Have a look at the manual Vodavi Infinite 4096 Key Telephone System Installation And Maintenance Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 60 Vodavi manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Infinite 4096 Hybrid Eey Telephone System INFATTE4096COMPONENT LIST / 1 1 I 1 1 L 1 APPENDIX B mllV=F’mTE 4096 COMPONENT LIST Appendix El &jMte 4096 Component List 4096 Basic Key Service Unit (KSUI 4096 Central Processor Board (CPB) DC/DC Converter (DCUj Key Station Interface Board (KIB) Central Office Interface Board (COB) Arnpmed Central Of&e Board (COA) Power Supply Unit (PS) External Power Supply Housing (EPS) Enhanced Key Telephone Executtve Key Telephone Expansion Key Service Unit (EKSU) Direct Station/Line Selector (DSS/DLS) Phone Box RS232C Module (RSM) Battery Charging Card (BC) Power Failure Transfer Unit (PFn Applications Board (APL) Off-Premise &tension Board (OPXI Single Line Telephone Interface Board (SIB) Key Station Interface Board w/OHVA (KSB/OHV) Single Line Ring Generator (RG) Single Line DTMFRS Unit (SLU’) 4096 Desc. Lnstall, and Oper Manual 4096 Station Users Guide 4096 Attendant Users Guide 4096 SLT Users Guide CT Ran Connector Cable 9EC Messenger 212 Plus Ran Device irfintte Wall Mount Kit Infinite Replacement Handset Cord Infinite Blank Designation Tabs $096 DSS/DLS Numbered Designation Tabs 2OVCSOO3 23vCsOo1 2 1vCsOo3 23vCSOo7 23vCsO10 23VCsOll 2 lVCSOO2 2 1vCs00 1 1 ovCS200 10vCs202 2OVCSOO4 17vCsoo 1 26VCsoo2 23vCSO14 22VCSOO4 23vcso 15 23vcso 12 2 lVCSOO4 23vcsoo9 23VCSOO8 ~21VCSOO5 23vcso 13 oovCs202 oovCS2 13 oovCS2 15 oovCS2 14 98ACT462 1 GVCSOO 1 18VCSOO 1 OOVCS205 00vcs209 Issue 1, January 1992 Appendix B-l
AECThe Description APPENDIX C Messengerm 212 Plus AEc’s ‘Ihe Messenger 212 Plus. Dual-Line Announcer can be used to provide the Re- corded Announcement feature of the Zr@i& 4096 Uniform Call Distribution feature (UCD) that provides unanswered incoming CO Calls or calls in queue with a recorded message while waiting for an available UCD station. The In$ni& 4096 systems provide a program- mable option that allows the use of unused CO line positions. SLT ports as the specified RAN output port(s) or the APL RAN port. Each UCD group may be programmed to connect a waiting caller to either the list or second RAN port for the initial message, then select the other RAN port, if connected, for the second and subsequent messages. Installation The Messenger 2 12 Plus can be connected to the I- 4096 in the following configura- tiOXL‘3. - One or Two SLT ports. - One or Two CO line ports. - The APL RAN port and if needed one CO line port. The connection of each type of port requires different installation practices and will be de- scribed separately. SLT Ports To install the 2 12 Plus using one or two SLT ports the following equipment is required and must be installed for proper operation. - An SLT board with available ports. (23vcsoo9) - One APL Board. (23VCSO 12) - One RG/MW power supply (2 lvCsoo5) - One or two modular jacks (4 or 6 pin). When connecting the Messenger 2 12 Plus using one or two SLT ports the following op- tions on the 212 Plus unit must be set: 1. Set the switches on the back of the unit as follows; Sl - off s2 - off s3 - off s4 - off 2. The internal jumper plug of the Messen- ger 212 Plus should be in its default line type setting of CO/PBX. This will match the SLT port(s) of the system and provide ring mp for the start of the message. NOTE: When the jumper plug of the Messenger 212 Plus is set to CO/PBX for the line type then both lines of the Messenger must be connected to SLT ports of the system. 3. Connect the Voice Tip and Voice Ring from the *J” connector of the SLT port being used to a modularjack. Using the line cords provided plug in to the modu- lar jack and one of the Line jacks in the back of the Messenger 2 12 Plus unit (See flgure 1) APL RAN and CO Line Ports For connection of the Messenger to either the APL RAN Port or to a CO line Port the Messen- ger 212 Plus must be configured as follows. 1. Set the switches on the back of the Messenger 212 Plus unit as follows; Sl - off s2 - off s3 - off s4 - on Issue 1. January 1992 Appendix C-l
AEC The Messenger= 2 12 Plus hfiite 4096 Hybrid Eey Telephone System F’i@m Cl SLT to AEC Connectiona 2. The internal jumper plug of the Messen- ger 212 Plus unit should be set to the first altematlve setting for a 600 ohm transformer coupled audio output. Check the Messenger 2 12 Plus Owners Manual for procedures on changing the internal jumper plug. NOTE: Using the 600 ohm setting of the Messenger 2 12 Plus both lines of the Messenger must be connected to any combination of the APL RAN out- put port or one or two CO line port(s). When installfng the Messenger 212 Plus unit onto the 4096 System, both the APL RAN output port and a CO Line port can be used simultaneously. However connection of the Messenger to these ports is different For this reason each type. of installation will be de- scribed separately. APL RAN Port When the Messenger 2 12 Plus unit is installed using the APL RAN port the following equip- ment will be required. - An AF’L Board (23VCSO12) - An Am 8 position to 6 position modular line cord. (98ACT462) 1. To connect the Messenger 2 12 Plus to the APL RAN jack plug the 6 position end of the ACT modular line cord into the APL RAN Port (APL MOD 3 jackl then plug the 8 position end of the line cord into the line 1 or line 2 position on the back of the Messenger 2 12 Plus unit. If an ACT 8 position to 6 position cord is not available use the wiring diagram in f3gure 2 as a guide to connect the Messenger 2 12 Plus unit to the APL RAN port, CO Line as a RAN Port To Install the Messenger 2 12 Plus using a CO Line port as the R4N output port the following equipment is necessary for a proper installa- tion. - Unused CO line ports on a, COB or COA Board. (23VCSO 10 or 23VCSO 11) - Power Fail Transfer unit (23VCSOlS) with Loud Bell Control for each CO port to be used. - 24 volt DC power supply to provide a fflteredtalkpa,thIlessthan 1 ampis required). - Two (2) 300 ohm l/4 watt resistors for each circuit. - One or two 8 conductor modular jacks and 8 conductor line cords. Appendix C2 Issue 1, January 1992
Injinite 4096 Hybrid Key Telephone System AEC The Messengerm 212 Plus APL RAN Jade PklX STOP 1 START 2 VOICE 3 VOICE 4 START 5 212 Plus Line Jack PinX 1 STOP 2 STOP D 3 4 VOICE 5 VOICE b 6 STOP 6 7 GROUND 8 START Fi@1reG2 ACTSCond.to6Cond.RANLheCord To install the Messenger 2 12 Plus using a CO circuit as the interface connect as described below. (see figure 3) 1. Connect the 300 ohm resistor ln series with the - (negattve) lead of the 24 volt DC power supply and the CO tip on the ‘P” connector. Depending on the application the following program codes will need to be updated. a Universal Call Distribution (FLASH 19) It is necessary to specify which RAN table(s) will be used for each UCD group assigned. This is done by pressing button 12 while in UCD programming. 2. Next connect the second 300 ohm resfs- tor in series to the + (positive) lead of the power supply and the 8 position modular connector pin 5 mp / green). 3. Then wire the ring lead from the ‘Y connector of the CO port being used to pin 4 of the 8 pin modular jack (Ring / red). 4. Connect both of the LBC contact leads of the Power Fail Transfer unit to the START and GROUND leads of the 8 pin modular jack (pins 7 and 8). Connection of the Messenger 212 Plus to the system Ls now complete. Proceed wltb apply- ing power and recording your message(s) as described in the Messenger 2 12 Plus Owners manual. Programming It will be necessary to update the data base of the 4096 system to include the RAN opuons. b UCD Timers 0?LASH 33) The Ring timer (button 1) determines how long an Incom- ing CO call will ring into the UCD group before being answered and presented to the first message. The Message Interval Timer (Mll’J(button 2) determines the duration of time the caller will be in queue and on hold be- tween messages The OVeRflow timer lbution 3) determines the total time, starting from when the call was answered, a caller will be kept in queue before being routed to the overflow station. c Announcement Tables (FLASH 34) This determines the type. index (port) number and length for the two available Recorded announcements (RAN). When defining SLT port(s) or CO Line port(s) as the RAN output port it is most important to set the TIME parameter (length of the message) in the An- Issue 1. January 1992 Appendix C-3
AEC The Messengean 212 Plus Finite 4096 Hybrid Key Telephone System nouncement Table so that it ls approxi- mately one second longer than the actual message. d WhenaCOlfnehastxenuseditwillbe necessaq to program an LBC contact to that particular line. This is accompkhed in Loud Bell Control assignments @WISH 16). AssigntheCOporttobeusedforthe RAN operation to one of the LBC contacts. Refer to the Iry%ti& 4096 Description. Instal- lation and Operation manual for further in- structfons on how to enter the program mode and additional information on the above listed program options. Also reference The Messen- ger Owner’s Manual for recording, battery operation and troubleshooting information. ‘p’ Bkck (66 Type) I AEC The Messenger 212 Plus I _----- I Tmetds GROW0 p---J LBC STAAT Appe*c- G-4 Issue 1, January 1992