    							Connecting the wiring / 241
    P0992638 03Modular ICS 6. 0 Installer Guide
    Wiring charts
    Port numbering on the wiring charts
    The port number listed on the wiring charts is useful in 
    tracking down faults during a maintenance session where error 
    codes appear on the alarm telephone display. Refer to Alarm 
    codes on page 506. 
    The port numbers (for example: XX12) on the Trunk Cartridge 
    and Station Module wiring charts have two components:
    XX corresponds to the number that appears on the face of 
    the Expansion Cartridge port that the Trunk Module or 
    Station Module is connected to.
    digits (for example, 01 or 12) identify an individual port 
    number associated with that module.
    For example:
    The code 812 appearing as part of an error message for a Trunk 
    Module indicates that the problem is with Expansion Cartridge 
    port #8 and internal port 12. The corresponding Trunk Module 
    pins on the distribution block are pin  47 (violet-orange) and 
    pin 22 (orange-violet).
    Integrated Communications System (ICS)
    In the charts on the following pages, notice that the ICS has 
    two internal modules, ICS #1 and ICS #2. ICS #1 handles 
    telephones and auxiliary equipment. ICS #2 handles lines.
    B1 and B2 directory numbers
    The terms B1 and B2 correspond to channels on Norstar for 
    transmitting voice and data. Each DN port number has a B1 
    DN and a B2 DN. Devices such as the Norstar and Business  
    						
    							242 / Connecting the wiring
    Modular ICS 6.0 Installer GuideP0992638 03
    Series telephones use only the B1 DN. Other devices may need 
    both B1 and B2 channels, therefore requiring B1 and B2 DNs.
    Non-expanded system (ICS alone) numbering
    Two-port Expansion Cartridge and ICS numbering
    Six-port Expansion Cartridge and ICS numbering
    Module LinesLine portsB1 DNB2 DNDN ports 
    ICS (#2)001-060201-260— —— —— —
    ICS (#1)— —— —21-5253-84101-132
    Module LinesLine portsB1 DNB2 DNDN ports
    Mod 04133-144401-412269-284333-348401-416
    Mod 03145-156301-312253-268317-332301-316
    ICS (#2)001-060201-260— —— —— —
    ICS (#1)— —— —221-252285-316101-132
    Module Lines Line 
    portsB1 DN B2 DN DN 
    ports 
    Mod 08061-084 801-812 333-348 461-476 801-816
    Mod 07085-108 701-712 317-332 445-460 701-716
    Mod 06109-120 601-612 301-316 429-444 601-616
    Mod 05121-132 501-512 285-300 413-428 501-516
    Mod 04133-144 401-412 269-284 397-412 401-416
    Mod 03145-156 301-312 253-268 381-396 301-316
    ICS (#2)001-060 201-260— —— —— —
    ICS (#1)— —— —221-252 349-380 101-132 
    						
    							Connecting the wiring / 243
    P0992638 03Modular ICS 6. 0 Installer Guide
    Twelve-port expanded system and ICS numbering
    ModuleLinesLine portsB1 DNB2 DNDN ports 
    Mod 14— —— —— —— —— —
    Mod 13— —— —— —— —— —
    Mod 12— —— —397-412589-6041201-1216
    Mod 11— —— —381-396573-5881101-1116
    Mod 10— —— —365-380557-5721001-1016
    Mod 09— —— —349-364541-556901-916
    Mod 08061-084801-812333-348525-540801-816
    Mod 07085-108701-712317-332509-524701-716
    Mod 06109-120601-612301-316493-508601-616
    Mod 05121-132501-512285-300477-492501-516
    Mod 04133-144401-412269-284461-476401-416
    Mod 03145-156301-312253-268445-460301-316
    ICS (#2)001-060201-260— —— —— —
    ICS (#1)— —— —221-252413-444101-132
    Tips - A 12-port expanded system is available on a 
    MICS-XC 6.0 system.
    Depending on your system configuration, BRI-ST, BRI-U2, 
    and BRI-U4 cards can only reside in certain trunk modules. 
    On a Midi system, the cards must be in trunk modules 03 or 04. 
    On a Maxi or Mega system, the cards must be in trunk modules 
    07 or 08. The cards can reside in the ICS regardless of system 
    size.
    Expansion module #13 and #14 are reserved for Companion 
    Wireless capability. Refer to your Modular ICS Companion 
    Installer Guide for information about using expansion module 
    #13 and #14. 
    						
    							244 / Connecting the wiring
    Modular ICS 6.0 Installer GuideP0992638 03
    ICS telephone wiring chart
    Port 3 is the bottom fiber cable port on both the two-port and 
    the six-port Expansion Cartridge in slot 2. Port 9 is the bottom 
    fiber cable port located on the left most expansion card in slot 1.
    B1 and B2 directory numbers reflect the default numbering 
    scheme.
    If you expand your system after initial installation and 
    programming, there may appear to be gaps in your B1 DN 
    numbering. This is because the system has already assigned DN 
    numbers to B2 channels. You can correct these gaps by 
    performing Startup programming and resetting the system 
    memory, or by changing the individual DNs. See 
    Change DNs 
    under 
    System prgrming.
    Startup programming erases the system 
    memory.
    Pin Wire color Port Service Devices (ICS) Default DN
    26 White-Blue 101 T 1
    1 Blue-White 101 R 1 21/221/2221
    27 White-Orange 102 T 2
    2 Orange-White 102 R 2 22/222/2222
    28 White-Green 103 T 3
    3 Green-White 103 R 3 23/223/2223
    29 White-Brown 104 T 4
    4 Brown-White 104 R 4 24/224/2224
    30 White-Slate 105 T 5
    5 Slate-White 105 R 5 25/225/2225
    31 Red-Blue 106 T 6
    6 Blue-Red 106 R 6 26/226/2226
    32 Red-Orange 107 T 7
    7 Orange-Red 107 R 7 27/227/2227
    33 Red-Green 108 T 8
    8 Green-Red 108 R 8 28/228/2228
    34 Red-Brown 109 T 9
    9 Brown-Red 109 R 9 29/229/2229 
    						
    							Connecting the wiring / 245
    P0992638 03Modular ICS 6. 0 Installer Guide
    T and R represent station connections and should not be confused with Tip and Ring on external lines. Station conn ec-
    tions are non-polarized.
    ICS telephone and auxiliary equipment wiring chart 
    35 Red-Slate 110 T 10
    10 Slate-Red 110 R 10 30/230/2230
    36 Black-Blue 111 T 11
    11 Blue-Black 111 R 11 31/231/2231
    37 Black-Orange 112 T 12
    12 Orange-Black 112 R 12 32/232/2232
    38 Black-Green 113 T 13
    13 Green-Black 113 R 13 33/233/2233
    39 Black-Brown 114 T 14
    14 Brown-Black 114 R 14 34/234/2234
    40 Black-Slate 115 T 15
    15 Slate-Black 115 R 15 35/235/2235
    41 Yellow-Blue 116 T 16
    16 Blue-Yellow 116 R 16 36/236/2236
    42 Yellow-Orange 117 T 17
    17 Orange-Yellow 117 R 17 37/237/2237
    43 Yellow-Green 118 T 18
    18 Green-Yellow 118 R 18 38/238/2238
    44 Yellow-Brown 119 T 19
    19 Brown-Yellow 119 R 19 39/239/2239
    45 Yellow-Slate 120 T 20
    20 Slate-Yellow 120 R 20 40/240/2240
    46 Violet-Blue 121 T 21
    21 Blue-Violet 121 R 21 41/241/2241
    47 Violet-Orange 122 T 22
    22 Orange-Violet 122 R 22 42/242/2242
    48 Violet-Green 123 T 23
    23 Green-Violet 123 R 23 43/243/2243
    49 Violet-Brown 124 T 24
    24 Brown-Violet 124 R 24 44/244/2244
    50 Violet-Slate ---- ---- no connection ----
    25 Slate-Violet ---- ---- no connection ----
    Pin Wire color Port Service Telephones 
    (ICS)Default DN
    26 White-Blue 125 T 25
    1 Blue-White 125 R 25 45/245/2245
    27 White-Orange 126 T 26
    2 Orange-White 126 R 26 46/246/2246
    28 White-Green 127 T 27
    Pin Wire color Port Service Devices (ICS) Default DN 
    						
    							246 / Connecting the wiring
    Modular ICS 6.0 Installer GuideP0992638 03 3 Green-White 127 R 27 47/247/2247
    29 White-Brown 128 T 28
    4 Brown-White 128 R 28 48/248/2248
    30 White-Slate 129 T 29
    5 Slate-White 129 R 29 49/249/2249
    31 Red-Blue 130 T 30
    6 Blue-Red 130 R 30 50/250/2250
    32 Red-Orange 131 T 31
    7 Orange-Red 131 R 31 51/251/2251
    33 Red-Green 132 T 32
    8 Green-Red 132 R 32 52/252/2252
    34 Red-Brown ---- ---- no connection
    9 Brown-Red ---- ---- no connection
    35 Red-Slate ---- ---- no connection
    10 Slate-Red ---- ---- no connection
    36 Black-Blue ---- ---- no connection
    11 Blue-Black ---- ---- no connection
    37 Black-Orange ---- ---- no connection
    12 Orange-Black ---- ---- no connection
    38 Black-Green ---- ---- no connection
    13 Green-Black ---- ---- no connection
    39 Black-Brown ---- ---- no connection
    14 Brown-Black ---- ---- no connection
    40 Black-Slate ---- T Page
    15 Slate-Black ---- R Page
    41 Yellow-Blue ---- Make External page
    16 Blue-Yellow ---- Common External page
    42 Yellow-Orange ---- T Music
    17 Orange-Yellow ---- R Music
    43 Yellow-Green ---- ---- reserved
    18 Green-Yellow ---- ---- reserved
    44 Yellow-Brown ---- Make Auxiliary ringer - 1
    19 Brown-Yellow ---- Common Auxiliary ringer - 1
    45 Yellow-Slate ---- ---- reserved
    20 Slate-Yellow ---- ---- reserved
    46 Violet-Blue ---- ---- no connection
    21 Blue-Violet ---- ---- no connection
    47 Violet-Orange ---- ---- reserved
    22 Orange-Violet ---- ---- reserved
    48 Violet-Green ---- ---- reserved
    23 Green-Violet ---- ---- reserved
    49 Violet-Brown ---- ---- reserved
    Pin Wire color Port Service Telephones 
    (ICS)Default DN 
    						
    							Connecting the wiring / 247
    P0992638 03Modular ICS 6. 0 Installer Guide
    T and R represent station connections and should not be confused with Tip and Ring on external lines. Station conn ec-
    tions are non-polarized.
    ICS external loop start lines wiring
    24 Brown-Violet ---- ---- reserved
    50 Violet-Slate ---- ---- reserved
    25 Slate-Violet ---- ---- reserved
    Pin Wire color Port Service Line
    26 White-Blue 201 T 1
    1 Blue-White 201 R 1
    27 White-Orange 202 T 2
    2 Orange-White 202 R 2
    28 White-Green
    ---- --------
    3 Green-White
    ---- --------
    29 White-Brown
    ---- --------
    4 Brown-White
    ---- --------
    30 White-Slate 203 T 3
    5 Slate-White 203  R 3
    31 Red-Blue 204 T 4
    6 Blue-Red 204  R 4
    32 Red-Orange
    ---- --------
    7 Orange-Red
    ---- --------
    33 Red-Green
    ---- --------
    8 Green-Red
    ---- --------
    34 Red-Brown 225 T 25
    9 Brown-Red 225 R 25
    35
    Red-Slate226 T 26
    10
    Slate-Red226 R 26
    36
    Black-Blue ---- --------
    11
    Blue-Black ---- --------
    37
    Black-Orange ---- --------
    12
    Orange-Black ---- --------
    38
    Black-Green227 T 27
    13
    Green-Black227 R 27
    39
    Black-Brown228 T 28
    14
    Brown-Black228 R 28
    40
    Black-Slate ---- --------
    15
    Slate-Black ---- --------
    41
    Yellow-Blue ---- --------
    16
    Blue-Yellow ---- --------
    42
    Yellow-Orange ---- --------
    17
    Orange-Yellow ---- --------
    Pin Wire color Port Service Telephones 
    (ICS)Default DN 
    						
    							248 / Connecting the wiring
    Modular ICS 6.0 Installer GuideP0992638 03 For an explanation of port numbering, see 
    Port numbering on the wiring charts on page 241.
    BRI Wiring charts
    A BRI Card in Slot 4 uses loops 201 through 204. A BRI card 
    in Slot 3 uses loops 225 through 228. Because a BRI-U2 Card 
    has only two loops, it only uses the first two loop numbers 
    (201-202 and 225-226) when it occupies an ICS slot.
    The loops appearing on a BRI card may be automatically 
    assigned lines, or assigned one or more ISDN DNs in 
    Hardware. If the loop is configured as T or NT, lines are 
    automatically assigned. If the loop is configured as S or LT, 
    you can assign one or more ISDN DNs to the loop.
    The emergency telephone connections (ET2 and ET1) cannot 
    be used if a BRI card is installed in Slot 3 or Slot 4, 
    respectively.
    43
    Yellow-Green ----TET1
    18
    Green-Yellow ----RET1
    44
    Yellow-Brown ----TET2
    19
    Brown-Yellow ----RET2
    45
    Yellow-Slate ---- --------
    20
    Slate-Yellow ---- --------
    46
    Violet-Blue ---- --------
    21
    Blue-Violet ---- --------
    47
    Violet-Orange ---- --------
    22
    Orange-Violet ---- --------
    48
    Violet-Green ---- --------
    23
    Green-Violet ---- --------
    49
    Violet-Brown ---- --------
    24
    Brown-Violet ---- --------
    50
    Violet-Slate ---- --------
    25
    Slate-Violet ---- --------
    Pin Wire color Port Service Line 
    						
    							Connecting the wiring / 249
    P0992638 03Modular ICS 6. 0 Installer Guide
    For more information about configuring BRI cards refer to 
    BRI Card on page 48 in Welcome to ISDN and BRI card on 
    page 471 in Hardware.
    ICS ST Interface  Cards wiring 
    Pin Wire color Port (loop) Service Lines (T-loop) Terminal 
    equipment
    (S loop)
    26 White-Blue 201 +Tx  001-002 Assigned DN
    1 Blue-White 201 -Tx  001-002 Assigned DN
    27 White-Orange 201 +Rx  001-002 Assigned DN
    2 Orange-White 201 -Rx  001-002 Assigned DN
    28 White-Green 202 +Tx  003-004 Assigned DN
    3 Green-White 202 -Tx  003-004 Assigned DN
    29 White-Brown 202 +Rx  003-004 Assigned DN
    4 Brown-White 202 -Rx  003-004 Assigned DN
    30 White-Slate 203 +Tx  005-006 Assigned DN
    5 Slate-White 203 -Tx  005-006 Assigned DN
    31 Red-Blue 203 +Rx  005-006 Assigned DN
    6 Blue-Red 203 -Rx  005-006 Assigned DN
    32 Red-Orange 204 +Tx  007-008 Assigned DN
    7 Orange-Red 204 -Tx  007-008 Assigned DN
    33 Red-Green 204 +Rx  007-008 Assigned DN
    8 Green-Red 204 -Rx  007-008 Assigned DN
    34 Red-Brown 225 +Tx  025-026 Assigned DN
    9 Brown-Red 225 -Tx  025-026 Assigned DN
    35 Red-Slate 225 +Rx  025-026 Assigned DN
    10 Slate-Red 225 -Rx  025-026 Assigned DN
    36 Black-Blue 226 +Tx  027-028 Assigned DN
    11 Blue-Black 226 -Tx  027-028 Assigned DN
    37 Black-Orange 226 +Rx  027-028 Assigned DN
    12 Orange-Black 226 -Rx  027-028 Assigned DN
    38 Black-Green 227 +Tx  029-030 Assigned DN
    13 Green-Black 227 -Tx  029-030 Assigned DN
    39 Black-Brown 227 +Rx  029-030 Assigned DN
    14 Brown-Black 227 -Rx  029-030 Assigned DN
    40 Black-Slate 228 +Tx  031-032 Assigned DN
    15 Slate-Black 228 -Tx  031-032 Assigned DN
    41 Yellow-Blue 228 +Rx  031-032 Assigned DN
    16 Blue-Yellow 228 -Rx  031-032 Assigned DN
    42
    Yellow-Orange ---- -------- --- 
    						
    							250 / Connecting the wiring
    Modular ICS 6.0 Installer GuideP0992638 03 BRI S or T wiring is polarity sensitive.
    Tx and Rx are Transmit and Receive for Norstar.17
    Orange-Yellow ---- -------- ---
    43
    Yellow-Green ----TET1 ---
    18
    Green-Yellow ----RET1 ---
    44 
    Yellow-Brown ----TET2 ---
    19 
    Brown-Yellow ----RET2 ---
    45 
    Yellow-Slate ---- -------- ---
    20 
    Slate-Yellow ---- -------- ---
    46 
    Violet-Blue ---- -------- ---
    21 
    Blue-Violet ---- -------- ---
    47 
    Violet-Orange ---- -------- ---
    22 
    Orange-Violet ---- -------- ---
    48 
    Violet-Green ---- -------- ---
    23 
    Green-Violet ---- -------- ---
    49 
    Violet-Brown ---- -------- ---
    24 
    Brown-Violet ---- -------- ---
    50 
    Violet-Slate ---- -------- ---
    25 
    Slate-Violet ---- -------- ---
    ICS U Interface Cards wiring 
    Pin Wire color Port 
    (loop)Service Lines 
    (U-NT) Terminal equipment 
    (U-LT)
    26 White-Blue 201 T  001-002 Assigned DN
    1 Blue-White 201 R  001-002 Assigned DN
    27 White-Orange 202 T  003-004 Assigned DN
    2 Orange-White 202 R  003-004 Assigned DN
    28 White-Green ---- ---- ---- ----
    3 Green-White ---- ---- ---- ----
    29 White-Brown ---- ---- ---- ----
    4 Brown-White ---- ---- ---- ----
    30 White-Slate 203 T  005-006 Assigned DN
    5 Slate-White 203 R  005-006 Assigned DN
    31 Red-Blue 204 T  007-008 Assigned DN
    6 Blue-Red 204 R  007-008 Assigned DN
    32 Red-Orange ---- ---- ---- ----
    7 Orange-Red ---- ---- ---- ----
    ICS ST Interface Cards wiring  (Continued)
    Pin Wire color Port (loop) Service Lines (T-loop) Terminal 
    equipment
    (S loop) 
    						