Nortel Modular Ics 6.0 Installer Guide
Have a look at the manual Nortel Modular Ics 6.0 Installer Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 211 Nortel manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Norstar and Meridian are trademarks of Nortel Networks © Copyright Nortel Networks 2002 Modular ICS 6.0 Installer Guide 1-800-4 NORTEL www.nortel.com/norstar P0992638 03 Printed in Canada
P0992638 03Modular ICS 6.0 Installer Guide Table of Contents Regulations 21 Safety and installation 21 For equipment with internal power supplies 21 For equipment with external power supplies 22 Important safety instructions 22 North American regulations 23 Federal Communication Commission (FCC) Notice Radio/ TV interference 23 Devices intended to be connected to the Public Switched Telephone Network 24 Signaling method 27 Ringer Equivalence Number 27 Hearing aid compatibility 28 Use of a music source 28 Programming emergency numbers 28 CE marking 29 How to use this document 31 What’s new with Norstar 33 New features for version 6.0 33 Functionality changes for version 6.0 35 Welcome to ISDN 37 Comparing ISDN to Analog 38 Type of ISDN service 38 B channels 39 D channels 39 ISDN layers 39 ISDN bearer capability 40 Services and features for ISDN PRI and BRI 41 PRI services and features 41 BRI services and features 42 Feature descriptions 43 Network name display 43 Message Waiting Indicator (MWI) 44 Name and number blocking 44
iv / Table of Contents Modular ICS 6.0 Installer GuideP0992638 03 External call forwarding 44 MCDN trunk features 45 Call by Call service selection for PRI 45 Emergency 911 dialing 46 MCID (Profile 2) 47 Network Call Diversion (Profile 2) 47 DTI card configured as a PRI card 47 ISDN hardware 48 DTI Card configured as PRI 48 BRI Card 48 BRI-U2 and BRI-U4 card 49 BRI-ST card 49 U-LT reference point 49 U-NT reference points 50 S reference point 51 T reference points 51 Clock source for ISDN cards 52 Other ISDN BRI equipment: NT1 54 ISDN standards compatibility 54 Working with ISDN 55 Planning your ISDN network 55 Ordering ISDN PRI 55 Ordering ISDN PRI service in Canada 55 Ordering ISDN PRI service in United States 56 Ordering ISDN BRI 56 Ordering service in Canada 56 Ordering ISDN service in the U.S. 56 Supported ISDN protocols 58 ISDN programming 58 Programming ISDN PRI resources 58 Programming ISDN BRI resources 60 Programming ISDN PRI lines 62 Programming ISDN BRI lines 63 Programming Direct Inward System Access (DISA) on PRI trunks 64 Programming ISDN equipment 65 Terminal equipment for BRI cards 65 Devices on an S or LT loop (BRI cards only) 65 ISDN router 67 D-packet service (BRI cards only) 68 POSTA for ISDN BRI 69
Table of Contents / v P0992638 03Modular ICS 6.0 Installer Guide Point-of-sale terminal adapter 69 Trunks and target lines 71 Trunk operating modes (T1) 72 Ground start trunks (T1 only) 72 DID trunks 73 Analog loop start trunks 75 Analog E&M trunks 77 BRI trunks 79 PRI trunks 79 Target lines 80 Remote system access 81 Use system features during a remote call 81 Remote access on loop start and E&M trunks 82 Remote access on a private network 82 Remote access on Direct Inward Dial (DID) trunks 83 Remote access on PRI trunks 83 Controlling system access 85 Class of Service 85 Restriction filters 86 Direct inward system access (DISA) 89 Networking with Norstar 91 Tie-line networking 92 Norstar behind a PBX 93 Dialing plans 94 Dialing plan using public lines 96 Destination code numbering in a network 96 Dialing plan using E&M lines 97 Dialing plans with shared line pools 102 Call-by-Call Services Example 104 Norstar Configuration 106 PRI dialing plan example for two-way DID 108 Static DID and two-way DID 109 Private networking using PRI SL-1 110 SL-1 networking features 110 Features specific to Advanced Private Network 111 Private Network Tandem calling 112
vi / Table of Contents Modular ICS 6.0 Installer GuideP0992638 03 Calls originating from the public network 113 Calls originating in the private network 116 Routing for tandem networks 119 Advanced Private Networking 121 Networking using routing codes 121 MCDN Private Networking 126 Using a UDP dialing plan 127 Using a CDP dialing plan 130 MCDN trunk call features 133 Network Call Redirection Information 134 ISDN Call Connection Limitation 136 Trunk Route Optimization 138 Trunk Anti-tromboning 140 MCDN voice mail/auto attendant call features 141 Camp-on 142 Break-in 143 Central voice mail and Auto Attendant with Norstar 146 Configuring centralized voice mail 146 Local system 147 Remote system 148 Using centralized voice mail 149 Configuring Centralized Auto Attendant (CAA) 150 Assigning PNIs 150 Assigning PNIs for adjacent nodes 151 Local system 151 Remote system 152 Voice mail configuration 154 Customer Use 155 Public network 155 Private network 159 Call one or more Norstar telephones 159 Use tie lines to other nodes in the private network 160 Select lines to the public network 161 Select E&M trunks to the private network 162 Norstar Line Redirection feature 163 ETSI MCDN and network features 165 Network Call Diversion 165 Allowing NCD 166 Feature description 166 Programming and restrictions 167 Selective Line Redirection 168 Programming Extensions 169
Table of Contents / vii P0992638 03Modular ICS 6.0 Installer Guide Enhanced Caller ID 169 Malicious caller identification (MCID) 170 Programming MCID capability 170 Data Solutions 173 Examples of ISDN Scenarios 173 ISDN applications 173 Video conferencing and video telephony 173 Desktop conferencing 173 File transfer 174 Telecommuting 174 Group 4 fax 174 Remote LAN access 174 Leased line backup 174 LAN to LAN bridging 175 Internet and database access 175 Planning the installation 177 Planning checklist 178 Hardware 178 Initial configuration 178 System configuration 179 Required equipment 179 Expansion equipment 180 Optional equipment 181 Equipment for installing the ICS and modules 182 Location requirements 182 Electrical requirements 184 Configuring Trunk Cartridges 185 Configuring Station Modules 186 Internal wiring requirements 186 Norstar loop 186 ISDN S reference point (S Loop) 187 System overview 188 Upgrading your Norstar system 189 Supported upgrades in MICS 6.0 192 Upgrading from MICS 6.0 to MICS-XC 6.0 196 Trunk and Station Modules 199 Global Analog Trunk Cartridge/CLI Cartridge 200 Off-core DTI card 201 Replacing a Modular 8x24 KSU 201 Trunk module line numbering 205
viii / Table of Contents Modular ICS 6.0 Installer GuideP0992638 03 Upgrading ILG functionality with hunt groups 206 Planning Hospitality functions 207 Installation 209 Installation checklist 210 Testing the ISDN BRI network connection 211 Installing the cartridges 213 Mounting the modules 215 Installation tips 217 Installing the ROM Software Cartridge 219 Inserting a cartridge 221 Terminating resistors on BRI-ST Cards 222 Shorting straps on a BRI-ST card 223 Connecting expansion modules 224 Order of connection 224 Analog Station Module 224 Installing fiber cables 230 Fiber cable management system 231 Using the fiber cable management system 232 Using the fiber spool 234 Making fiber connections 235 Routing fiber cables 236 Connecting the wiring 237 Connecting the wiring to the distribution panel 237 Wiring charts 241 Port numbering on the wiring charts 241 Integrated Communications System (ICS) 241 BRI Wiring charts 248 Wiring the BRI network interface 252 DTI wiring 254 E&M/DISA Trunk Cartridge wiring chart 257 DID supervisory signaling 261 Emergency transfer conditions 261 Emergency telephone 265 Moving telephones 267 Installing ISDN BRI terminal equipment 268 S or T wiring for terminal equipment 268 S or T extension wiring configurations 268 Additional power 269 U-LT wiring for terminal equipment 270
Table of Contents / ix P0992638 03Modular ICS 6.0 Installer Guide Installing optional equipment 271 Auxiliary ringer (customer supplied) 271 Auxiliary ringer programming 271 External music source (customer supplied) 272 External music source programming 272 External paging system (customer supplied) 273 Powering up the system 274 Check the power 275 Programming 277 Programming overview 278 Profile, Dialpad and Startup programmin g279 Installer or System Coordinator Plus programming 280 System Coordinator programming 281 Admin/Basic programming 281 Programming tools 282 The programming overlay 283 Using the telephone buttons for programming 284 Special characters on the display 285 The display buttons 285 The Norstar Programming Record 287 Exiting 287 Viewing your programming updates 287 Entering numbers 288 Viewing long telephone numbers 288 Setting up User Preferences 289 Copying telephone programming 290 System ID 293 Reviewing programmed settings 293 Viewing the programming for a telephone 294 Viewing the programming for a line 294 Programming sequence 295 Profiles and Dialpads 296 Profile programming 296 Profile parameters 296 Changing the profile 299 Dialpad programmin g300 Startup programmin g301 Performing Startup 301 Changing the default template 302
x / Table of Contents Modular ICS 6.0 Installer GuideP0992638 03 Changing the starting DN 302 Programming 304 Entering programming for installers 305 Entering programming for system coordinators 306 Entering programming using other passwords 307 Terminals&Sets 308 Line access 308 Line assignment 309 Appearances 310 Line pool access 312 Prime line 313 Intercom keys 314 Answer DNs 314 OLI # 315 Capabilities 317 ATA settings 319 ATA ans timer 319 ATA use 320 ATA dvc 320 MsgIndicate 320 Name 320 User prefernces 321 Restrictions 322 Filters 322 Default filters 324 Set restrns 327 Filters 327 Set lock 328 Allow last no 328 Allow saved no 328 Allow link 328 Line/set restrns 329 Telco features 330 Feature assignment (CLID alignment) 330 Caller ID set 330 Extl VMsg set 331 1stDisplay 331 Called ID 332 Log space 332 Lines 333 Trunk/Line data 333