    P0992638 03Modular ICS 6. 0 Installer Guide
    Off-core DTI card
    MICS 6.0 provides the opportunity to expand the number of 
    DTI cards in your system by adding a DTI card to the 
    expansion modules in a midi or maxi system. The card must be 
    installed in either module 3 or 4 on a midi system. On the maxi 
    system, the card can only be installed in module 7 or 8. One 
    DTI card requires the entire module resources, so it is installed 
    in the first slot of the module, and the other two slots must be 
    left empty. The off-core DTI is configured in the same way as 
    the other DTIs on your system.
    This card is supported for profiles 1 and 4.
    Equipment note: The DTI card released in conjunction with 
    MICs 6.0 can be used either on or off-core. However, any 
    previous versions of the DTI card can only be used on the core 
    KSU hardware.
    Replacing a Modular 8x24 KSU
    If you are upgrading your old KSU (8X24) and adding digital 
    T1 trunks to your new system (0X32 ICS):
    1. Verify your system programming, and update your 
    Programming Record.
    2. Follow the procedures outlined in Installation on page 209 
    for installing a new system.
    10110000*Korea
    XXXXXXX1*Reserved
    XXXXXX1X*Reserved
    XXXXX1XX*Reserved
    * Reserved for future development
    DIP switch settingCountry profile 
    						
    							202 / Planning the installation
    Modular ICS 6.0 Installer GuideP0992638 03
    If you are upgrading your 8X24 KSU, but not adding digital 
    T1 trunks to a 0X32 system:
    1. Verify your system programming, and update your 
    Programming Record.
    2. Disconnect the 50-pin connector for telephones from the 
    KSU.
    3. Disconnect the 50-pin connector for external lines and 
    auxiliary equipment from the KSU.
    4. Remove power from your system.
    5. If your system includes Trunk Modules and Station 
    Modules with DS-30 copper connectors, disconnect the 
    DS-30 copper connectors from the Expansion Cartridge.
    6. Remove any cables from the KSU cable trough.
    7. Remove the KSU and wall-mount bracket from the wall.
    8. Install the new 0X32 ICS following the procedures in the 
    Installation on page 209. 
    9. If your system includes Trunk Modules and or Station 
    Modules with DS-30 copper connectors, install a 
    compatible Expansion Cartridge with copper connectors in 
    slot 1 of the ICS. The faceplate will cover slots 1 and 2.
    10. If you have installed a copper Expansion Cartridge in the 
    0X32 ICS, clip the ferrite bead that was shipped with the 
    Expansion Cartridge onto the ICS power supply power 
    cord.
    Do not reuse 8X24 Expansion Cartridge
    You cannot reuse an 8X24 Expansion Cartridge in the 
    0X32 ICS. You must install a supported Expansion 
    Cartridge. 
    						
    							Planning the installation / 203
    P0992638 03Modular ICS 6. 0 Installer Guide
    Locating the ferrite bead
    Ferrite bead required to meet EMI requirements
    When using a copper Expansion Cartridge, you must 
    install the ferrite bead on the ICS power cord to ensure 
    that the product continues to meet FCC Part 15 Class A 
    EMI requirements.
    max 5 cm (2 in)
    ferrite bead 
    						
    							204 / Planning the installation
    Modular ICS 6.0 Installer GuideP0992638 03
    11. If your system includes Trunk Modules and or Station 
    Modules with DS-30 copper connectors, reconnect the 
    fiber interface cables to the Expansion Cartridge.
    12. Power up the system.
    13. Reconnect your 50-pin connector for internal telephones to 
    the internal telephone connector on the ICS.
    14. Reconnect your external line and auxiliary equipment 
    wiring according to the procedures and wiring charts in the 
    Installation on page 209. You cannot reuse your original 
    50-pin connector for external lines and auxiliary 
    equipment, because the pin-outs have changed (unless 
    connections are rewired).
    DNs on Station Modules will change
    If you simply reconnect the 50-pin connector for 
    telephones on the ICS, and leave your Station 
    Modules telephone connectors alone, your 
    directory numbers will change. 
    The new 0X32 ICS can accommodate 32 
    telephones. The old 8X24 KSU connected only 
    24 telephones. Port numbering has been 
    changed accordingly.
    To preserve existing directory numbers consult 
    the wiring charts in 
    Connecting the wiring on 
    page 237 and change the DNs using 
    Change DNs 
    in
     System prgrming. 
    						
    							Planning the installation / 205
    P0992638 03Modular ICS 6. 0 Installer Guide
    Trunk module line numbering
    In MICS 6.0/MICS-XC 6.0 software, the line numbering for 
    all profiles has been adjusted to accommodate the Profile 2 
    ETSI requirement of 30 lines. This could affect applications 
    such as Norstar Voice Mail or CallPilot 150. The chart below 
    shows the line numbering transitions between the various 
    versions of software. Note also that target lines have been 
    renumbered.
    Note:  MICS 6.0 line numbering varies, depending on the 
    profile you choose for your system, and which type of 
    trunk module you are using, or what protocol you 
    choose for the module (DTI). Refer to TrunkMod on 
    page 467. 
    Line numbering for upgrades 
    ModuleCartridgeMICS 1.0 
    and
    1.1 linesMICS 2.0, 
    3.0, 4.0, and 
    5.0 linesMICS 6.0 
    lines
    Mod 08
    Cd1-Mod849-5249-5661-68
    Cd2-Mod853-5657-6469-76
    Cd3-Mod857-6065-7277-84
    Mod 07
    Cd1-Mod761-6473-8085-92
    Cd2-Mod765-6881-8893-100
    Cd3-Mod769-7289-96101-108
    Mod 06
    Cd1-Mod673-7697-100109-112
    Cd2-Mod677-80101-104113-116
    Cd3-Mod681-84105-108117-120
    Mod 05
    Cd1-Mod585-88109-112121-124
    Cd2-Mod589-92113-116125-128
    Cd3-Mod593-96117-120129-132 
    						
    							206 / Planning the installation
    Modular ICS 6.0 Installer GuideP0992638 03
    Upgrading ILG functionality with hunt groups 
    In MICS 4.0, Hunt groups replaced ILG functions from 
    previous versions of MICS. The hunt group broadcast mode 
    contains the equivalent of ILG functionality. 
    Hunt groups allow the following call programming:
    calls can be queued when all the members in a hunt group 
    are busy
    call forwards are overridden by the hunt group routing, 
    allowing calls to be distributed to other members in the 
    hunt group in a way that does not depend on the busy 
    situation of its members
    the ring / call distribution pattern can be programmed to 
    determine who receives what call and in what order
    an overflow position can be programmed to another hunt 
    group
    sequential and rotary modes are also available to provide 
    versatility to hunt group configurations
    Mod 04
    Cd1-Mod497-100121-124133-136
    Cd2-Mod4101-104125-128137-140
    Cd3-Mod4105-108129-132141-144
    Mod 03
    Cd1-Mod3109-112133-136145-148
    Cd2-Mod3113-116137-140149-152
    Cd3-Mod3117-120141-144153-156
    Target lines145-272
    145-336 
    (expanded)157-284
    157-348 
    (expanded)
    ModuleCartridgeMICS 1.0 
    and
    1.1 linesMICS 2.0, 
    3.0, 4.0, and 
    5.0 linesMICS 6.0 
    lines 
    						
    							Planning the installation / 207
    P0 99 26 38 03   Modula r IC S 6 .0  In sta ll e r G uid e
    For more information on hunt groups, see  System prgrming on 
    page 389.
    Planning Hospitality functions MICS 4.1 introduced the Hospitality feature, which allows 
    businesses such as hotels to monitor and set room conditions 
    and status, and to program alarms from both an administrative 
    telephone and indivi dual room telephones.
    Hospitality features allow the following programming:
     Administrative telephone (password access) – monitor and set room condition
    – monitor and set room occupancy
    – monitor and set or cancel alarms
     Room telephone – Allow staff to set room condition (password access)
    – Allow guests to set or cancel wakeup alarms 
    						
    							208 / Planning the installation
    Modular ICS 6.0 Installer GuideP0992638 03 
    						
    							P0992638 03Modular ICS 6. 0 Installer Guide
    Installation
    Only qualified persons should service the system.
    The installation and service of this unit is to be 
    performed only by service personnel having appropriate 
    training and experience. It is critical that installers have 
    the necessary awareness about hazards to which they 
    are exposed in performing a task, and of the measures 
    required to minimize the danger to themselves or other 
    persons.
    Electrical shock hazards from the telecommunication 
    network and AC mains are possible with this equipment. 
    To minimize risk to service personnel and users, the 
    ICS must be connected to an outlet with a third-wire 
    ground. In addition, all unused slots should have filler 
    faceplates installed and the doors should be in place at 
    the completion of any servicing.
    Service personnel must be alert to the possibility of high 
    leakage currents becoming available on metal system 
    surfaces during power line fault events near network 
    lines. A risk point on the ICS is the power cord earth 
    ground pin. These leakage currents normally safely flow 
    to Protective Earth ground via the power cord. 
    Therefore, it is mandatory that connection to a grounded 
    outlet is performed first and removed last when cabling 
    to the unit. Specifically, operations requiring the unit to 
    be powered down must have the network connections 
    (central office lines) removed first. 
    						
    							210 / Installation
    Modular ICS 6.0 Installer GuideP0992638 03
    Installation checklist
    åtest all ISDN network connections, if any
    åmount the Integrated Communications System (ICS) 
    åmount the expansion modules (as required)
    åinstall the Modular ICS NVRAM cartridge
    åinstall the Expansion Cartridge, Trunk Cartridges 
    (DTI, PRI, or BRI cards, as required)
    åinstall the optional equipment
    åinstall power bars, as required
    åmount the distribution panel
    åcomplete the wiring
    åinstall the fiber cables
    åinstall the emergency telephone(s)
    åinstall the Norstar telephones
    åpower up the system
    åconnect the cables between the distribution block and the 
    expansion modules
    åinstall the door
    åselect the default template using System Startup 
    programming
    åprogram to customer requirements
    årecord programming details in the Programming Record
    åensure that all telephone keys are properly labelled
    åensure that all telephones are working
    åcheck that the system is working properly 
    						