NEC Neax 2400 Imx Wireless System Manual
Have a look at the manual NEC Neax 2400 Imx Wireless System Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
CHAPTER 5 ND-70290 (E) Pag e 3 04 Revision 3.0 DPSN PSNO.: PS Number CPCNT: Call Pickup Group Station Count CP STN 0-n: Call Pickup Group Station Number LNFLG: LDM/NDM 0: Input STN is DM 1: Input STN is PS TELN (LDM) 2: Input STN is PS TELN (NDM) MID EN: Middle EN FPC NO.: Fusion Point Code for Node Number Log Index: Logical Index MASTER TN: Master Tenant Number MASTER STN: Master Station Number MASTER LENS: Master Equipment Number MASTER TN: Master Tenant Number MASTER TEC: Master Telephone Equipment Number MASTER RSC: Master Route Restriction Class MASTER SFC: Master Service Feature Class SHP: Hunting Group-Pilot Data 0: Out of Service 1: In Service SHC: Hunting Group-Circular Data 0: Out of Service 1: In Service SHU: Hunting Group-UCD Data 0: Out of Service 1: In Service
ND-70290 (E) CHAPTER 5 Page 305 Revision 3.0 DRPS DRPS : Display for Reverse Develop PS Data 1. GENERAL This command is used to read/display the PS operation data from a PS number or PS-ID. 2. PRECAUTIONS None 3. DATA ENTRY INSTRUCTION IKIND (INPUT KIND) Note : 1 = Individual PS number (5 digits or less) 2 = PS-ID (1–268435455) 3 = PS number (12 digits or less: Decimal) 4 = PS number (13 digits or less: Decimal) 5 = PS number (13 digits or less: Hexadecimal) IPSNO Note : PS Number Note:Reading process is executed by clicking the “Read” button, after finishing these parameters’ data entry.
CHAPTER 5 ND-70290 (E) Pag e 3 06 Revision 3.0 DTFP DTFP : Display of CS/ZT Peg Count Data 1. GENERAL This command is used for displaying the result of traffic measurement data for “Type”=17 (CS Peg Count) assigned by the ATRF command. 2. PARAMETERS Traffic Data 1 : Terminal Traffic-DTF101 Route Traffic-DTF102 Station Peg Count-DTF103 Attendant Peg Count-DTF104 Route Peg Count-DTF105 Traffic Data 2 : Service Peg Count-DTF201 Traffic Data 3 : UCD Route Peg Count-DTF301 UCD Group Peg Count-DTF302 UCD Station Peg Count-DTF303 Traffic Data 5 : Attendant Ans. Peg Count-DTF501 CS/ZT Peg Count-DTFP System In All Each PCN Number Each Call Area Number Specify Each Number Traffic Data 6 : Connection Route Peg Count-DTF601 : Connection Route Traffic-DTF602
ND-70290 (E) CHAPTER 5 Page 307 Revision 3.0 DPSN DPSN : Display of PS Station Data 1. GENERAL This command is used to display the PS station data. The display appears when the Tenant Number and Physical Station/Telephone Number are entered. This command can also be used to display information on Hot Line station, details on PS data and Call Pickup Group data. 2. PRECAUTIONS None 3. PARAMETERS a. Parameters on PS Station Number TN/UGN: Tenant Number/User Group Number STN/PS TELN: Station Number/PS Telephone Number ETN: Effective Tenant Number LENS: Equipment Number TEC: Telephone Equipment Class RSC: Route Restriction Class SFC: Service Feature Class b. Parameters on Related Data PH: Phantom Kind 0: PHSTN Data is ALL 0. (PHSTN is Not Registered) 1: PHSTN Data is Individual Phantom Number. 2: PHSTN Data is Group Phantom Number. PHSTN 0-4: Phantom Station Number CPGF: Call Pickup Flag 0: Not Belong in Call Pickup Group 1 or 2:Belong in Call Pickup Group HTI: Hot Line Index 0: Hot Line Data is Nothing 1: Connection for Station HOT CON TN: Hot Line Connective Tenant Number HOT CON STN: Hot Line Connective Station Number 2: Connection for External Line HOT ADC: Hot Line Connective Speed Calling Abbreviated Digit 4: Connection for Trunk HOT CON RT: Hot Line Connective Route Number HOT CON TK: Hot Line Connective Trunk Number PS-ID: PS-ID IND-PS: Individual PS Number PS STN: PS Station Number PSNO. TYPE: PS Number Type PSNO.: PS Number CPCNT: Call Pickup Group Station Count CP STN 0-n: Call Pickup Group Station Number
CHAPTER 5 ND-70290 (E) Pag e 3 08 Revision 3.0 DPSN LNFLG: LDM/NDM 0: Input STN is DM 1: Input STN is PS TELN (LDM) 2: Input STN is PS TELN (NDM) MID EN: Middle EN FPC NO.: Fusion Point Code for Node Number Log Index: Logical Index MASTER TN: Master Tenant Number MASTER STN: Master Station Number MASTER LENS: Master Equipment Number MASTER TN: Master Tenant Number MASTER TEC: Master Telephone Equipment Number MASTER RSC: Master Route Restriction Class MASTER SFC: Master Service Feature Class
ND-70290 (E) CHAPTER 5 Page 309 Revision 3.0 DTFP DTFP : Display of CS/ZT Peg Count Data 1. GENERAL This command is used for displaying the result of traffic measurement data for “Type”=17 (CS Peg Count) assigned by the ATRF command. 2. PARAMETERS Traffic Data 1 : Terminal Traffic-DTF101 Route Traffic-DTF102 Station Peg Count-DTF103 Attendant Peg Count-DTF104 Route Peg Count-DTF105 Traffic Data 2 : Service Peg Count-DTF201 Traffic Data 3 : UCD Route Peg Count-DTF301 UCD Group Peg Count-DTF302 UCD Station Peg Count-DTF303 Traffic Data 5 : Attendant Ans. Peg Count-DTF501 CS/ZT Peg Count-DTFP System In All Each Pcn Number Each Call Area Number Specify Each Number Traffic Data 6 : Connection Route Peg Count-DTF601 : Connection Route Traffic-DTF602
CHAPTER 5 ND-70290 (E) Pag e 3 10 Revision 3.0 MBCSL MBCSL : Make Busy of CS/ZT for Local Data Memory 1. GENERAL This command is used to assign and delete IDLE/BUSY status of B/D channel of the CS/ZT. 2. PRECAUTIONS This command is used for the Local Node. 3. PARAMETERS PCN (PHS COMMUNITY NUMBER) : 1-1024 ERN (CALLING AREA NUMBER) : 1-32 GRN (GROUP NUMBER) : 1-8 CSN (CS/ZT NUMBER) : 1-32 APCH (APPOINTMENT CHANNEL) : CS/ZT B2 B3 B4 Make-busy cancel/set between CS/ZT and CS/ZT Make-busy cancel/set of B2 channel Make-busy cancel/set of B3 channel Make-busy cancel/set of B4 channel LENS (EQUIPMENT NUMBER) : LINE EQUIPMENT NUMBER (Only Display) MB (MAKE BUSY/IDLE DATA) : 0/1 Idle/Busy FLT (NG CAUSE) : NG Cause (Only Display) 4. ENTRY PROCEDURE 1. Assignment Procedure a. PCN (PHS COMMUNITY NUMBER) : 1-1024 b. ERN (CALLING AREA NUMBER) : 1-32 c. GRN (GROUP NUMBER) : 1-8 d. CSN (CS/ZT NUMBER) : 1-32 e. APCH (APPOINTMENT CHANNEL) : CS/ZT B2 B3 B4 (Entering data can be selected) f. MB (MAKE BUSY/IDLE DATA) : 1 Busy
ND-70290 (E) CHAPTER 5 Page 311 Revision 3.0 MBCSN MBCSN : Make Busy of CS/ZT for Network Data Memory 1. GENERAL This command is used to assign and delete IDLE/BUSY status of B/D channel of the CS/ZT. 2. PRECAUTIONS This command is used for the Network Control Node. 3. PARAMETERS PCN (PHS COMMUNITY NUMBER) : 1-1024 ERN (CALLING AREA NUMBER) : 1-32 GRN (GROUP NUMBER) : 1-8 CSN (CS/ZT NUMBER) : 1-32 APCH (APPOINTMENT CHANNEL) : CS/ZT B2 B3 B4 Make-busy cancel/set between CS/ZT and CS/ZT Make-busy cancel/set of B2 channel Make-busy cancel/set of B3 channel Make-busy cancel/set of B4 channel LENS (EQUIPMENT NUMBER) : LINE EQUIPMENT NUMBER (Only Display) MB (MAKE BUSY/IDLE DATA) : 0/1 Idle/Busy FLT (NG CAUSE) : NG Cause (Only Display) 4. ENTRY PROCEDURE 1. Assignment Procedure a. PCN (PHS COMMUNITY NUMBER) : 1-1024 b. ERN (CALLING AREA NUMBER) : 1-32 c. GRN (GROUP NUMBER) : 1-8 d. CSN (CS/ZT NUMBER) : 1-32 e. APCH (APPOINTMENT CHANNEL) : CS/ZT B2 B3 B4 (Entering data can be selected) f. MB (MAKE BUSY/IDLE DATA) : 1 Busy
CHAPTER 5 ND-70290 (E) Pag e 3 12 Revision 3.0 This page is for your notes.
ND-70290 (E) CHAPTER 6 Page 313 Revision 3.0 CHAPTER 6 SYSTEM OPERATION AND MAINTENANCE 1. CSINT CIRCUIT CARD MAKE-BUSY SET/CANCEL 1. Make-Busy Set and Cancel of CSINT Circuit Card Explained below are methods to set the CSINT circuit card in a state of make-busy and cancel the busy state. Make-Busy Set Figure 6-1 Make-Busy Set of CSINT Circuit Card Make-Busy Cancel Figure 6-2 Make-Busy Cancel of CSINT Circuit Card ATTENTION Contents Static Sensitive Handling Precautions Required START MAKE-BUSY SET If the make-busy set of line is required, use the command MBCSL or the MB Switch (Piano Switch) in accordance with the designated port on the corresponding circuit card. If the make-busy set of the circuit card is required, use the MB Switch (Toggle Switch) of the corresponding circuit card. END MAKE-BUSY CANCEL If the make-busy cancel of line is required, use the command MBCSL or the MB Switch (Piano Switch) in accordance with the designated port on the corresponding circuit card. If the make-busy cancel of the circuit card is required, use the MB Switch (Toggle Switch) of the corresponding circuit card. START END