Planning the installation / 201 P0992638 03Modular ICS 6. 0 Installer Guide Off-core DTI card MICS 6.0 provides the opportunity to expand the number of DTI cards in your system by adding a DTI card to the expansion modules in a midi or maxi system. The card must be installed in either module 3 or 4 on a midi system. On the maxi system, the card can only be installed in module 7 or 8. One DTI card requires the entire module resources, so it is installed in the first slot of the module, and the other two slots must be left empty. The off-core DTI is configured in the same way as the other DTIs on your system. This card is supported for profiles 1 and 4. Equipment note: The DTI card released in conjunction with MICs 6.0 can be used either on or off-core. However, any previous versions of the DTI card can only be used on the core KSU hardware. Replacing a Modular 8x24 KSU If you are upgrading your old KSU (8X24) and adding digital T1 trunks to your new system (0X32 ICS): 1. Verify your system programming, and update your Programming Record. 2. Follow the procedures outlined in Installation on page 209 for installing a new system. 10110000*Korea XXXXXXX1*Reserved XXXXXX1X*Reserved XXXXX1XX*Reserved * Reserved for future development DIP switch settingCountry profile
202 / Planning the installation Modular ICS 6.0 Installer GuideP0992638 03 If you are upgrading your 8X24 KSU, but not adding digital T1 trunks to a 0X32 system: 1. Verify your system programming, and update your Programming Record. 2. Disconnect the 50-pin connector for telephones from the KSU. 3. Disconnect the 50-pin connector for external lines and auxiliary equipment from the KSU. 4. Remove power from your system. 5. If your system includes Trunk Modules and Station Modules with DS-30 copper connectors, disconnect the DS-30 copper connectors from the Expansion Cartridge. 6. Remove any cables from the KSU cable trough. 7. Remove the KSU and wall-mount bracket from the wall. 8. Install the new 0X32 ICS following the procedures in the Installation on page 209. 9. If your system includes Trunk Modules and or Station Modules with DS-30 copper connectors, install a compatible Expansion Cartridge with copper connectors in slot 1 of the ICS. The faceplate will cover slots 1 and 2. 10. If you have installed a copper Expansion Cartridge in the 0X32 ICS, clip the ferrite bead that was shipped with the Expansion Cartridge onto the ICS power supply power cord. Do not reuse 8X24 Expansion Cartridge You cannot reuse an 8X24 Expansion Cartridge in the 0X32 ICS. You must install a supported Expansion Cartridge.
Planning the installation / 203 P0992638 03Modular ICS 6. 0 Installer Guide Locating the ferrite bead Ferrite bead required to meet EMI requirements When using a copper Expansion Cartridge, you must install the ferrite bead on the ICS power cord to ensure that the product continues to meet FCC Part 15 Class A EMI requirements. max 5 cm (2 in) ferrite bead
204 / Planning the installation Modular ICS 6.0 Installer GuideP0992638 03 11. If your system includes Trunk Modules and or Station Modules with DS-30 copper connectors, reconnect the fiber interface cables to the Expansion Cartridge. 12. Power up the system. 13. Reconnect your 50-pin connector for internal telephones to the internal telephone connector on the ICS. 14. Reconnect your external line and auxiliary equipment wiring according to the procedures and wiring charts in the Installation on page 209. You cannot reuse your original 50-pin connector for external lines and auxiliary equipment, because the pin-outs have changed (unless connections are rewired). DNs on Station Modules will change If you simply reconnect the 50-pin connector for telephones on the ICS, and leave your Station Modules telephone connectors alone, your directory numbers will change. The new 0X32 ICS can accommodate 32 telephones. The old 8X24 KSU connected only 24 telephones. Port numbering has been changed accordingly. To preserve existing directory numbers consult the wiring charts in Connecting the wiring on page 237 and change the DNs using Change DNs in System prgrming.
Planning the installation / 205 P0992638 03Modular ICS 6. 0 Installer Guide Trunk module line numbering In MICS 6.0/MICS-XC 6.0 software, the line numbering for all profiles has been adjusted to accommodate the Profile 2 ETSI requirement of 30 lines. This could affect applications such as Norstar Voice Mail or CallPilot 150. The chart below shows the line numbering transitions between the various versions of software. Note also that target lines have been renumbered. Note: MICS 6.0 line numbering varies, depending on the profile you choose for your system, and which type of trunk module you are using, or what protocol you choose for the module (DTI). Refer to TrunkMod on page 467. Line numbering for upgrades ModuleCartridgeMICS 1.0 and 1.1 linesMICS 2.0, 3.0, 4.0, and 5.0 linesMICS 6.0 lines Mod 08 Cd1-Mod849-5249-5661-68 Cd2-Mod853-5657-6469-76 Cd3-Mod857-6065-7277-84 Mod 07 Cd1-Mod761-6473-8085-92 Cd2-Mod765-6881-8893-100 Cd3-Mod769-7289-96101-108 Mod 06 Cd1-Mod673-7697-100109-112 Cd2-Mod677-80101-104113-116 Cd3-Mod681-84105-108117-120 Mod 05 Cd1-Mod585-88109-112121-124 Cd2-Mod589-92113-116125-128 Cd3-Mod593-96117-120129-132
206 / Planning the installation Modular ICS 6.0 Installer GuideP0992638 03 Upgrading ILG functionality with hunt groups In MICS 4.0, Hunt groups replaced ILG functions from previous versions of MICS. The hunt group broadcast mode contains the equivalent of ILG functionality. Hunt groups allow the following call programming: calls can be queued when all the members in a hunt group are busy call forwards are overridden by the hunt group routing, allowing calls to be distributed to other members in the hunt group in a way that does not depend on the busy situation of its members the ring / call distribution pattern can be programmed to determine who receives what call and in what order an overflow position can be programmed to another hunt group sequential and rotary modes are also available to provide versatility to hunt group configurations Mod 04 Cd1-Mod497-100121-124133-136 Cd2-Mod4101-104125-128137-140 Cd3-Mod4105-108129-132141-144 Mod 03 Cd1-Mod3109-112133-136145-148 Cd2-Mod3113-116137-140149-152 Cd3-Mod3117-120141-144153-156 Target lines145-272 145-336 (expanded)157-284 157-348 (expanded) ModuleCartridgeMICS 1.0 and 1.1 linesMICS 2.0, 3.0, 4.0, and 5.0 linesMICS 6.0 lines
Planning the installation / 207 P0 99 26 38 03 Modula r IC S 6 .0 In sta ll e r G uid e For more information on hunt groups, see System prgrming on page 389. Planning Hospitality functions MICS 4.1 introduced the Hospitality feature, which allows businesses such as hotels to monitor and set room conditions and status, and to program alarms from both an administrative telephone and indivi dual room telephones. Hospitality features allow the following programming: Administrative telephone (password access) – monitor and set room condition – monitor and set room occupancy – monitor and set or cancel alarms Room telephone – Allow staff to set room condition (password access) – Allow guests to set or cancel wakeup alarms
208 / Planning the installation Modular ICS 6.0 Installer GuideP0992638 03
P0992638 03Modular ICS 6. 0 Installer Guide Installation Only qualified persons should service the system. The installation and service of this unit is to be performed only by service personnel having appropriate training and experience. It is critical that installers have the necessary awareness about hazards to which they are exposed in performing a task, and of the measures required to minimize the danger to themselves or other persons. Electrical shock hazards from the telecommunication network and AC mains are possible with this equipment. To minimize risk to service personnel and users, the ICS must be connected to an outlet with a third-wire ground. In addition, all unused slots should have filler faceplates installed and the doors should be in place at the completion of any servicing. Service personnel must be alert to the possibility of high leakage currents becoming available on metal system surfaces during power line fault events near network lines. A risk point on the ICS is the power cord earth ground pin. These leakage currents normally safely flow to Protective Earth ground via the power cord. Therefore, it is mandatory that connection to a grounded outlet is performed first and removed last when cabling to the unit. Specifically, operations requiring the unit to be powered down must have the network connections (central office lines) removed first.
210 / Installation Modular ICS 6.0 Installer GuideP0992638 03 Installation checklist åtest all ISDN network connections, if any åmount the Integrated Communications System (ICS) åmount the expansion modules (as required) åinstall the Modular ICS NVRAM cartridge åinstall the Expansion Cartridge, Trunk Cartridges (DTI, PRI, or BRI cards, as required) åinstall the optional equipment åinstall power bars, as required åmount the distribution panel åcomplete the wiring åinstall the fiber cables åinstall the emergency telephone(s) åinstall the Norstar telephones åpower up the system åconnect the cables between the distribution block and the expansion modules åinstall the door åselect the default template using System Startup programming åprogram to customer requirements årecord programming details in the Programming Record åensure that all telephone keys are properly labelled åensure that all telephones are working åcheck that the system is working properly