NEC Neax 2400 Imx Wireless System Manual
Have a look at the manual NEC Neax 2400 Imx Wireless System Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
TABLE OF CONTENTS ND-70290 (E) Pag e iv Revision 3.0 This page is for your notes.
ND-70290 (E) LIST OF FIGURES Page v Revision 3.0 LIST OF FIGURES Figure TitlePage Figure 1-1 Route Connecting Diagram : Built-in PCS System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Figure 1-2 Comparison : Standalone Type and Fusion Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Figure 1-3 Power Supply from the Built-in PCS System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Figure 1-4 Local Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Figure 1-5 Route Connection Diagram : U Interface (When NT1 is used) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Figure 2-1 Related Equipment for Built-in PCS System (When using PA-4CSIC) . . . . . . . . . . . . . . . . . . . . . . 24 Figure 2-2 Related Equipment for Built-in PCS System (When using PA-4CSIE) . . . . . . . . . . . . . . . . . . . . . . . 26 Figure 2-3 Standard Installation Image . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Figure 2-4 High Traffic Installation Image . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Figure 2-5 Image of ZT Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Figure 2-6 Example of Inappropriate Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 Figure 2-7 Dimension Drawing for ZT Installation (1/2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Figure 2-8 Dimension Drawing for ZT Installation (2/2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Figure 2-9 Mounting of the ZT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Figure 2-10 Local Power Feeding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Figure 2-11 LEDs on the Zone Transceiver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 Figure 2-12 Adjustment of Antenna . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 Figure 3-1 Location of Card in System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 Figure 3-2 Lamp, Key and Connectors : PA-4CSIC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 Figure 3-3 LT Connector Leads Accommodation of PIM : PA-4CSIC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 Figure 3-4 Connecting Route Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 Figure 3-5 Location of Card in System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 Figure 3-6 Lamp, Key and Connectors : PA-4CSID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 Figure 3-7 LT Connector Leads Accommodation of PIM : PA-4CSID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 Figure 3-8 Connecting Route Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 Figure 3-9 Location of Card in System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 Figure 3-10 Lamp, Key and Connectors : PA-4CSIE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 Figure 3-11 LT Connector Leads Accommodation of PIM : PA-4CSIE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72 Figure 3-12 Connecting Route Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 Figure 3-13 Location of Card in System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74 Figure 3-14 Lamp, Key and Connectors : PA-4CSIF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75 Figure 3-15 LT Connector Leads Accommodation of PIM : PA-4CSIF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82 Figure 3-16 Connecting Route Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83 Figure 3-17 Location of PA-CK16 [SYNC (WCS)] Card in the System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .84 Figure 3-18 Face Layout of PA-CK16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85 Figure 3-19 LT Connector Lead Accommodation (1/2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88 Figure 3-19 LT Connector Lead Accommodation (2/2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89 Figure 3-20 Connecting Route Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90 Figure 3-21 Example of Clock Network Using PA-CK16 [SYNC (WCS)] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91 Figure 4-1 PS Roaming in Release 8 Enhancement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126 Figure 4-2 ATRK for 24PRT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150 Figure 4-3 ATRK for 24DTI + 2DCH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151 Figure 4-4 ATRK for 30PRT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152 Figure 4-5 ATRK for 30DTI + 2DCH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 153 Figure 4-6 Data Communications via Networking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 165 Figure 4-7 Group Call-Automatic Conference using Station Hunting-Circular . . . . . . . . . . . . . . . . . . . . . . . . . 177 Figure 4-8 Outline of Short Text Message (STM) Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 185 Figure 5-1 Command Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 189 Figure 6-1 Make-Busy Set of CSINT Circuit Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 313 Figure 6-2 Make-Busy Cancel of CSINT Circuit Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 313
LIST OF FIGURES ND-70290 (E) Pag e v i Revision 3.0 LIST OF FIGURES Figure TitlePage Figure 6-3 Make-Busy Set of ZT and Each B Channel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 314 Figure 6-4 Make-Busy Cancel of ZT and Each B Channel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 314
LIST OF TABLES Ta b l e T i t l ePage ND-70290 (E) LIST OF TABLES Pag e vii Revision 3.0 Table 1-1 System Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Table 1-2 List of PCS Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Table 1-3 List of OG Call Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Table 1-4 List of IC Call Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Table 1-5 List of Station Service Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Table 1-6 List of Other Service Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Table 1-7 List of Attendant Console Service Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Table 1-8 List of Network Service Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Table 1-9 List of Operation/Maintenance Service Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Table 1-10 List of ISDN Service Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Table 1-11 List of CCIS Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Table 2-1 Meaning of LED Indications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 Table 3-1 Switch Setting Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 Table 3-2 PA-CK16 Lamp Indications Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86 Table 3-3 Standard Switch Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87 Table 4-1 Roaming Class Data List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 130 Table 4-1 Roaming Class Data List (Continued) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 131 Table 4-2 List of OG Call Features for Q.931a . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134 Table 4-3 List of IC Call Features for Q.931a. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134 Table 4-4 List of Station Service Features for Q.931a . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 136 Table 4-5 List of Other Service Features for Q.931a . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140 Table 4-6 List of Attendant Console Service Features for Q.931a . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141 Table 4-7 List of Network Service Features for Q.931a . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143 Table 4-8 List of Operation/Maintenance Service Features for Q.931a . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143 Table 4-9 List of ISDN Service Features for Q.931a . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144 Table 4-10 List of CCIS Service Features for Q.931a . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145 Table 4-11 Route Class Data Assignment Table for Q.931a . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149 Table 5-1 List of Commands. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 187 Table 5-2 SFI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 242
LIST OF TABLES ND-70290 (E) Pag e v iii Revision 3.0 This page is for your notes.
ND-70290 (E) PREFACE Page ix Revision 3.0 PREFACE This manual explains the necessary hardware (such as circuit cards, terminal), the data programming, service features, etc. for the Built-in PCS (Personal Communication System) System. Since this manual describes the only specific information for the Built-in PCS System, see the existing manuals for the installation, functions, service features and the system operation/maintenance job of the PBX itself.
PREFACE ND-70290 (E) Pag e x Revision 3.0 This page is for your notes.
ND-70290 (E) CHAPTER 1 Page 1 Revision 3.0 CHAPTER 1 GENERAL DESCRIPTION 1. GENERAL DESCRIPTION OF SYSTEM The Built-in PCS System has its CSINT, which interfaces the ZT with the system, mounted in the Port Interface Module (PIM). The Control Processor Rack (CPR) exclusively designed for the PCS is necessary in the PBX. Figure 1-1 shows the entire route connecting diagram of this system. Module structures of the Built-in PCS System are identical to that of the PBX. For more details, see the “Installation Design Manual”. Figure 1-1 Route Connecting Diagram : Built-in PCS System Note 1: A maximum of four (4) ZTs can be connected to one CSINT circuit card. Note 2:If the receive tone level of the PS is low, please select -5 dB (GAIN) in the PAD data of the COT Route by the command ARTD. ZT ZT ZT ZT PRT ODT PBX PS PS Analog TEL MATISDN CCTCCIS PSTN CSINT ELC ELC LC CFT IOCACIS COT/DTI D term (Note 1) ( Note 2)
CHAPTER 1 ND-70290 (E) Pag e 2 Revision 3.0 GENERAL DESCRIPTION Figure 1-2 Comparison : Standalone Type and Fusion Type Wired Terminal Standalone Type Wired Terminal Built-in PCS System Wireless Terminal Wireless Terminal Wired TerminalWireless Terminal NEAX2400 IMX FCCS (Fusion Link) Fusion Type NEAX2400 IMX PS ZT PSZT ZT ZT PS PS
ND-70290 (E) CHAPTER 1 Page 3 Revision 3.0 GENERAL DESCRIPTION 2. CONNECTION BETWEEN CSINT AND ZT Figures 1-3 through 1-5 illustrate connection methods between the CSINT and the ZT. The CSINT and the ZTs can be connected with two pairs of twisted cable using the following two connection methods - one, line voltage from the Built-in PCS System and the other, the local power supply. 1. PBX line power from Built-in PCS System. Line Power from the PCS System is power to the ZT supplied from the PBX. Figure 1-3 Power Supply from the Built-in PCS System 2. Local Power Supply Local power for the ZT is supplied via AC-DC adapter from the AC. Figure 1-4 Local Power Supply 3. U Interface (NT1 is used) Figure 1-5 Route Connection Diagram : U Interface (When NT1 is used) S interface PBX CSINT (PA- 4CSICZT /PA-4CSIE) S interface PBXCSINT(PA-4CSICZT /PA- 4CSIE) ZT NT1 U InterfaceCSINT(PA-4CSID PBX S Interface /PA-4CSIF)