 799 indicates a call processing error has 
    occurred on an ISDN line. The event number is followed by a 
    number representing the line or loop number, and a code for 
    the type of error. 
    Evt:698  S8incorrect software key entered
    EVT799-00040B
       S7a call processing error on the fourth BRI loop; see 
    Event message 799 on page 518.
    Evt:822  S8Alarm code 63 is sent because there are no DTMF 
    receivers for an incoming call
    Evt:882  S9mobility data re-evaluation sequence initiated
    Evt:883   S4an invalid dial pulse signal was received by the DTI
    Evt:992  S6auto attendant error
    EVT799-XXXX YYS7In this example, the error has occurred on line 
    XXX and the error code is YY.
    Error 
    codeMeaning
    01  Internal software error. Cannot acquire the B-channel from 
    the B-channel arbitrator.
    02  Internal software error.  There is no free line available for  the 
    call.
    03  A call that is not on the B-channel has been attempted. 
    These kind of calls are part of EKTS service, which is not 
    supported by this version of the software. Check with your 
    service provider to make sure your package does not 
    include EKTS service.
    04  Internal software error. Failed to instantiate on the chain.
    05  Internal software error. Activation procedure failed.
    Event messageThe event message is recorded when… 
    						
    							Event messages / 519
    P0992638 03Modular ICS 6. 0 Installer Guide
    Displays
    You should rarely see any event messages that are not 
    described in the Significant event messages on page 515. If 
    you do see one of these event messages, the Norstar system has 
    followed its normal recovery from an unusual combination of 
    system events. Although the problem is not a serious one, 
    repeated occurrences of the event number should be reported 
    as soon as possible.
    As a result of some events, the Norstar system automatically 
    restarts itself. The table on the next two pages lists all the event 
    numbers and tells you which of these events are associated 
    with Norstar system restarts. 
    06  Internal software error. Index conversion failed.
    07  Unexpected digits on a Manual answer mode line. 
    Configuration of the ICS and the network connection may 
    not match.
    08  Internal software error. Cannot seize central office (CO) line 
    on a BRI connection.
    09  Cannot get vterm (virtual terminal) from the Vterm Server.
    0A  Central office did not respond to the SPID initialization 
    request.
    0B  Central office has rejected the SPID. Verify your SPID 
    information programmed under Hardware and with your 
    ISDN service provider.
    0C  Internal software error. Already instantiated on the chain.Error 
    codeMeaning 
    						
    							520 / Event messages
    Modular ICS 6.0 Installer GuideP0992638 03
    Most of these events are recorded in the Sys test log. The few 
    exceptions to this are recorded in the Sys admin log, as 
    indicated.
    Event
    MessageSystem 
    RestartEvent 
    MessageSystem 
    Restart
    101-106Ye s400 (Admin log)Ye s
    107No401-403No
    108-112Ye s405-411No
    113No412-419 (Admin log)No
    114-116Ye s421-423 (Admin log)No
    117No424-425No
    118-120Ye s426-430Ye s
    121-123No431No
    124-125Ye s432Ye s
    126-129No433No
    130Ye s441-442No
    131-132No453No
    133-134Ye s454No
    135-136No458-459No
    137Ye s600-602Ye s
    138-150No603-613No
    151Ye s614Ye s
    152No615-629No
    160-164No630Ye s
    170-173No631-646No
    200-211No680No
    220 (Admin log)No681No
    221-222No683No
    223 (Admin log)No689-698No 
    						