    							Connecting the wiring / 251
    P0992638 03Modular ICS 6. 0 Installer Guide
    BRI U wiring is not polarity sensitive. 33 Red-Green ---- ---- ---- ----
    8 Green-Red ---- ---- ---- ----
    34 Red-Brown 225 T  025-026 Assigned DN
    9 Brown-Red 225 R  025-026 Assigned DN
    35 Red-Slate 226 T  027-028 Assigned DN
    10 Slate-Red 226 R  027-028 Assigned DN
    36 Black-Blue ---- ---- ---- ----
    11 Blue-Black ---- ---- ---- ----
    37 Black-Orange ---- ---- ---- ----
    12 Orange-Black ---- ---- ---- ----
    38 Black-Green 227 T  029-030 Assigned DN
    13 Green-Black 227 R  029-030 Assigned DN
    39 Black-Brown 228 T  031-032 Assigned DN
    14 Brown-Black 228 R  031-032 Assigned DN
    40 Black-Slate ---- ---- ---- ----
    15 Slate-Black ---- ---- ---- ----
    41 Yellow-Blue ---- ---- ---- ----
    16 Blue-Yellow ---- ---- ---- ----
    42
    Yellow-Orange ---- -------- ---
    17
    Orange-Yellow ---- -------- ---
    43
    Yellow-Green -------
    18
    Green-Yellow -------
    44
    Yellow-Brown -------
    19
    Brown-Yellow -------
    45
    Yellow-Slate ---- -------- ---
    20
    Slate-Yellow ---- -------- ---
    46
    Violet-Blue ---- -------- ---
    21
    Blue-Violet ---- -------- ---
    47
    Violet-Orange ---- -------- ---
    22
    Orange-Violet ---- -------- ---
    48
    Violet-Green ---- -------- ---
    23
    Green-Violet ---- -------- ---
    49
    Violet-Brown ---- -------- ---
    24
    Brown-Violet ---- -------- ---
    50
    Violet-Slate ---- -------- ---
    25
    Slate-Violet ---- -------- ---
    ICS U Interface Cards wiring  (Continued)
    Pin Wire color Port 
    (loop)Service Lines 
    (U-NT) Terminal equipment 
    (U-LT) 
    						
    							252 / Connecting the wiring
    Modular ICS 6.0 Installer GuideP0992638 03
    Wiring the BRI network interface
    A network interface provides the connection between the 
    ISDN network and the Modular ICS.
    If the card in the ICS is configured as a T-loop, the ICS is 
    wired to the network connection using an NT1. 
    See T reference points on page 51 for more information about 
    the NT1.
    Wiring for T network c onnection
    The Modular ICS supplies the NT1 functionality to a U-NT 
    loop, allowing a direct connection to the network. The 
    connection may use a plug and jack, or may be directly wired.
    Wiring for U-NT network interface  
    Pin (jack or 
    plug) NT1 connection
    (for jack)ICS and optional TE 
    connection (plug)
    1not usedoptional power source 3 (+)
    2not usedoptional power source 3 (-)
    3+Rx+Tx
    4+Tx+Rx
    5-Tx-Rx
    6-Rx-Tx
    7not usedoptional power sink 2 (-)
    8not usedoptional power sink 2 (+)
    Pin (jack 
    or plug)Norstar connection (for 
    plug to network interface 
    jack)N etwork interface connection 
    (jack)
    1not usedoptional battery status indicator (+)
    2not usedoptional battery status indicator (-)
    3not usedno connection
    4RR
    5TT 
    						
    							Connecting the wiring / 253
    P0992638 03Modular ICS 6. 0 Installer Guide
    The BRI-U Card does not use or provide optional power.
    Some installations may not use a plug and jack for connections between the ICS (NT) and the network.
    The following illustration shows the pin arrangement for a 
    Bellcore standard ISDN plug and jack. Other pin arrangements 
    are possible.
    Jack and plug pin numbering 
    6not usedno connection
    7not usedoptional power supply (-)
    8not usedoptional power supply (+)
    8  7  6  5  4  3  2  1
    1       2      3       4       5       6      7       8   
    						
    							254 / Connecting the wiring
    Modular ICS 6.0 Installer GuideP0992638 03
    DTI wiring
    Connecting the DTI to the T1 or PRI service provider
     Connecting the DTI to an  external CSU
    Pin DirectionSignal
    1Rx Ring (Rx from PSTN)
    2Rx Tip (Rx from PSTN)
    3 Rx cable shield (optional)
    4Tx Ring (Tx to PSTN)
    5Tx Tip (Tx to PSTN
    6 Tx cable shield (optional)
    7, 8 no connection
    Norstar ICS
    T1 or PRI 
    ser vice provider
    Norstar ICS
    CSU
    to DTE
    DA15 connector
    Norstar CSU
    DT1 Pin Signal Pin
    1 Rx Ring (Rx from CSU) 11
    2 Rx Tip (Rx from CSU) 3
    3 no connection
    4 Tx Ring (Tx from CSU) 9
    5 Tx Tip (Tx to CSU) 1
    6-8 no connectionT1 or PRI 
    service provider 1
    15 
    						
    							Connecting the wiring / 255
    P0992638 03Modular ICS 6. 0 Installer Guide
    Station Module wiring chart 
    Pin Wire color Port Service Telephones SM
    26 White-Blue X01 T 1
    1 Blue-White X01 R 1
    27 White-Orange X02 T 2
    2 Orange-White X02 R 2
    28 White-Green X03 T 3
    3 Green-White X03 R 3
    29 White-Brown X04 T 4
    4 Brown-White X04 R 4
    30 White-Slate X05 T 5
    5Slate-White X05 R 5
    31 Red-Blue X06 T 6
    6 Blue-Red X06 R 6
    32 Red-Orange X07 T 7
    7 Orange-Red X07 R 7
    33 Red-Green X08 T 8
    8 Green-Red X08 R 8
    34 Red-Brown X09 T 9
    9 Brown-Red X09 R 9
    35 Red-Slate X10 T 10
    10 Slate-Red X10 R 10
    36 Black-Blue X11 T 11
    11 Blue-Black X11 R 11
    37 Black-Orange X12 T 12
    12 Orange-Black X12 R 12
    38 Black-Green X13 T 13
    13 Green-Black X13 R 13
    39 Black-Brown X14 T 14
    14 Brown-Black X14 R 14
    40 Black-Slate X15 T 15
    15 Slate-Black X15 R 15
    41 Yellow-Blue X16 T 16
    16 Blue-Yellow X16 R 16
    42 Yellow-Orange ---- ---- no connection
    17 Orange-Yellow ---- ---- no connection
    43 Yellow-Green ---- ---- no connection
    18 Green-Yellow ---- ---- no connection
    44 Yellow-Brown ---- ---- no connection
    19 Brown-Yellow ---- ---- no connection
    45 Yellow-Slate ---- ---- no connection
    20 Slate-Yellow ---- ---- no connection
    46 Violet-Blue ---- ---- no connection 
    						
    							256 / Connecting the wiring
    Modular ICS 6.0 Installer GuideP0992638 03 T and R represent station connections and should not be confused with Tip and Ring on external lines. Station connec-
    tions are non-polarized.
    For an explanation of port numbering, see 
    Port numbering on the wiring charts on page 241. 21 Blue-Violet ---- ---- no connection
    47 Violet-Orange ---- ---- no connection
    22 Orange-Violet ---- ---- no connection
    48 Violet-Green ---- ---- no connection
    23 Green-Violet ---- ---- no connection
    49 Violet-Brown ---- ---- no connection
    24 Brown-Violet ---- ---- no connection
    50 Violet-Slate ---- ---- no connection
    25 Slate-Violet ---- ---- no connection
    Loop Start or CI Trunk Cartridge wiring chart 
    TC Slot Pin Wire color Port Service Line
    Slot 126 White-Blue X01 T 1
    1 Blue-White X01 R 1
    27 White-Orange X02 T 2
    2 Orange-White X02 R 2
    28 White-Green ---- No connection ----
    3 Green-White ---- No connection ----
    29 White-Brown ---- No connection ----
    4 Brown-White ---- No connection ----
    30 White-Slate X03 T 3
    5Slate-White X03 R 3
    31 Red-Blue X04 T 4
    6 Blue-Red X04 R 4
    32 Red-Orange ---- No connection ----
    7 Orange-Red ---- No connection ----
    33 Red-Green ---- No connection ----
    8 Green-Red ---- No connection ----
    Slot 234 Red-Brown X05 T 5
    9 Brown-Red X05 R 5
    35 Red-Slate X06 T 6
    10 Slate-Red X06 R 6
    36 Black-Blue ---- No connection ----
    11 Blue-Black ---- No connection ----
    37 Black-Orange ---- No connection ----
    12 Orange-Black ---- No connection ----
    38 Black-Green X07 T 7
    13 Green-Black X07 R 7
    Station Module wiring chart  (Continued)
    Pin Wire color Port Service Telephones SM 
    						
    							Connecting the wiring / 257
    P0992638 03Modular ICS 6. 0 Installer Guide
    For an explanation of port numbering, see Port numbering on the wiring charts on page 241.
    E&M/DISA Trunk Cartridge wiring chart
    Use the table, Trunk Module with E&M/DISA Trunk 
    Cartridges, on page258 when a Trunk Module has only 
    E&M/DISA Trunk Cartridges. 
    If the Norstar system is being connected to another Norstar 
    system or private branch exchange by connecting two RJ2HX/
    CA2HA distribution blocks together, use the following table 
    to determine the required cross-connections.
    Back-to-back cross-connections
    39 Black-Brown X08 T 8
    14 Brown-Black X08 R 8
    40 Black-Slate ---- No connection ----
    15 Slate-Black ---- No connection ----
    41 Yellow-Blue ---- No connection ----
    Slot 342 Yellow-Orange X09 T 9
    17 Orange-Yellow X09 R 9
    43 Yellow-Green X10 T 10
    18 Green-Yellow X10 R 10
    44 Yellow-Brown ---- No connection ----
    19 Brown-Yellow ---- No connection ----
    45 Yellow-Slate ---- No connection ----
    20 Slate-Yellow ---- No connection ----
    46 Violet-Blue X11 T 11
    21 Blue-Violet X11 R 11
    47 Violet-Orange X12 T 12
    22 Orange-Violet X12 R 12
    48 Violet-Green ---- No connection ----
    23 Green-Violet ---- No connection ----
    49 Violet-Brown ---- No connection ----
    24 Brown-Violet ---- No connection ----
    50 Violet-Slate ---- ET ----
    25 Slate-Violet ---- ET ----
    1st distribution blockTRT1R1ESGMSB
    Next distribution blockT1R1TRSBMSGE
    Loop Start or CI Trunk Cartridge wiring chart  (Continued)
    TC Slot Pin Wire color Port Service Line 
    						
    							258 / Connecting the wiring
    Modular ICS 6.0 Installer GuideP0992638 03
    Tips - When installing a mixture of E&M/DISA, DID, BRI, 
    or Loop Start Trunk Cartridges, it is important to cross-
    connect the wiring for each type of TC to a separate 
    distribution block. 
    To verify the operation of the Norstar E&M cards and the 
    target lines, wire the two E&M lines on the Norstar E&M back 
    to back.
    The cross-connections to each distribution block must always 
    begin at pins 26 and 1. To retain emergency telephone function, 
    install a Loop Start Trunk Cartridge in the left-most slot 
    (slot 1) of the TM.
    Trunk Module with E&M/DISA Trunk Cartridges 
    TC Slot Pin Wire color Port Service Line
    Slot 1 26 White-Blue X01 T 1
    1 Blue-White X01 R 1
    27 White-Orange X01 T1 1
    2 Orange-White X01 R1 1
    28 White-Green X01 E 1
    3 Green-White X01 SG 1
    29 White-Brown X01 M 1
    4 Brown-White X01 SB 1
    30 White-Slate X02 T 2
    5Slate-White X02 R 2
    31 Red-Blue X02 T1 2
    6 Blue-Red X02 R1 2
    32 Red-Orange X02 E 2
    7 Orange-Red X02 SG 2
    33 Red-Green X02 M 2
    8 Green-Red X02 SB 2
    Slot 2 34 Red-Brown X05 T 5
    9 Brown-Red X05 R 5
    35 Red-Slate X05 T1 5
    10 Slate-Red X05 R1 5
    36 Black-Blue X05 E 5
    11 Blue-Black X05 SG 5
    37 Black-Orange X05 M 5
    12 Orange-Black X05 SB 5
    38 Black-Green X06 T 6 
    						
    							Connecting the wiring / 259
    P0992638 03Modular ICS 6. 0 Installer Guide
    For an explanation of port numbering, see Port numbering on the wiring charts on page 241. 13 Green-Black X06 R 6
    39 Black-Brown X06 T1 6
    14 Brown-Black X06 R1 6
    40 Black-Slate X06 E 6
    15 Slate-Black X06 SG 6
    41 Yellow-Blue X06 M 6
    16 Blue-Yellow X06 SB 6
    Slot 3 42 Yellow-Orange X09 T 9
    17 Orange-Yellow X09 R 9
    43 Yellow-Green X09 T1 9
    18 Green-Yellow X09 R1 9
    44 Yellow-Brown X09 E 9
    19 Brown-Yellow X09 SG 9
    45 Yellow-Slate X09 M 9
    20 Slate-Yellow X09 SB 9
    46 Violet-Blue X10 T 10
    21 Blue-Violet X10 R 10
    47 Violet-Orange X10 T1 10
    22 Orange-Violet X10 R1 10
    48 Violet-Green X10 E 10
    23 Green-Violet X10 SG 10
    49 Violet-Brown X10 M 10
    24 Brown-Violet X10 SB 10
    50 Violet-Slate ----reserved ----
    25 Slate-Violet ----reserved ----
    Trunk Module with DID Trunk Cartridges 
    TC Slot Pin Wire color Port Service Line
    Slot 1 26 White-Blue X01 T 1
    1 Blue-White X01 R 1
    27 White-Orange X02 T 2
    2 Orange-White X02 R 2
    28 White-Green ---- No connection ----
    3 Green-White ---- No connection ----
    29 White-Brown ---- CCI NC1 ----
    4 Brown-White ---- CCI Com1 ----
    30 White-Slate X03 T 3
    5 Slate-White X03 R 3
    31 Red-Blue X04 T 4
    Trunk Module with E&M/DISA Trunk Cartridges  (Continued)
    TC Slot Pin Wire color Port Service Line 
    						
    							260 / Connecting the wiring
    Modular ICS 6.0 Installer GuideP0992638 03 For an explanation of port numbering, see 
    Port numbering on the wiring charts on page 241.
    For CCI connections in Service column: NC1 stands for the normally closed relay and Com1 the common relay. 
    CCI signaling is not supported by all carriers. For carriers or installations that do not use CCI signaling, the CCI and ET 
    connections should be treated as “no connection”. CCI wiring is a non-standard  wi ring arrangement which has been 
    submitted to the DOC.6 Blue-Red X04 R 4
    32 Red-Orange ---- No connection ----
    7 Orange-Red ---- No connection ----
    33 Red-Green ---- No connection ----
    8 Green-Red ---- No connection ----
    Slot 2 34 Red-Brown X05 T 5
    9 Brown-Red X05 R 5
    35 Red-Slate X06 T 6
    10 Slate-Red X06 R 6
    36 Black-Blue ---- No connection ----
    11 Blue-Black ---- No connection ----
    37 Black-Orange ---- CCI NC1 ----
    12 Orange-Black ---- CCI Com1 ----
    38 Black-Green X07 T 7
    13 Green-Black X07 R 7
    39 Black-Brown X08 T 8
    14 Brown-Black X08 R 8
    40 Black-Slate ---- No connection ----
    15 Slate-Black ---- No connection ----
    41 Yellow-Blue ---- No connection ----
    16 Blue-Yellow ---- No connection ----
    Slot 3 42 Yellow-Orange X09 T 9
    17 Orange-Yellow X09 R 9
    43 Yellow-Green X10 T 10
    18 Green-Yellow X10 R 10
    44 Yellow-Brown ---- No connection ----
    19 Brown-Yellow ---- No connection ----
    45 Yellow-Slate ---- CCI NC1 ----
    20 Slate-Yellow ---- CCI Com1 ----
    46 Violet-Blue X11 T 11
    21 Blue-Violet X11 R 11
    47 Violet-Orange X12 T 12
    22 Orange-Violet X12 R 12
    48 Violet-Green ---- No connection ----
    23 Green-Violet ---- No connection ----
    49 Violet-Brown ---- No connection ----
    24 Brown-Violet ---- No connection ----
    50 Violet-Slate ---- ET ----
    25 Slate-Violet ---- ET ----
    Trunk Module with DID Trunk Cartridges  (Continued)
    TC Slot Pin Wire color Port Service Line 
    						