Home > NEC > Communications System > NEC Neax 2400 Imx Wireless System Manual

NEC Neax 2400 Imx Wireless System Manual

    Download as PDF Print this page Share this page

    Have a look at the manual NEC Neax 2400 Imx Wireless System Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							CHAPTER 5 ND-70290 (E)
    Pag e 2 44
    Revision 3.0
    ASPA
    ASPA  : Assignment of Special Access Code
    1. GENERAL
    This command is used to determined the kind of service and its Access Code to be executed.
    List Up Command: LSPA
    2. PRECAUTIONS
    This part describes only the content of the command added in the PCS system. For more details, refer to the
    “Office Data Specification”. 
    						
    							ND-70290 (E) CHAPTER 5
    Page 245
    Revision 3.0
    ASPA
    3. DATA ENTRY INSTRUCTIONS
    Access code (Max. 6 digits)
    TENANT
    NUMBER
    ( TN )ACCESS CODE
    ( ACC )
    MAX. 6 DIGITSCONNECTION STATUS
    ACC
    CI
    N = Normal service
    H = Hooking service
    B = Busy service
    INDEX
    ( CI )KIND OF
    SERVICE ( SRV )
    SRV
    STN = Station
    SSCA = Service code appendix
    OGCA = Outgoing call with route advance
    LCR = Least cost routingSSC = Service code 
    OGC= Outgoing call 
    UNIF = Office termination
    ANNC = Announcement service-single announcement 
    ANNCM = Announcement service-multiple announcement 
    PAGA = Paging answer LCRS= Register sender LCR
    PAGC = Paging cancel 
    						
    							CHAPTER 5 ND-70290 (E)
    Pag e 2 46
    Revision 3.0
    ASPA
    When SRV = SSCA (Service code appendix) is assigned; 
    NND appears when SIDA=97 (Call Hold Conference).
    The number of digits for an access code should be assigned in NND. NND
    SERVICE INDEX  A ( SIDA ) 1 - 255 NECESSARY DIGIT ( NND ) 1 - 6
    1-100Note
    101
    102C.F-PS Incoming Incomplete: Set
    C.F-PS Incoming Incomplete: Cancel
    103~107
    Note
    SIDA
    SIDA Service Name
    108
    109
    110~113
    114
    115
    116~255Number Sharing : Set
    Number Sharing : Cancel
    Call Forwarding-Dropped Calls : Set
    Call Forwarding-Dropped Calls : Cancel
    Note Note
    Note:  See the “Office Data Specification” regarding this data. 
    						
    							ND-70290 (E) CHAPTER 5
    Page 247
    Revision 3.0
    ASPA
    4. DATA SHEET
     SRV=SSCA Service code Appendix
    Note:Refer to the “Office Data Specification” regarding this data.
    TENANT
    NUMBER
    (TN)ACCESS CODE
    (ACC)
    MAXIMUM
    6 DIGITSCONNECTION
    STATUS 
    INDEX
    (CI) N/H/BKIND OF
    SERVICE
    (SRV)SERVICE
    FEATURE
    INDEX
    (SIDA)
    1 - 255NUMBER
    OF NEC-
    ESSARY
    DIGITS 
    (NND)SERVICE CONTENTS
    1
    100
    Note 
    NNormal
    SSCA 101Call Forwarding Incoming 
    Incomplete Set H Hooking
    BBusy
    NNormal
    SSCA 102
    Incoming Incomplete Cancel
    H Hooking
    BBusy
    103
    107
    Note 
    NNormal SSCA 108Number Sharing; Set
    NNormal SSCA 109
    Number Sharing; Cancel
    110
    113
    Note 
    NNormal SSCA 114Call Forwarding-Dropped 
    Calls ; Set
    NNormal SSCA 115
    Call Forwarding-Dropped 
    Calls ; Cancel
    116
    255
    Note 
    ~
    ~
    ~
    ~ 
    						
    							CHAPTER 5 ND-70290 (E)
    Pag e 2 48
    Revision 3.0
    ASYD
    ASYD  : Assignment of System Data
    1. GENERAL
    The ASYD/ASYDL command is used to assign the system data of the following node;
    Local Node (LN) / Network Control Node (NCN) of the Fusion network.
    Stand alone PBX.
    List Up Command: LSYD
    2. PRECAUTIONS
    This part describes only the contents of the command added in Built-in PCS system. For more details, refer to
    the “Office Data Specification.” 
    						
    							ND-70290 (E) CHAPTER 5
    Page 249
    Revision 3.0
    ASYD
    3. DATA ENTRY INSTRUCTIONS
    Define each bit corresponding
    data with referring to the
    SYSTEM DATA CONTENTS
    SYSTEM
    DATA
    TYPE
    ( SYS )DATA
    ( DATA )
    00-FF
    ( Hex ) SYSTEM
    DATA
    INDEX
    ( INDEX )
    0 - 511
    BIT CORRE-
    SPONDING
    DATA
    DATA
    0 / 1BITSYSTEM DATA CONTENTS
    DATA
    DATA BIT
    BIT
    DATA
    Hex 1
    1b0
    b1
    b2
    b3
    b4
    b5
    b6
    b7 1
    0
    0
    0
    0
    0
    0n
    n+1 FF031
    1
    0
    0
    0
    0
    0
    0b0
    b1
    b2 Not used
    Not used
    Not used
    Not used
    Not used
    Not used
    Number of zzz b3
    b4
    b5
    b6
    b7xxx service 0/1=Not to be provided/  To be provided
    yyy service 0/1=Not to be provided/  To be provided
    Convert from Binary DATA
    to Hexadecimal, and enter the
    Hex. value at DATA text box.
    00000011 b7 b6 b5 b4 b3 b2 b1 b0
    03 
    						
    							CHAPTER 5 ND-70290 (E)
    Pag e 2 50
    Revision 3.0
    ASYD
    SYSTEM
    DATA
    TYPE 
    (SYS)SYSTEM 
    DATA  
    INDEX 
    (INDEX)
    0 - 511DATA 
    (DATA) 
    00-FF 
    (Hex)BIT CORRE-
    SPONDING 
    DATA
    SYSTEM DATA CONTENTS
    DATA 
    0/1BIT
    15b
    0
    Access Code for C.F.-Busy Line and C.F. – Don’t Answer Services
    0/1 = Same/Separate
    Note 1:If a PCS system, C.F.-PS Incoming Call Incomplete also
    refers to this system data.
    Note 2:If “0” is assigned, assign either SID: 10 or 12 in
    command “ASPA”.
    b
    1Maximum number of Multiple Call Forwarding – All Calls/Busy 
    Line occurrences:
    Note:This data is valid when SYS-1, INDEX 69, bit 7 is assigned
    as “1”. b
    2
    b3
    b4Miscellaneous Timer Counter 
    (MTC)
    (0-7)Call Back – Delay Timer
    Timer Value Setting is MTC × 2 
    sec.
    When this data is “000”, Timer 
    value is 2 sec. b
    5
    b6
    b7Call Back – Delay Timer
    0/1 = Ineffective/Effective
    b3b2b1b3b2b1
    000: 100:
    001: 101:
    010: 110:
    011:111:
    once
    three times twice
    five times four times 
    						
    							ND-70290 (E) CHAPTER 5
    Page 251
    Revision 3.0
    ASYD
    4. SYSTEM DATA PROGRAMMING SHEET (1)
    S
    Y
    S
    1
    SYSTEM
    DATA
    INDEX
    0-511DATA
    00-FFB
    I
    TSYSTEM DATA CONTENTS
    30 060 Mounting Capacity of Data Memory (DM) : 1~63 Mbyte (01~3F) 
    Normally assigned as “6” 
    1
    2
    3
    4
    5
    6
    7
    4200Access code using Pre-set dialing
     (e.g.: Special Access Code + Station number)
    0/1 : Out/In service
    1By cancelling C.F.-PS INCOMING INCOMPLETE
    0 = C.F.-DROPPED CALL is also cancelled
    1 = C.F.-DROPPED CALL is not cancelled
    2Not used
    3
    4
    5
    6
    7
    b7 b6 b5 b4 b3 b2 b1 b0
    00
    Data
    b7 b6 b5 b4 b3 b2 b1 b0
    0000000
    Data 
    						
    							CHAPTER 5 ND-70290 (E)
    Pag e 2 52
    Revision 3.0
    ASYD
    S
    Y
    S
    1
    SYSTEM
    DATA
    INDEX
    0-511DATA
    00-FFB
    I
    TSYSTEM DATA CONTENTS
    4210 Miscellaneous Time Counter (MTC) is 
    to be assigned a value from 1 Hex to F 
    Hex.1) Announcement PS-Out of 
    Zone disconnection timer 
    (Release Guard timer)
    Timer value setting is as 
    follows: (TC) sec. × (MTC)
    When the data is assigned as 
    00, the default data is 30 sec. 1
    2
    3
    4 Timer class (TC)
    0 : –  3 : 2 sec.  6 : –
    1 : – 4 : – 7 : –
    2 : –  5 : – 5
    6
    7 Not used
    4220Miscellaneous Time Counter (MTC) is 
    to be assigned a value from 1 Hex to F 
    Hex.2) No-tone connection timer to 
    the called party during the 
    handover
    Timer value setting is as 
    follows: 800 msec.+ (TC) × 
    (MTC)
    When the data is assigned as 
    00, the default data is 800 
    msec. 1
    2
    3
    4Timer class (TC)
    0 : –  3 : –  6 : –
    1 : 64 msec. 4 : –  7 : –
    2 : –  5 : – 5
    6
    7Not used
    4230 Miscellaneous Time Counter (MTC) is 
    to be assigned a value from 1 Hex to F 
    Hex.3) ZT start-up Guard Timer 
    when initialization is in 
    progress.
    (This is the timer by which 
    the ZT is placed out of Zone 
    and made send PS location 
    registration.)
    Timer value setting is as 
    follows: (TC) sec.× (MTC)
    When the data is assigned as 
    00, the default data is 60 sec. 1
    2
    3
    4 Timer class (TC)
    0 : –  3 : 2 sec.  6 : –
    1 : – 4 : 30 sec. 7 : –
    2 : –  5 : – 5
    6
    7Not used
    b7 b6 b5 b4 b3 b2 b1 b0
    0
    b7 b6 b5 b4 b3 b2 b1 b0
    0
    b7 b6 b5 b4 b3 b2 b1 b0
    0 
    						
    							ND-70290 (E) CHAPTER 5
    Page 253
    Revision 3.0
    AAED
    AAED  : Assignment of Announcement Equipment Data
    1. GENERAL
    This command is used to assign the trunk information related to Announcement Equipment on a tenant basis. 
    List Up Command: LAED
    2. PRECAUTIONS
    This part describes only the contents of the command added in PCS system. For more details, refer to the “Office
    Data Specification”. 
    						
    All NEC manuals Comments (0)