CHAPTER 2 ND-70290 (E) Pag e 3 4 Revision 3.0 INSTALLATION DESIGN 4. Installation of the ZT (Zone Transceiver) Explained below is how to install the ZT and precautions to be made when mounting it. a. The ZT is a communication device that sends a weak signal as radio waves, it should not be installed near and around equipment or an environment listed below to ensure the speech quality and various kinds of control operations – care must be taken. [Indoor Installation] Do not install around equipment capable of emitting noise (high frequency electric waves) such as wireless apparatus, television set, radio set, fluorescent lightening, and microwave oven. [Outdoor Installation] Avoid places easily affected by radio disturbances from cars, etc. (e.g., near a principal road). When installing by the sea, protect the ZT from salt using the outdoor mounting box and other protection if necessary. Avoid places where there is a possibility to cause malfunction by radio waves. When installing by the sea, protect the ZT from salt using the outdoor mounting box and other protection if necessary. Besides, abnormal places with a fear of an explosion, subjected to malfunction by radio waves or to a strong electromagnetic field. b. Avoid installing on a clay wall or plasterboard. c. Ensure the wall or pillar to be used is strong enough to support the weight of the ZT, so that it does not shake, and has very little vibration. d. If a possible installation wall contains reinforcing steel, etc., keep the antenna away from the wall by slightly tilting it. e. When raising the antenna of the ZT, make sure that it does not touch the wall, etc.
ND-70290 (E) CHAPTER 2 Page 35 Revision 3.0 INSTALLATION DESIGN 2. INSTALLATION PROCEDURE OF ZONE TRANSCEIVER (ZT) STEP 1: When mounting a ZT on a wall/ceiling, observe the following instructions. i Do not mount a ZT on a wall/ceiling which cannot sustain the weight of ZT (e.g. a plaster wall, plywood wall). ii Make a sufficient space so that the antenna can be placed at any angle. iii When mounting a ZT on a wall which contains a reinforcing bar near the mounting location, place the antenna at an angle with the wall so as to make a space between the antenna and the reinforcing bar. Figure 2-6 Example of Inappropriate Mounting (i) (ii) (iii) plaster wall Reinforcing Bar
CHAPTER 2 ND-70290 (E) Pag e 3 6 Revision 3.0 INSTALLATION DESIGN STEP 2: Post the attached dimension drawing on the mounting location so as to mark the locations of screw holes. As shown Figure 2-7, two screw holes are provided as the lower mounting position. Depending on the mounting location, select either of the two mounting position. Figure 2-7 Dimension Drawing for ZT Installation (1/2) STEP 3: Secure the furnished screws to the marked locations. In this instance, for the lower mounting screw hole select either of mounting options depending on the mounting location. Leave a space [more than 4.3 in (110 (mm)] for the antenna. 4.2 (107) Screw of the mounting tag Screw of ZT 4.9 ( 124.4) Mounting tag ZT 1.6 (40 ) 6 .3 ( 160) 5.4 (138) 3.2 (80) 4.0 (100) inches (mm)
ND-70290 (E) CHAPTER 2 Page 37 Revision 3.0 INSTALLATION DESIGN Figure 2-8 Dimension Drawing for ZT Installation (2/2) 0.2 (5) 0.5 (12)2.4 (60) 0.08 (2) 0.3 (8) 0.2 (5) Front 0.9 (22.5) 4.9 (124.4) 2.2 (54) 0.5 (13.5) 0.4 (10) 3.1 (78.75) 0.8 (21) 0.08 (2) 0.3 (8) inches (mm)
CHAPTER 2 ND-70290 (E) Pag e 3 8 Revision 3.0 INSTALLATION DESIGN STEP 4: Mount the ZT on the wall and slide it so that the heads of screws may fix the ZT tightly. Figure 2-9 Mounting of the ZT STEP 5: If power feeding from the PCS is impossible, use the “AC adapter” for local power feeding. The “AC adapter” is connected to the ZT as shown below. Figure 2-10 Local Power Feeding Use either of two screwsWALL Screw Connector cover Rear Modular jack DC in jack
ND-70290 (E) CHAPTER 2 Page 39 Revision 3.0 INSTALLATION DESIGN STEP 6: Turn ON the power to the ZT to confirm the lamp indications are normal. Refer to Table 2-1 and Figure 2-11. * One cycle is 2 second Table 2-1 Meaning of LED Indications LAMP LIGHT STAGE MEANING POWER LIT Light when the power is supplied STATUS OFF Line is not open LIT The flicker cycle is 0.1 seconds.ZT does not stand by LIT The light cycle is 1.8 seconds.All ZT lines are busy. LIT The flicker cycle is 0.2 seconds by standard.The number of ZT line used. (The number of flicker indicates the number of ZT line used.) Lamp Time (0.2s) Lamp Time (0.2s) Lamp Time (0.2s) Lamp Time (0.2s) Lamp 1 line used. 2 lines used. 3 lines used. (All ZT lines are busy.)Time (0.2s)
CHAPTER 2 ND-70290 (E) Pag e 4 0 Revision 3.0 INSTALLATION DESIGN Figure 2-11 LEDs on the Zone Transceiver POWER STATUS Power lamp Status lamp
ND-70290 (E) CHAPTER 2 Page 41 Revision 3.0 INSTALLATION DESIGN STEP 7: The angle of the antenna is variable between 0º and 180º as shown below. In a wall-mount installation, normally the antenna is set at an angle of 0º so that the antenna may be vertical with the radio zone. Note:Since the antenna is easily broken, handle it with care. Figure 2-12 Adjustment of Antenna 90 90 90
CHAPTER 2 ND-70290 (E) Pag e 4 2 Revision 3.0 INSTALLATION DESIGN 3. SYSTEM START-UP After finishing the installation of the PBX (installation of the PBX, confirmation of the switch-setting of every circuit card and cable connection), start up the system. This diagram outlines the procedure to start up the system. For more details, refer to the “Installation Manual.” START Insulation test Heat-run Power on Program Install Program load Assignment of Office Data Office Data Back-up Confirmation of Lamp, display and System message Initialization END
ND-70290 (E) CHAPTER 3 Page 43 Revision 3.0 CHAPTER 3 CIRCUIT CARDS This chapter describes the circuit cards related to the Built-in PCS system. Refer to the “Circuit Card Manual” to check other circuit cards that are introduced here. PA-4CSIC (CSINT) : ZT (Zone Transceiver) Interface Note 1 PA-4CSID (CSINT) : ZT (Zone Transceiver) InterfaceNote 2 PA-4CSIE (CSINT) : ZT (Zone Transceiver) InterfaceNote 1 PA-4CSIF (CSINT) : ZT (Zone Transceiver) InterfaceNote 2 PA-CK16 (WCS) : Synchronous Signal Transmission Circuit for CS/ZT Note 1:For provision of ISDN S interface to ZT. Note 2:For provision of ISDN U interface to ZT.