Home > NEC > Communications System > NEC Neax 2400 Imx Wireless System Manual

NEC Neax 2400 Imx Wireless System Manual

    Download as PDF Print this page Share this page

    Have a look at the manual NEC Neax 2400 Imx Wireless System Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							CHAPTER 3 ND-70290 (E)
    Pag e 7 4
    Revision 3.0
    PA-4CSIF (CSINT)
    PA-4CSIF (CSINT)  : ZT (Zone Transceiver) Interface
    1. General Functions
    This card is a line circuit card which accommodates Zone Transceivers (ZTs) via the ISDN U interface. ZTs
    are to be connected using NT1.
    The main specifications and functions of this circuit card are shown below.
     A maximum of four ZTs can be accommodated in one circuit card.
     Interface with the NT1 is based on the standard ISDN interface. (U reference-point Echo Canceller
    method. ANSI TI.601, Q.921 interface)
     Two B channels of each 32 kbps can be used in 2B+D with the total speed of 64 kbps.
     Sealing current (Maximum 15 mA) can be supplied to protect cables from rusting.
     Equipped with ADPCM which enables the B-channel bit rate to change. (TSW-side: 64 kbps, ZT side:
    32 kbps)
    Figure 3-13  Location of Card in System
    2. Mounting Location of Circuit Card and Its Conditions
     Mounting location of circuit card: Universal slot of the PIM
    Conditions: 12 CSINT circuit cards can be mounted in one PIM
    ZT
    I.430PS
    PS
    TSW
    PLO PA-4CSIF
    ANSI TI.601
    NT1 
    						
    							ND-70290 (E) CHAPTER 3
    Page 75
    Revision 3.0
    PA-4CSIF (CSINT)
    3. Lamps, Switches, Connectors and Their Location
    The following diagram shows the location of Lamp, Key and Connectors.
    Figure 3-14  Lamp, Key and Connectors : PA-4CSIF
    OPE
    MB
    MODE
    SW21NOPE
    MBRL3
    L2
    L1
    L0
    SW12
    SW11
    SW20
    SW10LPB
    L3
    L2
    L1
    L0
    MONITOR (Not used)
    BL34
    BER3 BL33
    LYR3 BL32
    BL24
    BER2 BL23
    LYR2 BL22
    BL14
    BER1 BL13
    BL12
    LYR1
    BL04
    BER0 BL03
    BL02
    LYR0 
    						
    							CHAPTER 3 ND-70290 (E)
    Pag e 7 6
    Revision 3.0
    PA-4CSIF (CSINT)
    4. Lamp Indication
    Shown below are the contents of lamp indication on this circuit card.
    n=0~3
    Note 1:B2 through B4 channels represent channel names of 32K ADPCM.
    Note 2:Establishment of synchronization on U Reference Point may take 30 seconds or more.
    LAMP NAME COLOR MEANING
    OPE Green Remains lit when the card is operating normally.
    NOPE Red Remains lit when the card is in make-busy state.
    BLn4Green  Remains lit when B4 channel of the line #n is communicating  (
    Note).
    Flashing Flashes while the corresponding circuit is in make-busy state (60 IPM).
    Off Remains off while the corresponding circuit is idle.
    BLn3Green Remains lit when B3 channel of the line #n is communicating  (
    Note).
    Flashing Flashes while the corresponding circuit is in make-busy state (60 IPM).
    Off Remains off while the corresponding circuit is idle.
    BLn2Green Remains lit when B2 channel of line #n is communicating  (
    Note).
    Flashing Flashes while the corresponding circuit is in make-busy state (60 IPM).
    Off Remains off while the corresponding circuit is idle.
    LY R nGreen Remains lit when the layer 2 link of line #n is established.
    FlashingFlashes when synchronization is established on Layer 1 of S Reference Point 
    (60 IPM).
    Flashes when synchronization is established on Layer 1 of U Reference Point 
    (120 IPM).
    Off Synchronization is not established on both Layer 1 and Layer 2.
    BERnRedTwo or more CRC errors occur per second and the condition lasts for 10 
    seconds.
    Off One or no CRC error occurs per second. 
    						
    							ND-70290 (E) CHAPTER 3
    Page 77
    Revision 3.0
    PA-4CSIF (CSINT)
    5. Switch Settings
    Switches on this card have the following meanings.
    SWITCH NAMESWITCH 
    NUMBERSWITCH 
    SETTINGSTANDARD 
    SETTINGMEANING
    MB
     (Toggle Switch)
    UPCircuit card make-busy
    DOWN×Circuit card make-busy cancel
    MBR
     
    (Piano Switch)
    0ON Line 0 make-busy request
    OFF×Line 0 make-busy request cancel
    1ON Line 1 make-busy request
    OFF×Line 1 make-busy request cancel
    2ON Line 2 make-busy request
    OFF×Line 2 make-busy request cancel
    3ON Line 3 make-busy request
    OFF×Line 3 make-busy request cancel
    LPB
     (Piano Switch)
    0ON Loop back is set on NT1 for Line 0.
    OFF×Loop back is canceled on NT1 for Line 0.
    1ON Loop back is set on NT1 for Line 1.
    OFF×Loop back is canceled on NT1 for Line 1.
    2ON Loop back is set on NT1 for Line 2.
    OFF×Loop back is canceled on NT1 for Line 2.
    3ON Loop back is set on NT1 for Line 3.
    OFF×Loop back is canceled on NT1 for Line 3.
    MODE 
    (Rotary Switch)
    0×Fixed
    1~FNot used
    SW10 
    (DIP Switch)
    1ON Mounted in WCS
    OFF×Mounted in PCS
    2ON×Fixed
    3ON×µ-law
    OFF A-law
    4ON×Fixed
    ON (MB)
    OFF
    No. 3
    No. 2
    No. 1
    No. 0OFF
    ON
    No. 3
    No. 2
    No. 1
    No. 0OFF
    ON
    ON
    12
    34 
    						
    							CHAPTER 3 ND-70290 (E)
    Pag e 7 8
    Revision 3.0
    PA-4CSIF (CSINT)
    SWITCH NAMESWITCH 
    NUMBERSWITCH
    SETTINGSTANDARD 
    SETTINGMEANING
    SW11 1 ON×
    Fixed
    2ON×
    Fixed
    3ON×
    Fixed
    4ON×
    Fixed
    5ON×PB Sender Mode (Law/Level)
    Note:µ/A-law can be selected on the TSW side
    PA D .
    µ-law standard = High: –7.0 dBm
    Low: –9.0 dBm
    A-law standard = High: –8.0 dBm
    Low: –10.0 dBm OFF
    6ON×
    OFF
    7ON×
    Not used
    8ON Sealing Current is not supplied.
    OFF×
    Sealing Current is supplied.
    (DIP Switch)
    ON
    12
    3456
    78
    SW5 SW6 LAW/LEVEL
    OFF OFF Not used
    ON OFF
    OFF ON
    ON ONµ-law standard
    A-law standard 
    Note  
    						
    							ND-70290 (E) CHAPTER 3
    Page 79
    Revision 3.0
    PA-4CSIF (CSINT)
    [Firmware: SW-360]
    Note 1:
    PAD control is shown below.
    SWITCH NAMESWITCH 
    NUMBERSWITCH 
    SETTINGSTANDARD 
    SETTINGMEANING
    SW12
    (DIP Switch)
    1~8
    ON
    12
    3456 78
    Connection with C.O. Note
    Connection with a station  Note
    SWITCH 1 SWITCH 2 SWITCH 3 PAD VALUE
    OFF OFF OFF Not used
    ON OFF OFF Not used
    OFF ON OFF PAD 1=3 dB
    ON ON OFF PAD 1=0 dB
    OFF OFF ON PAD 1=–3 dB
    ON OFF ON PAD 1=–5 dB
    (Standard setting)
    OFF ON ON PAD 1=–7 dB
    ON ON ON PAD 1=–10 dB
    SWITCH 4 PAD VALUE
    ON PAD 2=3 dB (Standard setting)
    OFF PAD 2=0 dB
    SWITCH 5 SWITCH 6 SWITCH 7 PAD VALUE
    OFF OFF OFF Not used
    ON OFF OFF PAD 1=5 dB
    OFF ON OFF PAD 1=3 dB
    ON ON OFF PAD 1=0 dB
    (Standard setting)
    OFF OFF ON PAD 1=–3 dB
    ON OFF ON PAD 1=–5 dB
    OFF ON ON PAD 1=–7 dB
    ON ON ON PAD 1=–10 dB
    SWITCH 8 PAD VALUE
    ON PAD 2=3 dB
    OFF PAD 2=0 dB (Standard setting)
    PAD 1
    PAD 2 TSW Side
    Line Side 
    						
    							CHAPTER 3 ND-70290 (E)
    Pag e 8 0
    Revision 3.0
    PA-4CSIF (CSINT)
    SWITCH NAMESWITCH 
    NUMBERSWITCH
    SETTINGSTANDARD 
    SETTINGMEANING
    SW20 1 OFF×Fixed
    2OFF×Fixed
    3OFF×Fixed
    4OFF×Fixed
    SW21 1 ON×Not used
    2ON×Not used
    3ON×Not used
    4ON×Not used
    5ON×Not used
    6ON×Not used
    7ON×Not used
    8ON×Fixed
    (DIP Switch)
    ON
    12
    34
    (DIP Switch)
    ON
    12
    3456
    78 
    						
    							ND-70290 (E) CHAPTER 3
    Page 81
    Revision 3.0
    PA-4CSIF (CSINT)
    PA-4CSIF (CSINT) : ZT (Zone Transceiver) Interface
    Switch Setting Table
    MODULE
    NAMESLOTSWITCH 
    NAMESWITCH SHAPE REMARKS
    PIM MB ON : Make-busy set of circuit 
    card 
    OFF : Make-busy cancel of 
    circuit card
    MBR
    LPB
    MODE
    SW10
    SW11
    SW12
    SW20
    SW21
    ON
    No. 3
    No. 2
    No. 1
    No. 0OFF
    ON
    No. 3
    No. 2
    No. 1
    No. 0OFF
    ON
    0
    ON
    1234
    ON
    12
    3456 78
    ON
    12
    3
    456 78
    ON
    1234
    ON
    12
    3
    456 78 
    						
    							CHAPTER 3 ND-70290 (E)
    Pag e 8 2
    Revision 3.0
    PA-4CSIF (CSINT)
    6. External interface
    Shown in Figure 3-15 are accommodation of the LT connector leads of this circuit card and connecting route
    diagram.
    a. When this circuit card is mounted in PIM.
    Figure 3-15  LT Connector Leads Accommodation of PIM : PA-4CSIF
    26272829303132333435363738394041
    1234567891011121314151642434445464748
    1718192021222349502425
    Accommodated in *1
    LT0, 2, 4, 6, 8, 10 Connector
    LT Connector Accommodation
    26272829303132333435363738394041
    1234567891011121314151642434445464748
    1718192021222349502425
    Accommodated in *2
    LT1, 3, 5, 7, 9,11 Connector
    26272829303132333435363738394041
    1234567891011121314151642434445464748
    1718192021222349502425
    Accommodated in *3
    LT1, 3, 5, 7, 9, 11 Connector
    232221201918171615141312111009080706050403020100
    LT6 LT7 LT8 LT9 LT10 LT11LT0 LT1 LT2 LT3 LT4 LT5
    23 19 15
    22 18 14
    21 17 13
    20 16 1223 19 15
    22 18 14
    21 17 13
    20 16 12 11 09 07 05 03 01
    10 08 06 04 02 00 11 09 07 05 03 01
    10 08 06 04 02 00
    Group No.
    Slot No.
    LT Connector Name
    PIM
    32
    **
    Highway Block
    01324567981011 2*
    1*
    1*
    2*
    3*
    1*
    3*
    1*
    3*
    1*
    3*
    2*
    1*
    3*
    2* B0
    B1
    B2
    B3A0
    A1
    A2
    A3
    2* B0
    B1
    B2
    B3A0
    A1
    A2
    A3
    B0
    B1
    B2
    B3A0
    A1
    A2
    A3
    PWR PWR 
    						
    							ND-70290 (E) CHAPTER 3
    Page 83
    Revision 3.0
    PA-4CSIF (CSINT)
    Figure 3-16  Connecting Route Diagram
    MDF
    PIM
    NT1 A
    B
    CSINTA
    B 
    						
    All NEC manuals Comments (0)

    Related Manuals for NEC Neax 2400 Imx Wireless System Manual