Home > NEC > Communications System > NEC Neax 2400 Imx Wireless System Manual

NEC Neax 2400 Imx Wireless System Manual

    Download as PDF Print this page Share this page

    Have a look at the manual NEC Neax 2400 Imx Wireless System Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							CHAPTER 3 ND-70290 (E)
    Pag e 6 4
    Revision 3.0
    PA-4CSID (CSINT)
    Figure 3-8  Connecting Route Diagram
    MDF
    PIM
    NT1 A
    B
    CSINTA
    B 
    						
    							ND-70290 (E) CHAPTER 3
    Page 65
    Revision 3.0
    PA-4CSIE (CSINT)
    PA-4CSIE (CSINT)  : ZT (Zone Transceiver) Interface
    1. General Functions
    This circuit card is designed to provide the ISDN S interface to the Zone Transceiver (ZT).
    Specifications and functions of this circuit card are shown below.
     A maximum of four ZTs can be accommodated in one 4CSIE circuit card.
     Interface with ZTs is based on the ISDN standard interface, though the multi-point connection of the
    ZTs is not available.
     I.430, Q.921 Interface
     (Each B Channel of 32 kbps in the 2B+D (B=64 kbps) can be used as two channels.)
     Feed functions to ZT: 48 Vtyp, maximum of 250 mA, feed polarity: reverse
     Equipped with 32k ADPCM (TSW: 64 kbps, ZT: 32 kbps)
     Burst synchronization function of 5 ms (multi-frame) to ZT
     Provided with 16 channels of PB (DTMF) sender
    Figure 3-9  Location of Card in System
    2. Mounting Location of Circuit Card and Its Conditions
     Mounting location of circuit card: Universal slot of the PIM 
    Conditions: 12 CSINT circuit cards can be mounted in one PIM.
    ZTPS
    PS
    TSW
    PLO PA-4CSIE
    Equivalent to I.430
    5ms 
    						
    							CHAPTER 3 ND-70290 (E)
    Pag e 6 6
    Revision 3.0
    PA-4CSIE (CSINT)
    3. Lamp, Key, Connector and Their Location
    The following diagram shows the location of Lamp, Key and Connectors.
    Figure 3-10  Lamp, Key and Connectors : PA-4CSIE
    OPE
    MB
    SW10
    NOPE
    MODE
    L3
    L2
    L1
    L0 BL34
    BL33
    BL32
    LYR3
    PWR3
    BL24
    BL23
    BL22
    LYR2
    PWR2
    BL14
    BL13
    BL12
    LYR1
    PWR1
    SYNCBL04
    BL03
    BL02
    LYR0
    PWR0
    SW12 SW11
    MBR 
    						
    							ND-70290 (E) CHAPTER 3
    Page 67
    Revision 3.0
    PA-4CSIE (CSINT)
    4. Lamp Indication
    Shown below are the contents of lamp indication on this circuit card.
    n=0~3
    Note 1:B2 through B4 channels represent channel names of 32k ADPCM.
    LAMP NAME COLOR MEANING
    OPE Green Remains lit when this card is operating normally.
    NOPE Red Remains lit when this card is in make-busy state.
    BLn4 Green  Remains lit when B4 channel of the line #n is communicating  
    Note
    Flashing Flashes while the corresponding circuit is in make-busy state (60 IPM).
    OFF Remains off when the corresponding circuit is idle.
    BLn3 Green Remains lit when B3 channel of the line #n is communicating  
    Note
    Flashing Flashes while the corresponding circuit is in make-busy state (60 IPM).
    OFF Remains off when the corresponding circuit is idle.
    BLn2 Green Remains lit when B2 channel of line #n is communicating  
    Note
    Flashing Flashes while the corresponding circuit is in make-busy state (60 IPM).
    OFF Remains off when the corresponding circuit is idle.
    LYRn Green Remains lit when the layer 2 link of line #n is established
    Flashing Flashes when layer 1 of the line #n is synchronized (120 IPM).
    OFF Layer 1 and Layer 2 have not been established.
    PWRn Red Lights when the power supply of the line #n fails.
    SYNC Red Flashes when the synchronous timing of 5 ms is disconnected. 
    						
    							CHAPTER 3 ND-70290 (E)
    Pag e 6 8
    Revision 3.0
    PA-4CSIE (CSINT)
    5. Switch Settings
    Standard settings of switches on this circuit card are shown in the table below.
    SWITCH NAMESWITCH 
    NUMBERSWITCH 
    SETTINGSTANDARD 
    SETTINGMEANING
    MB
     (Toggle Switch)
    UpCircuit card make-busy set
    Down
    Circuit card make-busy cancel
    MBR
     (Piano-Key Switch)
    0ON Line 0 make-busy request
    OFF×Line 0 make-busy request cancel
    1ON Line 1 make-busy request
    OFF×Line 1 make-busy request cancel
    2ON Line 2 make-busy request
    OFF×Line 2 make-busy request cancel
    3ON Line 3 make-busy request
    OFF×Line 3 make-busy request cancel
    MODE 
    (Rotary Switch)
    0×Fixed
    1~FNot used
    SW10 
    (DIP Switch)
    1ONMounted in WCS
    OFF×Mounted in PCS
    2ON×Fixed
    3ON×Fixed
    4ON×Fixed
    ON (MB)
    OFF
    No. 3
    No. 2
    No. 1
    No. 0OFF
    ON
    ON
    1234 
    						
    							ND-70290 (E) CHAPTER 3
    Page 69
    Revision 3.0
    PA-4CSIE (CSINT)
    SWITCH NAMESWITCH 
    NUMBERSWITCH 
    SETTINGSTANDARD 
    SETTINGMEANING
    SW11 
    1PAD on TSW side
    2
    3ON×Not used
    4ON×Not used
    5PB Sender Mode (Law/Level) Selection  
    Note:µ/A-law can be selected on the TSW side PAD. 
    µ-law Standard = High : -7.0 dBm 
    Low : -9.0 dBm
    A-law Standard =High : -8.0 dBm 
    Low : -10.0 dBm 6
    7ON×Fixed
    8ON×Fixed
    (DIP Switch)
    ON
    12
    3456
    78SWITCH 1 SWITCH 2 PAD
    OFF OFF Not used
    ON OFF A-Law
    OFF ON µ (PS)-A (TSW) Conversion
    ON ON µ-Law (Standard Setting)
    SWITCH 5 SWITCH 6 LAW/LEVEL
    OFF OFFNot used
    ON OFF
    OFF ON
    ON ONµ-law Standard
    A-law Standard 
    Note 
    						
    							CHAPTER 3 ND-70290 (E)
    Pag e 7 0
    Revision 3.0
    PA-4CSIE (CSINT)
    Note:
    The following diagram shows the PAD control method.
    SWITCH NAMESWITCH 
    NUMBERSWITCH 
    SETTINGSTANDARD 
    SETTINGMEANING
    SW12
    (DIP Switch)
    1~8
    ON
    12
    345678
    Connection with C.O.  Note 
    Connection with a station.  Note 
    SWITCH 1 SWITCH 2 SWITCH 3 PAD VALUE
    OFF OFF OFF Not used
    ON OFF OFF Not used
    OFF ON OFF PAD 1=3 dB
    ON ON OFF PAD 1=0 dB
    OFF OFF ON PAD 1=–3 dB
    ON OFF ON PAD 1=–5 dB
    (Standard setting)
    OFF ON ON PAD 1=–7 dB
    ON ON ON PAD 1=–10 dB
    SWITCH 4 PAD VALUE
    ON PAD 2=3 dB (Standard setting)
    OFF PAD 2=0 dB
    SWITCH 5 SWITCH 6 SWITCH 7 PAD VALUE
    OFF OFF OFF Not used
    ON OFF OFF PAD 1=5 dB
    OFF ON OFF PAD 1=3 dB
    ON ON OFF PAD 1=0 dB
    (Standard setting)
    OFF OFF ON PAD 1=–3 dB
    ON OFF ON PAD 1=–5 dB
    OFF ON ON PAD 1=–7 dB
    ON ON ON PAD 1=–10 dB
    SWITCH 8 PAD VALUE
    ON PAD 2=3 dB
    OFF PAD 2=0 dB (Standard setting)
    PAD 1
    PAD 2 TSW Side
    Line Side 
    						
    							ND-70290 (E) CHAPTER 3
    Page 71
    Revision 3.0
    PA-4CSIE (CSINT)
    PA-4CSIE (CSINT) : ZT (Zone Transceiver) Interface
    MODULE
    NAMESLOTSWITCH 
    NAMESWITCH SHAPE REMARKS
    PIM MB ON : Make-busy set of circuit 
    card 
    OFF : Make-busy cancel of 
    circuit card
    MBR
    MODE
    SW10
    SW11
    SW12
    ON (MB)
    OFF
    No. 3
    No. 2
    No. 1
    No. 0OFF
    ON
    ON
    1234
    ON
    12
    3456 78
    ON
    12
    3
    456 78 
    						
    							CHAPTER 3 ND-70290 (E)
    Pag e 7 2
    Revision 3.0
    PA-4CSIE (CSINT)
    6. External interface
    Below are accommodation of the LT connector leads of this circuit card and connecting route diagram.
    a. LT Connector Lead Accommodation when this circuit card is mounted in PIM.
    Figure 3-11  LT Connector Leads Accommodation of PIM : PA-4CSIE
    26272829303132333435363738394041
    1234567891011121314151642434445464748
    1718192021222349502425
    Accommodated in *1
    LT0, 2, 4, 6, 8, 10 Connector
    LT Connector Accommodation
    26272829303132333435363738394041
    1234567891011121314151642434445464748
    1718192021222349502425
    Accommodated in *2
    LT1, 3, 5, 7, 9,11 Connector
    26272829303132333435363738394041
    1234567891011121314151642434445464748
    1718192021222349502425
    Accommodated in *3
    LT1, 3, 5, 7, 9, 11 Connector
    RB0
    232221201918171615141312111009080706050403020100
    LT6 LT7 LT8 LT9 LT10 LT11LT0 LT1 LT2 LT3 LT4 LT5
    23 19 15
    22 18 14
    21 17 13
    20 16 1223 19 15
    22 18 14
    21 17 13
    20 16 12 11 09 07 05 03 01
    10 08 06 04 02 00 11 09 07 05 03 01
    10 08 06 04 02 00
    Group No.
    Slot No.
    LT Connector Name
    PIM
    32
    **
    Highway Block
    01324567981011 2*
    1*
    1*
    2*
    3*
    1*
    3*
    1*
    3*
    1*
    3*
    2*
    1*
    3*
    2* TB0
    RB1
    TB1
    RB2
    TB2
    RB3
    TB3RA0
    TA0
    RA1
    TA1
    RA2
    TA2
    RA3
    TA3RB0
    TB0
    RB1
    TB1
    RB2
    TB2
    RB3
    TB3RA0
    TA0
    RA1
    TA1
    RA2
    TA2
    RA3
    TA3
    RB0
    TB0
    RB1
    TB1
    RB2
    TB2
    RB3
    TB3RA0
    TA0
    RA1
    TA1
    RA2
    TA2
    RA3
    TA3
    2* 
    						
    							ND-70290 (E) CHAPTER 3
    Page 73
    Revision 3.0
    PA-4CSIE (CSINT)
    Figure 3-12  Connecting Route Diagram
    PBX
    CSINT
    TA
    TB
    RA
    RBRA
    RB
    TA
    TB
    ZT IN
    OUT MDF 
    						
    All NEC manuals Comments (0)

    Related Manuals for NEC Neax 2400 Imx Wireless System Manual