CHAPTER 5 ND-70290 (E) Pag e 2 84 Revision 3.0 AZDL AZDL : ZT Program Download 1. GENERAL This command is used to download ZT program from “Program Master ZT” to “Program Download ZT”. 2. PRECAUTIONS 1. This feature is available for Series 7300 or later software. 2. For detailed information on ZT program Download service. 3. DATA ENTRY INSTRUCTIONS PROGRAM MASTER ZT PCN : PHS Community Number of rogram Master ZT: 1-1024 PROGRAM MASTER ZT CRN : Calling Area Number of Program Master ZT: 1-32 PROGRAM MASTER ZT GRN : Group Number of Program Master ZT: 1-8 PROGRAM MASTER ZT CSN/ZTN : ZT Number of Program Master ZT: 1-32 PROGRAM DOWNLOAD ZT PCN : PHS Community Number of Slave Program Download ZT: 1-1024 PROGRAM DOWNLOAD ZT CRN : Calling Area Number of Slave Program Download ZT: 1-32 PROGRAM DOWNLOAD ZT GRN : Group Number of Slave Program Download ZT: 1-8 PROGRAM DOWNLOAD ZT CSN/ZTN: ZT Number of Slave Program Download ZT: 1-32
ND-70290 (E) CHAPTER 5 Page 285 Revision 3.0 AZDL 4. DATA SHEET ZT Program Download Data Sheet PROGRAM MASTER ZT PCN 1-1024PROGRAM MASTER ZT CRN 1-32PROGRAM MASTER ZT GRN 1-8PROGRAM MASTER ZT CSN/ZTN 1-32PROGRAM DOWNLOAD ZT PCN 1-1024PROGRAM DOWNLOAD ZT CRN 1-32PROGRAM DOWNLOAD ZT GRN 1-8PROGRAM DOWNLOAD ZT CSN/ZTN 1-32
CHAPTER 5 ND-70290 (E) Pag e 2 86 Revision 3.0 AHLG AHLG : Assignment of CFT Hot Line Group 1. GENERAL This command is used to assign, delete and display the DM data which is concerned with PCS Calling Conference Group. List Up Command: LHLG 2. PRECAUTIONS 1. This command is available for Series 7400 or later software. 2. “Set” key and “Del” key can be used after TN and ACC are entered and then this data is read by pressing “Get” key. If this data is not programmed, press “Get” key again, PORT, TYPE, D_TN, D_STN and D_ADC can be assigned. 3. The input parameter depends on TYPE value. TYPE=0 or blank : Not displayed TYPE=1 : D_TN, D_STN TYPE=2 : D_ADC 4. Only Speed Calling Dial Number which is the same tenant as conference leader port can be entered. 5. The user must assign the data to all ports (PORT 0-7). 6. If all ports are TYPE=0, this assignment ends in failure. 7. Data writing is executed by pressing “Set” key. 3. DATA ENTRY INSTRUCTIONS TN (TENANT NUMBER) : 1- ACC (CFTB H/L ACCESS CODE) : 0-9, #, * (maximum 5 digits) PORT (PORT NUMBER) : 1-7 TYPE (KIND OF STN) : 0=Vacant Port 1=STN/PS 2=OUTSIDE TRUNK D_TN (TENANT NUMBER OF DESTINATION) : 1- D_STN (STATION NUMBER OF DESTINATION) : 0-9, #, * (maximum 5 digits) D_ADC (SPEED CALLING DIAL NUMBER OF DESTINATION): 0-9, #, * (maximum 4 digits)
ND-70290 (E) CHAPTER 5 Page 287 Revision 3.0 AHLG 4. DATA SHEET TENANT NUMBER (TN)STATION NUMBER OF CFTB H/L ACCESS CODE (ACC) Max. 5 digits PORTKIND OF STN (TYPE) 0~2TENANT NUMBER OF DESTINATION (D_TN)STATION NUMBER OF DESTINATION (D_STN) Max. 5 digitsSPEED CALLING DIAL NUMBER (D_ADC) Max. 4 digits 1 2 3 4 5 6 7 TENANT NUMBER (TN)STATION NUMBER OF CFTB H/L ACCESS CODE (ACC) Max. 5 digits PORTKIND OF STN (TYPE) 0~2TENANT NUMBER OF DESTINATION (D_TN)STATION NUMBER OF DESTINATION (D_STN) Max. 5 digitsSPEED CALLING DIAL NUMBER (D_ADC) Max. 4 digits 1 2 3 4 5 6 7 TENANT NUMBER (TN)STATION NUMBER OF CFTB H/L ACCESS CODE (ACC) Max. 5 digits PORTKIND OF STN (TYPE) 0~2TENANT NUMBER OF DESTINATION (D_TN)STATION NUMBER OF DESTINATION (D_STN) Max. 5 digitsSPEED CALLING DIAL NUMBER (D_ADC) Max. 4 digits 1 2 3 4 5 6 7
CHAPTER 5 ND-70290 (E) Pag e 2 88 Revision 3.0 AHLGL AHLGL : Assignment of CFT Hot Line Group for LDM 1. GENERAL This command is used to assign, delete and display the LDM data which is concerned with PCS Calling Conference Group. List Up Command: LHLGL 2. PRECAUTIONS 1. This command is available for Series 7400 or later software. 2. This command is used for the Local Node (LN). 3. “Set” key and “Del” key can be used after UGN and TELN are entered and then this data is read by pressing “Get key”. If this data is not programmed, press “Get” key again, DA, PORT, TYPE, D_UGN, D_TELN and D_ADC can be assigned. 4. The input parameter depends on TYPE value. TYPE=0 or blank : Not displayed TYPE=1 : D_UGN, D_TELN TYPE=2 : D_ADC 5. Only Speed Calling Dial Number which is the same tenant as conference leader port can be entered. 6. The user must assign the data to all ports (PORT 0-7). 7. If all ports are TYPE=0, this assignment ends in failure. 8. Data writing to LDM is executed by pressing “Set” key. 3. DATA ENTRY INSTRUCTIONS UGN (USER GROUP NUMBER) TELN (CFTB H/L ACCESS CODE : 0-9, #, * (maximum 16 digits) [TELEPHONE NUMBER]) DA : 0=Stop : 1=Continue alerting, when the STN does not answer. PORT (PORT NUMBER) : 1-7 TYPE (KIND OF STN) : 0=Vacant Port 1=STN/PS 2=OUTSIDE TRUNK (Not used) D_UGN (USER GROUP NUMBER OF DESTINATION) D_TELN (TELEPHONE NUMBER OF DESTINATION) : 0-9, #, * (maximum 16 digits) D_ADC (SPEED CALLING DIAL NUMBER OF DESTINATION): 0-9, #, * (maximum 4 digits) (Not used)
ND-70290 (E) CHAPTER 5 Page 289 Revision 3.0 AHLGL 4. DATA SHEET USER GROUP NUMBER (UGN)TELEPHONE NUMBER OF CFTB H/L ACCESS CODE (TELN) Max. 16 digitsRINGING STOP AFTER NO ANSWER TIMER (DA) 0/1 PORTKIND OF STN (TYPE) 0~2USER GROUP NUMBER OF DESTINATION (D_UGN)TELEPHONE NUMBER OF DESTINATION (D_TELN) Max. 16 digitsSPEED CALLING DIAL NUMBER (D_ADC) Max. 4 digits 1 2 3 4 5 6 7 USER GROUP NUMBER (UGN)TELEPHONE NUMBER OF CFTB H/L ACCESS CODE (TELN) Max. 16 digitsRINGING STOP AFTER NO ANSWER TIMER (DA) 0/1 PORTKIND OF STN (TYPE) 0~2USER GROUP NUMBER OF DESTINATION (D_UGN)TELEPHONE NUMBER OF DESTINATION (D_TELN) Max. 16 digitsSPEED CALLING DIAL NUMBER (D_ADC) Max. 4 digits 1 2 3 4 5 6 7 USER GROUP NUMBER (UGN)TELEPHONE NUMBER OF CFTB H/L ACCESS CODE (TELN) Max. 16 digitsRINGING STOP AFTER NO ANSWER TIMER (DA) 0/1 PORTKIND OF STN (TYPE) 0~2USER GROUP NUMBER OF DESTINATION (D_UGN)TELEPHONE NUMBER OF DESTINATION (D_TELN) Max. 16 digitsSPEED CALLING DIAL NUMBER (D_ADC) Max. 4 digits 1 2 3 4 5 6 7
CHAPTER 5 ND-70290 (E) Pag e 2 90 Revision 3.0 AHLGN AHLGN : Assignment of CFT Hot Line Group for NDM 1. GENERAL This command is used to assign, delete and display the NDM data which is concerned with PCS Calling Conference Group. List Up Command: LHLGL 2. PRECAUTIONS 1. This command is available for Series 7400 or later software. 2. This command is used for the Network Control Node (NCN). 3. “Set” key and “Del” key can be used after UGN and TELN are entered and then this data is read by pressing “Get key”. If this data is not programmed, press “Get” key again, DA, PORT, TYPE, D_UGN, D_TELN and D_ADC can be assigned. 4. The input parameter depends on TYPE value. TYPE=0 or blank : Not displayed TYPE=1 : UGN, TELN TYPE=2 : ADC (Only Speed Calling Dial Number of a node assigned conference leader port can be entered.) 5. Only Speed Calling Dial Number which is the same tenant as conference leader port can entered. 6. The user must assign the data to all ports (PORT 0-7). 7. If all ports are TYPE=0, this assignment ends in failure. 8. Data writing for NDM is executed by pressing “Set” key. 3. DATA ENTRY INSTRUCTIONS UGN (USER GROUP NUMBER) TELN (CFTB H/L ACCESS CODE : 0-9, #, * (maximum 16 digits) [TELEPHONE NUMBER]) DA : 0=Stop 1=Continue alerting, when the STN does not answer. PORT (PORT NUMBER) : 1-7 TYPE (KIND OF STN) 0=Vacant Port 1=STN/PS 2=OUTSIDE TRUNK (Not used) D_UGN (USER GROUP NUMBER OF DESTINATION) D_TELN (TELEPHONE NUMBER OF DESTINATION) : 0-9, #, * (maximum 16 digits) D_ADC (SPEED CALLING DIAL NUMBER OF DESTINATION) : 0-9, #, * (maximum 4 digits) (Not used)
ND-70290 (E) CHAPTER 5 Page 291 Revision 3.0 AHLGN 4. DATA SHEET USER GROUP NUMBER (UGN)TELEPHONE NUMBER OF CFTB H/L ACCESS CODE (TELN) Max. 16 digitsRINGING STOP AFTER NO ANSWER TIMER (DA) 0/1 PORTKIND OF STN (TYPE) 0~2USER GROUP NUMBER OF DESTINATION (D_UGN)TELEPHONE NUMBER OF DESTINATION (D_TELN) Max. 16 digitsSPEED CALLING DIAL NUMBER (D_ADC) Max. 4 digits 1 2 3 4 5 6 7 USER GROUP NUMBER (UGN)TELEPHONE NUMBER OF CFTB H/L ACCESS CODE (TELN) Max. 16 digitsRINGING STOP AFTER NO ANSWER TIMER (DA) 0/1 PORTKIND OF STN (TYPE) 0~2USER GROUP NUMBER OF DESTINATION (D_UGN)TELEPHONE NUMBER OF DESTINATION (D_TELN) Max. 16 digitsSPEED CALLING DIAL NUMBER (D_ADC) Max. 4 digits 1 2 3 4 5 6 7 USER GROUP NUMBER (UGN)TELEPHONE NUMBER OF CFTB H/L ACCESS CODE (TELN) Max. 16 digitsRINGING STOP AFTER NO ANSWER TIMER (DA) 0/1 PORTKIND OF STN (TYPE) 0~2USER GROUP NUMBER OF DESTINATION (D_UGN)TELEPHONE NUMBER OF DESTINATION (D_TELN) Max. 16 digitsSPEED CALLING DIAL NUMBER (D_ADC) Max. 4 digits 1 2 3 4 5 6 7
CHAPTER 5 ND-70290 (E) Pag e 2 92 Revision 3.0 COMMANDS 2. COMMANDS FOR OPERATION AND MAINTENANCE [Contents of Command Description] Each command is explained dividing into the following parts. Command Name Explained here are the command names to be entered via the keyboard and its full command names. General General functions of each command are explained. Precaution Cautions to be made when using each command are explained. Parameters Parameters (data) assigned by each command are shown. How to Use Usage of each command is explained. Related Commands Related commands are shown.
ND-70290 (E) CHAPTER 5 Page 293 Revision 3.0 AT R F ATRF : Assignment of Traffic Measurement Order 1. GENERAL This command is used to assign and delete traffic measurement programs. A request for traffic measurement is performed when a traffic measurement instruction has been assigned by this command. The collected traffic measurement data can be output from the MAT printer or stored on the HD of the MAT, which can be designated on the basis of traffic measurement type. 2. PRECAUTIONS None 3. PARAMETERS Input Data TYPE : Type of Traffic Measurement (1-16) Note:Refer to the “Operation & Maintenance Manual” for information about this data. PORT : Traffic Information Output Terminal Number (0-7) INTERVAL : Output interval (0-120) Interval must be assigned in 10 minute increments or 0 can be assigned which will require that an output time is assigned to “OUTPUT HOUR/ MINUTE”. START HOUR START MINUTE END HOUR END MINUTE OUTPUT HOUR :This data is valid only when “INTERVAL” = 0. OUTPUT MINUTE :This data is valid only when “INTERVAL” = 0. SRT : Start External Route Number ERT : End External Route Number DATA MEANING DATA MEANING 1~16Note 17 ZT peg count